975 resultados para Rectangular Pressure Pulse


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study examined the relationships among ethnicity/race, lifestyle factors, phylloquinone (vitamin K₁) intake, and arterial pulse pressure in a nationally representative sample of older adults from four ethnic/racial groups: non-Hispanic Whites, non-Hispanic Blacks, Mexican Americans, and other Hispanics. This was a cross-sectional study of U.S. representative sample with data from the National Health and Nutrition Examination Surveys, 2007-2008 and 2009-2010 of adults aged 50 years and older (N = 5296). Vitamin K intake was determined by 24-hour recall. Pulse pressure was calculated as the difference between the averages of systolic blood pressure and diastolic blood pressure. Compared to White non-Hispanics, the other ethnic/racial groups were more likely to have inadequate vitamin K₁ intake. Inadequate vitamin K₁ intake was an independent predictor of high arterial pulse pressure. This was the first study that compared vitamin K₁ inadequacy with arterial pulse pressure across ethnicities/races in U.S. older adults. These findings suggest that vitamin K screening may be a beneficial marker for the health of older adults.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High blood pressure (BP), pulse pressure (PP), and rate pressure product (RPP) areeach associated independently with a poor outcome in acute ischemic stroke. Whereas nitric oxide (NO) donors, such as glyceryl trinitrate (GTN), lower blood pressure in acute ischemic stroke, their effect on other hemodynamic measures is not known. We performed a systematic review of the effects of NO donors on systemic hemodynamic measures in patients with acute/subacute stroke. Randomized controlled trials were identified from searches of the Cochrane Library, Pubmed, and Embase. Information on hemodynamic measures, including systolic BP (SBP), diastolic BP (DBP), and heart rate, were assessed, and hemodynamic derivatives of these were calculated: PP (PP SBP DBP), mean arterial pressure (MAP DBP PP/3), mid blood pressure (MBP (SBP DBP)/2), pulse pressure index (PPI PP/MAP), and RPP (RPP SBP HR). The effect of treatment on hemodynamic measures was calculated as the weighted mean difference (WMD) between treated and control groups with adjustment for baseline. Results: Three trials involving 145 patients were identified; 93 patients received the NO donor, GTN, and 52 control. As compared with placebo, GTN significantly reduced SBP (WMD -9.80 mmHg, p< 0.001), DBP (WMD -4.43 mmHg, p<0.001), MAP (WMD -6.41 mmHg, p< 0.001), MBP (WMD -7.33 mmHg,p<0.001), PP (WMD -6.11 mmHg, p<0.001 ) and PPI (WMD -0.03, p=0.04 ). 3 GTN increased HR (WMD +3.87 bpm, p<0.001) and non-significantly lowered RPP (WMD -323 mmHg.bpm, p=0.14). Conclusion: The NO donor GTN reduces BP, PP and other derivatives in acute and subacute stroke whilst increasing heart rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of sample geometry on the melting rates of burning iron rods was assessed. Promoted-ignition tests were conducted with rods having cylindrical, rectangular, and triangular cross-sectional shapes over a range of cross-sectional areas. The regression rate of the melting interface (RRMI) was assessed using a statistical approach which enabled the quantification of confidence levels for the observed differences in RRMI. Statistically significant differences in RRMI were observed for rods with the same cross-sectional area but different cross-sectional shape. The magnitude of the proportional difference in RRMI increased with the cross-sectional area. Triangular rods had the highest RRMI, followed by rectangular rods, and then cylindrical rods. The dependence of RRMI on rod shape is shown to relate to the action of molten metal at corners. The corners of the rectangular and triangular rods melted faster than the faces due to their locally higher surface area to volume ratios. This phenomenon altered the attachment geometry between liquid and solid phases, increasing the surface area available for heat transfer, causing faster melting. Findings relating to the application of standard flammability test results in industrial situations are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atmospheric-pressure plasma processing techniques emerge as efficient and convenient tools to engineer a variety of nanomaterials for advanced applications in nanoscience and nanotechnology. This work presents different methods, including using a quasi-sinusoidal high-voltage generator, a radio-frequency power supply, and a uni-polar pulse generator, to generate atmospheric-pressure plasmas in the jet or dielectric barrier discharge configurations. The applicability of the atmospheric-pressure plasma is exemplified by the surface modification of nanoparticles for polymeric nanocomposites. Dielectric measurements reveal that representative nanocomposites with plasma modified nanoparticles exhibit notably higher dielectric breakdown strength and a significantly extended lifetime.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transmission loss of a rectangular expansion chamber, the inlet and outlet of which are situated at arbitrary locations of the chamber, i.e., the side wall or the face of the chamber, are analyzed here based on the Green's function of a rectangular cavity with homogeneous boundary conditions. The rectangular chamber Green's function is expressed in terms of a finite number of rigid rectangular cavity mode shapes. The inlet and outlet ports are modeled as uniform velocity pistons. If the size of the piston is small compared to wavelength, then the plane wave excitation is a valid assumption. The velocity potential inside the chamber is expressed by superimposing the velocity potentials of two different configurations. The first configuration is a piston source at the inlet port and a rigid termination at the outlet, and the second one is a piston at the outlet with a rigid termination at the inlet. Pressure inside the chamber is derived from velocity potentials using linear momentum equation. The average pressure acting on the pistons at the inlet and outlet locations is estimated by integrating the acoustic pressure over the piston area in the two constituent configurations. The transfer matrix is derived from the average pressure values and thence the transmission loss is calculated. The results are verified against those in the literature where use has been made of modal expansions and also numerical models (FEM fluid). The transfer matrix formulation for yielding wall rectangular chambers has been derived incorporating the structural–acoustic coupling. Parametric studies are conducted for different inlet and outlet configurations, and the various phenomena occurring in the TL curves that cannot be explained by the classical plane wave theory, are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the effects of Lactobacillus helveticus fermented milk (peptide milk) containing the casein-derived tripeptides Isoleucyl-prolyl-proline (Ile-Pro-Pro) and Valyl-prolyl-proline (Val-Pro-Pro) on blood pressure and vascular function in hypertensive subjects. The peptide milk lowered systolic and diastolic blood pressure in long-term use in hypertensive subjects when blood pressure was measured by using 24-hour ambulatory blood pressure measurement (ABPM). The blood pressure lowering effect was seen with the dose of 50 mg of tripeptides, and a tendency for lowering blood pressure was also observed when the dose was 5 mg. No adverse effects compared to the placebo group were reported or detected in laboratory analysis. The effect of the peptide milk on arterial stiffness was shown using two different methods, the ambulatory arterial stiffness index (AASI) and pulse wave analysis (PWA). According to the AASI, arterial stiffness was significantly reduced in the peptide milk group compared to the baseline level, but the difference was not significant compared to the placebo group. PWA showed that the peptide milk reduced arterial stiffness significantly compared to the placebo group. Endothelium-independent relaxation (nitroglycerin) and endothelium-dependent relaxation (salbutamol) did not differ between the groups. The blood pressure lowering mechanisms of the tripeptides and the kinetics of Ile-Pro-Pro were investigated using spontaneously hypertensive rats (SHR) and Sprague-Dawley rats. Previous studies have suggested that the blood pressure lowering effect of the tripeptides Ile-Pro-Pro and Val-Pro-Pro is based on angiotensin-converting enzyme inhibition, but the present findings did not agree with these previous studies. It was shown in SHR that calcium, potassium and magnesium may also have an important role in attenuating the development of hypertension as part of the peptide milk effect. In addition, the present study suggests indirectly that improved endothelial nitric oxide release capacity is not the mechanism by which peptide milk mediates its favourable circulatory effects. The kinetics of Ile-Pro-Pro were studied using adult Sprague-Dawley rats. The results showed that orally administered Ile-Pro-Pro is absorbed at least partly intact from the gastrointestinal tract. Radiolabelled Ile-Pro-Pro was distributed in different tissues and considerable radioactivity levels were found in tissues related to the renin-angiotensin system (RAS), adrenals, aorta and kidneys. Ile-Pro-Pro does not bind to plasma proteins, and therefore it is possible that its blood pressure lowering effect is mediated by free Ile-Pro-Pro. In conclusion, consumption of the peptide milk lowers blood pressure and reduces arterial stiffness in hypertensive subjects. Ile-Pro-Pro can be absorbed partly intact from the gastrointestinal tract and might accumulate in tissues related to the RAS. The precise blood pressure lowering mechanism of peptide milk remains to be studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current voltage characteristics ofo-tolidine-iodine, with stoichiometry 1:1 grown from benzene, have been studied under high pressures upto 6 GPa atT=300 K andT=77 K. The characteristics show a pronounced deviation from ohmicity beyond a certain current for all pressures studied. At room temperature, beyond a threshold field the system switches from a low conductingOFF state to a high conductingON state with σON/σOFF ∼ 103. TheOFF state can be restored by the application of an a.c. pulse of low frequency. The temperature dependence of the two states studied indicates that theOFF state is semiconducting while theON state, beyond a certain applied pressure is metallic. The characteristics atT=77 K do not show any switching.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tuberefrigerator.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A numerical modelling technique for predicting the detailed performance of a double-inlet type two-stage pulse tube refrigerator has been developed. The pressure variations in the compressor, pulse tube, and reservoir were derived, assuming the stroke volume variation of the compressor to be sinusoidal. The relationships of mass flowrates, volume flowrates, and temperature as a function of time and position were developed. The predicted refrigeration powers are calculated by considering the effect of void volumes and the phase shift between pressure and mass flowrate. These results are compared with the experimental results of a specific pulse tube refrigerator configuration and an existing theoretical model. The analysis shows that the theoretical predictions are in good agreement with each other.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An atmospheric radio noise burst represents the radiation received from one complete lightning flash at the frequency to which a receiver is tuned and within the receiver bandwidth. At tropical latitudes, the principal source of interference in the frequency range from 0.1 to 10 MHz is the burst form of atmospheric radio noise. The structure of a burst shows several approximately rectangular pulses of random amplitude, duration and frequency of recurrence. The influence of the noise on data communication can only be examined when the value of the number of pulses crossing a certain amplitude threshold per unit time of the noise burst is known. A pulse rate counter designed for this purpose has been used at Bangalore (12°58′N, 77°35′E) to investigate the pulse characteristics of noise bursts at 3 MHz with a receiver bandwidth of 3.3 kHz/6d B. The results show that the number of pulses lying in the amplitude range between peak and quasi-peak values of the noise bursts and the burst duration corresponding to these pulses follow log normal distributions. The pulse rates deduced therefrom show certain correlation between the number of pulses and the duration of the noise burst. The results are discussed with a view to furnish necessary information for data communication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is presented for obtaining lower bound on the carrying capacity of reinforced concrete foundation slab-structures subject to non-uniform contact pressure distributions. Functional approach suggested by Vallance for simply supported square slabs subject to uniform pressure distribution has been extended to simply supported rectangular slabs subject to symmetrical non-uniform pressure distributions. Radial solutions, ideally suited for rotationally symmetric problems, are shown to be adoptable for regular polygonal slabs subject to contact pressure paraboloids with constant edge pressures. The functional approach has been shown to be well suited even when the pressure is varying along the edges.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow through a rectangular Passage which is expanded suddenly into another rectangular duct of larger Cross-sectional area has been studied experimentally with stagnation Pressures from 3.5 atmospheres to 1.25 atmospheres. The length to height ratio of the enlarged duct varied from 5.769 to 1.923 and three models with length to height ratios 5.769, 3.846, and 1.923 were studied. The influence of stagnation Pressures and length to height ratio of the enlarged duct on base pressure and flow field mean pressures in the enlarged duct is discussed. The results of the present investigation indicate that the oscillatory nature of the mean pressure flow field in the enlarged portion with rectangular cross-section is appreciably different from that for circular cross-section at similar flow conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an analytical calculation of break-out noise from a rectangular plenum with four flexible walls by incorporating three-dimensional effects along with the acoustical and structural wave coupling phenomena. The breakout noise from rectangular plenums is important and the coupling between acoustic waves within the plenum and structural waves in the flexible plenum walls plays a critical role in prediction of the transverse transmission loss. The first step in breakout noise prediction is to calculate the inside plenum pressure field and the normal flexible plenum wall vibration by using an impedance-mobility approach, which results in a compact matrix formulation. In the impedance-mobility compact matrix (IMCM) approach, it is presumed that the coupled response can be described in terms of finite sets of the uncoupled acoustic subsystem and the structural subsystem. The flexible walls of the plenum are modeled as an unfolded plate to calculate natural frequencies and mode shapes of the uncoupled structural subsystem. The second step is to calculate the radiated sound power from the flexible walls using Kirchhoff-Helmholtz (KH) integral formulation. Analytical results are validated with finite element and boundary element (FEM-BEM) numerical models. (C) 2010 Acoustical Society of America. DOI: 10.1121/1.3463801]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three-dimensional effects are a primary source of discrepancy between the measured values of automotive muffler performance and those predicted by the plane wave theory at higher frequencies. The basically exact method of (truncated) eigenfunction expansions for simple expansion chambers involves very complicated algebra, and the numerical finite element method requires large computation time and core storage. A simple numerical method is presented in this paper. It makes use of compatibility conditions for acoustic pressure and particle velocity at a number of equally spaced points in the planes of the junctions (or area discontinuities) to generate the required number of algebraic equations for evaluation of the relative amplitudes of the various modes (eigenfunctions), the total number of which is proportional to the area ratio. The method is demonstrated for evaluation of the four-pole parameters of rigid-walled, simple expansion chambers of rectangular as well as circular cross-section for the case of a stationary medium. Computed values of transmission loss are compared with those computed by means of the plane wave theory, in order to highlight the onset (cutting-on) of various higher order modes and the effect thereof on transmission loss of the muffler. These are also compared with predictions of the finite element methods (FEM) and the exact methods involving eigenfunction expansions, in order to demonstrate the accuracy of the simple method presented here.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Breakout noise from HVAC ducts is important at low frequencies, and the coupling between the acoustic waves and the structural waves plays a critical role in the prediction of the transverse transmission loss. This paper describes the analytical calculation of breakout noise by incorporating three-dimensional effects along with the acoustical and structural wave coupling phenomena. The first step in the breakout noise prediction is to calculate the inside duct pressure field and the normal duct wall vibration by using the solution of the governing differential equations in terms of Green's function. The resultant equations are rearranged in terms of impedance and mobility, which results in a compact matrix formulation. The Green's function selected for the current problem is the cavity Green's function with modification of wave number in the longitudinal direction in order to incorporate the terminal impedance. The second step is to calculate the radiated sound power from the compliant duct walls by means of an ``equivalent unfolded plate'' model. The transverse transmission loss from the duct walls is calculated using the ratio of the incident power due to surface source inside the duct to the acoustic power radiated from the compliant duct walls. Analytical results are validated with the FE-BE numerical models.