246 resultados para Premolar


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimTo study osseointegration and bone-level changes at implants installed using either a standard or a reduced diameter bur for implant bed preparation.Material and methodsIn six Labrador dogs, the first and second premolars were extracted bilaterally. Subsequently, mesial roots of the first molars were endodontically treated and distal roots, including the corresponding part of the crown, were extracted. After 3 months of healing, flaps were elevated and recipient sites were prepared in all experimental sites. The control site was prepared using a standard procedure, while the test site was prepared using a drill with a 0.2 mm reduced diameter than the standard one used in the contra-lateral side. After 4 months of healing, the animals were euthanized and biopsies were obtained for histological processing and evaluation.ResultsWith the exception of one implant that was lost, all implants were integrated in mineralized bone. The alveolar crest underwent resorption at control as well as at test sites (buccal aspect similar to 1 mm). The most coronal contact of bone-to-implant was located between 1.2 and 1.6 mm at the test and between 1.3 and 1.7 mm at the control sites. Bone-to-implant contact percentage was between 49% and 67%. No statistically significant differences were found for any of the outcome variables.ConclusionsAfter 4 months of healing, lateral pressure to the implant bed as reflected by higher insertion torques (36 vs. 15 N cm in the premolar and 19 vs. 7 N cm in the molar regions) did not affect the bone-to-implant contact.To cite this article:Pantani F, Botticelli D, Garcia IR Jr., Salata LA, Borges GJ, Lang NP. Influence of lateral pressure to the implant bed on osseointegration: an experimental study in dogs.Clin. Oral Impl. Res. 21, 2010; 1264-1270.doi: 10.1111/j.1600-0501.2009.01941.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimTo evaluate the influence (i) of various implant platform configurations and (ii) of implant surface characteristics on peri-implant tissue dimensions in a dog model.Material and methodsMandibular premolars and first molars were extracted bilaterally in six Labrador dogs. After 3 months of healing, two implants, one with a turned and a second with a moderately rough surface, were installed on each side of the mandible in the premolar region. on the right side of the mandible, implants with a tapered and enlarged platform were used, while standard cylindrical implants were installed in the left side of the mandible. Abutments with the diameter of the cylindrical implants were used resulting in a mismatch of 0.25 mm at the tapered implant sites. The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.ResultsAll implants were completely osseointegrated. A minimal buccal bone resorption was observed for both implant configurations and surface topographies. Considering the animals as the statistical unit, no significant differences were found at the buccal aspect in relation to bone levels and soft tissue dimensions. The surface topographies did not influence the outcomes either.ConclusionsThe present study failed to show differences in peri-implant tissue dimensions when a mismatch of 0.25 mm from a tapered platform to an abutment was applied. The surface topographies influence a neither marginal bone resorption or peri-implant soft tissue dimension.To cite this article:Baffone GM, Botticelli D, Pantani F, Cardoso LC, Schweikert MT, Lang NP. Influence of various implant platform configurations on peri-implant tissue dimensions: an experimental study in dog.Clin. Oral Impl. Res. 22, 2011; 438-444.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the presence of both adjacent teeth on the level of alveolar bony crest at sites where implants were installed into the socket immediately after tooth extraction.Material and methods: Six Labrador dogs were used. Extractions of all teeth from the second premolar to the first molar were performed in the right side of the mandible, after full-thickness flap elevation. In the left side of the mandible, an endodontic treatment of the mesial root of the third and fourth premolars was performed. Full-thickness flaps were elevated, the teeth hemisected, and the distal roots removed. Immediately after, implants were bilaterally installed with the margin flush to the buccal bony crest. The implants were placed in the center of the alveolus at the third premolars and toward the lingual bony plate of the alveolus at the fourth premolars. After 3 months of healing, the animals were euthanized.Results: All implants were integrated in mature bone. More bone resorption was observed at the test compared to the control sites. At the buccal aspect, a resorption of 2.8 +/- 0.5 and 1.6 +/- 0.4 mm at the third premolars and of 2.4 +/- 0.6 and 0.8 +/- 0.7 mm at the fourth premolars were found, at the test and control sites, respectively. At the lingual aspect, the bony crest was apically located in relation to the implant shoulder 1.5 +/- 0.3 and 0.5 +/- 0.5 mm at the third premolars and 1.6 +/- 0.6 and 0.3 +/- 1.1 mm at the fourth premolars, at the test and control sites, respectively. A lower buccal bone resorption was found at the control implants placed lingually.Conclusion: Multiple extractions of teeth adjacent to a socket into which implants were installed immediately after, tooth extraction induced more alveolar bone recession compared to sites where the adjacent teeth were preserved. Moreover, an implant placed more lingually yielded less recession of the buccal aspect of the implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Taurodontism does not involve molar teeth exclusively. To call attention to the occurrence of this phenomenon in premolars, 4,459 extracted mandibular and maxillary premolars were examined. Eleven showed evidence of taurodontism. Roentgenograms taken from a buccolingual direction confirmed the diagnosis of taurodont teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this article was to compare, through the distillation method, the incorporated amount of fluoride and the reduction of solubility in the enamel of both deciduous and young permanent teeth, following topical application of a 2% neutral sodium fluoride solution, according to the Knutson's technique and a 1.23% of acidulated solution, according to the Wellock & Brudevold's technique. The greatest fluoride incorporation was observed in the deciduous teeth after the usage of the 2% neutral solution. The amount of calcium and phosphorus liberation by the acid solution was greatest in the control group, followed by the group of teeth treated in acidulated solution and, finally, by those treated in 2% sodium fluoride solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to investigate the cervical marginal leakage in class II restorations with chemically cured resin (P10) and light-cured resin (P30) in two types of cavities: conventional and adhesive. The effect of acid-etching in this area was also observed. Dentine adhesive Scotchbond was used in all experimental groups. Leakage was evidenced by Rodamina B dye penetration after thermocycling procedure between 10 degrees C and 50 degrees C temperature and analysed by using Zeiss Stereoscopic Magnifying Glass (10 X). According to the results obtained marginal leakage occurred in all experimental groups, with lower percentage for adhesives cavities when enamel acid-etching and light-cured resin P30 was used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the penetration of a light-cured glass ionomer and a resin sealant into occlusal fissures and etched enamel. MATERIALS AND METHODS: Forty-eight maxillary and mandibular caries-free premolars scheduled for extraction for orthodontic reasons were isolated, the occlusal surfaces subjected to prophylaxis and acid-etched with orthophosphoric acid prior to the application of the VariGlass VLC glass ionomer and Concise resin sealants. The teeth were extracted, two longitudinal median sectiors from each tooth were ground to a thickness of 80-100 microns, and the sealant penetration into the fissures evaluated. The sections were placed in nitric acid to dissolve the enamel so the lengths of the tags which had penetrated into the etched enamel could be measured at different sites on the walls of the fissures. RESULTS: Both sealants adapted well to the fissures but penetrated deeper into shallow, open fissures than into deep, constricted fissures. The VariGlass VLC tags into etched enamel were generally longer than the Concise projections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the microleakage of pit and fissure sealants after different surface preparation (invasive technique and laser irradiation) and the use of different materials (fluoride resin-filled sealant, resin-modified glass ionomer cement and adhesive system). Eighty-four pre molars were used in this study, which were divided into seven groups. After the accomplishment of the different treatments, these were submitted to thermocycling process and assess for microleakage by examination under an epifluorescent microscope and scored zero to seven. Two specimens of each group were observed under scanning electron microscope (SEM). The results showed that laser irradiation did not lessen microleakage in pit and fissures when using a filled-resin sealant with fluoride or a resin-modified glass ionomer cement. The use of laser irradiation and adhesive system, followed by a resin-filled sealant with fluoride, showed the lowest microleakage scores in pit and fissures. Comparing this group to the resin-modified glass ionomer cement group, there was statistical significance. The use of a adhesive system decreased microleakage when using a fluoride resin-filled sealant with or without previous laser irradiation; although it was not statistically significant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this implant study was to evaluate the transverse stability of the basal maxillary and mandibular structures. The sample included 25 subjects between 12 and 18 years of age who were followed for approximately 2.6 years. Metallic implants were placed bilaterally into the maxillary and mandibular corpora before treatment. Once implant stability had been confirmed, treatment (4 first premolar extractions followed by fixed appliance therapy) was initiated. Changes in the transverse maxillary and mandibular implants were evaluated cephalometrically and two groups (GROW+ and GROW++; selection based on growth changes in facial height and mandibular length) were compared. The GROW++ group showed significant width increases of the posterior maxillary implants (P <.001) and the mandibular implants (P =.009); there was no significant change for the anterior maxillary implants. The GROW+ group showed no significant width changes between the maxillary and mandibular implants. We conclude that (1) there are significant width increases during late adolescence of the basal mandibular and maxillary skeletal structures and (2) the width changes are related with growth potential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare the removal of root surface smear layer following active application of EDTA gel and EDTA-T (texapon) gel in different concentrations (5%, 10%, 15%, 20% and 24%), using scanning electron microscopy. A total of 220 dentin blocks obtained from the root surfaces of extracted teeth were divided into 3 groups: Group I - (control) application of saline solution (n = 20); Group II - EDTA gel (pH 7.0) was applied in the following concentrations: 5%, 10%, 15%, 20% and 24% (n = 100); Group III - EDTA-T gel (pH 7.0) applied in the same concentrations described above (n = 100). The photomicrographs were evaluated by one calibrated examiner using a smear layer removal index and following statistical analysis (Kruskal-Wallis test). The results demonstrated that the specimens treated with EDTA and EDTA-T gel presented a better smear layer removal than the control group (p < 0.01); no statistically significant differences were observed between the EDTA and EDTA-T groups and between the concentrations tested (Mann-Whitney, p > 0.05). Within the limits of this study, it can be concluded that all treatment modalities effectively removed the smear layer from the root surface. The addition of texapon into the EDTA gel formulation did not increase its effectiveness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the effectiveness of the clinical use of the gallium-aluminum-arsenium (GaAlAs) laser at the maximum and minimum energies recommended by the manufacturer for the treatment of dentine hypersensitivity. Background Data: Dentine hypersensitivity (DH) is a response to a stimulus that would not usually cause pain in a healthy tooth. It is characterized by sharp pain of short duration from the denuded dentin. Its etiology is unknown. The dentin only begins to show sensitivity when exposed to the buccal environment. This exposure can result after removal of the enamel and/or dental cement, or after root denudation. Different treatments are proposed for this disorder. Materials and Methods: In this study, 25 patients, with a total number of 106 cases of DH, were treated with GaAlAs low-level laser therapy (LLLT). 65% of the teeth were premolars; 14% were incisors and molars; 6.6% were canines. The teeth were irradiated with 3 and 5 J/cm 2 for up to six sessions, with an interval of 72 h between each application, and they were evaluated initially, after each application, and at 15 and 60 days follow-up post-treatment. Results: The treatment was effective in 86.53% and 88.88% of the irradiated teeth, respectively, with the minimum and maximum energy recommended by the manufacturer. There was a statistically significant difference between DH and after a follow-up of 60 days for both groups. The difference among the energy maximum and minimum was not significant. Conclusion: The GaAlAs low-level laser was effective in reducing initial DH. A significant difference was found between initial values of hypersensitivity and after 60 days follow-up post-treatment. No significant difference was found between minimum (3 J/cm 2) and maximum (5 J/cm 2) applied energy.