992 resultados para RAPID DIAGNOSIS
Resumo:
Cell culture and direct fluorescent antibody (DFA) assays have been traditionally used for the laboratory diagnosis of respiratory viral infections. Multiplex reverse transcriptase polymerase chain reaction (m-RT-PCR) is a sensitive, specific, and rapid method for detecting several DNIA and RNA viruses in a single specimen. We developed a m-RT-PCR assay that utilizes multiple virus-specific primer pairs in a single reaction mix combined with an enzyme-linked amplicon hybridization assay (ELAHA) using virus-specific probes targeting unique gene sequences for each virus. Using this m-RT-PCR-ELAHA, we examined the presence of seven respiratory viruses in 598 nasopharyngeal aspirate (NPA) samples from patients with suspected respiratory infection. The specificity of each assay was 100%. The sensitivity of the DFA was 79.7% and the combined DFA/culture amplified-DFA (CA-DFA) was 88.6% when compared to the m-RT-PCR-ELAHA. Of the 598 NPA specimens screened by m-RT-PCR-ELAHA, 3% were positive for adenovirus (ADM), 2% for influenza A (Flu A) virus, 0.3% for influenza B (Flu B) virus, 1% for parainfluenza type I virus (PIV1), 1% for parainfluenza type 2 virus (PIV2), 5.5% for parainfluenza type 3 virus (PIV3), and 21% for respiratory syncytial virus (RSV). The enhanced sensitivity, specificity, rapid result turnaround time and reduced expense of the m-RT-PCR-ELAHA compared to DFA and CA-DFA, suggests that this assay would be a significant improvement over traditional assays for the detection of respiratory viruses in a clinical laboratory.
Resumo:
RATIONALE: Limitations in methods for the rapid diagnosis of hospital-acquired infections often delay initiation of effective antimicrobial therapy. New diagnostic approaches offer potential clinical and cost-related improvements in the management of these infections. OBJECTIVES: We developed a decision modeling framework to assess the potential cost-effectiveness of a rapid biomarker assay to identify hospital-acquired infection in high-risk patients earlier than standard diagnostic testing. METHODS: The framework includes parameters representing rates of infection, rates of delayed appropriate therapy, and impact of delayed therapy on mortality, along with assumptions about diagnostic test characteristics and their impact on delayed therapy and length of stay. Parameter estimates were based on contemporary, published studies and supplemented with data from a four-site, observational, clinical study. Extensive sensitivity analyses were performed. The base-case analysis assumed 17.6% of ventilated patients and 11.2% of nonventilated patients develop hospital-acquired infection and that 28.7% of patients with hospital-acquired infection experience delays in appropriate antibiotic therapy with standard care. We assumed this percentage decreased by 50% (to 14.4%) among patients with true-positive results and increased by 50% (to 43.1%) among patients with false-negative results using a hypothetical biomarker assay. Cost of testing was set at $110/d. MEASUREMENTS AND MAIN RESULTS: In the base-case analysis, among ventilated patients, daily diagnostic testing starting on admission reduced inpatient mortality from 12.3 to 11.9% and increased mean costs by $1,640 per patient, resulting in an incremental cost-effectiveness ratio of $21,389 per life-year saved. Among nonventilated patients, inpatient mortality decreased from 7.3 to 7.1% and costs increased by $1,381 with diagnostic testing. The resulting incremental cost-effectiveness ratio was $42,325 per life-year saved. Threshold analyses revealed the probabilities of developing hospital-acquired infection in ventilated and nonventilated patients could be as low as 8.4 and 9.8%, respectively, to maintain incremental cost-effectiveness ratios less than $50,000 per life-year saved. CONCLUSIONS: Development and use of serial diagnostic testing that reduces the proportion of patients with delays in appropriate antibiotic therapy for hospital-acquired infections could reduce inpatient mortality. The model presented here offers a cost-effectiveness framework for future test development.
Resumo:
Diagnostic techniques based on PCR have two major problems: false-positive reactions due to contamination with DNA fragments from previous PCRs (amplicons) and false-negative reactions caused by inhibitors that interfere with the PCR. We have improved our previously reported PCR based on the amplification of a fragment of the Mycobacterium tuberculosis complex-specific insertion element IS6110 with respect to both problems. False-positive reactions caused by amplicon contamination were prevented by the use of uracil-N-glycosylase and dUTP instead of dTTP. We selected a new set of primers outside the region spanned by the formerly used primers to avoid false-positive reactions caused by dTTP-containing amplicons still present in the laboratory. With this new primer set, 16 copies of the IS6110 insertion element, the equivalent of two bacteria, could be amplified 10(10) times in 40 cycles, resulting in a mean efficiency of 77% per cycle. To detect the presence of inhibitors of the Taq polymerase, which may cause false-negative reactions, part of each sample was spiked with M. tuberculosis DNA. The DNA purification method using guanidinium thiocyanate and diatoms effectively removed most or all inhibitors of the PCR. However, this was not suitable for blood samples, for which we developed a proteinase K treatment followed by phenol-chloroform extraction. This method permitted detection of 20 M. tuberculosis bacteria per ml of whole blood. Various laboratory procedures were introduced to reduce failure or inhibition of PCR and avoid DNA cross contamination. We have tested 218 different clinical specimens obtained from patients suspected of having tuberculosis. The samples included sputum (n=145), tissue biopsy samples (n=25), cerebrospinal fluid (n=15), blood (n=14), pleural fluid (n=9), feces, (n=7), fluid from fistulae (n=2), and pus from a wound (n=1). The results obtained by PCR were consistent with those obtained with culture, which is the "gold standard." We demonstrate that PCR is a useful technique for the rapid diagnosis of tuberculosis at various sites.
Resumo:
From their early days, Electrical Submergible Pumping (ESP) units have excelled in lifting much greater liquid rates than most of the other types of artificial lift and developed by good performance in wells with high BSW, in onshore and offshore environments. For all artificial lift system, the lifetime and frequency of interventions are of paramount importance, given the high costs of rigs and equipment, plus the losses coming from a halt in production. In search of a better life of the system comes the need to work with the same efficiency and security within the limits of their equipment, this implies the need for periodic adjustments, monitoring and control. How is increasing the prospect of minimizing direct human actions, these adjustments should be made increasingly via automation. The automated system not only provides a longer life, but also greater control over the production of the well. The controller is the brain of most automation systems, it is inserted the logic and strategies in the work process in order to get you to work efficiently. So great is the importance of controlling for any automation system is expected that, with better understanding of ESP system and the development of research, many controllers will be proposed for this method of artificial lift. Once a controller is proposed, it must be tested and validated before they take it as efficient and functional. The use of a producing well or a test well could favor the completion of testing, but with the serious risk that flaws in the design of the controller were to cause damage to oil well equipment, many of them expensive. Given this reality, the main objective of the present work is to present an environment for evaluation of fuzzy controllers for wells equipped with ESP system, using a computer simulator representing a virtual oil well, a software design fuzzy controllers and a PLC. The use of the proposed environment will enable a reduction in time required for testing and adjustments to the controller and evaluated a rapid diagnosis of their efficiency and effectiveness. The control algorithms are implemented in both high-level language, through the controller design software, such as specific language for programming PLCs, Ladder Diagram language.
Resumo:
Antecedente: La infección por el virus sincitial respiratorio (VSR) representa una elevada morbimortalidad, y en algunos casos necesidad de manejo en unidades de cuidado intensivo pediátrico (UCIP). La respuesta inmunológica influye de manera directa en la expresión de la severidad y pronóstico de los pacientes con infección respiratoria. Metodología: Estudio de una cohorte retrospectiva de pacientes con infección respiratoria grave secundaria a VSR, sin historia de inmunodeficiencia, atendidos en la UCIP del Hospital Universitario Clínica San Rafael. Se realizó análisis descriptivoglobaly de acuerdo a la categorización de las prueba de IgG. Resultados: De 188 pacientes que ingresaron a la UCIP, 13% presentaron infección por VSR (24), con una edad promedio de 7,3 (DE=3,6) meses. Pertenecían al sexo masculino79,83%. Se encontró que 12,5% tenían un valor de IgGbajo para su edad, 58,33% tenían valores en límite inferior y el 29,17% dentro de rangos normales para su edad. En los pacientes con IgG baja, fue mayor la presentación de choque séptico que no responde a líquidos (100 vs 92 vs 86%), la mediana de días de ventilación mecánica fue mayor (8 vs 6 vs 5 respectivamente), así como la mortalidad (67 vs 7,1 vs 0%). Conclusión: Nuestra serie encontró que aquellos pacientes con niveles bajos o valores en el límite inferior de IgG sérica tuvieron mayor compromiso sistémico, mayor duración de ventilación mecánica y mayor mortalidad. Se necesitan estudios prospectivos que relaciones niveles bajos de IgG con severidad y pronostico en estos pacientes con infección grave por VSR.
Resumo:
The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.
Resumo:
The performances of two rapid tests and a standard serological test for the diagnosis of visceral leishmaniasis (VL) were compared using sera from 193 patients with VL and 85 controls. The Kala-Azar Detect®, IT-LEISH® and IFI-LH® assays showed sensitivities of 88.1%, 93.3% and 88.6%, respectively, and specificities of 90.6%, 96.5% and 80%, respectively. The sensitivity values were similar for both rapid tests, but the specificity and positive predictive values of IT-LEISH® were higher than the corresponding values for IFI-LH®. Both rapid tests showed satisfactory performances and can be used in primary health care settings; however, IT-LEISH® permits the use of whole blood, making this assay more suitable for bedside diagnosis.
Resumo:
Some sites of extrapulmonary tuberculosis and focal complications of brucellosis are very difficult to differentiate clinically, radiologically, and even histopathologically. Conventional microbiological methods for the diagnosis of extrapulmonary tuberculosis and complicated brucellosis not only lack adequate sensitivity, they are also time consuming, which could lead to an unfavourable prognosis. The aim of this work was to develop a multiplex real-time PCR assay based on SYBR Green I to simultaneously detect Brucella spp and Mycobacterium tuberculosis complex and evaluate the efficacy of the technique with different candidate genes. The IS711, bcsp31 and omp2a genes were used for the identification of Brucella spp and the IS6110, senX3-regX3 and cfp31 genes were targeted for the detection of the M. tuberculosis complex. As a result of the different combinations of primers, nine different reactions were evaluated. A test was defined as positive only when the gene combinations were capable of co-amplifying both pathogens in a single reaction tube and showed distinguishable melting temperatures for each microorganism. According to the melting analysis, only three combinations of amplicons (senX3-regX3+bcsp31, senX3-regX3+IS711 and IS6110+IS711) were visible. Detection limits of senX3-regX3+bcsp31 and senX3-regX3+IS711 were of 2 and 3 genome equivalents for M. tuberculosis complex and Brucella while for IS6110+IS711 they were of 200 and 300 genome equivalents, respectively. The three assays correctly identified all the samples, showing negative results for the control patients. The presence of multicopy elements and GC content were the components most influencing the efficiency of the test; this should be taken into account when designing a multiplex-based SYBR Green I assay. In conclusion, multiplex real time PCR assays based on the targets senX3-regX3+bcsp31 and senX3-regX3+IS711 using SYBR Green I are highly sensitive and reproducible. This may therefore be a practical approach for the rapid differential diagnosis between extrapulmonary tuberculosis and complicated brucellosis.
Resumo:
Aikuispotilaan kotisyntyisen keuhkokuumeen etiologinen diagnostiikka mikrobiologisilla pikamenetelmillä Tausta. Keuhkokuume on vakava sairaus, johon sairastuu Suomessa vuosittain n. 60 000 aikuista. Huolimatta siitä, että taudin hoito on kehittynyt, siihen liittyy yhä merkittävä, 6-15%:n kuolleisuus. Alahengitystieinfektion aiheuttajamikrobien tunnistaminen on myös edelleen haasteellista. Tavoitteet. Tämän työn tavoitteena oli tutkia Turun yliopistollisessa keskussairaalassa hoidettujen aikuispotilaiden keuhkokuumeen etiologiaa sekä selvittää uusien mikrobiologisten pikamenetelmi¬en hyödyllisyyttä taudinaiheuttajan toteamisessa. Aineisto. Osatöiden I ja III aineisto koostui 384 Turun yliopistollisen keskussairaalaan infektio-osastolla hoidetusta keuhkokuumepotilaasta. Osatyössä I tutkittiin keuhkokuumeen aiheuttaja¬mikrobeja käyttämällä perinteisten menetelmien lisäksi antigeeniosoitukseen ja PCR-tekniikkaan perustuvia pikamenetelmiä. Osatyö II käsitti 231 potilaasta koostuvan alaryhmän, jossa tutkittiin potilaiden nielun limanäytteestä rinovirusten ja enterovirusten esiintyvyyttä. Osatyössä III potilailta tutkittiin plasman C-reaktiivisen proteiinin (CRP) pitoisuus ensimmäisten viiden sairaalahoitopäi¬vän aikana. Laajoja tilastotieteellisiä analyysejä käyttämällä selvitettiin CRP:n käyttökelpoisuutta sairauden vaikeusasteen arvioinnissa ja komplikaatioiden kehittymisen ennustamisessa. Osatyössä IV 68 keuhkokuumepotilaan sairaalaan tulovaiheessa otetuista näytteistä määritettiin neutrofiilien pintareseptorien ekspressio. Osatyössä V analysoitiin sisätautien vuodeosastoilla vuosina 1996-2000 keuhkokuumepotilaille tehtyjen keuhkohuuhtelunäytteiden laboratoriotutkimustulokset. Tulokset. Keuhkokuumeen aiheuttaja löytyi 209 potilaalta, aiheuttajamikrobeja löydettiin kaikkiaan 230. Näistä aiheuttajista 135 (58.7%) löydettiin antigeenin osoituksella tai PCR-menetelmillä. Suu¬rin osa, 95 (70.4%), todettiin pelkästään kyseisillä pikamenetelmillä. Respiratorinen virus todettiin antigeeniosoituksella 11.1% keuhkokuumepotilaalla. Eniten respiratorisia viruksia löytyi vakavaa keuhkokuumetta sairastavilta potilailta (20.3%). 231 keuhkokuumepotilaan alaryhmässä todettiin PCR-menetelmällä picornavirus 19 (8.2%) potilaalla. Respiratorinen virus löytyi tässä potilasryh¬mässä kaiken kaikkiaan 47 (20%) potilaalta. Näistä 17:llä (36%) löytyi samanaikaisesti bakteerin aiheuttama infektio. CRP-tasot olivat sairaalaan tulovaiheessa merkitsevästi korkeammat vakavaa keuhkokuumetta (PSI-luokat III-V) sairastavilla potilailla kuin lievää keuhkokuumetta (PSI-luokat I-II) sairastavilla potilailla (p <0.001). Yli 100 mg/l oleva CRP-taso neljän päivän kuluttua sairaa¬laan tulosta ennusti keuhkokuumeen komplikaatiota tai huonoa hoitovastetta. Neutrofiilien komple¬menttireseptorin ekspressio oli pneumokokin aiheuttamaa keuhkokuumetta sairastavilla merkitse¬västi korkeampi kuin influenssan aiheuttamaa keuhkokuumetta sairastavilla. BAL-näytteistä vain yhdessä 71:stä (1.3%) todettiin diagnostinen bakteerikasvu kvantitatiivisessa viljelyssä. Uusilla menetelmilläkin keuhkokuumeen aiheuttaja löytyi vain 9.8% BAL-näytteistä. Päätelmät. Uusilla antigeeniosoitus- ja PCR-menetelmillä keuhkokuumeen etiologia voidaan saada selvitettyä nopeasti. Lisäksi näitä menetelmiä käyttämällä taudin aiheuttajamikrobi löytyi huomattavasti suuremmalta osalta potilaista kuin pelkästään tavanomaisia menetelmiä käyttämällä. Pikamenetelmien hyödyllisyys vaihteli taudin vaikeusasteen mukaan. Respiratorinen virus löytyi huomattavan usein keuhkokuumetta sairastavilta potilailta, ja näiden potilaiden taudinkuva oli usein vaikea. Tulovaiheen korkeaa CRP-tasoa voidaan käyttää lisäkeinona arvioitaessa keuhkokuumeen vaikeutta. CRP on erityisen hyödyllinen arvioitaessa hoitovastetta ja riskiä komplikaatioiden ke¬hittymiseen. Neutrofiilien komplementtireseptorin ekspression tutkiminen näyttää lupaavalta pi¬kamenetelmältä erottamaan bakteerien ja virusten aiheuttamat taudit toisistaan. Antimikrobihoitoa saavilla potilailla BAL-tutkimuksen löydökset olivat vähäiset ja vaikuttivat hoitoon vain harvoin.
Resumo:
Bovine leukaemia virus (BLV) is the causative agent of enzootic bovine leukosis (EBL). In Argentina, where a program to eradicate EBL has been introduced, sensitive and reliable diagnosis has attained high priority. Although the importance of the agar gel immunodiffusion test remains unchanged for routine work, an additional diagnostic technique is necessary to confirm cases of sera with equivocal results or of calves carrying maternal antibodies.Utilizing a nested shuttle polymerase chain reaction, the proviral DNA was detected from cows experimentally infected with as little as 5 ml of whole blood from BLV seropositive cows that were nonetheless normal in haematological terms. It proved to be a very sensitive technique, since it rapidly revealed the presence of the provirus, frequently at 2 weeks postinoculation and using a two-round procedure of nested PCR taking only 3 hours. Additionally, the primers used flanked a portion of the viral genome often employed to differentiate BLV type applying BamHI digestion. It is concluded that this method might offer a highly promising diagnostic tool for BLV infection.
Resumo:
The performance of the rapid slide agglutination test, with and without 2-mercaptoethanol (RSAT and 2ME-RSAT) and agar gel immunodiffusion test (AGID) was evaluated for the diagnosis of brucellosis in naturally infected dogs. The microbiological culture, PCR and clinical parameters were used as reference. A total of 167 dogs were clinically examined and tested by blood culture, culture of semen/vaginal swab and PCR in blood and semen/vaginal swab. According to the results observed the 167 dogs were divided into three groups: Brucella canis infected dogs (Group 1). B. canis non-infected dogs (Group 2) and dogs with suspected brucellosis (Group 3). The dogs were then tested by RSAT, 2ME-RSAT and AGID. Groups 1 and 2 were used to calculate the diagnostic sensitivity and specificity of the serological tests and the results observed in Group 3 were also discussed. The diagnostic sensitivity of RSAT, 2ME-RSAT and AGID was respectively 70.58%, 31.76%, and 52.94%. The diagnostic specificity of RSAT, 2ME-RSAT and AGID was respectively 83.34%, 100%, and 100%. In dogs with suspected brucellosis 15% were RSAT positive, none was 2ME-RSAT positive and 5% were AGID positive. Although the serological tests are the most commonly used methods for brucellosis diagnosis, a significant proportion of false-negative results were observed highlighting the importance of the direct methods of diagnosis, like blood culture and PCR to improve the diagnosis of canine brucellosis. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)