214 resultados para Pm10


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente - Sistemas Ambientais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação Apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil de Gestão e Sistemas Ambientais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To analyze the impact of air pollution on respiratory and cardiovascular morbidity of children and adults in the city of Vitoria, state of Espirito Santo. METHODS A study was carried out using time-series models via Poisson regression from hospitalization and pollutant data in Vitoria, ES, Southeastern Brazil, from 2001 to 2006. Fine particulate matter (PM10), sulfur dioxide (SO2), and ozone (O3) were tested as independent variables in simple and cumulative lags of up to five days. Temperature, humidity and variables indicating weekdays and city holidays were added as control variables in the models. RESULTS For each increment of 10 µg/m3 of the pollutants PM10, SO2, and O3, the percentage of relative risk (%RR) for hospitalizations due to total respiratory diseases increased 9.67 (95%CI 11.84-7.54), 6.98 (95%CI 9.98-4.17) and 1.93 (95%CI 2.95-0.93), respectively. We found %RR = 6.60 (95%CI 9.53-3.75), %RR = 5.19 (95%CI 9.01-1.5), and %RR = 3.68 (95%CI 5.07-2.31) for respiratory diseases in children under the age of five years for PM10, SO2, and O3, respectively. Cardiovascular diseases showed a significant relationship with O3, with %RR = 2.11 (95%CI 3.18-1.06). CONCLUSIONS Respiratory diseases presented a stronger and more consistent relationship with the pollutants researched in Vitoria. A better dose-response relationship was observed when using cumulative lags in polynomial distributed lag models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) mu m have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to contribute to the assessment of exposure levels of ultrafine particles (UFP) in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung-deposited alveolar surface area (resulting from exposure to UFP) in a major avenue leading to the town centre during late Spring, as well as in indoor buildings facing it. This study revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels could be directly related with the fluxes of automobile traffic. During a typical week, UFP alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and United States. The measured values allowed the determination of the number of UFP per cm(3), which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32-63%) outdoor, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 mu m2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Tecnologias de Protecção Ambiental

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objectivo principal deste trabalho é a realização de uma auditoria, à qualidade do ar interior (QAI), a um edifício de serviços – COCIGA, SA, tendo como base o Regulamento dos Sistemas Energéticos de Climatização dos Edifícios (RSECE). A auditoria QAI implica a medição de vários parâmetros físicos, químicos, microbiológicos e também a inspecção aos componentes do sistema de climatização com a finalidade de averiguar o seu estado de limpeza e manutenção. Assim, foram seleccionados 3 espaços, para a realização de amostragens designados por Comercial - Produtos, AVAC e Mezaninne das oficinas, nos quais foi efectuada a medição de diversos parâmetros, de acordo com as imposições do RSECE, utilizando medidores portáteis ou recorrendo a métodos analíticos. Relativamente aos parâmetros físicos, registaram-se valores de temperatura, para os três espaços estudados, entre os 21 e os 24 ºC e valores médios de humidade relativa de cerca de 50 %. Outro parâmetro medido, e de grande importância para garantir o conforto dos ocupantes, foi a velocidade do ar nos postos de trabalho. De acordo com o RSECE este valor não deve ser superior a 0,2 m/s, o que se verificou em todos os pontos medidos. O último parâmetro físico medido foi a concentração de partículas (PM10) tendo-se obtido valores de cerca de 23 μg/m3ar, valor bastante inferior ao máximo permitido pelo RSECE (150 μg/m3ar). Também no que diz respeito aos parâmetros químicos, ou seja, CO2, CO, formaldeído e ozono, não se verificaram valores superiores aos regulamentares. No caso do CO2, o valor máximo encontrado, nestes três espaços, foi de 745 ppm na Mezaninne das Oficinas e para o CO, na zona AVAC com uma concentração de 0,73 ppm. A medição do formaldeído registou valores perto dos 45 μg/m3ar e o ozono apenas foi detectado, em concentração muito reduzida, na zona Comercial – Produtos. Por fim, as concentrações de bactérias e fungos, de acordo com o RSECE, não devem ultrapassar as 500 UFC/m3ar (parâmetros microbiológicos). Em qualquer dos espaços, os valores medidos foram inferiores ao máximo legal, não ultrapassando as 50 UFC/m3ar. Da avaliação do projecto AVAC, e através da medição dos caudais de insuflação/ extracção em cada zona, concluiu-se que os seus valores não estão de acordo com os valores do projecto inicial que poderá ser imputada a uma insuficiência no funcionamento do sistema detectada na altura das medições. No que diz respeito ao estado de limpeza do sistema AVAC, apenas foi possível inspeccionar as unidades de tratamento de ar, tendo-se constatado que se encontram em boas condições. Ou seja, do ponto de vista do RSECE, e referindo-nos apenas à vertente da Qualidade do Ar Interior, o edifício em causa, cumpre todos os limites impostos para as concentrações de poluentes mas, apresenta algumas deficiências no que respeita aos caudais de ar novo insuflados em cada espaço.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m−3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m−3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to their detrimental effects on human health, the scientific interest in ultrafine particles (UFP) has been increasing, but available information is far from comprehensive. Compared to the remaining population, the elderly are potentially highly susceptible to the effects of outdoor air pollution. Thus, this study aimed to (1) determine the levels of outdoor pollutants in an urban area with emphasis on UFP concentrations and (2) estimate the respective dose rates of exposure for elderly populations. UFP were continuously measured over 3 weeks at 3 sites in north Portugal: 2 urban (U1 and U2) and 1 rural used as reference (R1). Meteorological parameters and outdoor pollutants including particulate matter (PM10), ozone (O3), nitric oxide (NO), and nitrogen dioxide (NO2) were also measured. The dose rates of inhalation exposure to UFP were estimated for three different elderly age categories: 64–70, 71–80, and >81 years. Over the sampling period levels of PM10, O3 and NO2 were in compliance with European legislation. Mean UFP were 1.7 × 104 and 1.2 × 104 particles/cm3 at U1 and U2, respectively, whereas at rural site levels were 20–70% lower (mean of 1 ×104 particles/cm3). Vehicular traffic and local emissions were the predominant identified sources of UFP at urban sites. In addition, results of correlation analysis showed that UFP were meteorologically dependent. Exposure dose rates were 1.2- to 1.4-fold higher at urban than reference sites with the highest levels noted for adults at 71–80 yr, attributed mainly to higher inhalation rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissertação teve como finalidade a realização de uma Auditoria Energética e da Qualidade do Ar Interior ao edifício de serviços da Câmara Municipal de Vila Nova de Gaia. No intuito de alcançar esta finalidade foram seguidos, em todo o processo, os regulamentos em vigor até à presente data da dissertação, de apoio à especialidade, nomeadamente o Regulamento das Características de Comportamento Térmico dos Edifícios, Regulamento dos Sistemas Energéticos de Climatização em Edifícios e Regulamento dos Sistemas Energéticos de Climatização em Edifícios e da Qualidade do Ar Interior. Na análise à Qualidade do Ar Interior foram verificados quase todos os parâmetros impostos por lei, exceto os das bactérias e dos fungos. Para as substâncias como dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCOH) e radão, os valores em média foram iguais a 894 ppm, 1,23 ppm, 0,07 ppm, 0,01 ppm e 378 Bq/m3 e estavam dentro dos limites regulamentares (984 ppm, 10,7ppm, 0,10 ppm, 0,08 ppm e 400 Bq/m3). Para os compostos orgânicos voláteis (COVs) e partículas do tipo PM10, os valores respetivos foram em média de 0,70 ppm e 0,16 mg/m3 e estavam acima dos limites regulamentares (0,26 ppm, 0,15 mg/m3). Admite-se que existem fontes emissoras de COVs dentro do edifício e que, para uma adequação ao tipo de tratamento ou sugestão de melhoria, seria necessário realizar uma análise por cromatografia de forma a identificar os compostos em causa. As concentrações de PM10 mais elevadas explicam-se porque existe uma abertura direta desses espaços ao exterior e em alguns casos esta é permanente. A análise energética permitiu um levantamento de todos os consumos de energia elétrica do edifício, realizando deste modo a desagregação em percentagem de cada equipamento consumidor. Em paralelo e até para se poder realizar a certificação energética do edifício foi realizado um estudo de simulação térmica dinâmica recorrendo ao programa DesignBuilder v2. Criou-se um modelo do edifício que foi validado após simulação e comparação com o consumo elétrico do ano de referência (desvio de 2,78%). Pela simulação verificou-se que os maiores consumidores de energia são a iluminação interior e o sistema de arrefecimento e determinou-se os Indicadores de Eficiência Energética (IEE) Real (com correção climática) e Nominal com valores de 73,8 e 46,5 , respetivamente. Implementando as condições nominais de utilização e funcionamento no edifício, segundo o Regulamento dos Sistemas Energéticos de vi Climatização em Edifícios (RSECE), concluiu-se que a classe energética deste edifício é do tipo D. O valor do IEE nominal foi superior ao IEE referência de 35,5 , e o requisito legal não se verificou. Assim, foi necessário apresentar medidas para um plano de racionalização energética (PRE). Nas medidas estudadas de melhoria da eficiência energética (aplicação de películas solares, compensação do fator de potência, instalação de um sistema de minigeração fotovoltaico e aplicação de iluminação eficiente tanto no interior como no exterior do edifício) destaca-se a correção do fator de potência, pois o valor pago de energia reactiva em 2011 foi de cerca de 1500 €. Admitindo ser necessário redimensionar os condensadores e que o custo é 1.840,00 €, ter-se-á um retorno do investimento em 1,2 anos. Outra medida é a aplicação de películas solares nos envidraçados com um custo de 5.046,00 €, esta terá um período de retorno de 1 ano e uma poupança de 37,90 MWh/ano. Finalmente refere-se a instalação de reguladores de tensão e substituição de determinadas lâmpadas por LEDs na iluminação interior, que prevê uma poupança anual de 25 MWh/ano e um período de retorno do investimento de 3,7 anos.