991 resultados para Ortopedic prototype
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Until mid 2006, SCIAMACHY data processors for the operational retrieval of nitrogen dioxide (NO2) column data were based on the historical version 2 of the GOME Data Processor (GDP). On top of known problems inherent to GDP 2, ground-based validations of SCIAMACHY NO2 data revealed issues specific to SCIAMACHY, like a large cloud-dependent offset occurring at Northern latitudes. In 2006, the GDOAS prototype algorithm of the improved GDP version 4 was transferred to the off-line SCIAMACHY Ground Processor (SGP) version 3.0. In parallel, the calibration of SCIAMACHY radiometric data was upgraded. Before operational switch-on of SGP 3.0 and public release of upgraded SCIAMACHY NO2 data, we have investigated the accuracy of the algorithm transfer: (a) by checking the consistency of SGP 3.0 with prototype algorithms; and (b) by comparing SGP 3.0 NO2 data with ground-based observations reported by the WMO/GAW NDACC network of UV-visible DOAS/SAOZ spectrometers. This delta-validation study concludes that SGP 3.0 is a significant improvement with respect to the previous processor IPF 5.04. For three particular SCIAMACHY states, the study reveals unexplained features in the slant columns and air mass factors, although the quantitative impact on SGP 3.0 vertical columns is not significant.
Resumo:
Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.
Resumo:
A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Omega resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm(3). Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.
Resumo:
Subsurface drip irrigation that uses an emitter protection system to avoid its clogging by roots and soil particles may be viable compared to a conventional system. The objective of this work was to evaluate the performance of a system with emitter protection, and to compare the results with a system that uses a conventional emitter for subsurface drip irrigation. In the system with protection an inexpensive materials polyethylene hose, microtube, connector, and a dripper to control the flow rate were used; and, in the conventional system a commercial emitter was used. After 12 months of evaluation, the system with protector showed good performance, with relative average flow rate of 0.97 and 0.98 in pots with and without crop, respectively, showing no clogging problems and lower cost. In conventional system relative flow rate of 0.51 and 0.98 were observed in pots with and without crop, respectively, also clogging degree by roots of 49.22%, and emitters with soil inside was observed. Thus, the use of emitter with protection presented feasibility for subsurface drip irrigation, under conditions used in this research.
Resumo:
[ES] El Detector de Efectos Stroop (SED - Stroop Effect Detector), es una herramienta informática de asistencia, desarrollada a través del programa de investigación de Desarrollo Tecnológico Social de la Universidad de Las Palmas de Gran Canaria, que ayuda a profesionales del sector neuropsicológico a identificar problemas en la corteza orbitofrontal de un individuo, usándose para ello la técnica ideada por Schenker en 1998. Como base metodológica, se han utilizado los conocimientos adquiridos en las diferentes materias de la adaptación al grado en Ingeniería Informática como Gestión del Software, Arquitectura del Software y Desarrollo de Interfaces de Usuario así como conocimiento adquirido con anterioridad en asignaturas de Programación e Ingeniería del Software I y II. Como para realizar este proyecto sólo el conocimiento informático no era suficiente, he realizado una labor de investigación acerca del problema, teniendo que recopilar información de otros documentos científicos que abordan el tema, consultas a profesionales del sector como son el Doctor Don Ayoze Nauzet González Hernández, neurólogo del hospital Doctor Negrín de Las Palmas de Gran Canaria y el psicólogo Don José Manuel Rodríguez Pellejero que habló de este problema en clase del máster de Formación del Profesorado y que actualmente estoy cursando. Este trabajo presenta el test de Stroop con las dos versiones de Schenker: RCN (Reading Color Names) y NCW (Naming Colored Words). Como norma general, ambas pruebas presentan ante los sujetos estudios palabras (nombres de colores) escritas con la tinta de colores diferentes. De esta forma, el RCN consiste en leer la palabra escrita omitiendo la tonalidad de su fuente e intentando que no nos influya. Por el contrario, el NCW requiere enunciar el nombre del color de la tinta con la que está escrita la palabra sin que nos influya que ésta última sea el nombre de un color.
Resumo:
Technology advances in recent years have dramatically changed the way users exploit contents and services available on the Internet, by enforcing pervasive and mobile computing scenarios and enabling access to networked resources almost from everywhere, at anytime, and independently of the device in use. In addition, people increasingly require to customize their experience, by exploiting specific device capabilities and limitations, inherent features of the communication channel in use, and interaction paradigms that significantly differ from the traditional request/response one. So-called Ubiquitous Internet scenario calls for solutions that address many different challenges, such as device mobility, session management, content adaptation, context-awareness and the provisioning of multimodal interfaces. Moreover, new service opportunities demand simple and effective ways to integrate existing resources into new and value added applications, that can also undergo run-time modifications, according to ever-changing execution conditions. Despite service-oriented architectural models are gaining momentum to tame the increasing complexity of composing and orchestrating distributed and heterogeneous functionalities, existing solutions generally lack a unified approach and only provide support for specific Ubiquitous Internet aspects. Moreover, they usually target rather static scenarios and scarcely support the dynamic nature of pervasive access to Internet resources, that can make existing compositions soon become obsolete or inadequate, hence in need of reconfiguration. This thesis proposes a novel middleware approach to comprehensively deal with Ubiquitous Internet facets and assist in establishing innovative application scenarios. We claim that a truly viable ubiquity support infrastructure must neatly decouple distributed resources to integrate and push any kind of content-related logic outside its core layers, by keeping only management and coordination responsibilities. Furthermore, we promote an innovative, open, and dynamic resource composition model that allows to easily describe and enforce complex scenario requirements, and to suitably react to changes in the execution conditions.
Resumo:
Nella presente tesi è stato sviluppato un sistema di acquisizione automatico finalizzato allo studio del breast microwave imaging. Le misure sono state eseguite in configurazione monostatica, in cui viene acquisito un segnale da diverse posizioni lungo il perimetro dell’area di indagine. A questo scopo, è stato installato un motore ad alta precisione che permette la rotazione del fantoccio e l’esecuzione automatica delle misure da un numero di posizioni fissato. Per automatizzare il processo di acquisizione, è stato inoltre sviluppato appositamente un software in ambiente LabView. Successivamente, è stata eseguita una intensa sessione di misure finalizzate alla caratterizzazione del sistema sviluppato al variare delle condizioni di misura. Abbiamo quindi utilizzato dei fantocci di tumore di diverse dimensioni e permittività elettrica per studiare la sensibilità della strumentazione in condizione di mezzo omogeneo. Dall’analisi delle ricostruzioni multifrequenza effettuate tramite diversi algoritmi di tipo TR-MUSIC sul range di frequenze selezionato, abbiamo notato che il tumore è ricostruito correttamente in tutti gli scenari testati. Inoltre, abbiamo creato un ulteriore fantoccio per simulare la presenza di una disomogeneità nel dominio di imaging. In questo caso, abbiamo studiato le performances del sistema di acquisizione al variare della posizione del tumore, le cui caratteristiche sono state fissate, e della permittività associata al fantoccio. Dall’analisi dei risultati appare che le performances di ricostruzione sono condizionate dalla presenza della disomogeneità, in modo particolare se il tumore è posizionato all’interno di essa. Infine, abbiamo studiato delle performance di due algoritmi di ricostruzione 3D: uno di essi è basato sulla sovrappo- sizione tomografica e sfrutta metodi di interpolazione, l’altro si basa sull’utilizzo di un propagatore 3D per il dipolo Hertziano in approssimazione scalare.
Resumo:
Background: Visuoperceptual deficits in dementia are common and can reduce quality of life. Testing of visuoperceptual function is often confounded by impairments in other cognitive domains and motor dysfunction. We aimed to develop, pilot, and test a novel visuocognitive prototype test battery which addressed these issues, suitable for both clinical and functional imaging use. Methods: We recruited 23 participants (14 with dementia, 6 of whom had extrapyramidal motor features, and 9 age-matched controls). The novel Newcastle visual perception prototype battery (NEVIP-B-Prototype) included angle, color, face, motion and form perception tasks, and an adapted response system. It allows for individualized task difficulties. Participants were tested outside and inside the 3T functional magnetic resonance imaging (fMRI) scanner. Functional magnetic resonance imaging data were analyzed using SPM8. Results: All participants successfully completed the task inside and outside the scanner. Functional magnetic resonance imaging analysis showed activation regions corresponding well to the regional specializations of the visual association cortex. In both groups, there was significant activity in the ventral occipital-temporal region in the face and color tasks, whereas the motion task activated the V5 region. In the control group, the angle task activated the occipitoparietal cortex. Patients and controls showed similar levels of activation, except on the angle task for which occipitoparietal activation was lower in patients than controls. Conclusion: Distinct visuoperceptual functions can be tested in patients with dementia and extrapyramidal motor features when tests use individualized thresholds, adapted tasks, and specialized response systems.