984 resultados para Safety testing
Resumo:
OBJECTIVES: To determine if cognitive reflection has a positive influence on clinical decision making in undergraduate medical students. METHODS: 153 final year undergraduate medical students completed a 3 hour interactive Safe Thinking Workshop on nontechnical skills and patient safety, incorporating an introduction to metacognitive concepts. All students underwent augmented Cognitive Reflective Testing during the workshop. Students then inspected and interpreted a set of arterial blood gas results relating to a patient with acute respiratory distress, then answered a short questionnaire addressing biochemical diagnosis, clinical diagnosis and effective management. A separate question was embedded in the questionnaire to determine if astute students could determine the severity of the illness. The study group (n = 78) completed the questionnaire immediately after the Safe Thinking Workshop, whilst the control group (n = 75) completed the questionnaire prior to the Workshop.RESULTS: The mean total score for study students was 80.51%, with a mean total score of 57.9% for the control group (t-test; p<0.05). Correct classification of illness severity was observed in 13.2% of study students, compared with 4.1% of control students (p<0.05). CONCLUSION: These results suggest that clinical decision making and recognition of illness severity can be enhanced by specific teaching in nontechnical skills, metacognitiion and cognitive reflection.
Resumo:
Background: Tiotropium is a once-daily, long-acting anticholinergic bronchodilator with the potential to alleviate airway obstruction in cystic fibrosis. Our objective was to evaluate the efficacy and safety of 2.5 and 5 μg once-daily tiotropium delivered via the Respimat Soft Mist Inhaler vs. placebo in people with cystic fibrosis. Methods: This phase 2, 12-week, randomized, double-blind, placebo-controlled parallel-group study of tiotropium Respimat as add-on to usual cystic fibrosis maintenance therapy included people with cystic fibrosis with pre-bronchodilator forced expiratory volume in 1 second (FEV1) ≥25% predicted. Co-primary efficacy end points were change from baseline in percent-predicted FEV1area under the curve from 0 to 4 hours (FEV1AUC0-4h), and trough FEV1at the end of week 12. Findings: A total of 510 subjects with cystic fibrosis aged 5-69 years were randomized. Both doses of tiotropium resulted in significant improvement compared with placebo in the co-primary efficacy end points at the end of week 12 (change from baseline in percent-predicted FEV1AUC0-4h: 2.5 μg: 2.94%, 95% confidence interval 1.19-4.70, p = 0.001; 5 μg: 3.39%, 95% confidence interval 1.67-5.12, p = 0.0001; in percent-predicted trough FEV1:2.5 μg: 2.24%, p = 0.2; 5 μg: 2.22%, p = 0.02). There was a greater benefit with tiotropium 5 vs. 2.5 μg. No treatment-related adverse events or unexpected safety findings were observed in patients taking tiotropium. Conclusions: Tiotropium significantly improved lung function in people with cystic fibrosis. The improvement was greater with the higher dose than the lower dose, with no difference in adverse events.
Resumo:
O objeto principal desta tese é o estudo de algoritmos de processamento e representação automáticos de dados, em particular de informação obtida por sensores montados a bordo de veículos (2D e 3D), com aplicação em contexto de sistemas de apoio à condução. O trabalho foca alguns dos problemas que, quer os sistemas de condução automática (AD), quer os sistemas avançados de apoio à condução (ADAS), enfrentam hoje em dia. O documento é composto por duas partes. A primeira descreve o projeto, construção e desenvolvimento de três protótipos robóticos, incluindo pormenores associados aos sensores montados a bordo dos robôs, algoritmos e arquitecturas de software. Estes robôs foram utilizados como plataformas de ensaios para testar e validar as técnicas propostas. Para além disso, participaram em várias competições de condução autónoma tendo obtido muito bons resultados. A segunda parte deste documento apresenta vários algoritmos empregues na geração de representações intermédias de dados sensoriais. Estes podem ser utilizados para melhorar técnicas já existentes de reconhecimento de padrões, deteção ou navegação, e por este meio contribuir para futuras aplicações no âmbito dos AD ou ADAS. Dado que os veículos autónomos contêm uma grande quantidade de sensores de diferentes naturezas, representações intermédias são particularmente adequadas, pois podem lidar com problemas relacionados com as diversas naturezas dos dados (2D, 3D, fotométrica, etc.), com o carácter assíncrono dos dados (multiplos sensores a enviar dados a diferentes frequências), ou com o alinhamento dos dados (problemas de calibração, diferentes sensores a disponibilizar diferentes medições para um mesmo objeto). Neste âmbito, são propostas novas técnicas para a computação de uma representação multi-câmara multi-modal de transformação de perspectiva inversa, para a execução de correcção de côr entre imagens de forma a obter mosaicos de qualidade, ou para a geração de uma representação de cena baseada em primitivas poligonais, capaz de lidar com grandes quantidades de dados 3D e 2D, tendo inclusivamente a capacidade de refinar a representação à medida que novos dados sensoriais são recebidos.
Resumo:
BACKGROUND: Cilengitide is a selective integrin inhibitor that is well tolerated and has demonstrated biologic activity in patients with recurrent malignant glioma. The primary objectives of this randomized phase 2 trial were to determine the safety and efficacy of cilengitide when combined with radiation and temozolomide for patients with newly diagnosed glioblastoma multiforme and to select a dose for comparative clinical testing. METHODS: In total, 112 patients were accrued. Eighteen patients received standard radiation and temozolomide with cilengitide in a safety run-in phase followed by a randomized phase 2 trial with 94 patients assigned to either a 500 mg dose group or 2000 mg dose group. The trial was designed to estimate overall survival benefit compared with a New Approaches to Brain Tumor Therapy (NABTT) Consortium internal historic control and data from the published European Organization for Research and Treatment of Cancer (EORTC) trial EORTC 26981. RESULTS: Cilengitide at all doses studied was well tolerated with radiation and temozolomide. The median survival was 19.7 months for all patients, 17.4 months for the patients in the 500 mg dose group, 20.8 months for patients in the 2000 mg dose group, 30 months for patients who had methylated O6-methylguanine-DNA methyltransferase (MGMT) status, and 17.4 months for patients who had unmethylated MGMT status. For patients aged ≤70 years, the median survival and survival at 24 months was superior to what was observed in the EORTC trial (20.7 months vs 14.6 months and 41% vs 27%, respectively; P = .008). CONCLUSIONS: Cilengitide was well tolerated when combined with standard chemoradiation and may improve survival for patients newly diagnosed with glioblastoma multiforme regardless of MGMT methylation status. The authors concluded that, from an efficacy and safety standpoint, future trials of this agent in this population should use the 2000 mg dose. Cancer 2012. © 2012 American Cancer Society.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
This training video is intended to familiarise researchers and technicians, working with potentially airborne pathogens, on the correct and safe use of Microbiological Safety Cabinets. The video also provides instruction on cleaning, disinfection and fumigation regimes; maintenance and testing regimes; and commissioning and decommissioning requirements of such Local Exhaust Ventilation (LEV) systems. It is in Windows Media Video format which will require a free media player such as Windows Media Player or VLC Media Player (http://www.videolan.org/vlc/) to watch.
Resumo:
Friction plays a key role in causing slipperiness as a low coefficient of friction on the road may result in slippery and hazardous conditions. Analyzing the strong relation between friction and accident risk on winter roads is a difficult task. Many weather forecasting organizations use a variety of standard and bespoke methods to predict the coefficient of friction on roads. This article proposes an approach to predict the extent of slipperiness by building and testing an expert system. It estimates the coefficient of friction on winter roads in the province of Dalarna, Sweden using the prevailing weather conditions as a basis. Weather data from the road weather information system, Sweden (RWIS) was used. The focus of the project was to use the expert system as a part of a major project in VITSA, within the domain of intelligent transport systems
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Since the 1950s, fatigue is the most important project and operational consideration for both civil and military aircrafts. For some aircraft models the most loaded component is one that supports the motor: the Motor Cradle. Because they are considered critical to the flight safety the aeronautic standards are extremely rigorous in manufacturing them by imposing a zero index of defects on the final weld quality (Safe Life), which is 100% inspected by Non-Destructive Testing/NDT. This study has as objective to evaluate the effects of up to four successive TIG welding repairs on the axial fatigue strength of an AISI 4130 steel. Tests were conducted on hot-rolled steel plate specimens, 0.89 mm thick, with load ratio R = 0.1, constant amplitude, at 20 Hz frequency and in room temperature, in accordance with ASTM E466 Standard. The results were related to microhardness and microstructural and geometric changes resulting from welding cycles.
Resumo:
Drug testing is used by employers to detect drug use by employees or job candidates. It can identify recent use of alcohol, prescription drugs, and illicit drugs as a screening tool for potential health and safety and performance issues. Urine is the most commonly used sample for illicit drugs. It detects the use of a drug within the last few days and as such is evidence of recent use; but a positive test does not necessarily mean that the individual was impaired at the time of the test. Abstention from use for three days will often produce a negative test result. Analysis of hair provides a much longer window of detection, typically 1 to 3 months. Hence the likelihood of a falsely negative test using hair is very much less than with a urine test. Conversely, a negative hair test is a substantially stronger indicator of a non-drug user than a negative urine test. Oral fluid (saliva) is also easy to collect. Drugs remain in oral fluid for a similar time as in blood. The method is a good way of detecting current use and is more likely to reflect current impairment. It offers promise as a test in post-accident, for cause, and on-duty situations. Studies have shown that within the same industrial settings, hair testing can detect twice as many drug users as urine testing. Copyright (C) 2012 John Wiley & Sons, Ltd.
Resumo:
The objective of this thesis is the power transient analysis concerning experimental devices placed within the reflector of Jules Horowitz Reactor (JHR). Since JHR material testing facility is designed to achieve 100 MW core thermal power, a large reflector hosts fissile material samples that are irradiated up to total relevant power of 3 MW. MADISON devices are expected to attain 130 kW, conversely ADELINE nominal power is of some 60 kW. In addition, MOLFI test samples are envisaged to reach 360 kW for what concerns LEU configuration and up to 650 kW according to HEU frame. Safety issues concern shutdown transients and need particular verifications about thermal power decreasing of these fissile samples with respect to core kinetics, as far as single device reactivity determination is concerned. Calculation model is conceived and applied in order to properly account for different nuclear heating processes and relative time-dependent features of device transients. An innovative methodology is carried out since flux shape modification during control rod insertions is investigated regarding the impact on device power through core-reflector coupling coefficients. In fact, previous methods considering only nominal core-reflector parameters are then improved. Moreover, delayed emissions effect is evaluated about spatial impact on devices of a diffuse in-core delayed neutron source. Delayed gammas transport related to fission products concentration is taken into account through evolution calculations of different fuel compositions in equilibrium cycle. Provided accurate device reactivity control, power transients are then computed for every sample according to envisaged shutdown procedures. Results obtained in this study are aimed at design feedback and reactor management optimization by JHR project team. Moreover, Safety Report is intended to utilize present analysis for improved device characterization.
Resumo:
OBJECTIVES: To assess the safety and cardiopulmonary adaptation to high altitude exposure among patients with coronary artery disease. METHODS: 22 patients (20 men and 2 women), mean age 57 (SD 7) years, underwent a maximal, symptom limited exercise stress test in Bern, Switzerland (540 m) and after a rapid ascent to the Jungfraujoch (3454 m). The study population comprised 15 patients after ST elevation myocardial infarction and 7 after a non-ST elevation myocardial infarction 12 (SD 4) months after the acute event. All patients were revascularised either by percutaneous coronary angioplasty (n = 15) or by coronary artery bypass surgery (n = 7). Ejection fraction was 60 (SD 8)%. beta blocking agents were withheld for five days before exercise testing. RESULTS: At 3454 m, peak oxygen uptake decreased by 19% (p < 0.001), maximum work capacity by 15% (p < 0.001) and exercise time by 16% (p < 0.001); heart rate, ventilation and lactate were significantly higher at every level of exercise, except at maximum exertion. No ECG signs of myocardial ischaemia or significant arrhythmias were noted. CONCLUSIONS: Although oxygen demand and lactate concentrations are higher during exercise at high altitude, a rapid ascent and submaximal exercise can be considered safe at an altitude of 3454 m for low risk patients six months after revascularisation for an acute coronary event and a normal exercise stress test at low altitude.
Resumo:
The Nursing Home Survey on Patient Safety Culture (NHSPSC) was specifically developed for nursing homes to assess a facility’s safety climate and it consists of 12 dimensions. After its pilot testing, however, no fur- ther psychometric analyses were performed on the instrument. For this study of safety climate in Swiss nursing home units, the NHSPSC was linguistically adapted to the Swiss context and to address the unit as well as facility level, with the aim of testing aspects of the validity and reliability of the Swiss version before its use in Swiss nursing home units. Psychometric analyses were performed on data from 367 nurs- ing personnel from nine nursing homes in the German-speaking part of Switzerland (response rate = 66%), and content validity (CVI) examined. The statistical influence of unit membership on respondents’ answers, and on their agreement concerning their units’ safety climate, was tested using intraclass corre- lation coefficients (ICCs) and the rWG(J) interrater agreement index. A multilevel exploratory factor analysis (MEFA) with oblimin rotation was applied to examine the questionnaire’s dimensionality. Cronbach’s alpha and Raykov’s rho were calculated to assess factor reliability. The relationship of safety climate dimensions with clinical outcomes was explored. Expert feedback confirmed the relevance of the instru- ment’s items (CVI = 0.93). Personnel showed strong agreement in their perceptions in three dimensions of the questionnaire. ICCs supported a multilevel analysis. MEFA produced nine factors at the within-level (in comparison to 12 in the original version) and two factors at the between-level with satisfactory fit statis- tics. Raykov’s Rho for the single level factors ranged between 0.67 and 0.86. Some safety climate dimen- sions show moderate, but non-significant correlations with the use of bedrails, physical restraint use, and fall-related injuries. The Swiss version of the NHSPSC needs further refinement and testing before its use can be recommended in Swiss nursing homes: its dimensionality needs further clarification, particularly to distinguish items addressing the unit-level safety climate from those at the facility level.
Resumo:
BACKGROUND Up to one third of BKP treated cases shows no appreciable height restoration due to loss of both restored height and kyphotic realignment after balloon deflation. This shortcoming has called for an improved method that maintains the height and realignment reached by the fully inflated balloon until stabilization of the vertebral body by PMMA-based cementation. Restoration of the physiological vertebral body height for pain relief and for preventing further fractures of adjacent and distant vertebral bodies must be the main aim for such a method. A new vertebral body stenting system (VBS) stabilizes the vertebral body after balloon deflation until cementation. The radiographic and safety results of the first 100 cases where VBS was applied are presented. METHODS During the planning phase of an ongoing international multicenter RCT, radiographic, procedural and followup details were retrospectively transcribed from charts and xrays for developing and testing the case report forms. Radiographs were centrally assessed at the institution of the first/senior author. RESULTS 100 patients (62 with osteoporosis) with a total of 103 fractured vertebral bodies were treated with the VBS system. 49 were females with a mean age of 73.2 years; males were 66.7 years old. The mean preoperative anterior-middle-posterior heights were 20.3-17.6-28.0 mm, respectively. The mean local kyphotic angle was 13.1[degree sign]. The mean preoperative Beck Index (anterior edge height/posterior edge height) was 0.73, the mean alternative Beck Index (middle height/posterior edge height) was 0.63. The mean postoperative heights were restored to 24.5-24.6-30.4 mm, respectively. The mean local kyphotic angle was reduced to 8.9[degree sign]. The mean postoperative Beck Index was 0.81, the mean alternative one was 0.82. The overall extrusion rate was 29.1%, the symptomatic one was 1%. In the osteoporosis subgroup there were 23.8% extrusions. Within the three months followup interval there were 9% of adjacent and 4% of remote new fractures, all in the osteoporotic group. CONCLUSIONS VBS showed its strengths especially in realignment of crush and biconcave fractures. Given that fracture mobility is present, the realignment potential is sound and increases with the severity of preoperative vertebral body deformation.