114 resultados para SCADA
Resumo:
The need to implement a software architecture that promotes the development of a SCADA supervisory system for monitoring industrial processes simulated with the flexibility of adding intelligent modules and devices such as CLP, according to the specifications of the problem, it was the motivation for this work. In the present study, we developed an intelligent supervisory system on a simulation of a distillation column modeled with Unisim. Furthermore, OLE Automation was used as communication between the supervisory and simulation software, which, with the use of the database, promoted an architecture both scalable and easy to maintain. Moreover, intelligent modules have been developed for preprocessing, data characteristics extraction, and variables inference. These modules were fundamentally based on the Encog software
Resumo:
Embedded systems are widely spread nowadays. An example is the Digital Signal Processor (DSP), which is a high processing power device. This work s contribution consist of exposing DSP implementation of the system logic for detecting leaks in real time. Among the various methods of leak detection available today this work uses a technique based on the pipe pressure analysis and usesWavelet Transform and Neural Networks. In this context, the DSP, in addition to do the pressure signal digital processing, also communicates to a Global Positioning System (GPS), which helps in situating the leak, and to a SCADA, sharing information. To ensure robustness and reliability in communication between DSP and SCADA the Modbus protocol is used. As it is a real time application, special attention is given to the response time of each of the tasks performed by the DSP. Tests and leak simulations were performed using the structure of Laboratory of Evaluation of Measurement in Oil (LAMP), at Federal University of Rio Grande do Norte (UFRN)
Resumo:
One of the most important decisions to turn a substation automatic and no attended it relates to the communication media between this substation and Operation Center. Generally energy companies uses radio or optic fiber, depending of distances and infrastructure of each situation. This rule applies to common substations. Mobile substations are a particular case, therefore they are conceived for use at provisional situations, emergencies, preventive or corrective maintenance. Thus the telecommunication solution used at common substations are not applied so easily to mobile substations, due absence of infrastructure (media) or difficulty to insert the mobile substation data in existing automation network not long. The ideal media must supply covering in a great geographic area to satisfy presented requirements. The implantation costs of this big infrastructure are expensive, however a existing operator may be used. Two services that fulfill that requirements are satellite and cellular telephony. This work presents a solution for automation of mobile substations through satellite. It was successfully implanted at a brazilian electric energy concessionaire named COSERN. The operation became transparent to operators. Other gotten benefits had been operational security, quality in the supply of electric energy and costs reduction. The project presented is a new solution, designed to substations and general applications where few data should be transmitted, but there is difficulties in relation to the media. Despite the satellite having been used, the same resulted can be gotten using celullar telephony, through Short Messages or packet networks as GPRS or EDGE.
Resumo:
The using of supervision systems has become more and more essential in accessing, managing and obtaining data of industrial processes, because of constant and frequent developments in industrial automation. These supervisory systems (SCADA) have been widely used in many industrial environments to store process data and to control the processes in accordance with some adopted strategy. The SCADA s control hardware is the set of equipments that execute this work. The SCADA s supervision software accesses process data through the control hardware and shows them to the users. Currently, many industrial systems adopt supervision softwares developed by the same manufacturer of the control hardware. Usually, these softwares cannot be used with other equipments made by distinct manufacturers. This work proposes an approach for developing supervisory systems able to access process information through different control hardwares. An architecture for supervisory systems is first defined, in order to guarantee efficiency in communication and data exchange. Then, the architecture is applied in a supervisory system to monitor oil wells that use distinct control hardwares. The implementation was modeled and verified by using the formal method of the Petri networks. Finally, experimental results are presented to demonstrate the applicability of the proposed solution
Resumo:
The need to implement a software architecture that promotes the development of a SCADA supervisory system for monitoring industrial processes simulated with the flexibility of adding intelligent modules and devices such as CLP, according to the specifications of the problem, it was the motivation for this work. In the present study, we developed an intelligent supervisory system on a simulation of a distillation column modeled with Unisim. Furthermore, OLE Automation was used as communication between the supervisory and simulation software, which, with the use of the database, promoted an architecture both scalable and easy to maintain. Moreover, intelligent modules have been developed for preprocessing, data characteristics extraction, and variables inference. These modules were fundamentally based on the Encog software
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In February 2011, the National Agency of Petroleum, Natural Gas and Biofuels (ANP) has published a new Technical Rules for Handling Land Pipeline Petroleum and Natural Gas Derivatives (RTDT). Among other things, the RTDT made compulsory the use of monitoring systems and leak detection in all onshore pipelines in the country. This document provides a study on the method for detection of transient pressure. The study was conducted on a industrial duct 16" diameter and 9.8 km long. The pipeline is fully pressurized and carries a multiphase mixture of crude oil, water and natural gas. For the study, was built an infrastructure for data acquisition and validation of detection algorithms. The system was designed with SCADA architecture. Piezoresistive sensors were installed at the ends of the duct and Digital Signal Processors (DSPs) were used for sampling, storage and processing of data. The study was based on simulations of leaks through valves and search for patterns that characterize the occurrence of such phenomena
Resumo:
In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Neste trabalho são apresentados os resultados de uma técnica que permitiu implementar a estratégia de controle de temperatura do aquecedor de óleo térmico da fabrica de Anodo Verde da Albrás Alumínio Brasileiro S/A. No projeto utilizou-se um sistema hierarquizado baseado em conjuntos e lógica Fuzzy. O uso dessa metodologia fez com que o sistema fosse capaz de reagir adequadamente diante das variações do ponto de operação do aquecedor, pois o controle Fuzzy exibe algumas características do aprendizado humano, sendo considerado um exemplo de inteligência artificial. O aquecedor de óleo térmico é fundamental no processo de fabricação de blocos inódicos, utilizados como pólo positivo no processo de eletrólise na obtenção do alumínio primário. O sistema de óleo térmico aquece os misturadores e pré-aquecedor de coque, mantendo a temperatura desses equipamentos dentro dos limites estabelecidos pela engenharia de processo. A variável temperatura impacta diretamente na energia de mistura da pasta e na qualidade do produto final, que é o bloco anódico. A metodologia apresentada permitiu alcançar um controle de temperatura que atendeu satisfatoriamente os parâmetros de processo. O programa foi desenvolvido em linguagem ladder é executado em controladores lógicos programáveis (CLP’S) da Rockwell Automation. O controle já está em plena operação nas fábricas de anodos e os resultados obtidos demonstram a eficácia e viabilidade do sistema, que futuramente estará sendo implementado no controle de outros equipamentos da Albrás.
Resumo:
In Smart Grids, a variety of new applications are available to users of the electrical system (from consumers to the electric system operators and market operators). Some applications such as the SCADA systems, which control generators or substations, have consequences, for example, with a communication delay. The result of a failure to deliver a control message due to noncompliance of the time constraint can be catastrophic. On the other hand, applications such as smart metering of consumption have fewer restrictions. Since each type of application has different quality of service requirements (importance, delay, and amount of data to transmit) to transmit its messages, the policy to control and share the resources of the data communication network must consider them. In this paper Markov Decision Process Theory is employed to determine optimal policies to explore as much as possible the availability of throughput in order to transmit all kinds of messages, considering the quality of service requirements defined to each kind of message. First a non-preemptive model is formulated and after that a preemptive model is derived. Numerical results are used to compare FIFO, non-preemptive and preemptive policies.
Resumo:
A presente dissertação visa apresentar um conjunto de desenvolvimentos, aplicativos e serviços para suporte à operação em tempo real e ao controle preventivo visando garantir à segurança estática e dinâmica de sistemas elétricos de potência. A técnica de mineração de dados conhecida como árvore de decisão foi utilizada tanto para classificar o estado operacional do sistema, bem como para fornecer diretrizes à tomada de ações de controle, necessárias para evitar a degradação da tensão operativa e a instabilidade transitória. Testes preliminares foram realizados utilizando o histórico operacional do SCADA/SAGE do Centro de Operação Regional do Pará da Eletrobrás Eletronorte. Os resultados obtidos validaram completamente o conjunto (protótipo) de aplicativos e serviços, e indicam um grande potencial para a aplicação no ambiente de operação em tempo real.