159 resultados para PLL
Resumo:
Autofluorescent single polyelectrolyte microcapsules, exemplified by poly-L-lysine (PLL), have been prepared through glutaraldehyde-mediated covalent layer-by-layer (LbL) assembly and subsequent core removal. CaCO3 microparticles were used as template cores for the LbL deposition and removed by treatment of ethylenediamine tetraacetic acid disodium salt (EDTA). The prepared microcapsules, without conjugating an exterior fluorochrome, exhibited evenly distributed fluorescence.
Resumo:
Dextran sulfate (DS)/poly-L-lysine (PLL) microcapsules are fabricated by an in situ coacervation method using DS-doped CaCO3 microparticles as templates. Twinned superstructures or spherical CaCO3 microparticles are produced depending on DS concentration in the starting Solution. DS/PLL microcapsules with ellipsoidal or spherical outline are obtained after removal of templates in disodium ethylene diamine tetraacetate dehydrate (EDTA) without PLL. Their shell thickness and negative surface charges increase with the DS weight percentage in the templates. The surface potential of DS/PLL microcapsules.
Resumo:
RecA of Escherichia coli and its active nucleoprotein filaments with DNA are important for the genomic integrity and the genetic diversity. The formation of the DNA-RecA nucleoprotein filaments is a complex multiple-step process and can be affected by many factors. In this work, the effects of poly-L-lysine (PLL) on the DNA-RecA nucleoprotein filaments are investigated in vitro by agarose gel electrophoresis and atomic force microscopy (AFM). The observed morphologies vary with the concentration, the length, and the addition order of PLL. These distinctions provide information for the conformation change of DNA and the binding sites of RecA protein in the formation process of nucleoprotein filaments.
Resumo:
Graphene sheets functionalized covalently with biocompatible poly-L-lysine (PLL) were first synthesized in all alkaline solution. PLL-functionalized graphene is water-soluble and biocompatible, which makes it a novel material promising for biological applications. Graphene sheets played an important role as connectors to assemble these active amino groups Of Poly-L-lysine, which provided a very biocompatible. environment for further functionalization, such as attaching bioactive molecules. As an example, an amplified biosensor toward H2O2 based on linking peroxidase onto PLL-functionalized graphene was investigated.
Resumo:
An oxygen carrier was prepared by encapsulating carbonylated hemoglobin (CO-Hb) molecules into polypeptide vesicles made from poly(L-lysine)-block-poly(L-phenylalanine) (PLL-b-PPA) diblock copolymers in aqueous medium at pH 5.8. The encapsulation was confirmed by confocal laser scanning microscopy (CLSM). The morphology and size of the Vesicles were studied by field-emission scanning electron microscopy (ESEM). They had a spherical shape with it mean diameter of about 4 to 5 mu m. The encapsulation efficiency of hemoglobin was 40 wt %, and the hemoglobin content in the vesicles was 32 wt %. The CO-Hb encapsulated in the PLL-b-PPA vesicles was more stable than free CO-Hb under ambient conditions, In the presence of a O-2 atmosphere, the CO-Hb in the vesicle could be converted into oxygen-binding hemoglobin (O-2-Hb) under irradiation of visible light for 2 h. Therefore, the CO-Hb/PLL-b-PPA vesicles are expected to be used its red blood cell substitutes.
Resumo:
A folate-conjugated copolymer PEG-PLA-PLL/folate was synthesized and mixed with pure PEG-PLA-PLL and a fluorescent model drug mFITC to prepare folate-conjugated micelles. The distribution of micelles was studied on cancer-cell-bearing mice via frozen slicing. The results show that mFITC is successfully encapsulated into folate(+) and folate(-)micelles; PEG-PLA-PLL micelles the latter can be internalized by both HeLa and CHO cells without selectivity due to their cationic surface charges, while folate(+)micelles exhibit more preferential endocytosis by HeLa cells than by CHO cells. The folate(-)micelles showed retention in both organs and tumors. The folate(+)micelles are a promising active targeting drug delivery system for FR over-expressing cells and they accumulate in tumor beds.
Resumo:
This report describes direct formation of giant vesicles from a series of poly(L-lysine)-block-poly(L-phenylalanine) (PLL-b-PPA) block copolymers from their water solution. These polymers are prepared by successive ring-opening polymerization (ROP) of the two alpha-amino acid N-carboxyanhydrides and then removing the side chain protecting groups by acidolysis. The structures of the copolymers are confirmed by nuclear magnetic resonance (NMR), differential scanning calorimetry (DSC), and size exclusion chromatography ( SEC). The vesicles are studied by atomic force microscopy (AFM), field emission scanning electron microscopy (ESEM), and confocal laser scanning microscopy (CLSM). Rhodamine B is used as a fluorescent probe to confirm the existence of the vesicle with an aqueous interior. The vesicle size is in the range 0.55-6 mu m, depending on the absolute and relative lengths of the two blocks, on initial polymer concentration, and on solution pH. The vesicles are still stable in water for 2 months after preparation. Addition of the copolymer to DNA solution results in complex formation with it. The complex assumes the morphology of irregular particles of less than 2 mu m. It is expected to be used in drug and gene delivery.
Resumo:
Polypeptide/polysaccharide graft copolymers poly(L-lysine)-graft-chitosan (PLL-g-Chi) were prepared by ring-opening polymerization (ROP) of epsilon-benzoxycarbonyl L-lysine N-carboxyanhydrides (Z-L-lysine NCA) in the presence of 6-O-triphenylmethyl chitosan. The PLL-g-Chi copolymers were thoroughly characterized by H-1 NMR, C-13 NMR, Fourier transform infrared (FT-IR), and gel permeation chromatography (GPC). The number-average degree of polymerization of PLL grafted onto the chitosan backbone could be adjusted by controlling the feed ratio of NCA to 6-O-triphenylmethyl chitosan. The particle size of the complexes formed from the copolymer and calf thymus DNA was measured by dynamic light scattering (DLS). It was found in the range of 120 similar to 340 nm. The gel retardation electrophoresis showed that the PLL-g-Chi copolymers possessed better plasmid DNA-binding ability than chitosan. The gene transfection effect in HEK 293T cells of the copolymers was evaluated, and the results showed that the gene transfection ability of the copolymer was better than that of chitosan and was dependent on the PLL grafting ratio. The PLL-g-Chi copolymers could be used as effective gene delivery vectors.
Resumo:
A novel biodegradable triblock copolymer poly(ethylene glycol)-b-poly(L-lactide)-b-poly(L-lysine) (PEG-PLA-PLL) was synthesized by acidolysis of poly(ethylene glycol)-b-poly(L-lactide)-b-poly(F-benzyloxycarbonyl-L-lysine) (PEG-PLA-PZLL) obtained by the ring-opening polymerization (ROP) of epsilon-benzyloxycarbonyl-L-lysine N-carboxyanhydride (ZLys NCA) with amino-terminated PEG-PLA-NH2 as a macro-initiator, and the pendant amino groups of the lysine residues were modified with a peptide known to modulate cellular functions, Gly-Arg-Gly-Asp-Ser-Tyr (GRGDSY, abbreviated as RGD) in the presence of 1,1'-carbonyldiimidazole (CDI). The structures of PEG-PLA-PLL/RGD and its precursors were confirmed by H-1 NMR, FT-IR, amino acid analysis and XPS analysis. The cell adhesion and cell spread on the PEG-PLA-PLL/RGD film were enhanced compared to those on pure PLA film. Therefore, the novel RGD-grafted triblock copolymer is promising for cell or tissue engineering applications. Both copolymers PEG-PLA-PZLL and PEG-PLA-PLL showed an amphiphilic nature and could self-assemble into micelles of homogeneous spherical morphology. The micelles were determined by fluorescence technique, dynamic light scattering (DLS), and field emission scanning electron microscopy (ESEM) and could be expected to find application in drug and gene delivery systems.
Resumo:
Phase-locked loops (PLLs) are a crucial component in modern communications systems. Comprising of a phase-detector, linear filter, and controllable oscillator, they are widely used in radio receivers to retrieve the information content from remote signals. As such, they are capable of signal demodulation, phase and carrier recovery, frequency synthesis, and clock synchronization. Continuous-time PLLs are a mature area of study, and have been covered in the literature since the early classical work by Viterbi [1] in the 1950s. With the rise of computing in recent decades, discrete-time digital PLLs (DPLLs) are a more recent discipline; most of the literature published dates from the 1990s onwards. Gardner [2] is a pioneer in this area. It is our aim in this work to address the difficulties encountered by Gardner [3] in his investigation of the DPLL output phase-jitter where additive noise to the input signal is combined with frequency quantization in the local oscillator. The model we use in our novel analysis of the system is also applicable to another of the cases looked at by Gardner, that is the DPLL with a delay element integrated in the loop. This gives us the opportunity to look at this system in more detail, our analysis providing some unique insights into the variance `dip' seen by Gardner in [3]. We initially provide background on the probability theory and stochastic processes. These branches of mathematics are the basis for the study of noisy analogue and digital PLLs. We give an overview of the classical analogue PLL theory as well as the background on both the digital PLL and circle map, referencing the model proposed by Teplinsky et al. [4, 5]. For our novel work, the case of the combined frequency quantization and noisy input from [3] is investigated first numerically, and then analytically as a Markov chain via its Chapman-Kolmogorov equation. The resulting delay equation for the steady-state jitter distribution is treated using two separate asymptotic analyses to obtain approximate solutions. It is shown how the variance obtained in each case matches well to the numerical results. Other properties of the output jitter, such as the mean, are also investigated. In this way, we arrive at a more complete understanding of the interaction between quantization and input noise in the first order DPLL than is possible using simulation alone. We also do an asymptotic analysis of a particular case of the noisy first-order DPLL with delay, previously investigated by Gardner [3]. We show a unique feature of the simulation results, namely the variance `dip' seen for certain levels of input noise, is explained by this analysis. Finally, we look at the second-order DPLL with additive noise, using numerical simulations to see the effects of low levels of noise on the limit cycles. We show how these effects are similar to those seen in the noise-free loop with non-zero initial conditions.
Resumo:
p.263-268
Resumo:
A method for producing a retrodirective (self-tracking) antenna, which can also be operated as a phased (selectively pointed) array through the addition of a simple switching circuit and DC bias offset adjustment, is presented. Phase adjustment to individual antenna elements is shown to be readily carried out by a simple frequency pushing technique, applied to a PLL circuit, thus replacing the requirement for additional phase shifters. Practical results when applied to a ten-element array operating at 2.4 GHz are shown for both modes of operation.
Resumo:
This paper describes the application of gene delivery vectors based on connecting together two well-defined low-generation poly(L-lysine) (PLL) dendrons using a disulfide-containing linker unit. We report that the transfection ability of these vectors in their own right is relatively low, because the low-generation number limits the endosomal buffering capacity. Importantly, however, we demonstrate that when applied in combination with Lipofectamine 2000 (TM), a vector from the cationic lipid family, these small cationic additives significantly enhance the levels of gene delivery (up to four-fold). Notably, the cationic additives have no effect on the levels of transfection observed with a cationic polymer, such as DEAE dextran. We therefore argue that the synergistic effects observed with Lipofectamine 2000 (TM) arise as a result of combining the delivery advantages of two different classes of vector within a single formulation, with our dendritic additives providing a degree of pH buffering within the endosome. As such, the data we present indicate that small dendritic structures, although previously largely overlooked for gene delivery owing to their inability to transfect in their own right, may actually be useful well-defined additives to well-established vector systems in order to enhance the gene delivery payload.
Resumo:
This letter presents a simple tracking phased locked loop (PLL) that can be used to track phase-modulated signals and provide a phase-conjugated signal for retrodirective retransmission. The configuration allows the retrodirective antenna to directly track phase-modulated signals with no requirement for a separate continuous wave (CW) pilot tone. The ability to directly track phase-modulated signals is carried out using a 4× multiplier on the tracking PLL reference signal. Practical phase conjugation results are presented for a five-element retrodirective array simultaneously sending and receiving phase-modulated (QPSK) signals. Signals with levels as low as -122 dBm can be phase-conjugated and retransmitted with 30 dBm EIRP.
Resumo:
In this paper results are presented for a simple yet highly sensitive transceiver for phase modulated RFID applications. This is an advance on other simple RFID readers which can only operate with amplitude shift keyed (ASK) signals. Simple circuitry is achieved by the use of a novel injection locked PLL configuration which replaces the standard superhet type architecture normally used. The transceiver is shown to operate with a number of phase modulation modes which have certain advantages relating to distance to target. The paper concludes with practical results obtained for the transceiver when operated within a backscatter RFID application. A unique advantage of this transceiver is its complete immunity to the problem of TX/RX isolation, allowing for long ranges, estimated to be in the region of 80m at 1 GHz, to be achieved even in the presence of a simple backscatter target.