1000 resultados para Omics sciences


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The progress of the research activities on space material sciences, microgravity ‰uid physics and combustion, space life sciences and biotechnology research, fundamental Physics in China are brie‰y summarized in the present paper. The major space missions and experimental results obtained on board the Chinese recoverable/non-recoverable satellites and the Chinese manned spaceship named ``Shen-Zhou'' are presented summarily. The recent main activities of
the ground-based studies in China are introduced in brief.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper viewed the decline in information provision in Nigeria to poor library development, which could be attributed to poor funding. The consequence is that current journal and books are not available in nigerian fisheries libraries. Information which can be regarded as the first factor of production on which other factors like land, labour and capital depend, can only be provided at the right time when libraries are better founded. For now if there must be increase in fish production, poverty alleviation and food security in Nigeria, our fisheries scientists and policy makers will have to rely on international sources of information using the advantage of internet connectivity. Some of such sources discussed in this paper are ASFA, AGORA, FAO DOAJ, FISHBASE, IAMSLIC, INASP, INASP-PERI, INASP-AJOL, ODINAFRICA, SIFAR, WAS, and ABASFR. However, reliance on international sources must not be at the total neglect of harnessing nigerian fisheries information. For the Nigerian Fisheries and Aquatic Sciences Database being developed by NIFFR to attain an international status like those enumerated above, scientists and publishers are requested to take the pain of depositing copies of their publications with NIFFR for inclusion in the Database

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of 17 α-hydroxy-20 β-dihydroprogesterone (17 α-20 β Pg) or of a trout hypophyseal gonadotrophic extract on the in vitro intrafollicular maturation of trout oocytes can be modulated by steroids which do not have a direct maturing effect; the effectiveness of the gonadotrophic extract is lowered by oestradiol and oestrone and increased by testosterone. As these steroids have no significant effect on maturation induced by 17 α-20 β Pg, the site of their activity is probably in the follicular envelopes. Corticosteroids, and Cortisol and cortisone in particular increase the effectiveness of the gonadotrophic extract, but increase the effectiveness of 17 α-20 β Pg even more strongly, suggesting that this 'progestagen' has a direct effect on oocyte sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In accordance with the plan for joint Anglo-Soviet scientific and technical collaboration on environmental problems, the comparative evaluation of systems of hydrobiological analysis of the surface water quality started in 1977 at the Regional Laboratory of the Severn-Trent Water Authority in Nottingham were continued in the spring of 1978. The investigations were carried out under the auspices of the Institute of Hydrobiology of the Academy of Sciences of the Ukrainian SSR. Hydrobiological and hydrochemical samples were collected by Soviet and British specialists from the Kiev reservoir and the rivers Dnieper, Sozh, Desna and Snov. The samples were processed on the expedition ships and in the Laboratory for the Hydrobiology of Small Water Bodies of the Institute of Hydrobiology of the Academy of Sciences of the Ukrainian SSR. The possible approved methods to be adopted were evaluated from the samples using the phytoperiphyton, phytoplankton, zooplankton and zoobenthos against a background of hydrochemical characteristics. The study concludes that weather conditions complicated the work on testing the systems of biological indication of water quality and made it inadvisable to use those methods of comparison which were used when similar work was carried out in Nottingham.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report is divided into six sections, the first of which provides information on documents that emphasize the need for education/training of minorities in the sciences including marine science. Also provided is material students can use to find out about careers in the sciences, some universities that offer marine science education, and curricula that should be considered. The second section deals with existing programs designed to train pre-college students and prepare them either for further education or potential employment in the sciences. The next four sections deal with existing programs in the marine sciences for college-level students, scholarships and scholarship programs, examples of loan programs, and internships and internship programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The field of redox biology is inherently intertwined with oxidative stress biomarkers. Oxidative stress biomarkers have been utilized for many different objectives. Our analysis indicates that oxidative stress biomarkers have several salient applications: (1) diagnosing oxidative stress, (2) pinpointing likely redox components in a physiological or pathological process, and (3) estimating the severity, progression and/or regression of a disease. On the contrary, oxidative stress biomarkers do not report on redox signaling. Alternative approaches to gain more mechanistic insights are: (1) measuring molecules that are integrated in pathways linking redox biochemistry with physiology, (2) using the exomarker approach and (3) exploiting -omics techniques. More sophisticated approaches and large trials are needed to establish oxidative stress biomarkers in the clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In developing a biosensor, the utmost important aspects that need to be emphasized are the specificity and selectivity of the transducer. These two vital prerequisites are of paramount in ensuring a robust and reliable biosensor. Improvements in electrochemical sensors can be achieved by using microelectrodes and to modify the electrode surface (using chemical or biological recognition layers to improve the sensitivity and selectivity). The fabrication and characterisations of silicon-based and glass-based gold microelectrode arrays with various geometries (band and disc) and dimension (ranging from 10 μm-100 nm) were reported. It was found that silicon-based transducers of 10 μm gold microelectrode array exhibited the most stable and reproducible electrochemical measurements hence this dimension was selected for further study. Chemical electrodeposition on both 10 μm microband and microdisc were found viable by electro-assisted self-assembled sol-gel silica film and nanoporous-gold electrodeposition respectively. The fabrication and characterisations of on-chip electrochemical cell was also reported with a fixed diameter/width dimension and interspacing variation. With this regard, the 10 μm microelectrode array with interspacing distance of 100 μm exhibited the best electrochemical response. Surface functionalisations on single chip of planar gold macroelectrodes were also studied for the immobilisation of histidine-tagged protein and antibody. Imaging techniques such as atomic force microscopy, fluorescent microscopy or scanning electron microscope were employed to complement the electrochemical characterisations. The long-chain thiol of self-assembled monolayer with NTA-metal ligand coordination was selected for the histidine-tagged protein while silanisation technique was selected for the antibody immobilisation. The final part of the thesis described the development of a T-2 labelless immunosensor using impedimetric approach. Good antibody calibration curve was obtained for both 10 μm microband and 10 μm microdisc array. For the establishment of the T-2/HT-2 toxin calibration curve, it was found that larger microdisc array dimension was required to produce better calibration curve. The calibration curves established in buffer solution show that the microelectrode arrays were sensitive and able to detect levels of T-2/HT-2 toxin as low as 25 ppb (25 μg kg-1) with a limit of quantitation of 4.89 ppb for a 10 μm microband array and 1.53 ppb for the 40 μm microdisc array.