874 resultados para Percutaneous fracture fixation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background Acetabular fractures still are among the most challenging fractures to treat because of complex anatomy, involved surgical access to fracture sites and the relatively low incidence of these lesions. Proper evaluation and surgical planning is necessary to achieve anatomic reduction of the articular surface and stable fixation of the pelvic ring. The goal of this study was to test the feasibility of preoperative surgical planning in acetabular fractures using a new prototype planning tool based on an interactive virtual reality-style environment. Methods 7 patients (5 male and 2 female; median age 53 y (25 to 92 y)) with an acetabular fracture were prospectively included. Exclusion criterions were simple wall fractures, cases with anticipated surgical dislocation of the femoral head for joint debridement and accurate fracture reduction. According to the Letournel classification 4 cases had two column fractures, 2 cases had anterior column fractures and 1 case had a T-shaped fracture including a posterior wall fracture. The workflow included following steps: (1) Formation of a patient-specific bone model from preoperative computed tomography scans, (2) interactive virtual fracture reduction with visuo-haptic feedback, (3) virtual fracture fixation using common osteosynthesis implants and (4) measurement of implant position relative to landmarks. The surgeon manually contoured osteosynthesis plates preoperatively according to the virtually defined deformation. Screenshots including all measurements for the OR were available. The tool was validated comparing the preoperative planning and postoperative results by 3D-superimposition. Results Preoperative planning was feasible in all cases. In 6 of 7 cases superimposition of preoperative planning and postoperative follow-up CT showed a good to excellent correlation. In one case part of the procedure had to be changed due to impossibility of fracture reduction from an ilioinguinal approach. In 3 cases with osteopenic bone patient-specific prebent fixation plates were helpful in guiding fracture reduction. Additionally, anatomical landmark based measurements were helpful for intraoperative navigation. Conclusion The presented prototype planning tool for pelvic surgery was successfully integrated in a clinical workflow to improve patient-specific preoperative planning, giving visual and haptic information about the injury and allowing a patient-specific adaptation of osteosynthesis implants to the virtually reduced pelvis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Plates used for fracture fixation produce vascular injury to the underlying cortical bone. During the recovery of the blood supply, temporary osteoporosis is observed as a result of Haversian remodeling of the necrotic bone. This process temporarily reduces the strength of the bone. We tackled the postulate that quantitative differences exist between animal species, and in different bones within the same species, due to variations in the relative importance of the endosteal and periosteal blood supplies. Using implants scaled to the size of the bone, we found comparable cortical vascular damage in the sheep and in the dog, and in the tibia and femur of each animal. We observed a significant reduction in cortical vascular damage using plates that had a smaller contact area with the underlying bone. No significant difference in cortical vascular damage was noted in animals of different ages.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Methods: Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Findings: Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). Interpretation: These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

STUDY DESIGN Technical note and case series. OBJECTIVE To introduce an innovative minimal-invasive surgical procedure reducing surgery time and blood loss in management of U-shaped sacrum fractures. SUMMARY OF BACKGROUND Despite their seldom appearance, U-shaped fractures can cause severe neurological deficits and surgical management difficulties. According to the nature of the injury normally occurring in multi-injured patients after a fall from height, a jump, or road traffic accident, U-shaped fractures create a spinopelvic dissociation and hence are highly unstable. In the past, time-consuming open procedures like large posterior constructs or shortening osteotomies with or without decompression were the method of choice, sacrificing spinal mobility. Insufficient restoration of sacrococcygeal angle and pelvic incidence with conventional techniques may have adverse long-term effects in these patients. METHODS In a consecutive series of 3 patients, percutaneous reduction of the fracture with Schanz pins inserted in either the pedicles of L5 or the S1 body and the posterior superior iliac crest was achieved. The Schanz pins act as lever, allowing a good manipulation of the fracture. The reduction is secured by a temporary external fixator to permit optimal restoration of pelvic incidence and sacral kyphosis. Insertion of 2 transsacral screws allow fixation of the restored spinopelvic alignment. RESULTS Anatomic alignment of the sacrum was possible in each case. Surgery time ranged from 90 to 155 minutes and the blood loss was <50 mL in all 3 cases. Two patients had very good results in the long term regarding maintenance of pelvic incidence and sacrococcygeal angle. One patient with previous cauda equina decompression had loss of correction after 6 months. CONCLUSIONS Percutaneous reduction and transsacral screw fixation offers a less invasive method for treating U-shaped fractures. This can be advantageous in treatment of patients with multiple injuries.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Background: Percutaneous iliosacral screw placement following pelvic trauma is a very demanding technique involving a high rate of screw malpositions possibly associated with the risk of neurological damage or inadequate stability. In the conventional technique, the screw’s correct entry point and the small target corridor for the iliosacral screw may be difficult to visualise using an image intensifier. 2D and 3D navigation techniques may therefore be helpful tools. The aim of this multicentre study was to evaluate the intra- and postoperative complications after percutaneous screw implantation by classifying the fractures using data from a prospective pelvic trauma registry. The a priori hypothesis was that the navigation techniques have lower rates of intraoperative and postoperative complications. Methods: This study is based on data from the prospective pelvic trauma registry introduced by the German Society of Traumatology and the German Section of the AO/ASIF International in 1991. The registry provides data on all patients with pelvic fractures treated between July 2008 and June 2011 at any one of the 23 Level I trauma centres contributing to the registry. Results: A total of 2615 patients were identified. Out of these a further analysis was performed in 597 patients suffering injuries of the SI joint (187 � with surgical interventions) and 597 patients with sacral fractures (334 � with surgical interventions). The rate of intraoperative complications was not significantly different, with 10/114 patients undergoing navigated techniques (8.8%) and 14/239 patients in the conventional group (5.9%) for percutaneous screw implantation (p = 0.4242). Postoperative complications were analysed in 30/114 patients in the navigated group (26.3%) and in 70/239 patients (29.3%) in the conventional group (p = 0.6542). Patients who underwent no surgery had with 66/197 cases (33.5%) a relatively high rate of complications during their hospital stay. The rate of surgically-treated fractures was higher in the group with more unstable Type-C fractures, but the fracture classification had no significant influence on the rate of complications. Discussion: In this prospective multicentre study, the 2D/3D navigation techniques revealed similar results for the rate of intraoperative and postoperative complications compared to the conventional technique. The rate of neurological complications was significantly higher in the navigated group.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Over the past ten years, minimally invasive plate osteosynthesis (MIPO) for the fixation of long bone fractures has become a clinically accepted method with good outcomes, when compared to the conventional open surgical approach (open reduction internal fixation, ORIF). However, while MIPO offers some advantages over ORIF, it also has some significant drawbacks, such as a more demanding surgical technique and increased radiation exposure. No clinical or experimental study to date has shown a difference between the healing outcomes in fractures treated with the two surgical approaches. Therefore, a novel, standardised severe trauma model in sheep has been developed and validated in this project to examine the effect of the two surgical approaches on soft tissue and fracture healing. Twenty four sheep were subjected to severe soft tissue damage and a complex distal femur fracture. The fractures were initially stabilised with an external fixator. After five days of soft tissue recovery, internal fixation with a plate was applied, randomised to either MIPO or ORIF. Within the first fourteen days, the soft tissue damage was monitored locally with a compartment pressure sensor and systemically by blood tests. The fracture progress was assessed fortnightly by x-rays. The sheep were sacrificed in two groups after four and eight weeks, and CT scans and mechanical testing performed. Soft tissue monitoring showed significantly higher postoperative Creatine Kinase and Lactate Dehydrogenase values in the ORIF group compared to MIPO. After four weeks, the torsional stiffness was significantly higher in the MIPO group (p=0.018) compared to the ORIF group. The torsional strength also showed increased values for the MIPO technique (p=0.11). The measured total mineralised callus volumes were slightly higher in the ORIF group. However, a newly developed morphological callus bridging score showed significantly higher values for the MIPO technique (p=0.007), with a high correlation to the mechanical properties (R2=0.79). After eight weeks, the same trends continued, but without statistical significance. In summary, this clinically relevant study, using the newly developed severe trauma model in sheep, clearly demonstrates that the minimally invasive technique minimises additional soft tissue damage and improves fracture healing in the early stage compared to the open surgical approach method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The formation of new blood vessels is a prerequisite for bone healing. CYR61 (CCN1), an extracellular matrix-associated signaling protein, is a potent stimulator of angiogenesis and mesenchymal stem cell expansion and differentiation. A recent study showed that CYR61 is expressed during fracture healing and suggested that CYR61 plays a significant role in cartilage and bone formation. The hypothesis of the present study was that decreased fixation stability, which leads to a delay in healing, would lead to reduced CYR61 protein expression in fracture callus. The aim of the study was to quantitatively analyze CYR61 protein expression, vascularization, and tissue differentiation in the osteotomy gap and relate to the mechanical fixation stability during the course of healing. A mid-shaft osteotomy of the tibia was performed in two groups of sheep and stabilized with either a rigid or semirigid external fixator, each allowing different amounts of interfragmentary movement. The sheep were sacrificed at 2, 3, 6, and 9 weeks postoperatively. The tibiae were tested biomechanically and histological sections from the callus were analyzed immunohistochemically with regard to CYR61 protein expression and vascularization. Expression of CYR61 protein was upregulated at the early phase of fracture healing (2 weeks), decreasing over the healing time. Decreased fixation stability was associated with a reduced upregulation of the CYR61 protein expression and a reduced vascularization at 2 weeks leading to a slower healing. The maximum cartilage callus fraction in both groups was reached at 3 weeks. However, the semirigid fixator group showed a significantly lower CYR61 immunoreactivity in cartilage than the rigid fixator group at this time point. The fraction of cartilage in the semirigid fixator group was not replaced by bone as quickly as in the rigid fixator group leading to an inferior histological and mechanical callus quality at 6 weeks and therefore to a slower healing. The results supply further evidence that CYR61 may serve as an important regulator of bone healing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mechanical microenvironment at a fracture site could potentially influence the outcomes of bone fracture healing. It is known that, should the fixation construct be too stiff, or the gap between the fracture ends be too large, bones are less likely to heal. Flexible fixation or so-called “biological fixation” has been shown to encourage the formation of fracture callus, and therefore result in better healing outcomes. However, till date the nature of the relationship between the degree of mechanical stability provided by a flexible fixation and optimal healing fracture healing outcomes has not been fully understood. This paper presents a computational model that can predict healing out-comes from early stage healing data under various fixation configurations. The results of the simulations demonstrate that the change of mechanical microenvironment of fracture site resulting from the different fixation configurations is of importance for the healing outcomes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1 mm of displacement, no statistically significant difference was found. At 2 mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.