972 resultados para Power Distance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the performance of distance relays when applied to transmission system equipped with shunt FACTS device, Static Synchronous Compensator (STATCOM) is described. The aim of the proposed study is to evaluate the performance of distance relays when STATCOM is incorporated at the mid point of transmission lines for voltage control. A detailed model of STATCOM and its control strategy is presented. The presence of these devices significantly affects apparent impedance seen by the distance relays due to their rapid response to different power system configurations. The distance relay is evaluated for different loading conditions and for different fault locations. The faults are created during various pre-fault loading conditions. The studies are performed on 400KV and 132KV systems and the results are presented. Simulation studies are carried out using transient simulation software, PSCAD/EMTDC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider a dense, ad hoc wireless network confined to a small region, such that direct communication is possible between any pair of nodes. The physical communication model is that a receiver decodes the signal from a single transmitter, while treating all other signals as interference. Data packets are sent between source-destination pairs by multihop relaying. We assume that nodes self-organise into a multihop network such that all hops are of length d meters, where d is a design parameter. There is a contention based multiaccess scheme, and it is assumed that every node always has data to send, either originated from it or a transit packet (saturation assumption). In this scenario, we seek to maximize a measure of the transport capacity of the network (measured in bit-meters per second) over power controls (in a fading environment) and over the hop distance d, subject to an average power constraint. We first argue that for a dense collection of nodes confined to a small region, single cell operation is efficient for single user decoding transceivers. Then, operating the dense ad hoc network (described above) as a single cell, we study the optimal hop length and power control that maximizes the transport capacity for a given network power constraint. More specifically, for a fading channel and for a fixed transmission time strategy (akin to the IEEE 802.11 TXOP), we find that there exists an intrinsic aggregate bit rate (Thetaopt bits per second, depending on the contention mechanism and the channel fading characteristics) carried by the network, when operating at the optimal hop length and power control. The optimal transport capacity is of the form dopt(Pmacrt) x Thetaopt with dopt scaling as Pmacrt 1 /eta, where Pmacrt is the available time average transmit power and eta is the path loss exponent. Under certain conditions on the fading distribution, we then pro- - vide a simple characterisation of the optimal operating point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper presents an adaptive Fourier filtering technique and a relaying scheme based on a combination of a digital band-pass filter along with a three-sample algorithm, for applications in high-speed numerical distance protection. To enhance the performance of above-mentioned technique, a high-speed fault detector has been used. MATLAB based simulation studies show that the adaptive Fourier filtering technique provides fast tripping for near faults and security for farther faults. The digital relaying scheme based on a combination of digital band-pass filter along with three-sample data window algorithm also provides accurate and high-speed detection of faults. The paper also proposes a high performance 16-bit fixed point DSP (Texas Instruments TMS320LF2407A) processor based hardware scheme suitable for implementation of the above techniques. To evaluate the performance of the proposed relaying scheme under steady state and transient conditions, PC based menu driven relay test procedures are developed using National Instruments LabVIEW software. The test signals are generated in real time using LabVIEW compatible analog output modules. The results obtained from the simulation studies as well as hardware implementations are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new static 3-step distance relay based on the principle of multi-input phase comparison is described in the paper. Design principles and typical discriminating and logic circuits are described for the new relaying system. The relaying system uses semiconductor circuits throughout and features high speed and good performance. The comparator model, which effects multi-input phase comparison, has been devised to provide reliable pickup for closein faults, and to achieve an improved polar characteristic in the complex- impedance plane, which fits around only the fault area of a transmission line. Operating time of the relay is less than 1 cycle for unbalanced faults, and less than a halfcycle for 3-phase faults. Protective circuits have also been added to detect power swing and to block tripping for a predetermined number of power-swing cycles. The operating characteristics of the relay, as expressed by accuracy/range charts, are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new hybrid comparison technique for transmission line protection, providing polar characteristics marked by sharp discontinuities, has been developed. The comparator models, described in block schematic form, accompany a steady state theoretical basis for comparison. Dynamic test results are indicated for a directional quadrilateral characteristic which closely corresponds to the probable fault area of a transmission line.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Static distance relays employing semiconductor devices as their active elements offer many advantages over the conventional electromagnetic and rectifier relays. The paper describes single-system and three-system static distance relays, which depend for their operation on the instantaneous-comparison or `block-spike¿ scheme. Design principles and typical discriminating and logic circuits are described for the new relaying equipment. The relaying circuitry has been devised for obtaining uniform performance on all kinds of faults, by the use of two phase detectors¿one for multiphase faults and one for earth faults. The phase detector for multiphase faults provides an improved polar characteristic in the complex-impedance plane, which fits only around the fault area of a transmission line. The other features of the relay are: reliable pickup for close-in faults, least susceptibility to maloperation under power-swing conditions, and reduction in cost and panel space required. The operating characteristics of the relays, as expressed by accuracy/range charts, are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effectiveness of series capacitors used with long distance transmission lines in improving system stability is analyzed. Compensation efficiency is defined as the effectiveness of series capacitors. The influence of various factors on compensation efficiency such as capacitor location, line length, and degree of series compensation is investigated. Proper use of shunt reactors with series capacitors, in addition to limiting power frequency over- voltages, increases the maximum power transfer. Analytical expressions are included to aid in the calculation of compensation efficiency for a few typical cases. Curves are also presented indicating the critical value of shunt Mvar required for various degrees of series compensation and line lengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, knowledge-based approach using Support Vector Machines (SVMs) are used for estimating the coordinated zonal settings of a distance relay. The approach depends on the detailed simulation studies of apparent impedance loci as seen by distance relay during disturbance, considering various operating conditions including fault resistance. In a distance relay, the impedance loci given at the relay location is obtained from extensive transient stability studies. SVMs are used as a pattern classifier for obtaining distance relay co-ordination. The scheme utilizes the apparent impedance values observed during a fault as inputs. An improved performance with the use of SVMs, keeping the reach when faced with different fault conditions as well as system power flow changes, are illustrated with an equivalent 265 bus system of a practical Indian Western Grid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is a lot of pressure on all the developed and second world countries to produce low emission power and distributed generation (DG) is found to be one of the most viable ways to achieve this. DG generally makes use of renewable energy sources like wind, micro turbines, photovoltaic, etc., which produce power with minimum green house gas emissions. While installing a DG it is important to define its size and optimal location enabling minimum network expansion and line losses. In this paper, a methodology to locate the optimal site for a DG installation, with the objective to minimize the net transmission losses, is presented. The methodology is based on the concept of relative electrical distance (RED) between the DG and the load points. This approach will help to identify the new DG location(s), without the necessity to conduct repeated power flows. To validate this methodology case studies are carried out on a 20 node, 66kV system, a part of Karnataka Transco and results are presented.