911 resultados para SIMPLE method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

(Gt. Brit. Air survey committee. Professional papers, no. 8 Supplement)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Univariate linkage analysis is used routinely to localise genes for human complex traits. Often, many traits are analysed but the significance of linkage for each trait is not corrected for multiple trait testing, which increases the experiment-wise type-I error rate. In addition, univariate analyses do not realise the full power provided by multivariate data sets. Multivariate linkage is the ideal solution but it is computationally intensive, so genome-wide analysis and evaluation of empirical significance are often prohibitive. We describe two simple methods that efficiently alleviate these caveats by combining P-values from multiple univariate linkage analyses. The first method estimates empirical pointwise and genome-wide significance between one trait and one marker when multiple traits have been tested. It is as robust as an appropriate Bonferroni adjustment, with the advantage that no assumptions are required about the number of independent tests performed. The second method estimates the significance of linkage between multiple traits and one marker and, therefore, it can be used to localise regions that harbour pleiotropic quantitative trait loci (QTL). We show that this method has greater power than individual univariate analyses to detect a pleiotropic QTL across different situations. In addition, when traits are moderately correlated and the QTL influences all traits, it can outperform formal multivariate VC analysis. This approach is computationally feasible for any number of traits and was not affected by the residual correlation between traits. We illustrate the utility of our approach with a genome scan of three asthma traits measured in families with a twin proband.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new and simple fabrication technique is reported for the UV inscription of intrinsically apodized chirped fibre gratings at an arbitrary Bragg wavelength employing a single chirped phase-mask in a scanning Talbot interferometer set-up. Chirped gratings have been successfully produced over a large wavelength range and with bandwidths up to 5 nm. These gratings exhibit the time-delay response of a small ripple effect. In the present paper a comparison with previously reported fabrication methods is given, showing the advantages and disadvantages of the different methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new simple test method using small scale models has been developed for testing profiled steel cladding systems under wind uplift/suction forces. This simple method should replace the large scale test method using two-span claddings used at present. It can be used for roof or wall cladding systems fastened with screw fasteners at crests or valleys.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective Surveillance programs and research for acute respiratory infections in remote Aboriginal communities are complicated by difficulties in the storage and transport of frozen samples to urban laboratories for testing. This study assessed the sensitivity of a simple method for transporting respiratory samples from a remote setting for viral PCR compared with frozen specimens. Methods We sampled every individual who presented to a remote Aboriginal community clinic in a non-epidemic respiratory season. Two anterior nasal swabs were collected from each participant. The left nare specimen was mailed to the laboratory via routine postal services. The right nare specimen was transported frozen. Testing for 16 viruses was undertaken using real-time multiplex PCR. Results A total of 140 participants were enrolled who contributed 150 study visits. Respiratory illnesses accounted for 10% of the reasons for presentation. Sixty-one viruses were identified in 50 (33.3%) presentations for 40 (28.6%) individuals; bocavirus and rhinovirus were the most common viruses identified (14.0% and 12.6% of episodes respectively). The sensitivity for any virus detected in mailed specimens was 67.2% (95%CI 55.4, 78.9) compared to 65.6% (95%CI 53.7, 77.5) for frozen specimens. Conclusion The mailing of unfrozen nasal specimens from remote communities does not compromise the viability of the specimen for viral studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A sensitive and simple method for quantification of antibodies against small molecules is described using DNP-lysozyme as the enzyme conjugate. The anti-DNP antiserum was raised against DNP-bovin serum albumin conjugate. Anti-DNP antibody or its monovalent fragment (Fab) reduced the enzyme activity of DNP-lysozyme conjugate in a concentration-dependent manner. The inhibition of enzyme activity is a specific measure of the antibody and Fab content of the sample. The specificity of the reaction was assessed by reduction of antibody-induced inhibition by DNP-lysine. The ability of DNP-lysine to reduce the antibody-induced inhibition of DNP-lysozyme activity also makes possible a sensitive assay for DNP-lysine.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Three-dimensional effects are a primary source of discrepancy between the measured values of automotive muffler performance and those predicted by the plane wave theory at higher frequencies. The basically exact method of (truncated) eigenfunction expansions for simple expansion chambers involves very complicated algebra, and the numerical finite element method requires large computation time and core storage. A simple numerical method is presented in this paper. It makes use of compatibility conditions for acoustic pressure and particle velocity at a number of equally spaced points in the planes of the junctions (or area discontinuities) to generate the required number of algebraic equations for evaluation of the relative amplitudes of the various modes (eigenfunctions), the total number of which is proportional to the area ratio. The method is demonstrated for evaluation of the four-pole parameters of rigid-walled, simple expansion chambers of rectangular as well as circular cross-section for the case of a stationary medium. Computed values of transmission loss are compared with those computed by means of the plane wave theory, in order to highlight the onset (cutting-on) of various higher order modes and the effect thereof on transmission loss of the muffler. These are also compared with predictions of the finite element methods (FEM) and the exact methods involving eigenfunction expansions, in order to demonstrate the accuracy of the simple method presented here.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Establishing fabrication methods of carbon nanotubes (CNTs) is essential to realize many applications expected for CNTs. Catalytic growth of CNTs on substrates by chemical vapor deposition (CVD) is promising for direct fabrication of CNT devices, and catalyst nanoparticles play a crucial role in such growth. We have developed a simple method called "combinatorial masked deposition (CMD)", in which catalyst particles of a given series of sizes and compositions are formed on a single substrate by annealing gradient catalyst layers formed by sputtering through a mask. CMD enables preparation of hundreds of catalysts on a wafer, growth of single-walled CNTs (SWCNTs), and evaluation of SWCNT diameter distributions by automated Raman mapping in a single day. CMD helps determinations of the CVD and catalyst windows realizing millimeter-tall SWCNT forest growth in 10 min, and of growth curves for a series of catalysts in a single measurement when combined with realtime monitoring. A catalyst library prepared using CMD yields various CNTs, ranging from individuals, networks, spikes, and to forests of both SWCNTs and multi-walled CNTs, and thus can be used to efficiently evaluate self-organized CNT field emitters, for example. The CMD method is simple yet effective for research of CNT growth methods. © 2010 The Japan Society of Applied Physics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple method for the fabrication of Pd nanoparticles is described. The three-dimensional Pd nanoparticle films are directly formed on a gold electrode surface by simple electrodeposition at -200 mV from a solution of 1 M H2SO4+0.01 mM K2PdCl4. X-Ray photoelectron spectroscopy verifies the constant composition of the Pd nanoparticle films. Atomic force microscopy proves that the as-prepared Pd nanoparticles are uniformly distributed with an average particle diameter of 45-60 nm. It is confirmed that the morphology of the Pd nanoparticle films are correlated with the electrodeposition time and the state of the Au substrate. The resulting Pd-nanoparticle-film-modified electrode possesses high catalytic activity for the reduction of dissolved oxygen in 0.1 M KCl solution. Freshly prepared Pd nanoparticles can catalyze the reduction of O-2 by a 4-electron process at -200 mV in 0.1 M KCl, but this system is not very stable. The cathodic peaks corresponding to the reduction of O-2 gradually decrease with potential cycling and at last reach a steady state. Then two well-defined reduction peaks are observed at -390 and -600 mV vs. Ag/AgCl/KCl (sat.). Those two peaks correspond to a 2-step process for the 4-electron reduction pathway of O-2 in this neutral medium.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissolved inorganic carbon (DIC) account for more than 95% of total carbon in seawater, so it is necessary to make reliable and precise measurements of DIC to study marine carbon cycling. In order to establish a simple and speed method, an airproof device of gas extraction-absorption was designed. Finally a simple method was developed for the determination of DIC in seawater through a large mount of experiments. The determination procedure is as follows: 100 similar to 150 mL seawater was put into conical flask, then add 10% H3PO4, the DIC in seawater sample was dissolved to form CO2 gas and carried by pure N-2, then the CO2 gas was absorbed by two grades 0.1 mol/L NaOH solution. Finally the absorbed solution was titrated by HCl standard solution of 0.01000 mol/L with the end points detected with the indicator phenolphthalein and bromocresol green-methyl red mixture. The precision and accuracy of the method were satisfied. This method was used to analyse seawater samples from Jiaozhou bay in June, 2003. The result shows that the average DIC in surface seawater is 2066 mumol/L, DIC in bottom seawater is 2075 mumol/L inside bay, but the average DIC in surface seawater is 1949 mumol/L, DIC in bottom seawater is 2147 mumol/L outside bay.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Here we describe a novel, inexpensive and simple method for preserving RNA that reduces handling stress in aquatic invertebrates following ecotoxicogenomic experimentation. The application of the method is based on transcriptomic experiments conducted on Daphnia magna, but may easily be applied on a range of other aquatic organisms of a particular size with e.g. amphipod Gammarus pulex representing an upper size limit. We explain in detail how to apply this new method, named the "Cylindrical Sieve (CS) system", and highlight its advantages and disadvantages.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new simple method for two-dimensional determination of optical density of macular pigment xanthophyll (ODx) in clinical routine is based on a single blue-reflection fundus image. Individual different vignetting is corrected by a shading function. For its construction, nodes are automatically found in structureless image regions. The influence of stray light in elderly crystalline lenses is compensated by a correction function that depends on age. The reproducibility of parameters in a one-wavelength reflection method determined for three subjects (47, 61, and 78 years old) was: maxODx = 6.3%, meanODx = 4.6%, volume = 6%, and area = 6% already before stray-light correction. ODx was comparable in pseudophakic and in an eye with a crystalline lens of the same 11 subjects after stray-light correction. Significant correlation in ODx was found between the one-wavelength reflection method and the two-wavelength autofluorescence method for pseudophakic and cataract eyes of 19 patients suffering from dry age-related macular degeneration (AMD) (R(2) = 0.855). In pseudophakic eyes, maxODx was significantly lower for dry AMD (n = 45) (ODx = 0.491±0.102 ODU) than in eyes with healthy fundus (n = 22) (ODx = 0.615±0.103 ODU) (p = 0.000033). Also in eyes with crystalline lens, maxODx was lower in AMD (n = 125) (ODx = 0.610±0.093 ODU) than in healthy subjects (n = 45) (ODx = 0.674±0.098 ODU) (p = 0.00019). No dependence on age was found in the pseudophakic eyes both of healthy subjects and AMD patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A rapid, highly selective and simple method has been developed for the quantitative determination of pyro-, tri- and orthophosphates. The method is based on the formation of a solid complex of bis(ethylenediamine)cobalt(III) species with pyrophosphate at pH 4.2-4.3, with triphosphate at pH 2.0-2.1 and with orthophosphate at pH 8.2-8.6. The proposed method for pyro- and triphosphates differs from the available method, which is based on the formation of an adduct with tris(ethylenediamine)cobalt(III) species. The complexes have the composition [Co(en)(2)HP2O7]4H(2)O and [Co(en)(2)H2P3O10]2H(2)O, respectively. The precipitation is instantaneous and quantitative under the recommended optimum conditions giving 99.5% gravimetric yield in both cases. There is no interferences from orthophosphate, trimetaphosphate and pyrophosphate species in the triphosphate estimation up to 5% of each component. The efficacy of the method has been established by determining pyrophosphate and triphosphate contents in various matrices. In the case of orthophosphate, the proposed method differs from the available methods such as ammonium phosphomolybdate, vanadophosphomolybdate and quinoline phosphomolybdate, which are based on the formation of a precipitate, followed by either titrimetry or gravimetry. The precipitation is instantaneous and the method is simple. Under the recommended pH and other reaction conditions, gravimetric yields of 99.6-100% are obtainable. The method is applicable to orthophosphoric acid and a variety of phosphate salts.