927 resultados para ONE-STEP PLUS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the pullout strength of a glass fiber-reinforced composite post (glass FRC) cemented with three different adhesive systems and one resin cement. The null hypothesis was that pullout strengths yielded by the adhesive systems are similar. Materials and Methods: Thirty bovine teeth were selected. The size of the specimens was standardized at 16 mm by sectioning off the coronal portion and part of the root. The specimens were divided into three groups, according to the adhesive system, which were applied following the manufacturers' instructions: G1, ScotchBond Multi-Purpose Plus; G2, Single Bond; G3, Tyrian SPE/One-Step Plus. The glass FRCs (Reforpost) were etched with 37% H3PO4 for 1 min and silanized (Porcelain Primer). Thereafter, they were cemented with the dual resin cement En-Force. The specimens were stored for 24 h, attached to an adapted device, and submitted to the pullout test in a universal testing machine (1 mm/min). The data were submitted to the one-way ANOVA and Tukey's test (α = 0.05). Results: G1 (30.2 ± 5.8 Kgf) displayed the highest pullout strength (p < 0.001) when compared to G2 (18.6 ± 5.8 Kgf) and G3 (14.3 ± 5.8 Kgf), which were statistically similar. Analysis of the specimens revealed that all failures occurred between the adhesive system and the root dentin (pullout of the post cement), regardless of group. Conclusion: The multiple-bottle, total-etch adhesive system provided higher pullout strength of the glass FRC when compared to the single-bottle, total-etch, and single-step self-etching adhesive systems. The null hypothesis was rejected (p < 0.001).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study evaluated the performance of different adhesive systems in fiber post placement aiming to clarify the influence of different hydrophobic experimental blend adhesives, and of one commercially available adhesive on the frictional retention during a luting procedure. Material and Methods: One luting agent (70 Wt% BisGMA, 28.5% TEGDMA; 1.5% p-tolyldiethanolamine) to cement fiber posts into root canals was applied with 4 different adhesive combinations: Group 1: The etched roots were rinsed with water for 30 s to remove the phosphoric acid, then rinsed with 99.6% ethanol for 30 s, and blot-dried. A trial adhesive (base to catalyst on a 1: 1 ratio) was used with an experimental luting agent (35% Bis-GMA, 14.37% TEGDMA, 0.5% EDMAB, 0.13% CQ); Group 2: A trial adhesive (base to catalyst on a 1: 2 ratio) was luted as in Group 1; Group 3: One-Step Plus (OSP, Bisco Inc.) following the ethanol bonding technique in combination with the luting agent as in Group 1; Group 4: OSP strictly following the manufacturer's instructions using the luting agent as in Group 1. The groups were challenged with push-out tests. Posted root slices were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under scanning electron microscopy. Results: Push-out strength was not significantly influenced by the luting agent (p>0.05). No statistically significant differences among the tested groups were found as Group 1 (Exp 1 - ethanol-wet bonding technique)=Group 2 (Exp 2 - ethanol-wet bonding technique)= Group 3 (OSP - ethanol-wet bonding technique)= Group 4 (control, OSP - water-wet bonding technique) (p>0.05). The dominating failure modes in all the groups were cohesive/adhesive failures, which were predominantly observed on the post/luting agent interface. Conclusions: The results of this study support the hypothesis that the proposal to replace water with ethanol to bond fiber posts to the root canal using highly hydrophobic resin is plausible, but this seems to be more the proof of a concept than a clinically applicable procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To evaluate the effects of 10% NaOCl gel application on the dentin bond strengths and morphology of resin-dentin interfaces formed by three adhesives. Methods: Two etch-and-rinse adhesives (One-Step Plus, Bisco Inc. and Clearfil Photo Bond, Kuraray Noritake Dental) and one self-etch adhesive (Clearfil SE Bond, Kuraray Noritake Dental) were applied on dentin according to the manufacturers’ instructions or after the treatment with 10% NaOCl (ED-Gel, Kuraray Noritake Dental) for 60 s. For interfacial analysis, specimens were subjected to acid-base challenge and observed by SEM to identify the formation of the acid-base resistant zone (ABRZ). For microtensile bond strength, the same groups were investigated and the restored teeth were thermocycled (5,000 cycles) or not before testing. Bond strength data were subjected to two-way ANOVA and Tukey’s test (p<0.05). Results: NaOCl application affected the bond strengths for One-Step Plus and Clearfil Photo Bond. Thermocycling reduced the bond strengths for Clearfil Photo Bond and Clearfil SE Bond when used after NaOCl application and One-Step Plus when used as recommended by manufacturer. ABRZ was observed adjacent to the hybrid layer for self-etch primer. The etch-and-rinse systems showed external lesions after acid-base challenge and no ABRZ formation when applied according to manufacturer’s instructions. Conclusions: 10% NaOCl changed the morphology of the bonding interfaces and its use with etch-&-rinse adhesives reduced the dentin bond strength. Formation of ABRZ was material-dependent and the interface morphologies were different among the tested materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the performance of All Bond SE used in a one- or two-step protocol in a 24-month randomized clinical study. Methods: Thirty-three patients with two similarly sized non-carious cervical lesions participated in this study. A total of 66 restorations were placed, half using the one-step All Bond SE protocol (SE-1) and the other half using the two-step All Bond SE protocol (SE-2). The restorations were evaluated at baseline and after 6, 12 and 24 months following the modified USPHS criteria and analyzed by the McNemar`s test and Fisher`s exact test (alpha=0.05). Results: After 24 months, six SE-1 and four SE-2 restorations were rated as Bravo in marginal discoloration The retention rates for SE-1 and SE-2 were 84.8% and 90.9%, respectively, after 24 months. Compared to baseline, the retention rate for SE-1 was statistically lower. Conclusions: All Bond SE used in the one- or two-step protocol resulted in high retention rates after 24 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Inaccurate species identification confounds insect ecological studies. Examining aspects of Trichogramma ecology pertinent to the novel insect resistance management strategy for future transgenic cotton, Gossypium hirsutum L., production in the Ord River Irrigation Area (ORIA) of Western Australia required accurate differentiation between morphologically similar Trichogramma species. Established molecular diagnostic methods for Trichogramma identification use species-specific sequence difference in the internal transcribed spacer (ITS)-2 chromosomal region; yet, difficulties arise discerning polymerase chain reaction (PCR) fragments of similar base pair length by gel electrophoresis. This necessitates the restriction enzyme digestion of PCR-amplified ITS-2 fragments to readily differentiate Trichogramma australicum Girault and Trichogramma pretiosum Riley. To overcome the time and expense associated with a two-step diagnostic procedure, we developed a “one-step” multiplex PCR technique using species-specific primers designed to the ITS-2 region. This approach allowed for a high-throughput analysis of samples as part of ongoing ecological studies examining Trichogramma biological control potential in the ORIA where these two species occur in sympatry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To evaluate in vitro the microshear bond strength of adhesive systems applied to dentin according to manufacturers` instructions, associated or not with a hydrophobic layer of unfilled resin. Materials and Methods: Six self-etching adhesives (Clearfil SE Bond, Kuraray Medical; AdheSE, lvoclar Vivadent; Xeno III, Dentsply; I Bond, Heraeus-Kulzer; Bond Force, Tokuyama; Futurabond DC, Voco) were tested. The labial dentin of sixty bovine incisors was exposed, and the teeth were divided into two groups according to the application or not of an extra hydrophobic resin layer (Scotchbond Multi Purpose Plus, bottle 3). Six composite cylinders (Filtek Z250, 3M ESPE) were built up on each treated surface. Specimens were stored in distilled water at 37 C for 24 h and then subjected to the microshear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. Microshear bond strength values were analyzed by 2-way ANOVA and Tukey`s post-hoc test. Failure mode was determined using a stereomicroscope under 20X magnification. Results: The application of the hydrophobic resin layer did not affect bond strength, except for AdheSE. However, the bond strengths with the hydrophobic layer were similar among the six tested systems (Clearfil: 17.1 +/- 7.9; AdheSE: 14.5 +/- 7.1; Xeno III: 12.8 +/- 7.7; I Bond: 9.5 +/- 5.8; Bond Force: 17.5 +/- 4.1; Futurabond: 7.7 +/- 2.3). When used as recommended by the manufacturers, Bond Force presented statistically higher bond strength than AdheSE and I Bond (p < 0.05) (Clearfil 10.4 +/- 4.9; AdheSE 1.6 +/- 1.6; Xeno III: 9.0 +/- 3.8; I Bond: 3.0 +/- 1.5; Bond Force: 14 +/- 3.9; Futurabond: 8.8 +/- 3.8). Failure mode was predominantly adhesive. Conclusion: The bond strength of the self-etching systems tested was not significantly affected by the application of a hydrophobic layer, but a significant improvement was observed in AdheSE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives. To evaluate the effects of storage condition (wet or dry) and storage time (24 h and 3 months) on the ultimate tensile strength (UTS) of Single Bond (SB), 3M-ESPE; Opti Bond Solo Plus (OB), Kerr; One Step (OS), Bisco, and Prime & Bond NT (PB), Dentsply adhesive resins. Methods. Hourglass-shaped specimens were obtained from a metallic matrix. Each adhesive was dispensed to fill the molds completely and left undisturbed in a dark chamber for 4 min at 37 degrees C for solvent evaporation. They were individually light-cured for 80 s at 500 mW/cm(2) and randomly divided into three groups: 24 h of water storage; 3 months of water storage; 3 months of dry storage. The specimens were tested in tension at 0.5 mm/min using the microtensile method and data were analyzed by two-way ANOVA and SNK tests for each material. Results. Water storage for 3 months did not cause significant changes in the UTS of any of the adhesives (p-value). Values for water storage ranged from 25.9 MPa for Single Bond at 24 h to 32.7 MPa for Prime & Bond NT after 3 months. Dry storage for 3 months yielded significantly higher UTS for most adhesives, which ranged from approximately 20% for Opti Bond to 160% higher values for Single Bond compared to their 3 months wet storage values. Conclusion. The effects of storage condition and time on the UTS of adhesives were material-dependent. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. To evaluate the effects of surface moisture (wet or dry) and storage (24h or 3 months) on the microtensile bond strength (BS) of resin/dentin bonds mediated by two water/ethanol based adhesives Single Bond, 3M-ESPE, (SB) and Opti Bond Solo Plus, Kerr, (OB), and two acetone-based adhesives, One Step, Bisco, (OS) and Prime&Bond NT, Caulk/Dentsply, (PB). Materials and methods. Flat dentin surfaces were polished with 600-grit SiC paper, etched with 35% phosphoric acid for 15 s and rinsed for 20 s. Half the surface was maintained moist and the other half was air-dried for 30 s. Each adhesive was applied simultaneously to both halves, left undisturbed for 30 s and light-cured. Four-mm resin build-ups were constructed incrementally. After storage in water at 37 degrees C for 24h, slabs were produced by transversal sectioning and trimmed to an hourglass shape (0.8 mm 2). Half of the specimens were tested in tension at 0.6 mm/min immediately after trimming and the other half after 3 months of water storage. Data were analyzed by two-way ANOVA and SNK for each material. Results. Both moisture and storage affected BS to dentin, and was material- dependent. Dry, bonding affected mostly the acetone-based adhesives. Larger reductions in bond strength were associated with dry bonding after 3 months of water storage. Significance. Wet bonding resulted in more stable bonds over 3 months of water storage for most of the materials tested. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose This 24-month randomized paired tooth clinical study evaluated the performance of All Bond 3 used in the simplified (2-step) and full (3-step) versions Methods 33 patients, with at least two similar sized non-carious cervical lesions participated in this study A total of 66 restorations were placed, half using the 2-step All Bond 3 (AB3-2) and the other half using 3-step All Bond 3 (AB3-3) The restorations were placed incrementally using the composite resin Aelite The restorations were evaluated at baseline and after 6, 12 and 24 months following the modified USPHS criteria Statistical differences between the adhesive were tested using with McNemar`s test and clinical performance over time for each material with the Fisher`s exact test (alpha= 0 05) Results After 24 months, six AB3-2 and four AB3-3 were rated as bravo for marginal discoloration but did not differ from each other significantly (P> 0 05) The retention rates at 24 months of AB3-2 and AB3-3 were 90 9% and 97 0%, respectively (P> 0 05) (Am J Dent 2010,23 231-236)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recent findings suggest an association between exposure to cleaning products and respiratory dysfunctions including asthma. However, little information is available about quantitative airborne exposures of professional cleaners to volatile organic compounds deriving from cleaning products. During the first phases of the study, a systematic review of cleaning products was performed. Safety data sheets were reviewed to assess the most frequently added volatile organic compounds. It was found that professional cleaning products are complex mixtures of different components (compounds in cleaning products: 3.5 ± 2.8), and more than 130 chemical substances listed in the safety data sheets were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%), skin (50%) and by ingestion (60%) were the most reported. Monoethanolamine, a strong irritant and known to be involved in sensitizing mechanisms as well as allergic reactions, is frequently added to cleaning products. Monoethanolamine determination in air has traditionally been difficult and air sampling and analysis methods available were little adapted for personal occupational air concentration assessments. A convenient method was developed with air sampling on impregnated glass fiber filters followed by one step desorption, gas chromatography and nitrogen phosphorous selective detection. An exposure assessment was conducted in the cleaning sector, to determine airborne concentrations of monoethanolamine, glycol ethers, and benzyl alcohol during different cleaning tasks performed by professional cleaning workers in different companies, and to determine background air concentrations of formaldehyde, a known indoor air contaminant. The occupational exposure study was carried out in 12 cleaning companies, and personal air samples were collected for monoethanolamine (n=68), glycol ethers (n=79), benzyl alcohol (n=15) and formaldehyde (n=45). All but ethylene glycol mono-n-butyl ether air concentrations measured were far below (<1/10) of the Swiss eight hours occupational exposure limits, except for butoxypropanol and benzyl alcohol, where no occupational exposure limits were available. Although only detected once, ethylene glycol mono-n-butyl ether air concentrations (n=4) were high (49.5 mg/m3 to 58.7 mg/m3), hovering at the Swiss occupational exposure limit (49 mg/m3). Background air concentrations showed no presence of monoethanolamine, while the glycol ethers were often present, and formaldehyde was universally detected. Exposures were influenced by the amount of monoethanolamine in the cleaning product, cross ventilation and spraying. The collected data was used to test an already existing exposure modeling tool during the last phases of the study. The exposure estimation of the so called Bayesian tool converged with the measured range of exposure the more air concentrations of measured exposure were added. This was best described by an inverse 2nd order equation. The results suggest that the Bayesian tool is not adapted to predict low exposures. The Bayesian tool should be tested also with other datasets describing higher exposures. Low exposures to different chemical sensitizers and irritants should be further investigated to better understand the development of respiratory disorders in cleaning workers. Prevention measures should especially focus on incorrect use of cleaning products, to avoid high air concentrations at the exposure limits. - De récentes études montrent l'existence d'un lien entre l'exposition aux produits de nettoyages et les maladies respiratoires telles que l'asthme. En revanche, encore peu d'informations sont disponibles concernant la quantité d'exposition des professionnels du secteur du nettoyage aux composants organiques volatiles provenant des produits qu'ils utilisent. Pendant la première phase de cette étude, un recueil systématique des produits professionnels utilisés dans le secteur du nettoyage a été effectué. Les fiches de données de sécurité de ces produits ont ensuite été analysées, afin de répertorier les composés organiques volatiles les plus souvent utilisés. Il a été mis en évidence que les produits de nettoyage professionnels sont des mélanges complexes de composants chimiques (composants chimiques dans les produits de nettoyage : 3.5 ± 2.8). Ainsi, plus de 130 substances listées dans les fiches de données de sécurité ont été retrouvées dans les 105 produits répertoriés. Les principales classes de substances chimiques identifiées étaient les parfums, les éthers de glycol, les agents de surface et les solvants; dans une moindre mesure, les phosphates, les sels, les détergents, les régulateurs de pH, les acides et les bases ont été identifiés. Plus de 75% des produits répertoriés contenaient des substances décrites comme irritantes (Xi), 64% nuisibles (Xn) et 28% corrosives (C). Les risques pour les yeux (59%), la peau (50%) et par ingestion (60%) était les plus mentionnés. La monoéthanolamine, un fort irritant connu pour être impliqué dans les mécanismes de sensibilisation tels que les réactions allergiques, est fréquemment ajouté aux produits de nettoyage. L'analyse de la monoéthanolamine dans l'air a été habituellement difficile et les échantillons d'air ainsi que les méthodes d'analyse déjà disponibles étaient peu adaptées à l'évaluation de la concentration individuelle d'air aux postes de travail. Une nouvelle méthode plus efficace a donc été développée en captant les échantillons d'air sur des filtres de fibre de verre imprégnés, suivi par une étape de désorption, puis une Chromatographie des gaz et enfin une détection sélective des composants d'azote. Une évaluation de l'exposition des professionnels a été réalisée dans le secteur du nettoyage afin de déterminer la concentration atmosphérique en monoéthanolamine, en éthers de glycol et en alcool benzylique au cours des différentes tâches de nettoyage effectuées par les professionnels du nettoyage dans différentes entreprises, ainsi que pour déterminer les concentrations atmosphériques de fond en formaldéhyde, un polluant de l'air intérieur bien connu. L'étude de l'exposition professionnelle a été effectuée dans 12 compagnies de nettoyage et les échantillons d'air individuels ont été collectés pour l'éthanolamine (n=68), les éthers de glycol (n=79), l'alcool benzylique (n=15) et le formaldéhyde (n=45). Toutes les substances mesurées dans l'air, excepté le 2-butoxyéthanol, étaient en-dessous (<1/10) de la valeur moyenne d'exposition aux postes de travail en Suisse (8 heures), excepté pour le butoxypropanol et l'alcool benzylique, pour lesquels aucune valeur limite d'exposition n'était disponible. Bien que détecté qu'une seule fois, les concentrations d'air de 2-butoxyéthanol (n=4) étaient élevées (49,5 mg/m3 à 58,7 mg/m3), se situant au-dessus de la frontière des valeurs limites d'exposition aux postes de travail en Suisse (49 mg/m3). Les concentrations d'air de fond n'ont montré aucune présence de monoéthanolamine, alors que les éthers de glycol étaient souvent présents et les formaldéhydes quasiment toujours détectés. L'exposition des professionnels a été influencée par la quantité de monoéthanolamine présente dans les produits de nettoyage utilisés, par la ventilation extérieure et par l'emploie de sprays. Durant la dernière phase de l'étude, les informations collectées ont été utilisées pour tester un outil de modélisation de l'exposition déjà existant, l'outil de Bayesian. L'estimation de l'exposition de cet outil convergeait avec l'exposition mesurée. Cela a été le mieux décrit par une équation du second degré inversée. Les résultats suggèrent que l'outil de Bayesian n'est pas adapté pour mettre en évidence les taux d'expositions faibles. Cet outil devrait également être testé avec d'autres ensembles de données décrivant des taux d'expositions plus élevés. L'exposition répétée à des substances chimiques ayant des propriétés irritatives et sensibilisantes devrait être investiguée d'avantage, afin de mieux comprendre l'apparition de maladies respiratoires chez les professionnels du nettoyage. Des mesures de prévention devraient tout particulièrement être orientées sur l'utilisation correcte des produits de nettoyage, afin d'éviter les concentrations d'air élevées se situant à la valeur limite d'exposition acceptée.