980 resultados para Power factor corrector
Resumo:
During the latest few years the need for new motor types has grown, since both high efficiency and an accurate dynamic performance are demanded in industrial applications. For this reason, new effective control systems such as direct torque control (DTC) have been developed. Permanent magnet synchronous motors (PMSM) are well suitable for new adjustable speed AC inverter drives, because their efficiency and power factor are not depending on the pole pair number and speed to the same extent as it is the case in induction motors. Therefore, an induction motor (IM) with a mechanical gearbox can often be replaced with a direct PM motor drive. Space as well as costs will be saved, because the efficiency increases and the cost of maintenance decreases as well. This thesis deals with design criterion, analytical calculation and analysis of the permanent magnet synchronous motor for both sinusoidal air-gap flux density and rectangular air-gapflux density. It is examined how the air-gap flux, flux densities, inductances and torque can be estimated analytically for salient pole and non-salient pole motors. It has been sought by means of analytical calculations for the ultimate construction for machines rotating at relative low 300 rpm to 600 rpm speeds, which are suitable speeds e.g. in Pulp&Paper industry. The calculations are verified by using Finite Element calculations and by measuring of prototype motor. The prototype motor is a 45 kW, 600 rpm PMSM with buried V-magnets, which is a very appropriate construction for high torque motors with a high performance. With the purposebuilt prototype machine it is possible not only to verify the analytical calculations but also to show whether the 600 rpm PMSM can replace the 1500 rpm IM with a gear. It can also be tested if the outer dimensions of the PMSM may be the same as for the IM and if the PMSM in this case can produce a 2.5 fold torque, in consequence of which it may be possible to achieve the same power. The thesis also considers the question how to design a permanent magnet synchronous motor for relatively low speed applications that require a high motor torqueand efficiency as well as bearable costs of permanent magnet materials. It is shown how a selection of different parameters affects the motor properties. Key words: Permanent magnet synchronous motor, PMSM, surface magnets, buried magnets
Resumo:
Design aspects of the Transversally Laminated Anisotropic (TLA) Synchronous Reluctance Motor (SynRM) are studied and the machine performance analysis compared to the Induction Motor (IM) is done. The SynRM rotor structure is designed and manufactured for a30 kW, four-pole, three-phase squirrel cage induction motor stator. Both the IMand SynRM were supplied by a sensorless Direct Torque Controlled (DTC) variablespeed drive. Attention is also paid to the estimation of the power range where the SynRM may compete successfully with a same size induction motor. A technicalloss reduction comparison between the IM and SynRM in variable speed drives is done. The Finite Element Method (FEM) is used to analyse the number, location and width of flux barriers used in a multiple segment rotor. It is sought for a high saliency ratio and a high torque of the motor. It is given a comparison between different FEM calculations to analyse SynRM performance. The possibility to take into account the effect of iron losses with FEM is studied. Comparison between the calculated and measured values shows that the design methods are reliable. A new application of the IEEE 112 measurement method is developed and used especially for determination of stray load losses in laboratory measurements. The study shows that, with some special measures, the efficiency of the TLA SynRM is equivalent to that of a high efficiency IM. The power factor of the SynRM at rated load is smaller than that of the IM. However, at lower partial load this difference decreases and this, probably, brings that the SynRM gets a better power factor in comparison with the IM. The big rotor inductance ratio of the SynRM allows a good estimating of the rotor position. This appears to be very advantageous for the designing of the rotor position sensor-less motor drive. In using the FEM designed multi-layer transversally laminated rotor with damper windings it is possible to design a directly network driven motor without degrading the motorefficiency or power factor compared to the performance of the IM.
Resumo:
High dynamic performance of an electric motor is a fundamental prerequisite in motion control applications, also known as servo drives. Recent developments in the field of microprocessors and power electronics have enabled faster and faster movements with an electric motor. In such a dynamically demanding application, the dimensioning of the motor differs substantially from the industrial motor design, where feasible characteristics of the motor are for example high efficiency, a high power factor, and a low price. In motion control instead, such characteristics as high overloading capability, high-speed operation, high torque density and low inertia are required. The thesis investigates how the dimensioning of a high-performance servomotor differs from the dimensioning of industrial motors. The two most common servomotor types are examined; an induction motor and apermanent magnet synchronous motor. The suitability of these two motor types indynamically demanding servo applications is assessed, and the design aspects that optimize the servo characteristics of the motors are analyzed. Operating characteristics of a high performance motor are studied, and some methods for improvements are suggested. The main focus is on the induction machine, which is frequently compared to the permanent magnet synchronous motor. A 4 kW prototype induction motor was designed and manufactured for the verification of the simulation results in the laboratory conditions. Also a dynamic simulation model for estimating the thermal behaviour of the induction motor in servo applications was constructed. The accuracy of the model was improved by coupling it with the electromagnetic motor model in order to take into account the variations in the motor electromagnetic characteristics due to the temperature rise.
Resumo:
Työssä vertaillaan massatuotannon näkökulmasta eri tehoalueille sopivia teholähteen toteuttamisvaihtoehtoja. Lisäksi esitellään standardien asettamia vaatimuksia teholähteille. Työssä käsitellään teholähdesuunnittelun eri osa-alueita ja niihin sopivien simulointityökalujen hyödyntämismahdollisuuksia suunnitteluprosessin osana. Simulointituloksia ja teoreettisia laskelmia vertaillaan prototyypistä suoritettuihin mittauksiin.
Resumo:
Hyötysuhteen merkitys tehoelektroniikan järjestelmissä kasvaa jatkuvasti kun käytössä olevien järjestelmien määrä lisääntyy ja toisaalta energian hinta kallistuu. Hyötysuhteen lisäksi verkkovirran käyrämuotovaatimukset asettavat omat haasteensa sähköverkkoon liitettävien tehoelektroniikkajärjestelmien suunnittelulle. Tässä työssä tutkitaan häviöiden syntyyn vaikuttavia tekijöitä hakkuriteholähteissä ja pyritään löytämään keinoja hyötysuhteen parantamiseksi. Työssä analysoidaan 300 W – 2 kW tehoalueelle soveltuvat, tehokerroinkorjattujen AC/DC-hakkuriteholähteiden topologiavaihtoehdot ja arvioidaan niiden soveltuvuutta tavanomaisen boost-topologian korvaajaksi. Tarkastelussa otetaan huomioon kustannukset, toimivuus sekä saavutettu hyötysuhteen parantuminen verrattuna perinteisellä topologialla toteutettuun teholähteeseen. Tarkasteltavat topologiat valitaan kirjallisuustutkimuksen perusteella. Valittujen topologioiden häviöt ja hyötysuhde selvitetään analyyttisin menetelmin sekä simuloimalla. Käytännön testausta varten suunnitellaan ja rakennetaan prototyyppi valitusta topologiasta.
Resumo:
Verkon harmonisvirtoja rajoittavien standardien tiukentuessa joudutaan etenkin suuritehoisissa tehoelektronisissa laitteissa siirtymään aktiivisiin transistoriohjattuihin tasasuuntaajiin, jotka korjaavat tehokerrointa ja siten pienentävät verkkoon kytkeytyviä häiriövirtoja. Tässä diplomityössä esitellään yleisimpien kolmivaiheisten tasasuuntaajatopologioiden eroja ja vertaillaan puoliohjatun kolmikytkintopologian ja kuusikytkintopologian suorituskykyä tehokertoimen ja harmonissärön osalta, 16 kilowatin teholuokan taajuusmuuttajassa. Tasasuuntaajille tehtiin skalaariohjaukseen perustuva simulointimalli. Työn tavoitteena esitellään simulointitulokset harmonistason sekä tehokertoimen osalta. Työ liittyy Lappeenrannan teknillisen yliopiston sovelletun elektroniikan laboratorion ja Vacon Oyj:n yhteiseen hankkeeseen.
Resumo:
Led-valaisun kehitys on mahdollistanut sen käytön kodin yleisvalaistuksessa. Työssä tutkitaan eri led-valaisuun soveltuvia teholähteitä, joista valitaan teknisiltä ominaisuuksiltaan sopivin kodin yleiskäyttöön. Tutkittavia teholähteitä ovat lineaariset ja hakkuriteholähteet. Teholähteiden ominaisuuksista tarkastellaan hyötysuhteita ja tehokertoimia, joista molempien perusteella sopivin teholähdetyyppi valitaan.
Resumo:
This bachelor’s thesis is a part of the research project realized in the summer 2011 in Lappeenranta University of Technology. The goal of the project was to develop an automation concept for controlling the electrically excited synchronous motor. Thesis concentrates on the implementation of the automation concept into the ABB’s AC500 programmable logic enviroment. The automation program was developed as a state machine with the ABB’s PS501 Control Builder software. For controlling the automation program is developed a fieldbus control and with CodeSys Visualization Tool a local control with control panel. The fieldbus control is done to correspond the ABB drives communication profile and the local control is implemented with a function block which feeds right control words into the statemachine. A field current control of the synchronous motor is realized as a method presented in doctoral thesis of Olli Pyrhönen (Pyrhönen 1998). The Method combines stator flux and torque based openloop control and power factor based feedback control.
Resumo:
Talotekniikan alalla valaistusmuutoksissa LED-valaistus on nykypäivää. Valaistuksen käyttöominaisuudet ja hyödyt tekevät siitä perustellun valinnan myös suurissa kohteissa. Näistä laajemmista valaistuksen muutoksista ja niiden vaikutuksista sähkön laatuun ei ole yleisesti mittaustietoa. Tämä tutkimus perustui sähkön laadun käytännön mittauksiin valaistusmuutoksessa, jossa elohopeahöyrylampuilla toteutettu valaistus vaihdettiin LED-valaistukseen hypermarketin pysäköintihallissa. Valaistusjärjestelmän muutoksen vaikutusta sähkön laatuun tutkittiin vertailemalla mittaustuloksia vanhan ja uuden järjestelmän välillä. Tutkimuksen tarkoituksena oli osoittaa miten LED-valaistukseen siirtyminen vaikuttaa sähkön laatuun valitussa tutkimuskohteessa. Tutkimuksessa tuotettu tieto on hyödynnettävissä vastaavissa kohteissa LED-valaistukseen siirryttäessä sekä valaistuksen käyttöönoton suunnittelussa ja toteuttamisessa. Tutkimuksen tuloksia voidaan hyödyntää myös kustannusten arvioimisessa valaistavan tilan sähkönkulutuksen osalta. Tutkimus toteutettiin käyttämällä triangulaatiomenetelmää eli teemahaastattelulla, kirjallisuuskatsauksella ja käytännön mittauksilla. Näiden menetelmien tulokset tukivat tutkimukselle asetettuja hypoteeseja. Valitulla tutkimusmenetelmällä saatiin selville, että LED-valaistukseen siirtymisellä ei ollut heikentäviä vaikutuksia sähkön laatuun tutkitun kohteen valaistusjärjestelmässä. Toisaalta positiivisina vaikutuksina huomioitiin muun muassa merkittävä energian säästö, virran harmonisten häiriöiden väheneminen sekä kokonaistehokertoimen parantuminen.
Resumo:
Determinar la validez predictiva de la selectividad y la Enseñanza Secundaria sobre el rendimiento académico y la influencia moduladora de diferentes variables. 417 alumnos de las Universidades de Navarra y Zaragoza (342). VD: 1.- Media de rendimientos académicos, ponderada según convocatorias, durante el primer año académico; 2.- Media de las asignaturas superadas a lo largo de todos los estudios y 3.- Media ponderada según convocatorias, para todos los años de carrera (tres, cinco o seis años), multiplicada por el factor corrector C-T, donde 'C' es el número de asignaturas cursadas y 'T' el número de asignaturas que se deberían de haber cursado según el plan de estudios VI: Expediente secundario, examen de acceso, aptitudes mentales, rasgos de personalidad y madurez académica. Se calcula para cada una de las 101 variables los siguientes índices descriptivos: frecuencia total, media, desviación típica, rango, valor máximo y mínimo y coeficiente de variación. Análisis de correlación entre las variables correspondientes a los rendimientos académicos universitarios y los de las pruebas de acceso. Prueba Chi cuadrado para las variables nominales. Análisis de regresión lineal múltiple para determinar la validez predictiva de las variables. La selectividad y el examen de acceso tienen una escasa capacidad predictiva sobre el rendimiento a lo largo de todos los estudios. La prueba de acceso en conjunto, presenta unas correlaciones con los rendimientos académicos Universitarios idénticos a los que ofrece el expendiente secundario por sí solo. En general, las distintas ecuaciones obtenidas a partir de diferentes variables tienen para la muestra total una capacidad predictiva baja. Se deduce que para una mejor predicción del rendimiento académico Universitario es necesario plantearse una selección específica por tipo de estudios y con procedimientos específicos, aunque se tenga que apoyar en todos los casos en variables de madurez y preparación académicas previas.
Resumo:
Chemical substitution in Co3Sn2-xInxS2 (0 # x # 2) enables tuning of the Fermi level within narrow bands of Co d-states. This results in a compositionally induced double metal–semiconductor–metal transition and manipulation of the thermoelectric power factor. The maximum power factor (14 mW cm-1 K-2) is found for x ¼ 0.85, which corresponds to ZT z 0.2 at 300 K.
Resumo:
The effect of Pb2+ doping on the structure and thermoelectric properties of BiOCuSe (also known as BiCuSeO or BiCuOSe) is described. With increasing Pb2+ content, the expansion of the unit cell results in a weakening of the bonding between the [Bi2(1-x) Pb2xO2]2(1-x)+ and the [Cu2Se2]2(1-x)- layers. The electrical resistivity and Seebeck coefficient decrease in a systematic way with growing Pb2+ levels. The thermal conductivity rises due to the increase of the electronic contribution with doping. The power factor of materials with a 4-5% Pb2+ content takes values of ca. 8 W cm-1 K-2 over a wide temperature range. ZT at 673 K is enhanced by ca. 50% when compared to values found for other dopants, such as Sr2+ or Mg2+.
Resumo:
Low-frequency noise in an electrolyte-insulator- semiconductor (EIS) structure functionalized with multilayers of polyamidoamine (PAMAM) dendrimer and single-walled carbon nanotubes (SWNT) is studied. The noise spectral density exhibits 1/f(gamma) dependence with the power factor of gamma approximate to 0.8 and gamma = 0.8-1.8 for the bare and functionalized EIS sensor, respectively. The gate-voltage noise spectral density is practically independent of the pH value of the solution and increases with increasing gate voltage or gate-leakage current. It has been revealed that functionalization of an EIS structure with a PAMAM/SWNTs multilayer leads to an essential reduction of the 1/f noise. To interpret the noise behavior in bare and functionalized EIS devices, a gate-current noise model for capacitive EIS structures based on an equivalent flatband-voltage fluctuation concept has been developed.
Resumo:
This study presents a description of the development model of a representation of simplified grid applied in hybrid load flow for calculation of the voltage variations in a steady-state caused by the wind farm on power system. Also, it proposes an optimal load-flow able to control power factor on connection bar and to minimize the loss. The analysis process on system, led by the wind producer, it has as base given technician supplied by the grid. So, the propose model to the simplification of the grid that allows the necessity of some knowledge only about the data referring the internal network, that is, the part of the network that interests in the analysis. In this way, it is intended to supply forms for the auxiliary in the systematization of the relations between the sector agents. The model for simplified network proposed identifies the internal network, external network and the buses of boulders from a study of vulnerability of the network, attributing them floating liquid powers attributing slack models. It was opted to apply the presented model in Newton-Raphson and a hybrid load flow, composed by The Gauss-Seidel method Zbarra and Summation Power. Finally, presents the results obtained to a developed computational environment of SCILAB and FORTRAN, with their respective analysis and conclusion, comparing them with the ANAREDE
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP