959 resultados para Simulated performance
Resumo:
We introduce a new hybrid approach to determine the ground state geometry of molecular systems. Firstly, we compared the ability of genetic algorithm (GA) and simulated annealing (SA) to find the lowest energy geometry of silicon clusters with six and 10 atoms. This comparison showed that GA exhibits fast initial convergence, but its performance deteriorates as it approaches the desired global extreme. Interestingly, SA showed a complementary convergence pattern, in addition to high accuracy. Our new procedure combines selected features from GA and SA to achieve weak dependence on initial parameters, parallel search strategy, fast convergence and high accuracy. This hybrid algorithm outperforms GA and SA by one order of magnitude for small silicon clusters (Si6 and Si10). Next, we applied the hybrid method to study the geometry of a 20-atom silicon cluster. It was able to find an original geometry, apparently lower in energy than those previously described in literature. In principle, our procedure can be applied successfully to any molecular system. © 1998 Elsevier Science B.V.
Resumo:
'Profusion Cherry' is a dwarf zinnia with prospect for pot use in Brazil. The success of flowering potted plants depends on its performance during transport and on the period of time that it performs well indoors. Benzyladenine application may retard leaf and flower senescence, increasing postproduction longevity and quality. Senescent flowers removal by consumers, to give a fresh appearance to home flowering potted plant, could influence source-sink relationship and postproduction. This study evaluated the effect of benzyladenine and senescent flowers removal on postproduction performance of 'Profusion Cherry', and observed the senescence symptoms. When plants, produced in greenhouse at São Paulo State, Brazil, had 4 to 5 open flowers, they were sprayed to runoff a single time (20ml/pot) with benzyladenine (0.4, 0.6, 0.8 or 1.0 mmol) and placed into plastic trays, without sleeve. The experimental design was a randomized blocks with 6 treatments (control, four benzyladenine concentrations and senescent flowers removal), 4 replications (2 pots per experimental unit), totalising 12 potted plants in each plastic tray (block). To simulate highway transport, plants remained for 4 days in a dark chamber, at 20.0 °C without irrigation. To include vibration, each plastic tray, was placed in an incubator shaker for 3hr a day, at 60 rpm, 25°C and darkness. After simulated transport, plants remained indoors (10h.day-1 with 18 μmol.m-2.s-1 PPF, 21.5 to 27.0°C and, 14 h.day-1 at darkness, 18.5 to 24.0°C) during 21 days. Plants performed well during simulated transport, and also indoors for two weeks. For most of evaluated parameters there was not significant effect of benzyladenine concentrations by Tukey's test. Senescent flowers removal did not delayed senescence or improved plants quality. The symptoms associated with the loss of decorative life were ray florets color fading and wilting, without abscission of flowers or petals.
Resumo:
One of the most important characteristics of intelligent activity is the ability to change behaviour according to many forms of feedback. Through learning an agent can interact with its environment to improve its performance over time. However, most of the techniques known that involves learning are time expensive, i.e., once the agent is supposed to learn over time by experimentation, the task has to be executed many times. Hence, high fidelity simulators can save a lot of time. In this context, this paper describes the framework designed to allow a team of real RoboNova-I humanoids robots to be simulated under USARSim environment. Details about the complete process of modeling and programming the robot are given, as well as the learning methodology proposed to improve robot's performance. Due to the use of a high fidelity model, the learning algorithms can be widely explored in simulation before adapted to real robots. © 2008 Springer-Verlag Berlin Heidelberg.
Resumo:
Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.
Resumo:
To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. Results: For permanent teeth, the LFpen cut‑off were 0– 27 (sound), 28– 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0– 7 (sound), 8– 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. Conclusion: LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.
Resumo:
Moreira, A, McGuigan, MR, Arruda, AFS, Freitas, CG, and Aoki, MS. Monitoring internal load parameters during simulated and official basketball matches. J Strength Cond Res 26(3): 861-866, 2012-The purpose of this study was to compare the internal load responses (session rating of perceived exertion [RPE] and salivary cortisol) between simulated and official matches (SM and OM). Ten professional basketball players participated in 2 OMs and 2 SMs during the competition season. Subjects provided saliva samples 30 minutes before the prematch warm-up (PRE) and 10 minutes after the end of the match. Session RPE (CR-10 scale) was assessed 30 minutes after each match. The results from the 2-way analysis of variance showed significant differences for post-OM salivary cortisol as compared with pre-OM values (p < 0.05). No changes were observed for cortisol during the SM. Before the OM, a significant difference in salivary cortisol was observed as compared with pre-SM values (p < 0.05). Moreover, the OM session RPE was significantly greater than that of SM. There was a significant correlation between session RPE and cortisol changes (r = 0.75). In summary, the results of this study showed a greater magnitude of cortisol and session RPE responses after OM as compared with that after SM confirming the hypothesis that a real competition generates a greater stress response than a simulated condition does. The anticipatory effect was also observed in the OM. In addition, the results indicate that session RPE seems to be a viable tool in monitoring internal loads, and the results are useful in providing a better understanding of internal loads imposed by basketball training and competitions. The precise monitoring of these responses might help the coaches to plan appropriate loads maximizing recovery and performance.
Resumo:
We investigated the effects of high pressure on the point of no return or the minimum time required for a kicker to respond to the goalkeeper's dive in a simulated penalty kick task. The goalkeeper moved to one side with different times available for the participants to direct the ball to the opposite side in low-pressure (acoustically isolated laboratory) and high-pressure situations (with a participative audience). One group of participants showed a significant lengthening of the point of no return under high pressure. With less time available, performance was at chance level. Unexpectedly, in a second group of participants, high pressure caused a qualitative change in which for short times available participants were inclined to aim in the direction of the goalkeeper's move. The distinct effects of high pressure are discussed within attentional control theory to reflect a decreasing efficiency of the goal-driven attentional system, slowing down performance, and a decreasing effectiveness in inhibiting stimulus-driven behavior.
Resumo:
The purpose of this study was to determine the physiological, anthropometric, performance, and nutritional characteristics of the Brazil Canoe Polo National Team. Ten male canoe polo athletes (age 26.7 +/- 4.1 years) performed a battery of tests including assessments of anthropometric parameters, upper-body anaerobic power (Wingate), muscular strength, aerobic power, and nutritional profile. In addition, we characterized heart rate and plasma lactate responses and the temporal pattern of the effort/recovery during a simulated canoe polo match. The main results are as follows: body fat, 12.3 +/- 4.0%; upper-body peak and mean power, 6.8 +/- 0.5 and 4.7 +/- 0.4 W . kg(-1), respectively; 1-RM bench press, 99.1 +/- 11.7 kg; peak oxygen uptake, 44.3 +/- 5.8 mL . kg(-1) . min(-1); total energy intake, 42.8 +/- 8.6 kcal . kg(-1); protein, carbohydrate, and fat intakes, 1.9 +/- 0.1, 5.0 +/- 1.5, and 1.7 +/- 0.4 g . kg(-1), respectively; mean heart rate, 146 +/- 11 beats . min(-1); plasma lactate, 5.7 +/- 3.8 mmol . L-1 at half-time and 4.6 +/- 2.2 mmol . L-1 at the end of the match; effort time (relative to total match time), 93.1 +/- 3.0%; number of sprints, 9.6 +/- 4.4. The results of this study will assist coaches, trainers, and nutritionists in developing more adequate training programmes and dietary interventions for canoe polo athletes.
Resumo:
We examined the effects of listening to music on attentional focus, rating of perceived exertion (RPE), pacing strategy and performance during a simulated 5-km running race. 15 participants performed 2 controlled trials to establish their best baseline time, followed by 2 counterbalanced experimental trials during which they listened to music during the first (M-start) or the last (M-finish) 1.5 km. The mean running velocity during the first 1.5 km was significantly higher in M-start than in the fastest control condition (p < 0.05), but there was no difference in velocity between conditions during the last 1.5 km (p > 0.05). The faster first 1.5 m in M-start was accompanied by a reduction in associative thoughts compared with the fastest control condition. There were no significant differences in RPE between conditions (p > 0.05). These results suggest that listening to music at the beginning of a trial may draw the attentional focus away from internal sensations of fatigue to thoughts about the external environment. However, along with the reduction in associative thoughts and the increase in running velocity while listening to music, the RPE increased linearly and similarly under all conditions, suggesting that the change in velocity throughout the race may be to maintain the same rate of RPE increase.
Resumo:
Abstract Background Carbohydrate (CHO) ingestion may be an interesting approach to avoid significant decrement to the tennis match performance. The aim of the present investigation was to assess the effects of CHO supplementation on tennis match play performance. Methods Twelve young tennis players (18.0 ± 1.0 years; 176 ± 3.4 cm; 68.0 ± 2.3 kg; body fat: 13.7 ± 2.4%) with national rankings among the top 50 in Brazil agreed to participate in this study, which utilized a randomized, crossover, double blind research design. The experiment was conducted over a 5-day period in which each player completed two simulated tennis matches of a 3-hour duration. The players received either a CHO or a placebo (PLA) drinking solution during simulated tennis matches. Athlete’s performance parameters were determined by filming each match with two video cameras. Each player was individually tracked for the entire duration of the match to measure the following variables: (1) games won; (2) rally duration; (3) strokes per rally; (4) effective playing time (%); (5) aces; (6) double faults; (7) first service in; (8) second service in; (9) first return in and (10) second return in. Results There were no differences between trials in any of the variables analyzed. Conclusions CHO supplementation did not improve tennis match play performance under the present experimental conditions.
Resumo:
Patients with homonymous hemianopia have altered visual search patterns, but it is unclear how rapidly this develops and whether it reflects a strategic adaptation to altered perception or plastic changes to tissue damage. To study the temporal dynamics of adaptation alone, we used a gaze-contingent display to simulate left or right hemianopia in 10 healthy individuals as they performed 25 visual search trials. Visual search was slower and less accurate in hemianopic than in full-field viewing. With full-field viewing, there were improvements in search speed, fixation density, and number of fixations over the first 9 trials, then stable performance. With hemianopic viewing, there was a rapid shift of fixation into the blind field over the first 5-7 trials, followed by continuing gradual improvements in completion time, number of fixations, and fixation density over all 25 trials. We conclude that in the first minutes after onset of hemianopia, there is a biphasic pattern of adaptation to altered perception: an early rapid qualitative change that shifts visual search into the blind side, followed by more gradual gains in the efficiency of using this new strategy, a pattern that has parallels in other studies of motor learning.
Resumo:
In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Methods Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. Results All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. Conclusions The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.
Resumo:
To assess the effect of tumor size and tumor-to-liver contrast of simulated hypovascular liver tumors on the diagnostic accuracy of hepatic computed tomography (CT).
Resumo:
Transformers are very important elements of any power system. Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient protection for transformers as well as the best possible selectivity and sensitivity of the protection. Nowadays microprocessor-based relays are widely used to protect power equipment. Current differential and voltage protection strategies are used in transformer protection applications and provide fast and sensitive multi-level protection and monitoring. The elements responsible for detecting turn-to-turn and turn-to-ground faults are the negative-sequence percentage differential element and restricted earth-fault (REF) element, respectively. During severe internal faults current transformers can saturate and slow down the speed of relay operation which affects the degree of equipment damage. The scope of this work is to develop a modeling methodology to perform simulations and laboratory tests for internal faults such as turn-to-turn and turn-to-ground for two step-down power transformers with capacity ratings of 11.2 MVA and 290 MVA. The simulated current waveforms are injected to a microprocessor relay to check its sensitivity for these internal faults. Saturation of current transformers is also studied in this work. All simulations are performed with the Alternative Transients Program (ATP) utilizing the internal fault model for three-phase two-winding transformers. The tested microprocessor relay is the SEL-487E current differential and voltage protection relay. The results showed that the ATP internal fault model can be used for testing microprocessor relays for any percentage of turns involved in an internal fault. An interesting observation from the experiments was that the SEL-487E relay is more sensitive to turn-to-turn faults than advertized for the transformers studied. The sensitivity of the restricted earth-fault element was confirmed. CT saturation cases showed that low accuracy CTs can be saturated with a high percentage of turn-to-turn faults, where the CT burden will affect the extent of saturation. Recommendations for future work include more accurate simulation of internal faults, transformer energization inrush, and other scenarios involving core saturation, using the newest version of the internal fault model. The SEL-487E relay or other microprocessor relays should again be tested for performance. Also, application of a grounding bank to the delta-connected side of a transformer will increase the zone of protection and relay performance can be tested for internal ground faults on both sides of a transformer.
Resumo:
Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signal to noise ratio for rooms with realistic reverberation and more than 18 dB under anechoic conditions. Speech understanding in noise is measured in 6 adult cochlear implant users in a reverberant room, showing average improvements of 7.9–9.6 dB, when compared to a single omnidirectional microphone or 1.3–5.6 dB, when compared to a simple directional two-microphone device. Subjective evaluation in a cafeteria at lunchtime shows a preference of the cochlear implant users for the evaluated device in terms of speech understanding and sound quality.