953 resultados para Right cardiac catheterization


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To identify and appraise the literature concerning nurse-administered procedural sedation and analgesia in the cardiac catheter laboratory. Design and data sources: An integrative review method was chosen for this study. MEDLINE and CINAHL databases as well as The Cochrane Database of Systematic Reviews and the Joanna Briggs Institute were searched. Nineteen research articles and three clinical guidelines were identified. Results: The authors of each study reported nurse-administered sedation in the CCL is safe due to the low incidence of complications. However, a higher percentage of deeply sedated patients were reported to experience complications than moderately sedated patients. To confound this issue, one clinical guideline permits deep sedation without an anaesthetist present, while others recommend against it. All clinical guidelines recommend nurses are educated about sedation concepts. Other findings focus on pain and discomfort and the cost-savings of nurse-administered sedation, which are associated with forgoing anaesthetic services. Conclusions: Practice is varied due to limitations in the evidence and inconsistent clinical practice guidelines. Therefore, recommendations for research and practice have been made. Research topics include determining how and in which circumstances capnography can be used in the CCL, discerning the economic impact of sedation-related complications and developing a set of objectives for nursing education about sedation. For practice, if deep sedation is administered without an anaesthetist present, it is essential nurses are adequately trained and have access to vital equipment such as capnography to monitor ventilation because deeply sedated patients are more likely to experience complications related to sedation. These initiatives will go some way to ensuring patients receiving nurse-administered procedural sedation and analgesia for a procedure in the cardiac catheter laboratory are cared for using consistent, safe and evidence-based practices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims and objectives To explore issues and challenges associated with nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory from the perspectives of senior nurses. Background Nurses play an important part in managing sedation because the prescription is usually given verbally directly from the cardiologist who is performing the procedure and typically, an anaesthetist is not present. Design A qualitative exploratory design was employed. Methods Semi-structured interviews with 23 nurses from 16 cardiac catheterisation laboratories across four states in Australia and also New Zealand were conducted. Data analysis followed the guide developed by Braun and Clark to identify the main themes. Results Major themes emerged from analysis regarding the lack of access to anaesthetists, the limitations of sedative medications, the barriers to effective patient monitoring and the impact that the increasing complexity of procedures has on patients' sedation requirements. Conclusions The most critical issue identified in this study is that current guidelines, which are meant to apply regardless of the clinical setting, are not practical for the cardiac catheterisation laboratory due to a lack of access to anaesthetists. Furthermore, this study has demonstrated that nurses hold concerns about the legitimacy of their practice in situations when they are required to perform tasks outside of clinical practice guidelines. To address nurses' concerns, it is proposed that new guidelines could be developed, which address the unique circumstances in which sedation is used in the cardiac catheterisation laboratory. Relevance to clinical practice Nurses need to possess advanced knowledge and skills in monitoring for the adverse effects of sedation. Several challenges impact on nurses' ability to monitor patients during procedural sedation and analgesia. Preprocedural patient education about what to expect from sedation is essential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Side effects of the medications used for procedural sedation and analgesia in the cardiac catheterisation laboratory are known to cause impaired respiratory function. Impaired respiratory function poses considerable risk to patient safety as it can lead to inadequate oxygenation. Having knowledge about the conditions that predict impaired respiratory function prior to the procedure would enable nurses to identify at-risk patients and selectively implement intensive respiratory monitoring. This would reduce the possibility of inadequate oxygenation occurring. Aim: To identify pre-procedure risk factors for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Design: Retrospective matched case–control. Methods: 21 cases of impaired respiratory function were identified and matched to 113 controls from a consecutive cohort of patients over 18 years of age. Conditional logistic regression was used to identify risk factors for impaired respiratory function. Results: With each additional indicator of acute illness, case patients were nearly two times more likely than their controls to experience impaired respiratory function (OR 1.78; 95% CI 1.19–2.67; p = 0.005). Indicators of acute illness included emergency admission, being transferred from a critical care unit for the procedure or requiring respiratory or haemodynamic support in the lead up to the procedure. Conclusion: Several factors that predict the likelihood of impaired respiratory function were identified. The results from this study could be used to inform prospective studies investigating the effectiveness of interventions for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To develop clinical practice guidelines for nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Background Numerous studies have reported that nurse-administered procedural sedation and analgesia is safe. However, the broad scope of existing guidelines for the administration and monitoring of patients who receive sedation during medical procedures without an anaesthetist presents means there is a lack of specific guidance regarding optimal nursing practices for the unique circumstances in which nurse-administered procedural sedation and analgesia is used in the cardiac catheterisation laboratory. Methods A sequential mixed methods design was utilised. Initial recommendations were produced from three studies conducted by the authors: an integrative review; a qualitative study; and a cross-sectional survey. The recommendations were revised in accordance with responses from a modified Delphi study. The first Delphi round was completed by nine senior cardiac catheterisation laboratory nurses. All but one of the draft recommendations met the pre-determined cut-off point for inclusion. There were a total of 59 responses to the second round. Consensus was reached on all recommendations. Implications for nursing The guidelines that were derived from the Delphi study offer twenty four recommendations within six domains of nursing practice: Pre-procedural assessment; Pre-procedural patient and family education; Pre-procedural patient comfort; Intra-procedural patient comfort; Intra-procedural patient assessment and monitoring; and Post-procedural patient assessment and monitoring. Conclusion These guidelines provide an important foundation towards the delivery of safe, consistent and evidence-based nursing care for the many patients who receive sedation in the cardiac catheterisation laboratory setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose This study evaluated the impact of patient set-up errors on the probability of pulmonary and cardiac complications in the irradiation of left-sided breast cancer. Methods and Materials Using the CMS XiO Version 4.6 (CMS Inc., St Louis, MO) radiotherapy planning system's NTCP algorithm and the Lyman -Kutcher-Burman (LKB) model, we calculated the DVH indices for the ipsilateral lung and heart and the resultant normal tissue complication probabilities (NTCP) for radiation-induced pneumonitis and excess cardiac mortality in 12 left-sided breast cancer patients. Results Isocenter shifts in the posterior direction had the greatest effect on the lung V20, heart V25, mean and maximum doses to the lung and the heart. Dose volume histograms (DVH) results show that the ipsilateral lung V20 tolerance was exceeded in 58% of the patients after 1cm posterior shifts. Similarly, the heart V25 tolerance was exceeded after 1cm antero-posterior and left-right isocentric shifts in 70% of the patients. The baseline NTCPs for radiation-induced pneumonitis ranged from 0.73% - 3.4% with a mean value of 1.7%. The maximum reported NTCP for radiation-induced pneumonitis was 5.8% (mean 2.6%) after 1cm posterior isocentric shift. The NTCP for excess cardiac mortality were 0 % in 100% of the patients (n=12) before and after setup error simulations. Conclusions Set-up errors in left sided breast cancer patients have a statistically significant impact on the Lung NTCPs and DVH indices. However, with a central lung distance of 3cm or less (CLD <3cm), and a maximum heart distance of 1.5cm or less (MHD<1.5cm), the treatment plans could tolerate set-up errors of up to 1cm without any change in the NTCP to the heart.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The incidence of all forms of congenital heart defects is 0.75%. For patients with congenital heart defects, life-expectancy has improved with new treatment modalities. Structural heart defects may require surgical or catheter treatment which may be corrective or palliative. Even those with corrective therapy need regular follow-up due to residual lesions, late sequelae, and possible complications after interventions. Aims: The aim of this thesis was to evaluate cardiac function before and after treatment for volume overload of the right ventricle (RV) caused by atrial septal defect (ASD), volume overload of the left ventricle (LV) caused by patent ductus arteriosus (PDA), and pressure overload of the LV caused by coarctation of the aorta (CoA), and to evaluate cardiac function in patients with Mulibrey nanism. Methods: In Study I, of the 24 children with ASD, 7 underwent surgical correction and 17 percutaneous occlusion of ASD. Study II had 33 patients with PDA undergoing percutaneous occlusion. In Study III, 28 patients with CoA underwent either surgical correction or percutaneous balloon dilatation of CoA. Study IV comprised 26 children with Mulibrey nanism. A total of 76 healthy voluntary children were examined as a control group. In each study, controls were matched to patients. All patients and controls underwent clinical cardiovascular examinations, two-dimensional (2D) and three-dimensional (3D) echocardiographic examinations, and blood sampling for measurement of natriuretic peptides prior to the intervention and twice or three times thereafter. Control children were examined once by 2D and 3D echocardiography. M-mode echocardiography was performed from the parasternal long axis view directed by 2D echocardiography. The left atrium-to-aorta (LA/Ao) ratio was calculated as an index of LA size. The end-diastolic and end-systolic dimensions of LV as well as the end-diastolic thicknesses of the interventricular septum and LV posterior wall were measured. LV volumes, and the fractional shortening (FS) and ejection fraction (EF) as indices of contractility were then calculated, and the z scores of LV dimensions determined. Diastolic function of LV was estimated from the mitral inflow signal obtained by Doppler echocardiography. In three-dimensional echocardiography, time-volume curves were used to determine end-diastolic and end-systolic volumes, stroke volume, and EF. Diastolic and systolic function of LV was estimated from the calculated first derivatives of these curves. Results: (I): In all children with ASD, during the one-year follow-up, the z score of the RV end-diastolic diameter decreased and that of LV increased. However, dilatation of RV did not resolve entirely during the follow-up in either treatment group. In addition, the size of LV increased more slowly in the surgical subgroup but reached control levels in both groups. Concentrations of natriuretic peptides in patients treated percutaneously increased during the first month after ASD closure and normalized thereafter, but in patients treated surgically, they remained higher than in controls. (II): In the PDA group, at baseline, the end-diastolic diameter of LV measured over 2SD in 5 of 33 patients. The median N-terminal pro-brain natriuretic peptide (proBNP) concentration before closure measured 72 ng/l in the control group and 141 ng/l in the PDA group (P = 0.001) and 6 months after closure measured 78.5 ng/l (P = NS). Patients differed from control subjects in indices of LV diastolic and systolic function at baseline, but by the end of follow-up, all these differences had disappeared. Even in the subgroup of patients with normal-sized LV at baseline, the LV end-diastolic volume decreased significantly during follow-up. (III): Before repair, the size and wall thickness of LV were higher in patients with CoA than in controls. Systolic blood pressure measured a median 123 mm Hg in patients before repair (P < 0.001) and 103 mm Hg one year thereafter, and 101 mm Hg in controls. The diameter of the coarctation segment measured a median 3.0 mm at baseline, and 7.9 at the 12-month (P = 0.006) follow-up. Thicknesses of the interventricular septum and posterior wall of the LV decreased after repair but increased to the initial level one year thereafter. The velocity time integrals of mitral inflow increased, but no changes were evident in LV dimensions or contractility. During follow-up, serum levels of natriuretic peptides decreased correlating with diastolic and systolic indices of LV function in 2D and 3D echocardiography. (IV): In 2D echocardiography, the interventricular septum and LV posterior wall were thicker, and velocity time integrals of mitral inflow shorter in patients with Mulibrey nanism than in controls. In 3D echocardiography, LV end-diastolic volume measured a median 51.9 (range 33.3 to 73.4) ml/m² in patients and 59.7 (range 37.6 to 87.6) ml/m² in controls (P = 0.040), and serum levels of ANPN and proBNP a median 0.54 (range 0.04 to 4.7) nmol/l and 289 (range 18 to 9170) ng/l, in patients and 0.28 (range 0.09 to 0.72) nmol/l (P < 0.001) and 54 (range 26 to 139) ng/l (P < 0.001) in controls. They correlated with several indices of diastolic LV function. Conclusions (I): During the one-year follow-up after the ASD closure, RV size decreased but did not normalize in all patients. The size of the LV normalized after ASD closure but the increase in LV size was slower in patients treated surgically than in those treated with the percutaneous technique. Serum levels of ANPN and proBNP were elevated prior to ASD closure but decreased thereafter to control levels in patients treated with the percutaneous technique but not in those treated surgically. (II): Changes in LV volume and function caused by PDA disappeared by 6 months after percutaneous closure. Even the children with normal-sized LV benefited from the procedure. (III): After repair of CoA, the RV size and the velocity time integrals of mitral inflow increased, and serum levels of natriuretic peptides decreased. Patients need close follow-up, despite cessation of LV pressure overload, since LV hypertrophy persisted even in normotensive patients with normal growth of the coarctation segment. (IV): In children with Mulibrey nanism, the LV wall was hypertrophied, with myocardial restriction and impairment of LV function. Significant correlations appeared between indices of LV function, size of the left atrium, and levels of natriuretic peptides, indicating that measurement of serum levels of natriuretic peptides can be used in the clinical follow-up of this patient group despite its dependence on loading conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Genetic manipulation to reverse molecular abnormalities associated with dysfunctional myocardium may provide novel treatment. This study aimed to determine the feasibility and functional consequences of in vivo beta-adrenergic receptor kinase (betaARK1) inhibition in a model of chronic left ventricular (LV) dysfunction after myocardial infarction (MI). METHODS AND RESULTS: Rabbits underwent ligation of the left circumflex (LCx) marginal artery and implantation of sonomicrometric crystals. Baseline cardiac physiology was studied 3 weeks after MI; 5x10(11) viral particles of adenovirus was percutaneously delivered through the LCx. Animals received transgenes encoding a peptide inhibitor of betaARK1 (Adeno-betaARKct) or an empty virus (EV) as control. One week after gene delivery, global LV and regional systolic function were measured again to assess gene treatment. Adeno-betaARKct delivery to the failing heart through the LCx resulted in chamber-specific expression of the betaARKct. Baseline in vivo LV systolic performance was improved in Adeno-betaARKct-treated animals compared with their individual pre-gene delivery values and compared with EV-treated rabbits. Total beta-AR density and betaARK1 levels were unchanged between treatment groups; however, beta-AR-stimulated adenylyl cyclase activity in the LV was significantly higher in Adeno-betaARKct-treated rabbits compared with EV-treated animals. CONCLUSIONS: In vivo delivery of Adeno-betaARKct is feasible in the infarcted/failing heart by coronary catheterization; expression of betaARKct results in marked reversal of ventricular dysfunction. Thus, inhibition of betaARK1 provides a novel treatment strategy for improving the cardiac performance of the post-MI heart.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

© 2015 Elsevier Inc. All rights reserved.Background 12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. Objective To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. Methods 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. Results The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Conclusions Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst the decision regarding defibrillator implantation in a patient with a familial sudden cardiac death syndrome is likely to be most significant for any particular individual, the clinical decision-making process itself is complex and requires interpretation and extrapolation of information from a number of different sources. This document provides recommendations for adult patients with the congenital Long QT syndromes, Brugada syndrome, catecholaminergic polymorphic ventricular tachycardia, hypertrophic cardiomyopathy, and arrhythmogenic right ventricular cardiomyopathy. Although these specific conditions differ in terms of clinical features and prognosis, it is possible and logical to take an approach to determining a threshold for implantable cardioveter-defibrillator implantation that is common to all of the familial sudden cardiac death syndromes based on estimates of absolute risk of sudden death. Published on behalf of the European Society of Cardiology. © The Author 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maternal diabetes mellitus is associated with increased teratogenesis, which can occur in pregestational type 1 and type 2 diabetes. Cardiac defects and with neural tube defects are the most common malformations observed in fetuses of pregestational diabetic mothers. The exact mechanism by which diabetes exerts its teratogenic effects and induces embryonic malformations is unclear. Whereas the sequelae of maternal pregestational diabetes, such as modulating insulin levels, altered fat levels, and increased reactive oxygen species, may play a role in fetal damage during diabetic pregnancy, hyperglycemia is thought to be the primary teratogen, causing particularly adverse effects on cardiovascular development. Fetal cardiac defects are associated with raised maternal glycosylated hemoglobin levels and are up to five times more likely in infants of mothers with pregestational diabetes compared with those without diabetes. The resulting anomalies are varied and include transposition of the great arteries, mitral and pulmonary atresia, double outlet of the right ventricle, tetralogy of Fallot, and fetal cardiomyopathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To determine whether 80-lead body surface potential mapping (BSPM) improves detection of acute coronary artery occlusion in patients presenting with out-of-hospital cardiac arrest (OHCA) due to ventricular fibrillation (VF) and who survived to reach hospital. Methods and results: Of 645 consecutive patients with OHCA who were attended by the mobile coronary care unit, VF was the initial rhythm in 168 patients. Eighty patients survived initial resuscitation, 59 of these having had BSPM and 12-lead ECG post-return of spontaneous circulation (ROSC) and in 35 patients (age 69±13 yrs; 60% male) coronary angiography performed within 24. h post-ROSC. Of these, 26 (74%) patients had an acutely occluded coronary artery (TIMI flow grade [TFG] 0/1) at angiography. Twelve-lead ECG criteria showed ST-segment elevation (STE) myocardial infarction (STEMI) using Minnesota 9-2 criteria - sensitivity 19%, specificity 100%; ST-segment depression (STD) =0.05. mV in =2 contiguous leads - sensitivity 23%, specificity 89%; and, combination of STEMI or STD criteria - sensitivity 46%, specificity 100%. BSPM STE occurred in 23 (66%) patients. For the diagnosis of TFG 0/1 in a main coronary artery, BSPM STE had sensitivity 88% and specificity 100% (c-statistic 0.94), with STE occurring most commonly in either the posterior, right ventricular or high right anterior territories. Conclusion: Among OHCA patients presenting with VF and who survived resuscitation to reach hospital, post-resuscitation BSPM STE identifies acute coronary occlusion with sensitivity 88% and specificity 100% (c-statistic 0.94). © 2012 Elsevier Ireland Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?

DESIGN: Animal study.

SETTING: University research laboratory.

SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.

INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).

MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).

CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiac myxomas are rare primary tumors with varied clinical presentations that may pose a diagnostic challenge. Here, we describe the case of a 21-year-old man with multiple cavitating lung lesions with aspergillosis and underlying right atrial myxoma, who presented with hemoptysis and weight loss. He was successfully treated with right atrial myxoma resection and antifungal agents, with no recurrence or complications after one year of follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’hypertension pulmonaire (HP) est une maladie dont l’étiologie est inconnue et qui entraîne ultimement une défaillance du ventricule droit (VD) et le décès. L’HP peut être induite chez le rat par la la monocrotaline (MCT), un alcaloïde pyrrolizidique extrait de la plante Crotalaria Spectabilis, causant des lésions à l’endothélium des artères pulmonaires, menant à un épaississement de ces dernières et à une augmentation de la résistance vasculaire. Ceci à pour conséquence de causer une hypertrophie du VD, de l’inflammation, une dysfonction endothéliale NO-dépendante des artères coronariennes et une augmentation des peptides natriurétiques circulants. Objectif: Nous avons testé l’hypothèse selon laquelle l’étiopathologie de l’HP impliquerait le récepteur à ocytocine (OTR) dû à son implication fonctionnelle avec les cytokines inflammatoires et la libération du peptide natriurétique atrial (ANP) et du NO. Méthodes: Des rats mâles Sprague-Dawley pesant 220-250g reçurent une seule injection sous-cutanée de MCT (60 mg/kg). 6 à 7 semaines (46±1 jours) suivant l’injection, les rats furent sacrifiés et l’expression génique et protéique fut déterminée par PCR en temps réel et par western blot, respectivement, dans le VD et le ventricule gauche (VG) Résultats: Les rats traités au MCT démontrèrent une augmentation significative du VD. Une hypertrophie du VD était évidente puisque le ratio du VD sur le VG ainsi que le poids du septum étaient près de 77% plus élevés chez les rats traités au MCT que chez les rats contrôles. Le traitement au MCT augmenta l’expression génique d’ANP (3.7-fois dans le VG et 8-fois dans le VD) ainisi que le NP du cerveau (2.7-fois dans le VG et 10-fois dans le VD). Les transcrits de trois récepteurs de NP augmentèrent significativement (0.3-2 fois) seulement dans le VD. L’expression protéique de la NO synthase (iNOS) fut également augmentée de façon sélective dans le VD. Par contre, les transcripts de NOS endothéliale et de NOS neuronale étaient plus élevés (0.5-2 fold) dans le VG. L’ARNm et l’expression protéique d’OTR furent diminués de 50% dans le VD, tandis qu’une augmentation de l’expression des cytokines IL-1β and IL-6 fut observée. L’ARNm de Nab1, un marqueur d’hypertrophie pathologique, fut augmentée de deux-fois dans le VD. Conclusion: L’augmentation d’expression génique de NP dans le VD des rats traités au MCT est associée à une augmentation des transcripts du récepteur NP, suggérant une action locale de NP dans le VD durant l’HP. L’expression d’OTR est atténuée dans le VD, possiblement par des cytokines inflammatoires puisque le promoteur du gène de l’OTR contient de multiples éléments de réponse aux interleukines. Diminuer l’expression d’OTR dans le VD durant l’hypertension pulmonaire pourrait influencer de manière positive la fonction cardiaque car l’OTR régule la contractilité et le rythme cardiaque. Mots clés: hypertension pulmonaire, hypertrophie du ventricule droit monocrotaline, récepteur à ocytocine, inflammation, peptides natriurétiques.