994 resultados para Refuge Floor Design


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Manufacturing firms are driven by competitive pressures to continually improve the effectiveness and efficiency of their organisations. For this reason, manufacturing engineers often implement changes to existing processes, or design new production facilities, with the expectation of making further gains in manufacturing system performance. This thesis relates to how the likely outcome of this type of decision should be predicted prior to its implementation. The thesis argues that since manufacturing systems must also interact with many other parts of an organisation, the expected performance improvements can often be significantly hampered by constraints that arise elsewhere in the business. As a result, decision-makers should attempt to predict just how well a proposed design will perform when these other factors, or 'support departments', are taken into consideration. However, the thesis also demonstrates that, in practice, where quantitative analysis is used to evaluate design decisions, the analysis model invariably ignores the potential impact of support functions on a system's overall performance. A more comprehensive modelling approach is therefore required. A study of how various business functions interact establishes that to properly represent the kind of delays that give rise to support department constraints, a model should actually portray the dynamic and stochastic behaviour of entities in both the manufacturing and non-manufacturing aspects of a business. This implies that computer simulation be used to model design decisions but current simulation software does not provide a sufficient range of functionality to enable the behaviour of all of these entities to be represented in this way. The main objective of the research has therefore been the development of a new simulator that will overcome limitations of existing software and so enable decision-makers to conduct a more holistic evaluation of design decisions. It is argued that the application of object-oriented techniques offers a potentially better way of fulfilling both the functional and ease-of-use issues relating to development of the new simulator. An object-oriented analysis and design of the system, called WBS/Office, are therefore presented that extends to modelling a firm's administrative and other support activities in the context of the manufacturing system design process. A particularly novel feature of the design is the ability for decision-makers to model how a firm's specific information and document processing requirements might hamper shop-floor performance. The simulator is primarily intended for modelling make-to-order batch manufacturing systems and the thesis presents example models created using a working version of WBS/Office that demonstrate the feasibility of using the system to analyse manufacturing system designs in this way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We show that by proper code design, phase noise induced cycle slips causing an error floor can be mitigated for 28 Gbaud DQPSK systems. Performance of BCH codes are investigated in terms of required overhead. © 2014 OSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this thesis was to identify the optimal design parameters for a jet nozzle which obtains a local maximum shear stress while maximizing the average shear stress on the floor of a fluid filled system. This research examined how geometric parameters of a jet nozzle, such as the nozzle's angle, height, and orifice, influence the shear stress created on the bottom surface of a tank. Simulations were run using a Computational Fluid Dynamics (CFD) software package to determine shear stress values for a parameterized geometric domain including the jet nozzle. A response surface was created based on the shear stress values obtained from 112 simulated designs. A multi-objective optimization software utilized the response surface to generate designs with the best combination of parameters to achieve maximum shear stress and maximum average shear stress. The optimal configuration of parameters achieved larger shear stress values over a commercially available design.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Purpose. Electrical stimulation of the pelvic floor is used as an adjunct in the conservative treatment of urinary incontinence. No consensus exists, however, regarding electrode placements for optimal stimulation of the pelvic-floor musculature. The purpose of this study was to compare two different bipolar electrode placements, one suggested by Laycock and Green (L2) the other by Dumoulin (D2), during electrical stimulation with interferential currents of the pelvic-floor musculature in continent women, using a two-group crossover design. Subjects. Ten continent female volunteers, ranging in age from 20 to 39 years (X̅=27.3, SD=5.6), were randomly assigned to one of two study groups. Methods. Each study group received neuromuscular electrical stimulation (NMES) of the pelvic-floor musculature using both electrode placements, the order of application being reversed for each group. Force of contraction was measured as pressure (in centimeters of water [cm H2O]) exerted on a vaginal pressure probe attached to a manometer. Data were analyzed using a two-way, mixed-model analysis of variance. Results. No difference in pressure was observed between the two electrode placements. Differences in current amplitude were observed, with the D2 electrode placement requiring less current amplitude to produce a maximum recorded pressure on the manometer. Subjective assessment by the subjects revealed a preference for the D2 electrode placement (7 of 10 subjects). Conclusion and Discussion. The lower current amplitudes required with the D2 placement to obtain recordings comparable to those obtained with the L2 technique suggest a more comfortable stimulation of the pelvic-floor muscles. The lower current amplitudes required also suggest that greater increases in pressure might be obtained with the D2 placement by increasing the current amplitude while remaining within the comfort threshold. These results will help to define treatment guidelines for a planned clinical study investigating the effects of NMES and exercise in the treatment of urinary stress incontinence in women postpartum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Purpose. Electrical stimulation of the pelvic floor is used as an adjunct in the conservative treatment of urinary incontinence. No consensus exists, however, regarding electrode placements for optimal stimulation of the pelvic-floor musculature. The purpose of this study was to compare two different bipolar electrode placements, one suggested by Laycock and Green (L2) the other by Dumoulin (D2), during electrical stimulation with interferential currents of the pelvic-floor musculature in continent women, using a two-group crossover design. Subjects. Ten continent female volunteers, ranging in age from 20 to 39 years (X̅=27.3, SD=5.6), were randomly assigned to one of two study groups. Methods. Each study group received neuromuscular electrical stimulation (NMES) of the pelvic-floor musculature using both electrode placements, the order of application being reversed for each group. Force of contraction was measured as pressure (in centimeters of water [cm H2O]) exerted on a vaginal pressure probe attached to a manometer. Data were analyzed using a two-way, mixed-model analysis of variance. Results. No difference in pressure was observed between the two electrode placements. Differences in current amplitude were observed, with the D2 electrode placement requiring less current amplitude to produce a maximum recorded pressure on the manometer. Subjective assessment by the subjects revealed a preference for the D2 electrode placement (7 of 10 subjects). Conclusion and Discussion. The lower current amplitudes required with the D2 placement to obtain recordings comparable to those obtained with the L2 technique suggest a more comfortable stimulation of the pelvic-floor muscles. The lower current amplitudes required also suggest that greater increases in pressure might be obtained with the D2 placement by increasing the current amplitude while remaining within the comfort threshold. These results will help to define treatment guidelines for a planned clinical study investigating the effects of NMES and exercise in the treatment of urinary stress incontinence in women postpartum.