998 resultados para RELATIVE AIR HUMIDITY


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m³). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m³. The offices' results showed dispersion around 300 CFU/m³. The hospitals' results presented the same trend, with an average of 200 CFU/m³. Shopping centers' environments showed an average of 300 CFU/m³ for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m³). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar. The temperature and air humidity had no significant influence on the samples dispersion patterns.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Environmental conditions play a crucial role in mite growth, and optimal environmental control is key in the prevention of airway inflammation in chronic allergic rhinoconjunctivitis or asthma. OBJECTIVE: To evaluate the relationship between building energy performance and indoor mite allergen concentration in a cross-sectional study. METHODS: Major allergen concentration (Der f 1, Der p 1, mite group 2, Fel d 1 and Bla g 2) was determined by quantitative dot blot analysis from mattress and carpet dust samples in five buildings designed for low energy use (LEB) and in six control buildings (CB). Inhabitants had received 4 weeks prior to mite measurement a personal validated questionnaire related to the perceived state of health and comfort of living. RESULTS: Cumulative mite allergen concentration (with Der f 1 as the major contributor) was significantly lower in LEB as compared with CB both in mattresses and in carpets. In contrast, the two categories of buildings did not differ in Bla g 2 and Fel d 1 concentration, in the amount of dust and airborne mould collected. Whereas temperature was higher in LEB, relative humidity was significantly lower than in CB. Perceived overall comfort was better in LEB. CONCLUSIONS: Major mite allergen Der f 1 preferentially accumulates in buildings not specifically designed for low energy use, reaching levels at risk for sensitization. We hypothesize that controlled mechanical ventilation present in all audited LEB may favour lower air humidity and hence lower mite growth and allergen concentration, while preserving optimal perceived comfort.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Context: Anthropogenic activity has increased the level of atmospheric CO2, which is driving an increase of global temperatures and associated changes in precipitation patterns. At Northern latitudes, one of the likely consequences of global warming is increased precipitation and air humidity. Aims: In this work, the effects of both elevated atmospheric CO2 and increased air humidity on trees commonly growing in northern European forests were assessed. Methods: The work was carried out under field conditions by using Free Air Carbon dioxide Enrichment (FACE) and Free Air Humidity Manipulation (FAHM) systems. Leaf litter fall was measured over 4 years (FACE) or 5 years (FAHM) to determine the effects of FACE and FAHM on leaf phenology. Results: Increasing air humidity delayed leaf litter fall in Betula pendula, but not in Populus tremula × tremuloides. Similarly, under elevated atmospheric CO2, leaf litter fall was delayed in Betula pendula, but not in Alnus glutinosa. Increased CO2 appeared to interact with periods of low precipitation in summer and high ozone levels during these periods to effect leaf fall. Conclusions: This work shows that increased CO2 and humidity delay leaf fall, but this effect is species specific.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper aims to evaluate the physiological quality of Sebastiania commersoniana seeds stored in cloth bag, plastic bag and glass container and kept in two conditions: laboratory workbench and cold chamber (4 ± 2°C e 80% relative humidity - RH) for 531 days. Periodically, samples were taken in order to determine the moisture content and to perform germination tests. The experimental design was completely randomized, in factorial scheme of 3 × 2 (wrappings × conditions), for each period of storage evaluated (0, 158, 271, 389 and 531 days of storage). Supplementary, a polynomial regression was adjusted in order to describe the physiological quality of the seeds for the different conditions during the experimental period. The results lead to the following considerations: a) storage under variable temperature and air humidity (laboratory workbench) can be used for periods of over five and a half months, with the seeds stored in cloth bag, plastic bag or glass container; b) the physiological quality of the seeds was not hardly altered when stored in cold chamber in cloth bag, plastic bag and glass container for over 18 months.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to evaluate and compare measurements and estimates from Davis and Campbell Scientific Instruments in two automatic weather stations. Integrity of meteorological data for estimates of evapotranspiration of reference crop (ETo) from both stations was also evaluated. The following meteorological data were evaluated: air temperature, air humidity, wind speed, precipitation, net radiation and global solar radiation. The Penman-Monteith reference method to estimate ETo was evaluated daily. The weather stations were set up in an experimental area of the Rural Engineering Department-FACV/ UNESP, in Jaboticabal, State of Sao Paulo. Data were collected daily and statistical analysis was performed using linear regression analysis. The integrity of meteorological data to estimate ETo was evaluated. The results of the study in the stations using linear regression analysis showed that daily estimates for ETo had acceptable differences. The technique which evaluates the integrity of meteorological data revealed that data of relative humidity from both stations and of precipitation using Campbell Instruments were not good.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aimed to analyze the characteristics of temperature and air humidity from neighborhoods of Presidente Prudente according to the pattern of land use specific to each of them, over a representative period of winter (July 2011), at different times of day in order to identify the major changes in climatic elements and their causes in urban areas. The work is based mainly on the Monteiro’s theory (1976) of Urban Climate System and for its implementation was used data of temperature and relative humidity of the air in three urban neighborhoods and one rural area. With them, a Chart of Rhythmic Analysis was elaborated for identification of the operating atmospherics systems and basic climate conditions in the period. Were prepared, also, graphs and charts to evaluate and compare the data. There were significant differences in the characteristics of temperature and air humidity between the neighborhoods, especially when compared the urban areas with the rural area

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)