904 resultados para Optimisation of methods
Resumo:
Data traffic caused by mobile advertising client software when it is communicating with the network server can be a pain point for many application developers who are considering advertising-funded application distribution, since the cost of the data transfer might scare their users away from using the applications. For the thesis project, a simulation environment was built to mimic the real client-server solution for measuring the data transfer over varying types of connections with different usage scenarios. For optimising data transfer, a few general-purpose compressors and XML-specific compressors were tried for compressing the XML data, and a few protocol optimisations were implemented. For optimising the cost, cache usage was improved and pre-loading was enhanced to use free connections to load the data. The data traffic structure and the various optimisations were analysed, and it was found that the cache usage and pre-loading should be enhanced and that the protocol should be changed, with report aggregation and compression using WBXML or gzip.
Resumo:
The preparation of 2', 3'-di-O-hexanoyluridine (2) by a Candida antarctica B lipase-catalysed alcoholysis of 2', 3', 5'-tri-O-hexanoyluridine (1) was optimised using an experimental design. At 25 ºC better experimental conditions allowed an increase in the yield of 2 from 80% to 96%. In addition to the yield improvement, the volume reaction could be diminished in a factor of 5 and the reaction time significantly shortened.
Resumo:
In vitro release of bioidentical hormones in four different liposomal transdermal emulsions (containing testosterone, progesterone, estradiol, or estradiol and estriol) was assessed. For this purpose, novel high-performance liquid chromatography methods were developed and validated in an eco-friendly manner and used to determine the in vitro release of such products. The methods were suitable for our intended goal, and the emulsions employed were found to be effective as transporting candidates for the efficient release of hormones in the transdermal delivery of human sexual steroids.
Resumo:
In this work is proposed a solid phase preconcentration system of Co2+ ions and its posterior determination by GFAAS in which fractional factorial design and response surface methodology (RSM) were used for optimization of the variables associated with preconcentration system performance. The method is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam (PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and its determination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluent concentration and preconcentration and elution flow rates. Results obtained from fractional factorial design 2(5-1) showed that only the variables pH, buffer concentration and interaction (pH X buffer concentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidence level. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit of detection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10 µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and 2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations.
Resumo:
In this experiment, methods of total fecal collection (TFC) and internal markers (acid-insoluble ash - AIA, crude fiber - CF, and acid-detergent fiber - ADF) were compared for determination of the coefficients of apparent digestibility (CAD) for dry matter (DM), crude protein (CP), ether extract (EE), nitrogen-free extracts (NFE), and gross energy (GE) of commercial feline dry kibble for ocelots (Leopardus pardalis). Six adult animals, weighing 12.45±1.37 kg, gradually received experimental kibble in their usual diet until the beginning of the experiment and were submitted to an adaptation period ten days prior to the collection period. CAD obtained by TFC, AIA, CF, and ADF were, respectively, 73.7, 76.83, 62.01, and 46.03% for dry matter; 81.9, 84.8, 75.8, and 63.8% for crude protein; 85, 86.7, 78.5, and 69.1% for ether extract; 78.52, 79.55, 69.11, and 53.04% for nitrogen-free extracts; and 80.5, 82.2, 71.4, and 58.4% for gross energy. The AIA method showed to be efficient in determining coefficients of apparent digestibility and may contribute to investigations on the digestibility of diets for wild felines. In comparison to the items of ocelot's usual diet, the kibble used in this paper provided an adequate nutritional supply with reduced daily costs per animal.
Resumo:
This study focused on identifying various system boundaries and evaluating methods of estimating energy performance of biogas production. First, the output-input ratio method used for evaluating energy performance from the system boundaries was reviewed. Secondly, ways to assess the efficiency of biogas use and parasitic energy demand were investigated. Thirdly, an approach for comparing biogas production to other energy production methods was evaluated. Data from an existing biogas plant, located in Finland, was used for the evaluation of the methods. The results indicate that calculating and comparing the output-input ratios (Rpr1, Rpr2, Rut, Rpl and Rsy) can be used in evaluating the performance of biogas production system. In addition, the parasitic energy demand calculations (w) and the efficiency of utilizing produced biogas (η) provide detailed information on energy performance of the biogas plant. Furthermore, Rf and energy output in relation to total solid mass of feedstock (FO/TS) are useful in comparing biogas production with other energy recovery technologies. As a conclusion it is essential for the comparability of biogas plants that their energy performance would be calculated in a more consistent manner in the future.
Resumo:
We tested the correlation of the albumin-to-creatinine ratio (A/C) in an early-morning urine sample, measured with a commercial kit (DCA 2000®), with the conventional immunoturbidimetric determination in the laboratory and with overnight albumin excretion rate (reference method). Fifty-five type 1 diabetic adolescents had their first-morning urine collected on the 1st and 8th day of the period. Urinary albumin and creatinine were determined immediately using the DCA 2000® kit. Samples were also stored for laboratory analysis. To evaluate the correlation between early-morning urinary A/C ratio and overnight albumin excretion rate, 16 subjects had a timed overnight urine collection. A/C ratios determined with the DCA 2000® kit and by the laboratory method were 13.1 ± 20.5 and 20.4 ± 46.3 mg/g, respectively. A/C results by both methods proved to be strongly correlated (r = 0.98, P<0.001). DCA 2000®-determined A/C showed 50% sensitivity and 100% specificity when compared to the reference method. Spot urinary A/C of the subset of 16 subjects significantly correlated with their overnight albumin excretion rate (r = 0.98, P<0.001). Intraindividual variation ranged from 17 to 32% and from 9 to 63% for A/C and overnight albumin excretion rate, respectively. In conclusion, an early-morning specimen should be used instead of timed overnight urine and the A/C ratio is an accurate, reliable and easily determined parameter for the screening of diabetic nephropathy. Immediate measurement of the A/C ratio is feasible using the DCA 2000® kit. Intraindividual variability indicates the need for repeated determinations to confirm microalbuminuria and the diagnosis of incipient diabetic nephropathy.
Resumo:
Milk and egg matrixes were assayed for aflatoxin M1 (AFM1) and B1 (AFB1) respectively, by AOAC official and modified methods with detection and quantification by thin layer chromatography (TLC) and high performance thin layer chromatography (HPTLC). The modified methods: Blanc followed by Romer, showed to be most appropriate for AFM1 analysis in milk. Both methods reduced emulsion formation, produced cleaner extracts, no streaking spots, precision and accuracy improved, especially when quantification was performed by HPTLC. The use of ternary mixture in the Blanc Method was advantageous as the solvent could extract AFM1 directly from the first stage (extraction), leaving other compounds in the binary mixture layer, avoiding emulsion formation, thus reducing toxin loss. The relative standard deviation (RSD%) values were low, 16 and 7% when TLC and HPTLC were used, with a mean recovery of 94 and 97%, respectively. As far as egg matrix and final extract are concerned, both methods evaluated for AFB1 need further studies. Although that matrix leads to emulsion with consequent loss of toxin, the Romer modified presented a reasonable clean extract (mean recovery of 92 and 96% for TLC and HPTLC, respectively). Most of the methods studied did not performed as expected mainly due to the matrixes high content of triglicerides (rich on saturated fatty acids), cholesterol, carotene and proteins. Although nowadays most methodology for AFM1 is based on HPLC, TLC determination (Blanc and Romer modified) for AFM1 and AFB1 is particularly recommended to those, inexperienced in food and feed mycotoxins analysis and especially who cannot afford to purchase sophisticated (HPLC,HPTLC) instrumentation.
Resumo:
Most soybean pathogens are seed transmitted, deserving emphasis the fungus Sclerotinia sclerotiorum, which has been presenting worrying levels of field incidence in some soybean cropping areas in several Brazilian states. The objective of this study was to verify the efficiency of different methods for detecting S. sclerotiorum on soybean seeds artificially infected in the laboratory and from field production areas with a historical disease incidence. Seed samples of seven different cultivars collected from naturally infested fields, and one seed sample artificially inoculated in the laboratory were used. The following detection methods recommended in the literature were compared: Blotter test at 7 ºC, 14 ºC, and 21 ºC; Rolled Paper; and Neon-S. Results demonstrated that these methods showed no repeatability and had a low sensitivity for detecting the pathogen in seeds from areas with disease incidence. They were effective, however, for its detection on artificially inoculated seeds. In the Blotter test method at 7 ºC, there was a lower incidence of other fungi considered undesirable during seed analysis.
Resumo:
This study was undertaken in order to upgrade blends of HDPE and PP, two of the most widely used standard plastics so as to widen their application spectrum. Dicumyl peroxide was used as the modifier for the upgradation. Optimum concentration of dicumyl peroxide required for modification was detennined by measurement of mechanical, rheological, thermal and morphological properties. Selected blends were used to prepare recyclable composites with nylon clothes by compression moulding. The composites were characterized by measurement of mechanical and thermal properties. The composites were recycled and the mechanical propertics of the recycled material were determined.
Resumo:
Resumen tomado de la publicaci??n
Resumo:
This paper discusses a study to investigate the effectiveness of collagen splints for the enhancement of regeneration of the peripheral portion of the eighth nerve.