936 resultados para SYNTHETIC MESH


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless mesh networks present an attractive communication solution for various research and industrial projects. However, in many cases, the appropriate preliminary calculations which allow predicting the network behavior have to be made before the actual deployment. For such purposes, network simulation environments emulating the real network operation are often used. Within this paper, a behavior comparison of real wireless mesh network (based on 802.11s amendment) and the simulated one has been performed. The main objective of this work is to measure performance parameters of a real 802.11s wireless mesh network (average UDP throughput and average one-way delay) and compare the derived results with characteristics of a simulated wireless mesh network created with the NS-3 network simulation tool. Then, the results from both networks are compared and the corresponding conclusion is made. The corresponding results were derived from simulation model and real-worldtest-bed, showing that the behavior of both networks is similar. It confirms that the NS-3 simulation model is accurate and can be used in further research studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest projecte presenta la implementació d'un disseny, i la seva posterior síntesi en una FPGA, d'una arquitectura de tipus wormhole packet switching per a una infraestructura de NetWork-On-Chip amb una topologia 2D-Mesh. Agafant un router circuit switching com a punt de partida, s'han especificat els mòduls en Verilog per tal d'obtenir l'arquitectura wormhole desitjada. Dissenyar la màquina de control per governar els flits que conformen els paquets dins la NoC,i afegir les cues a la sortida del router (outuput queuing) són els punts principals d'aquest treball. A més, com a punt final s'han comparat ambdues arquitectures de router en termes de costos en àrea i en memòria i se n’han obtingut diverses conclusions i resultats experimentals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest projecte presenta una avaluació de les diferents alternatives d'encaminament per a una NoC amb una topologia mesh 2D. Per tal d'exposar aquestes alternatives s'ha estudiat la composició d'un router implementat amb l'algorisme determinista XY i s'ha adaptat per tal que aquest suportés els algorismes parcialment adaptatius West First, North Last i Negative First. Un cop tenim els routers implementats es disposa un estudi dels diferents algorismes i com cadascun d'aquests actuen en front uns mateixos estímuls per tal de crear una comparativa entre ells que ens faciliti una elecció a priori.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vaccines have been used as a successful tool in medicine by way of controlling many major diseases. In spite of this, vaccines today represent only a handful of all infectious diseases. Therefore, there is a pressing demand for improvements of existing vaccines with particular reference to higher efficacy and undisputed safety profiles. To this effect, as an alternative to available vaccine technologies, there has been a drive to develop vaccine candidate polypeptides by chemical synthesis. In our laboratory, we have recently developed a technology to manufacture long synthetic peptides of up to 130 residues, which are correctly folded and biologically active. This paper discusses the advantages of the molecularly defined, long synthetic peptide approach in the context of vaccine design, development and use in human vaccination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The review covers the development of synthetic peptides as vaccine candidates for Plasmodium falciparum- and Plasmodium vivax-induced malaria from its beginning up to date and the concomitant progress of solid phase peptide synthesis (SPPS) that enables the production of long peptides in a routine fashion. The review also stresses the development of other complementary tools and actions in order to achieve the long sought goal of an efficacious malaria vaccine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The immunogenicity of a novel synthetic peptide consisting of an average of 40 (Asn-Ala-Asn-Pro) repeats of the circumsporozoite protein of Plasmodium falciparum, (NANP)40, was studied in mice without using any carrier proteins. First, high titers of anti-(NANP)40 antibodies could be obtained after immunization of C57BL/6 mice. These antibodies also reacted with an extract of mosquitoes infected with P. falciparum sporozoites. C57BL/6 nu/nu mice did not produce antibodies against (NANP)40. Secondly, when 14 strains of mice with nine different H-2 haplotypes were immunized with (NANP)40 without carrier, only H-2b mice were found to produce anti-(NANP)40 antibodies, whereas all non-H-2b mice were consistently unresponsive. This response was demonstrated to be I-A-linked by using recombinant and mutant mice. I-Ab [B10.A(5R)] mice produced anti-(NANP)40 antibodies as well as H-2b inbred mice. B6CH-2bm12 I-Ab-mutant mice showed only a very low response. Third, the antibody response against (NANP)40 could be induced in nonresponder mice by immunization with the peptide coupled to a carrier protein. In view of the existence of such an exceptional H-2b restriction in the response to sporozoite synthetic peptides in mice, the triggering of peptide-specific T cell responses in humans receiving sporozoite malaria vaccines might be difficult to achieve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibrin sealing has recently evolved as a new technique for mesh fixation in endoscopic inguinal hernia repair. A comprehensive Medline search was carried out evaluating fibrin sealant for mesh fixation, and finally 12 studies were included (3 randomized trials, 3 nonrandomized trials, and 6 case series). The trials were assessed for operative time, seroma formation, recovery time, recurrence rate, and acute and chronic pain.There was a trend toward decreased operative times for fibrin sealing compared with mechanical stapling; however, the results for seroma formation remained contradictory. The most important finding was the reduced postoperative pain. Recovery times were lower after fibrin sealing and the recurrence rates showed no differences.Fibrin sealing for mesh fixation in the endoscopic inguinal hernia surgery is a promising alternative to mechanical stapling, which can be safely applied. As the overall quality of published data remains poor, further well-designed studies are needed until fibrin sealing can replace mechanical stapling as a new standard for mesh fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficient HIV vaccines have to trigger cell-mediated immunity directed against various viral antigens. However little is known about the breadth of the response induced by vaccines carrying multiple proteins. Here, we report on the immunogenicity of a construct harbouring a fusion of the HIV-1 IIIB gag, pol and nef genes (gpn) designed for optimal safety and equimolar expression of the HIV proteins. The attenuated poxviruses, MVA and NYVAC, harbouring the gpn construct, induced potent immune responses in conventional mice characterised by stimulation of Gpn-specific IFN-gamma-producing cells and cytotoxic T cells. In HLA-A2 transgenic mice, recombinant MVA elicited cytotoxic responses against epitopes recognised in most HLA-A2+ HIV-1-infected individuals. We also found that the MVA vaccine triggered the in vitro expansion of peripheral blood cells isolated from a HIV-1-seropositive patient and with similar specificity as found in immunised HLA-A2 transgenic mice. In conclusion, the synthetic HIV polyantigen Gpn delivered by MVA is immunogenic, efficiently processed and presented by human MHC class I molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Clinical small-caliber vascular prostheses are unsatisfactory. Reasons for failure are early thrombosis and late intimal hyperplasia. We thus prepared biodegradable small-caliber vascular prostheses using electrospun polycaprolactone (PCL) with slow-releasing paclitaxel (PTX), an antiproliferative drug. METHODS AND RESULTS: PCL solutions containing PTX were used to prepare nonwoven nanofibre-based 2-mm ID prostheses. Mechanical morphological properties and drug loading, distribution, and release were studied in vitro. Infrarenal abdominal aortic replacement was carried out with nondrug-loaded and drug-loaded prostheses in 18 rats and followed for 6 months. Patency, stenosis, tissue reaction, and drug effect on endothelialization, vascular remodeling, and neointima formation were studied in vivo. In vitro prostheses showed controlled morphology mimicking extracellular matrix with mechanical properties similar to those of native vessels. PTX-loaded grafts with suitable mechanical properties and controlled drug-release were obtained by factorial design. In vivo, both groups showed 100% patency, no stenosis, and no aneurysmal dilatation. Endothelial coverage and cell ingrowth were significantly reduced at 3 weeks and delayed at 12 and 24 weeks in PTX grafts, but as envisioned, neointima formation was significantly reduced in these grafts at 12 weeks and delayed at 6 months. CONCLUSIONS: Biodegradable, electrospun, nanofibre, polycaprolactone prostheses are promising because in vitro they maintain their mechanical properties (regardless of PTX loading), and in vivo show good patency, reendothelialize, and remodel with autologous cells. PTX loading delays endothelialization and cellular ingrowth. Conversely, it reduces neointima formation until the end point of our study and thus may be an interesting option for small caliber vascular grafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of synthetic P. falciparum (NANP)n circumsporozoite peptides to elicit murine T cell proliferative responses was studied. When C57BL/6, C3H, and DBA/2 mice were injected with (NANP)40, only C57BL/6 (H-2b)-immune lymph node cells proliferated on restimulation in vitro with the same peptide. By using anti-I-A monoclonal antibodies or spleen cells from congenic H-2b mice as a source of antigen-presenting cells, the T cell proliferative response was shown to be restricted to the I-Ab region of the C57BL/6 haplotype. These results are in agreement with previous experiments which demonstrated that the anti-(NANP)40 antibody response was uniquely restricted to C57BL/6 (H-2b) mice. Several C57BL/6 long-term (NANP)n-specific T cell lines and clones were derived. All of the clones exhibited the L3T4 helper T cell phenotype. A considerable heterogeneity of T cell responses was observed when the lines and clones were stimulated with different concentrations of the various peptides studied. The results, together with the observed genetic restriction for both antibody and T cell responses, suggest that perhaps not all individuals who receive a similar repetitive tetrapeptide sporozoite malaria vaccine will develop T cell and or antibody responses.