915 resultados para Paediatric fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three pathological fractures occurred secondary to osteolytic lesions of multiple myeloma. Two long bone fractures were each stabilised using interlocking nail fixation augmented with polymethyl meth acral ate bone cement. One vertebral fracture was stabilised using Steinmann pins and PMMA. Successful stabilisation, rapid return to function and improvement in quality of life occurred in all fractures. The patient survived approximately eight months on concurrent chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Morbidity information is easily available from medical records but its scope is limited to the population attended by the health services. Information on the prevalence of diseases requires community surveys, which are not always feasible. These two sources of information represent two alternative assessments of disease occurrence, namely demand morbidity and perceived morbidity. The present study was conceived so as to elicit a potential relationship between them so that the former could be used in the absence of the latter. METHODS: A community of 13,365 families on the outskirts of S. Paulo, Brazil, was studied during the period from 15/Nov/1994 to 15/Jan/1995. Data regarding children less than 5 years old were collected from a household survey and from the 2 basic health units in the area. Prevalence of diseases was ascertained from perceived morbidity and compared to estimates computed from demand morbidity. RESULTS: Data analysis distinguished 2 age groups, infants less than 1 year old and children 1 to less than 5. The most important groups of diseases were respiratory diseases, diarrhoea, skin problems and infectious & parasitical diseases. Basic health units presented a better coverage for infants. Though disease frequencies were not different within or outside these units, a better coverage was found for diarrhoea and infectious & parasitical diseases in the infant group, and for diarrhoea in the older age group. Equivalence between the two types of morbidity was found to be limited to the infant group and concerned only the best covered diseases. The odds of a disease being seen at the health service should be of at least 4:10 to ensure this equivalence. CONCLUSION: It was concluded that, provided that health service coverage is good, demand morbidity can be taken as a reliable estimate of community morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Captopril, an inhibitor of angiotensin converting enzyme (ACE), is used to treat medical conditions like hypertension and heart failure, and it is usually administered in tablet form for adults. Since this dosage form is not recommended for infants and children up to 6 years, hospital pharmacies have to prepare liquid formulations for oral administration of captopril. Traditionally, concentration of captopril used in the formulations is 1mg/ml. The problem is that captopril is prone to oxidation, and its stability in solution is affected by pH, concentration of captopril, the presence of oxygen or metal ions. The influence of different formulation ingredients on the properties of physical and chemical stability of captopril in liquid preparations has been evaluated. Main of the study: to evaluate the stability of captopril for 30 days when formulated in a 1 mg/ml suspension adjuvanted with citric acid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the prevalence and analyze risk factors associated to osteoporosis and low-trauma fracture in women. METHODS: Cross-sectional study including a total of 4,332 women older than 40 attending primary care services in the Greater São Paulo, Southeastern Brazil, between 2004 and 2007. Anthropometrical and gynecological data and information about lifestyle habits, previous fracture, medical history, food intake and physical activity were obtained through individual quantitative interviews. Low-trauma fracture was defined as that resulting from a fall from standing height or less in individuals 50 years or older. Multiple logistic regression models were designed having osteoporotic fracture and bone mineral density (BMD) as the dependent variables and all other parameters as the independent ones. The significance level was set at p<0.05. RESULTS: The prevalence of osteoporosis and osteoporotic fractures was 33% and 11.5%, respectively. The main risk factors associated with low bone mass were age (OR=1.07; 95% CI: 1.06;1.08), time since menopause (OR=2.16; 95% CI: 1.49;3.14), previous fracture (OR=2.62; 95% CI: 2.08;3.29) and current smoking (OR=1.45; 95% CI: 1.13;1.85). BMI (OR=0.88; 95% CI: 0.86;0.89), regular physical activity (OR=0.78; 95% CI: 0.65;0.94) and hormone replacement therapy (OR=0.43; 95% CI: 0.33;0.56) had a protective effect on bone mass. Risk factors significantly associated with osteoporotic fractures were age (OR=1.05; 95% CI: 1.04;1.06), time since menopause (OR=4.12; 95% CI: 1.79;9.48), familial history of hip fracture (OR=3.59; 95% CI: 2.88;4.47) and low BMD (OR=2.28; 95% CI: 1.85;2.82). CONCLUSIONS: Advanced age, menopause, low-trauma fracture and current smoking are major risk factors associated with low BMD and osteoporotic fracture. The clinical use of these parameters to identify women at higher risk for fractures might be a reasonable strategy to improve the management of osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.