920 resultados para Set-up errors
Resumo:
The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^
Resumo:
To obtain a state-of-the-art benchmark potential energy surface (PES) for the archetypal oxidative addition of the methane C-H bond to the palladium atom, we have explored this PES using a hierarchical series of ab initio methods (Hartree-Fock, second-order Møller-Plesset perturbation theory, fourth-order Møller-Plesset perturbation theory with single, double and quadruple excitations, coupled cluster theory with single and double excitations (CCSD), and with triple excitations treated perturbatively [CCSD(T)]) and hybrid density functional theory using the B3LYP functional, in combination with a hierarchical series of ten Gaussian-type basis sets, up to g polarization. Relativistic effects are taken into account either through a relativistic effective core potential for palladium or through a full four-component all-electron approach. Counterpoise corrected relative energies of stationary points are converged to within 0.1-0.2 kcal/mol as a function of the basis-set size. Our best estimate of kinetic and thermodynamic parameters is -8.1 (-8.3) kcal/mol for the formation of the reactant complex, 5.8 (3.1) kcal/mol for the activation energy relative to the separate reactants, and 0.8 (-1.2) kcal/mol for the reaction energy (zero-point vibrational energy-corrected values in parentheses). This agrees well with available experimental data. Our work highlights the importance of sufficient higher angular momentum polarization functions, f and g, for correctly describing metal-d-electron correlation and, thus, for obtaining reliable relative energies. We show that standard basis sets, such as LANL2DZ+ 1f for palladium, are not sufficiently polarized for this purpose and lead to erroneous CCSD(T) results. B3LYP is associated with smaller basis set superposition errors and shows faster convergence with basis-set size but yields relative energies (in particular, a reaction barrier) that are ca. 3.5 kcal/mol higher than the corresponding CCSD(T) values
Resumo:
To obtain a state-of-the-art benchmark potential energy surface (PES) for the archetypal oxidative addition of the methane C-H bond to the palladium atom, we have explored this PES using a hierarchical series of ab initio methods (Hartree-Fock, second-order Møller-Plesset perturbation theory, fourth-order Møller-Plesset perturbation theory with single, double and quadruple excitations, coupled cluster theory with single and double excitations (CCSD), and with triple excitations treated perturbatively [CCSD(T)]) and hybrid density functional theory using the B3LYP functional, in combination with a hierarchical series of ten Gaussian-type basis sets, up to g polarization. Relativistic effects are taken into account either through a relativistic effective core potential for palladium or through a full four-component all-electron approach. Counterpoise corrected relative energies of stationary points are converged to within 0.1-0.2 kcal/mol as a function of the basis-set size. Our best estimate of kinetic and thermodynamic parameters is -8.1 (-8.3) kcal/mol for the formation of the reactant complex, 5.8 (3.1) kcal/mol for the activation energy relative to the separate reactants, and 0.8 (-1.2) kcal/mol for the reaction energy (zero-point vibrational energy-corrected values in parentheses). This agrees well with available experimental data. Our work highlights the importance of sufficient higher angular momentum polarization functions, f and g, for correctly describing metal-d-electron correlation and, thus, for obtaining reliable relative energies. We show that standard basis sets, such as LANL2DZ+ 1f for palladium, are not sufficiently polarized for this purpose and lead to erroneous CCSD(T) results. B3LYP is associated with smaller basis set superposition errors and shows faster convergence with basis-set size but yields relative energies (in particular, a reaction barrier) that are ca. 3.5 kcal/mol higher than the corresponding CCSD(T) values
Resumo:
Este trabalho investiga, no mercado acionário brasileiro, o efeito da contabilidade de hedge na qualidade das informações contábeis divulgadas, no disclosure dos instrumentos financeiros derivativos e na assimetria de informação. Para medir a qualidade da informação contábil, foram utilizadas as métricas de relevância da informação contábil e informatividade dos lucros contábeis. Para a execução deste trabalho, foi constituída uma amostra geral com empresas brasileiras, não financeiras, listadas na Bolsa de Valores de São Paulo, compreendendo as 150 empresas com maior valor de mercado em 01/01/2014. A partir da amostra geral, foram constituídas amostras para a aplicação dos modelos de value relevance, informativeness, disclosure e assimetria de informação. A amostra para relevância contou com 758 observações firmas-anos, para o período de 2008 a 2013. A amostra para informatividade contou com 701 observações firmas-anos, para o período de 2008 a 2013. A amostra para disclosure contou com 100 observações firmas-anos, para o período de 2011 a 2012. A amostra para assimetria de informação contou com 100 observações firmas-anos, para o período de 2011 a 2012. Para as análises dos dados, utilizou-se regressões com errospadrão robustos com abordagem POLS e Efeitos Fixos, aplicadas sobre dados em painel. Complementarmente, para as análises do efeito do hedge accounting sobre o disclosure e assimetria de informação, foi aplicado o método de Propensity Score Matching. As evidências encontradas para a influência da contabilidade de hedge na relevância da informação contábil apontaram uma relação positiva e significante na interação com o LL. Na análise da informatividade dos lucros contábeis, a pesquisa evidenciou uma relação negativa e estatisticamente significante do lucro quando interagido com a variável dummy de hedge accounting. Quanto às evidências encontradas para a influência do hedge accounting sobre o disclosure dos derivativos, verificou-se uma relação positiva e estatisticamente significante da dummy de hedge accounting com o indicador de evidenciação dos derivativos. Em relação às evidências para a assimetria de informação, embora os coeficientes se mostrassem no sentido esperado, os mesmos não foram estatisticamente significativos. Adicionalmente, incorporamse às análises econométricas uma análise descritiva, na amostra geral, da utilização do hedge accounting no Brasil, para o ano de 2013. Dentre as 150 empresas da amostra, 49 empresas utilizaram hedge accounting, onde 41 empresas adotam apenas 1 tipo de hedge. O hedge de fluxo de caixa é o tipo de hedge mais adotado pelas empresas, sendo utilizado por 42 companhias.
Resumo:
Introdução – Numa era em que os tratamentos de Radioterapia Externa (RTE) exigem cada vez mais precisão, a utilização de imagem médica permitirá medir, quantificar e avaliar o impacto do erro provocado pela execução do tratamento ou pelos movimentos dos órgãos. Objetivo – Analisar os dados existentes na literatura acerca de desvios de posicionamento (DP) em patologias de cabeça e pescoço (CP) e próstata, medidos com Cone Beam Computed Tomography (CBCT) ou Electronic Portal Image Device (EPID). Metodologia – Para esta revisão da literatura foram pesquisados artigos recorrendo às bases de dados MEDLINE/PubMed e b-on. Foram incluídos artigos que reportassem DP em patologias CP e próstata medidos através de CBCT e EPID. Seguidamente foram aplicados critérios de validação, que permitiram a seleção dos estudos. Resultados – Após a análise de 35 artigos foram incluídos 13 estudos e validados 9 estudos. Para tumores CP, a média (μ) dos DP encontra-se entre 0,0 e 1,2mm, com um desvio padrão (σ) máximo de 1,3mm. Para patologias de próstata observa-se μDP compreendido entre 0,0 e 7,1mm, com σ máximo de 7,5mm. Discussão/Conclusão – Os DP em patologias CP são atribuídos, maioritariamente, aos efeitos secundários da RTE, como mucosite e dor, que afetam a deglutição e conduzem ao emagrecimento, contribuindo para a instabilidade da posição do doente durante o tratamento, aumentando as incertezas de posicionamento. Os movimentos da próstata devem-se principalmente às variações de preenchimento vesical, retal e gás intestinal. O desconhecimento dos DP afeta negativamente a precisão da RTE. É importante detetá-los e quantificá-los para calcular margens adequadas e a magnitude dos erros, aumentando a precisão da administração de RTE, incluindo o aumento da segurança do doente. - ABSTRACT - Background and Purpose – In an era where precision is an increasing necessity in external radiotherapy (RT), modern medical imaging techniques provide means for measuring, quantifying and evaluating the impact of treatment execution and movement error. The aim of this paper is to review the current literature on the quantification of setup deviations (SD) in patients with head and neck (H&N) or prostate tumors, using Cone Beam Computed Tomography (CBCT) or Electronic Portal Image Device (EPID). Methods – According to the study protocol, MEDLINE/PubMed and b-on databases were searched for trials, which were analyzed using selection criteria based on the quality of the articles. Results – After assessment of 35 papers, 13 studies were included in this analysis and nine were authenticated (6 for prostate and 3 for H&N tumors). The SD in the treatment of H&N cancer patients is in the interval of 0.1 to 1.2mm, whereas in prostate cancer this interval is 0.0 to 7.1mm. Discussion – The reproducibility of patient positioning is the biggest barrier for higher precision in RT, which is affected by geometrical uncertainty, positioning errors and inter or intra-fraction organ movement. There are random and systematic errors associated to patient positioning, introduced since the treatment planning phase or through physiological organ movement. Conclusion – The H&N SD are mostly assigned to the Radiotherapy adverse effects, like mucositis and pain, which affect swallowing and decrease secretions, contributing for the instability of patient positioning during RT treatment and increasing positioning uncertainties. Prostate motion is mainly related to the variation in bladder and rectal filling. Ignoring SD affects negatively the accuracy of RT. Therefore, detection and quantification of SD is crucial in order to calculate appropriate margins, the magnitude of error and to improve accuracy in RTE and patient safety.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde.
Resumo:
O óxido de polifenileno com a marca comercial PPO® é uma das resinas principais produzidas na SABIC IP e o ingrediente principal do plástico de engenharia com a marca registada, Noryl®. A equipa de tecnologia de processo de PPO® desenvolve uma série de novos produtos em reactores de pequena escala, tanto em Selkirk como em Bergen op Zoom. Para se efectuar uma transição rápida da escala laboratorial para a fábrica, é necessário um conhecimento completo do reactor. O objectivo deste projecto consiste em esboçar linhas gerais para o scale-up de novos produtos de PPO1, do laboratório para a escala industrial, baseado no estudo de um tipo de PPO, PPO 803. Este estudo pode ser dividido em duas fases. Numa primeira fase, as receitas e os perfis da reacção são comparados, de onde se retiram as primeiras conclusões. Posteriormente, com base nestas conclusões, é realizado um planeamento experimental. O estudo inicial sugeriu que a receita, a temperatura inicial do reactor e a velocidade do agitador poderiam influenciar o tempo da reacção bem como a queda da velocidade intrínseca do polímero (IV drop). As reacções experimentais mostraram que a receita é o principal factor que influencia, tanto o tempo de reacção, como a queda de viscosidade intrínseca. O tempo de reacção será tanto maior quanto menor a agitação devido à má dispersão do oxigénio na mistura. O uso de temperaturas iniciais elevadas conduz a uma queda maior da viscosidade intrínseca devido à desactivação do catalisador. O método experimental utilizado no laboratório de Bergen op Zoom é um bom exemplo, simulador, do procedimento utilizado na fábrica.
Resumo:
Trabalho de Projecto apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ensino do Inglês
Resumo:
Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of μW, from an external AC field.
Resumo:
Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.
Segimon Comas : importància i contextualització històrica d'un universitari i acadèmic del set-cents
Resumo:
Contextualització històrica dels inicis de l'Acadèmia de Bones Lletres al segle XVIII, i un dels seus artífexs, Segimon Comas.
Resumo:
The Wake Up, Shake Up club was first set up in February 2013. The aim of the club is to support working parents and offer an affordable alternative to local childcare options. It is also an opportunity to re-enforce school healthy eating guidelines and explore different food options with children.The club is run by staff members of Holywell Childcare. 33 children attend each morning. There is a charge of €1 per child per day to cover staff costs. A selection of cereals is served each morning along with toast, fruit and fruit juice. Children can take part in different activities after breakfast, such as crafts, games, and even yoga ! Part of theBreakfast Clubs Pilot Programme Initiative Type Breakfast Clubs Location Dublin Target Groups Children ( 4-12 years) Start 18th Feb 2013
Resumo:
OBJECTIVE: To set-up an international cohort of patients suspected with Behçet's disease (BD). The cohort is aimed at defining an algorithm for definition of the disease in children. METHODS: International experts have defined the inclusion criteria as follows: recurrent oral aphthosis (ROA) plus one of following-genital ulceration, erythema nodosum, folliculitis, pustulous/acneiform lesions, positive pathergy test, uveitis, venous/arterial thrombosis and family history of BD. Onset of disease is <16 years, disease duration is ≤3 years, future follow-up duration is ≥4 years and informed consent is obtained. The expert committee has classified the included patients into: definite paediatric BD (PED-BD), probable PED-BD and no PED-BD. Statistical analysis is performed to compare the three groups of patients. Centres document their patients into a single database. RESULTS: At January 2010, 110 patients (56 males/54 females) have been included. Mean age at first symptom: 8.1 years (median 8.2 years). At inclusion, 38% had only one symptom associated with ROA, 31% had two and 31% had three or more symptoms. A total of 106 first evaluations have been done. Seventeen patients underwent the first-year evaluation, and 36 had no new symptoms, 12 had one and 9 had two. Experts have examined 48 files and classified 30 as definite and 18 as probable. Twenty-six patients classified as definite fulfilled the International Study Group criteria. Seventeen patients classified as probable did not meet the international criteria. CONCLUSION: The expert committee has classified the majority of patients in the BD group although they presented with few symptoms independently of BD classification criteria.
Resumo:
OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.
Resumo:
A didactic experiment is proposed aimed to extend the Flow Injection Analysis (FIA) based methodology to the area of physical chemistry/chemical reactors for undergraduate labs. Our prime objective was to describe the use of a gradient chamber for determination of the rate constant for the reaction between crystal violet and the hydroxide ion. The study was complemented by determining the effect of temperature on the rate constant. The kinetic parameters, activation energy and reaction rate constant are determined based on an assumption of rate orders. The main didactic advantages of the proposed experimental set-up are the use of less reagents, contributing to a more environmental friendly experiment. The experiment illustrates also the reduction of associated errors and time by using automated analysis owing to decreased operator manipulation.