815 resultados para Research through Design


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The highway departments of all fifty states were contacted to find the extent of application of integral abutment bridges, to survey the different guidelines used for analysis and design of integral abutment bridges, and to assess the performance of such bridges through the years. The variation in design assumptions and length limitations among the various states in their approach to the use of integral abutments is discussed. The problems associated with lateral displacements at the abutment, and the solutions developed by the different states for most of the ill effects of abutment movements are summarized in the report. An algorithm based on a state-of-the-art nonlinear finite element procedure was developed and used to study piling stresses and pile-soil interaction in integral abutment bridges. The finite element idealization consists of beam-column elements with geometric and material nonlinearities for the pile and nonlinear springs for the soil. An idealized soil model (modified Ramberg-Osgood model) was introduced in this investigation to obtain the tangent stiffness of the nonlinear spring elements. Several numerical examples are presented in order to establish the reliability of the finite element model and the computer software developed. Three problems with analytical solutions were first solved and compared with theoretical solutions. A 40 ft H pile (HP 10 X 42) in six typical Iowa soils was then analyzed by first applying a horizontal displacement (to simulate bridge motion) and no rotation at the top and then applying a vertical load V incrementally until failure occurred. Based on the numerical results, the failure mechanisms were generalized to be of two types: (a) lateral type failure and (b) vertical type failure. It appears that most piles in Iowa soils (sand, soft clay and stiff clay) failed when the applied vertical load reached the ultimate soil frictional resistance (vertical type failure). In very stiff clays, however, the lateral type failure occurs before vertical type failure because the soil is sufficiently stiff to force a plastic hinge to form in the pile as the specified lateral displacement is applied. Preliminary results from this investigation showed that the vertical load-carrying capacity of H piles is not significantly affected by lateral displacements of 2 inches in soft clay, stiff clay, loose sand, medium sand and dense sand. However, in very stiff clay (average blow count of 50 from standard penetration tests), it was found that the vertical load carrying capacity of the H pile is reduced by about 50 percent for 2 inches of lateral displacement and by about 20 percent for lateral displacement of 1 inch. On the basis of the preliminary results of this investigation, the 265-feet length limitation in Iowa for integral abutment concrete bridges appears to be very conservative.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Two objectives were involved in this recycling project: To determine if the asphalt concrete surfacing from an existing roadway could be removed, the existing portland cement concrete pavement broken, removed, crushed to 1-1/2 inch minus, proportioned through a conventional central mix proportioning plant with the addition of concrete sand, and placed with a conventional slipform paver; and to determine if a two course, composite pavement, each course of different mix proportions, could be placed monolithically with conventional slipform equipment after being proportioned and mixed in a conventional central mix plant. The project was completed with no major problem. The objectives were satisfactorily met. The project was a success to the degree that the Iowa D.O.T. is proceeding with at least two projects for the 1977 construction season that will utilize the old pavement as appregate for the new pavement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Since 1987, the Iowa Department of Transportation has based control of hot asphalt concrete mixes on cold feed gradations. This report presents results of comparisons between cold feed gradations and gradations of aggregate from the same material after it has been processed through the plant and laydown machine. Results are categorized based on mix type, plant type, and method of dust control, in an effort to quantify and identify the factors contributing to those changes. Results of the report are: 1. From the 390 sample comparisons made, aggregate degradation due to asphalt plant processing was demonstrated by an average increase of +0.7% passing the #200 sieve and an average increase in surface area of +1.8 sq. ft. per pound of aggregate. 2. Categories with Type A Mix or Recycling as a sorting criteria generally produced greater degradation than categories containing Type B Mixes and/or plants with scrubbers. 3. None of the averages calculated for the categories should be considered unacceptably high, however, it is information that should be considered when making mix changes in the field, selecting asphalt contents for borderline mix designs, or when evaluating potential mix gradation specification or design criteria changes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Quality granular materials suitable for building all-weather roads are not uniformly distributed throughout the state of Iowa. For this reason the Iowa Highway Research Board has sponsored a number of research programs for the purpose of developing new and effective methods for making use of whatever materials are locally available. This need is ever more pressing today due to the decreasing availability of road funds and quality materials, and the increasing costs of energy and all types of binder materials. In the 1950s, Professor L. H. Csanyi of Iowa State University had demonstrated both in the laboratory and in the field, in Iowa and in a number of foreign countries, the effectiveness of preparing low cost mixes by stabilizing ungraded local aggregates such as gravel, sand and loess with asphalt cements using the foamed asphalt process. In this process controlled foam was produced by introducing saturated steam at about 40 psi into heated asphalt cement at about 25 psi through a specially designed and properly adjusted nozzle. The reduced viscosity and the increased volume and surface energy in the foamed asphalt allowed intimate coating and mixing of cold, wet aggregates or soils. Through the use of asphalt cements in a foamed state, materials normally considered unsuitable could be used in the preparation of mixes for stabilized bases and surfaces for low traffic road construction. By attaching the desired number of foam nozzles, the foamed asphalt can be used in conjunction with any type of mixing plant, either stationary or mobile, batch or continuous, central plant or in-place soil stabilization.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An Iowa D.O.T. Laboratory built machine was constructed for the chloride permeability testing of concrete by measuring electric current through a specimen between a salt solution and a base solution. This study had two purposes. The first was to evaluate the machine's performance. To do this, three concrete mixes were made consisting of different cement factors and water/cement ratios. Each mix was tested for chloride ion content by the 90- day salt ponding method and for chloride permeability at a 28-day cure by the permeability machine. The results from each test were evaluated to see if there was correlation between chloride ion content and the chloride permeability. It was determined that there was a correlation and that the permeability machine was satisfactory for determining chloride permeability in concrete. The second purpose of this study was to examine the effects that pozzolans have on the chloride permeability of concrete. Four mixes were made: one without any pozzolans as a control, one with class C fly ash, one with class F fly ash, and one with silica fume. Specimens from each mix were evaluated for chloride ion content by the 90-day salt ponding test and by the laboratory built machine for chloride permeability after curing 28 days. Specimens from these mixes were also taken from the salt ponding slabs after completion of the ponding test to examine the effect chloride ion content has on the operation of the chloride permeability machine. Specimens containing pozzolans were also examined for chloride permeability after a cure of 180 days. It was determined that the addition of pozzolans to concrete lowers the chloride permeability as measured by the permeability machine. Class F fly ash and silica fume in the concrete had a major effect in lowering the chloride permeability in concrete as measured by the permeability machine.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The AASHTO strategic plan in 2005 for bridge engineering identified extending the service life of bridges and accelerating bridge construction as two of the grand challenges in bridge engineering. These challenges have the objective of producing safer and more economical bridges at a faster rate with a minimum service life of 75 years and reduced maintenance cost to serve the country’s infrastructure needs. Previous studies have shown that a prefabricated full-depth precast concrete deck system is an innovative technique that accelerates the rehabilitation process of a bridge deck, extending its service life with reduced user delays and community disruptions and lowering its life-cycle costs. Previous use of ultra-high performance concrete (UHPC) for bridge applications in the United States has been considered to be efficient and economical because of its superior structural characteristics and durability properties. Full-depth UHPC waffle deck panel systems have been developed over the past three years in Europe and the United States. Subsequently, a single span, 60-ft long and 33-ft wide prototype bridge with full-depth prefabricated UHPC waffle deck panels has been designed and built for a replacement bridge in Wapello County, Iowa. The structural performance characteristics and the constructability of the UHPC waffle deck system and its critical connections were studied through an experimental program at the structural laboratory of Iowa State University (ISU). Two prefabricated full-depth UHPC waffle deck (8 feet by 9 feet 9 inches by 8 inches) panels were connected to 24-ft long precast girders, and the system was tested under service, fatigue, overload, and ultimate loads. Three months after the completion of the bridge with waffle deck system, it was load tested under live loads in February 2012. The measured strain and deflection values were within the acceptable limits, validating the structural performance of the bridge deck. Based on the laboratory test results, observations, field testing of the prototype bridge, and experience gained from the sequence of construction events such as panel fabrication and casting of transverse and longitudinal joints, a prefabricated UHPC waffle deck system is found to be a viable option to achieve the goals of the AASHTO strategic plan.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: This paper aimed to use the Delphi technique to develop a consensus framework for a multinational, workplace walking intervention. Methods: Ideas were gathered and ranked from eight recognized and emerging experts in the fields of physical activity and health, from universities in Australia, Canada, England, the Netherlands, Northern Ireland, and Spain. Members of the panel were asked to consider the key characteristics of a successful campus walking intervention. Consensus was reached by an inductive, content analytic approach, conducted through an anonymous, three-round, e-mail process. Results: The resulting framework consisted of three interlinking themes defined as “design, implementation, and evaluation.” Top-ranked subitems in these themes included the need to generate research capacity (design), to respond to group needs through different walking approaches (implementation), and to undertake physical activity assessment (evaluation). Themes were set within an underpinning domain, referred to as the “institution” and sites are currently engaging with subitems in this domain, to provide sustainable interventions that reflect the practicalities of local contexts and needs. Conclusions: Findings provide a unique framework for designing, implementing, and evaluating walking projects in universities and highlight the value of adopting the Delphi technique for planning international, multisite health initiatives.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Among the variety of road users and vehicle types that travel on U.S. public roadways, slow moving vehicles (SMVs) present unique safety and operations issues. SMVs include vehicles that do not maintain a constant speed of 25 mph, such as large farm equipment, construction vehicles, or horse-drawn buggies. Though the number of crashes involving SMVs is relatively small, SMV crashes tend to be severe. Additionally, SMVs can be encountered regularly on non-Interstate/non-expressway public roadways, but motorists may not be accustomed to these vehicles. This project was designed to improve transportation safety for SMVs on Iowa’s public roadway system. This report includes a literature review that shows various SMV statistics and laws across the United States, a crash study based on three years of Iowa SMV crash data, and recommendations from the SMV community.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In April 2008 a preliminary investigation of fatal and major injury crashes on Iowa’s primary road system from 2001 through 2007 was conducted by the Iowa Department of Transportation, Office of Traffic and Safety. A mapping of these data revealed an apparent concentration of these serious crashes on a section of Iowa 25 north of Creston. Based on this information, a road safety audit of this roadway section was requested by the Office of Traffic and Safety. Iowa 25 is a two-lane asphaltic concrete pavement roadway, 22 ft in width with approximately 6 ft wide granular shoulders. Originally constructed in 1939, the roadway was last rehabilitated in 1996 with a 4-in. asphalt overlay. Except for shoulder paving through a curve area, no additional work beyond routine maintenance has been accomplished in the section. The 2004 traffic map indicates that IA 25 has a traffic volume of approximately 2070 vehicles per day with 160 commercial vehicles. The posted speed is 55 mph. This report contains a discussion of audit team findings, crash and roadway data, and recommendations for possible mitigation of safety concerns for this roadway section.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Iowa Department of Transportation used a high molecular weight methacrylate (HMWM) resin to seal a 3,340 ft. x 64 ft. bridge deck in October 1986. The sealing was necessary to prevent deicing salt brine from entering a substantial number of transverse cracks that coincided with the epoxy coated top steel and unprotected bottom steel. HMWM resin is a three component product composed of a monomer, a curnene hydroperoxide initiator and a cobalt naphthenate promoter. The HMWM was applied with a dual spray bar system and flat-fan nozzles. Initiated monomer delivered through one spray bar was mixed in the air with promoted monomer from the other spray bar. The application rate averaged 0.956 gallons per 100 square feet for the tined textured driving lanes. Dry sand was broadcast on the surface at an average coverage of 0.58 lbs. per square yard to maintain friction. Coring showed that the H.MWM resin penetrated the cracks more than two inches deep. Testing of the treated deck yielded Friction Numbers averaging 33 with a treaded tire compared to 36 prior to treatment. An inspection soon after treatment found five leaky cracks in one of the 15 spans. One inspection during a steady rain showed no leakage, but leakage from numerous cracks occurred during a subsequent rain. A second HMWM application was made on two spans to determine if a double application would prevent leakage. This evaluation has not been completed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A contract for Project HR-20 "Treating Loess, Fine Sands and Soft Limestones with Liquid Binders" of the Iowa Highway Research Board was awarded in December, 1951, to the Iowa Engineering Experiment Station of Iowa State University as its Project 295-S. By 1954 the studies of the fine materials and asphalts had progressed quite well, and a method of treating the fine materials, called the atomization process, had been applied. A study was begun in 1954 to see if some of the problems of the atomization process could be solved with the use of foamed asphalt. Foamed asphalt has several advantages. The foaming of asphalt increases its volume, reduces its viscosity, and alters its surface tension so that it will adhere tenaciously to solids. Foamed asphalt displaces moisture from the surface of a solid and coats it with a thin film. Foamed asphalt can permeate deeply into damp soils. In the past these unusual characteristics were considered nuisances to be avoided if possible.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Two lanes of a major four lane arterial street needed to be reconstructed in Cedar Rapids, Iowa. The traffic volumes and difficulty of detouring the traffic necessitated closure for construction be held to an absolute minimum. Closure of the intersections, even for one day, was not politically feasible. Therefore, Fast Track and Fast Track II was specified for the project. Fast Track concrete paving has been used successfully in Iowa since 1986. The mainline portion of the project was specified to be Fast Track and achieved the opening strength of 400 psi in less than twelve hours. The intersections were allowed to be closed between 6 PM and 6 AM. This could occur twice - once to remove the old pavement and place the base and temporary surface and the second time to pave and cure the new concrete. The contractor was able to meet these restrictions. The Fast Track II used in the intersections achieved the opening strength of 350 psi in six to seven hours. Two test sections were selected in the mainline Fast Track and two intersections were chosen to test the Fast Tract II. Both flexural and compression specimens were tested. Pulse velocity tests were conducted on the pavement and test specimens. Maturity curves were developed through monitoring of the temperatures. Correlations were performed between the maturity and pulse velocity and the flexural strengths. The project was successful in establishing the feasibility of construction at night, with no disruption of traffic in the daytime, using fast Track II. Both the Fast Track II pavements were performing well four years after construction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Työn tavoitteena oli kehittää teräspalkkirakenteiden palosuunnittelua ja palosuojauksen toteutusta öljynjalostamolla käytettävien kantavien teräspalkkirakenteiden osalta. Lisäksi tavoitteena oli luoda suunnitteluohjeen runko palomitoituksen toteuttamiseksi Neste Engineering Oy:ssä. Ongelmakohtia työssä olivat rakenteiden kapasiteettien tarkka määritys, toimivien toteutusratkaisujen etsiminen, sekä öljynjalostamolla mitoituspalona käytettävän hiilivetypalon SFS-ENV-1992-1-2 käyttö yleisemmin mitoituspalona käytettävän standardipalo ISO-834 sijaan. Työssä perehdyttiin kirjallisuuden perusteella eri palosuojausmenetelmiin. Tarkemman jatkotutkimuksen kohteeksi otettiin jo käytössä hyväksi havaittu teräsputkipalkkien sisäpuoleinen betonitäyttö. Menetelmässä teräsputkipalkin oletetaan kantavan kuormat normaalitilassa ja sisällä olevan raudoitetun betonin palossa. Palkkirakenteiden kapasiteettimitoitus määritettiin laskennallisesti poikkileikkauksille. Mitoitus perustuu palkissa tapahtuvien sisäisten venymien ja puristumien tarkasteluun, sekä poikkileikkauksen tarkan lämpötilajakauman huomioimiseen. Raudoitustankojen ankkurointia palkki-pilari-liitoksessa kehitettiin valmistuksen kannalta yksioikoisemmaksi ja helpommin toteutettavaksi. Palkkien raudoituksiin suunniteltiin kierremuhvijatkoksella toteutettava ankkurointimenetelmä, jolla palkkien raudoitustangot saadaan ankkuroitua täydestä kapasiteetistaan tapauskohtaisesti pilarin vastakkaisella puolella olevaan palkkiin tai ankkurointikappaleella pilariin. Teräsputkipilarin betonivalun vaihtoehtoisiin menetelmiin tutustuttiin. Pilarin alapäähän asennettavan venttiilin läpi tapahtuva täyttö helpottaa betonointityövaihetta. Tutkimuksen tuloksena luotiin suunnitteluohjeen runko, jonka pohjalta voidaan tehdä lopullinen ohje. Myös työn tuloksena saatu laskentaohjelma palkkien momentti-kapasiteetin ja pilarin nurjahduskuorman laskemiseksi helpottaa suunnittelua. Raudoituksen ankkurointiin ja betonointiin esitettyjen menetelmien toimivuus on syytä kokeilla käytännössä ja tehdä jatkokehitys näistä saatavien kokemusten pohjalta.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tourism is one of the biggest industry branches with billions of tourists traveling every year around the world. Therefore, solutions providing tourist information have to be up to date with both changes in the industry and the world’s technological progress. The aim of this thesis is to present a design and a prototype of a tourist mobile service which is individual-oriented, cost-free for the end user, and secure. On the information providers’ side, the solution is implemented as a Webbased database. The end users access the information through a Bluetooth application on their mobile devices. The Bluetooth-based solution allows to avoid any costs for the end users, that is tourists. The study shows that, even with small data transfers, the tourists could save significantly when compared to possible roaming charges for data transfer. Also, the proposed mobile service is not intrusive, as it is provided through an application installed by tourists voluntarily on their mobile devices. Through design and implementation this work shows that it is possible to build a system which can be used to provide information services to tourists through mobile phones. The work achieved a successful ongoing synchronization between the client and the server databases. Implementation and usage were limited to smart phones only, as they provide better technological support for the solution having features like maps, GPS, Wi-Fi, Bluetooth and Databases. Moreover, the design of this system shows how Bluetooth technology can be used effectively as a means of communication while minimizing its shortcomings and risks, such as security, by bypassing Bluetooth server service discovery protocol (SDP) and connecting directly to the device. Apart from showing the design and implementation of the end-user costfree mobile information service, the results of this work also highlight the possible business opportunities to the provider of the service.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ce mémoire s’inscrit dans le domaine de l’architecture du paysage et du design urbain. La recherche se construit autour d’un questionnement sur le sens pouvant être attribué au parc La Fontaine par ses usagers en tant que cadre de vie urbain montréalais. Ce parc est un lieu emblématique de la ville par le caractère historique de son aménagement. Il est aussi un lieu populaire par sa situation géographique centrale au sein de l’arrondissement du Plateau-Mont-Royal. Par l’analyse de ce parc, nous cherchons à porter un regard sur la manière dont se construit l’expérience d’un parc urbain dans les particularités de son aménagement, de son contexte social et culturel. Notre étude semble pertinente dans la mesure où cet espace n’a jamais été abordé selon l’analyse de l’expérience paysagère. Notre réflexion se construit à partir d’un modèle socioculturel soutenu par une revue de littérature en architecture de paysage. Les travaux menés à la Chaire en paysage et environnement de l’Université de Montréal ont particulièrement été sollicités. Ce modèle considère le paysage comme une qualification sociale et culturelle d’un territoire. Il engage l’analyse vers des perspectives pluridimensionnelle, expérientielle et polysensorielle, tout en considérant le caractère formel (attributs physiques) du paysage. Nous avons également joint à ce cadre théorique les recherches menées en design et en anthropologie des sens. Ces axes de recherche éclairent les notions de l’expérience esthétique et sensorielle particulièrement en regard de la compréhension du vécu d’un espace ordinaire et quotidien. Selon ce cadre conceptuel, notre recherche fait appel à une approche compréhensive. Ainsi, nous abordons l’expérience du parc par un modèle d’analyse mettant l’emphase sur les usages, l’interprétation et la représentation de l’aménagement du parc La Fontaine. La méthodologie s’appuie sur une démarche de recherche qualitative. Elle se fonde sur une observation non participante des usagers du parc, sur des entretiens semi-dirigés et sur une étude physico-spatiale du lieu. Ce mémoire a pour finalité de conduire une première lecture du parc La Fontaine en abordant les dimensions composant le vécu de ses usagers. Nous espérons pouvoir contribuer à notre échelle à l’avancée des connaissances de cet espace du point de vue expérientiel et de la perspective paysagère sur la compréhension des parcs urbains.