940 resultados para ONE-STEP
Resumo:
Biomarkers are nowadays essential tools to be one step ahead for fighting disease, enabling an enhanced focus on disease prevention and on the probability of its occurrence. Research in a multidisciplinary approach has been an important step towards the repeated discovery of new biomarkers. Biomarkers are defined as biochemical measurable indicators of the presence of disease or as indicators for monitoring disease progression. Currently, biomarkers have been used in several domains such as oncology, neurology, cardiovascular, inflammatory and respiratory disease, and several endocrinopathies. Bridging biomarkers in a One Health perspective has been proven useful in almost all of these domains. In oncology, humans and animals are found to be subject to the same environmental and genetic predisposing factors: examples include the existence of mutations in BR-CA1 gene predisposing to breast cancer, both in human and dogs, with increased prevalence in certain dog breeds and human ethnic groups. Also, breast feeding frequency and duration has been related to a decreased risk of breast cancer in women and bitches. When it comes to infectious diseases, this parallelism is prone to be even more important, for as much as 75% of all emerging diseases are believed to be zoonotic. Examples of successful use of biomarkers have been found in several zoonotic diseases such as Ebola, dengue, leptospirosis or West Nile virus infections. Acute Phase Proteins (APPs) have been used for quite some time as biomarkers of inflammatory conditions. These have been used in human health but also in the veterinary field such as in mastitis evaluation and PRRS (porcine respiratory and reproductive syndrome) diagnosis. Advantages rely on the fact that these biomarkers can be much easier to assess than other conventional disease diagnostic approaches (example: measured in easy to collect saliva samples). Another domain in which biomarkers have been essential is food safety: the possibility to measure exposure to chemical contaminants or other biohazards present in the food chain, which are sometimes analytical challenges due to their low bioavailability in body fluids, is nowadays a major breakthrough. Finally, biomarkers are considered the key to provide more personalized therapies, with more efficient outcomes and fewer side effects. This approach is expected to be the correct path to follow also in veterinary medicine, in the near future.
Resumo:
The aim was to describe the outcome of neonatal hearing screening (NHS) and audiological diagnosis in neonates in the NICU. The sample was divided into Group I: neonates who underwent NHS in one step and Group II: neonates who underwent a test and retest NHS. NHS procedure was automated auditory brainstem response. NHS was performed in 82.1% of surviving neonates. For GI, referral rate was 18.6% and false-positive was 62.2% (normal hearing in the diagnostic stage). In GII, with retest, referral rate dropped to 4.1% and false-positive to 12.5%. Sensorineural hearing loss was found in 13.2% of infants and conductive in 26.4% of cases. There was one case of auditory neuropathy spectrum (1.9%). Dropout rate in whole process was 21.7% for GI and 24.03% for GII. We concluded that it was not possible to perform universal NHS in the studied sample or, in many cases, to apply it within the first month of life. Retest reduced failure and false-positive rate and did not increase evasion, indicating that it is a recommendable step in NHS programs in the NICU. The incidence of hearing loss was 2.9%, considering sensorineural hearing loss (0.91%), conductive (1.83%) and auditory neuropathy spectrum (0.19%).
Resumo:
OBJECTIVE: To assess microleakage in conservative class V cavities prepared with aluminum-oxide air abrasion or turbine and restored with self-etching or etch-and-rinse adhesive systems. Materials and Methods: Forty premolars were randomly assigned to 4 groups (I and II: air abrasion; III and IV: turbine) and class V cavities were prepared on the buccal surfaces. Conditioning approaches were: groups I/III - 37% phosphoric acid; groups II/IV - self-priming etchant (Tyrian-SPE). Cavities were restored with One Step Plus/Filtek Z250. After finishing, specimens were thermocycled, immersed in 50% silver nitrate, and serially sectioned. Microleakage at the occlusal and cervical interfaces was measured in mm and calculated by a software. Data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS: Marginal seal provided by air abrasion was similar to high-speed handpiece, except for group I. There was SIGNIFICANT difference between enamel and dentin/cementum margins for to group I and II: air abrasion. The etch-and-rinse adhesive system promoted a better marginal seal. At enamel and dentin/cementum margins, the highest microleakage values were found in cavities treated with the self-etching adhesive system. At dentin/cementum margins, high-speed handpiece preparations associated with etch-and-rinse system provided the least dye penetration. CONCLUSION: Marginal seal of cavities prepared with aluminum-oxide air abrasion was different from that of conventionally prepared cavities, and the etch-and-rinse system promoted higher marginal seal at both enamel and dentin margins.
Resumo:
The purpose of the current study was to understand how visual information about an ongoing change in obstacle size is used during obstacle avoidance for both lead and trail limbs. Participants were required to walk in a dark room and to step over an obstacle edged with a special tape visible in the dark. The obstacle's dimensions were manipulated one step before obstacle clearance by increasing or decreasing its size. Two increasing and two decreasing obstacle conditions were combined with seven control static conditions. Results showed that information about the obstacle's size was acquired and used to modulate trail limb trajectory, but had no effect on lead limb trajectory. The adaptive step was influenced by the time available to acquire and process visual information. In conclusion, visual information about obstacle size acquired during lead limb crossing was used in a feedforward manner to modulate trail limb trajectory.
Resumo:
Potassium oxalate desensitizers were previously shown to effectively reduce the immediate permeability of resin-bonded dentin. The current study evaluated whether the effect of the combined application of oxalate with etch-and-rinse adhesives interferes with the durability of resin-dentin bonds when using etch-and-rinse adhesives. The bond strength of resin-bonded dentin specimens composed of two-step or three-step etch-and-rinse adhesives (Single Bond, One-Step and Scotchbond Multi-Purpose, respectively) was tested immediately (24 hours) and after 12 months of water storage. The adhesives were used either according to the manufacturers` instructions (control groups) or after treating acid-etched dentin with a potassium oxalate gel (BisBlock, BISCO, Inc). The treatment of dentin with potassium oxalate was shown to negatively affect the baseline bond strength of resin-bonded dentin specimens, regardless of the adhesive used (p<0.05). After storage, the bond strength of the resin-bonded interfaces was significantly reduced for all the tested groups (p<0.001). Nevertheless, the rate of decreasing bond strength was significantly lower for oxalate-treated specimens than for the controls (p<0.05).
Resumo:
Sugarcane bagasse hemicellulose was isolated in a one-step chemical extraction using hydrogen peroxide in alkaline media. The polysaccharide containing 80.9% xylose and small amounts of L-arabinose, 4-O-methyl-D-glucuronic acid and glucose, was hydrolyzed by crude enzymatic extracts from Thermoascus aurantiacus at 50 degrees C. Conditions of enzymatic hydrolysis leading to the best yields of xylose and xylooligosaccharides (DP 2-5) were investigated using substrate concentration in the range 0.5-3.5% (w/v), enzyme load 40-80 U/g of the substrate, and reaction time from 3 to 96 h, applying a 22 factorial design. The maximum conversion to xylooligosaccharides (37.1%) was obtained with 2.6% of substrate and xylanase load of 60 U/g. The predicted maximum yield of xylobiose by a polynomial model was 41.6%. Crude enzymatic extract of T. aurantiacus generate from sugarcane bagasse hemicellulose 39% of xylose, 59% of xylobiose, and 2% of other xylooligosaccharides.
Resumo:
A process has been elaborated for one-step low lignin content sugarcane bagasse hemicellulose extraction using alkaline solution of hydrogen peroxide. To maximize the hemicellulose yields several extraction conditions were examined applying the 2(4) factorial design: H(2)O(2) concentration from 2 to 6% (w/v), reaction time from 4 to 16 h, temperature from 20 to 60 degrees C, and magnesium sulfate absence or presence (0.5%, w/v). This approach allowed selection of conditions for the extraction of low and high lignin content hemicellulose. At midpoint the yield of hemicellulose was 94.5% with more than 88% of lignin removed. Lignin removal is suppressed at low extraction temperatures and in the absence of magnesium sulfate. Hemicellulose in 86% yield with low lignin content (5.9%) was obtained with 6% H(2)O(2) treatment for 4 h and 20 degrees C. This hemicellulose is much lighter in color than samples obtained at the midpoint condition and was found suitable for subsequent enzymatic hydrolysis. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
It has been observed experimentally [H.R. Xia, C.Y. Ye, and S.Y. Zhu, Phys. Rev. Lett. 77, 1032 (1996)] that quantum interference between two molecular transitions can lead to a suppression or enhancement of spontaneous emission. This is manifest in the fluorescent intensity as a function of the detuning of the driving field from the two-photon resonance condition. Here we present a theory that explains the observed variation of the number of peaks with the mutual polarization of the molecular transition dipole moments. Using master equation techniques we calculate analytically as well as numerically the steady-state fluorescence, and find that the number of peaks depends on the excitation process. If the molecule is driven to the upper levels by a two-photon process, the fluorescent intensity consists of two peaks regardless of the mutual polarization of the transition dipole moments. Lf the excitation process is composed of both a two-step, one-photon process and a one-step, two-photon process, then there are two peaks on transitions with parallel dipole moments and three peaks on transitions with antiparallel dipole moments. This latter case is in excellent agreement with the experiment.
Resumo:
Purification of recombinant human growth hormone (rhGH) from Chinese hamster ovary (CHO) cell culture supernatant by Gradiflow large-scale electrophoresis is described. Production of rhGH in CHO cells is an alternative to production in Escherichia coli, with the advantage that rhGH is secreted into protein-free production media, facilitating a more simple purification and avoiding resolubilization of inclusion bodies and protein refolding. As an alternative to conventional chromatography, rhGH was purified in a one-step procedure using Gradiflow technology. Clarified culture supernatant containing rhGH was passed through a Gradiflow BF200 and separations were performed over 60 min using three different buffers of varying pH. Using a 50 mM Tris/Hepes buffer at pH 7.5 together with a 50 kDa separation membrane, rhGH was purified to approximately 98% purity with a yield of 90%. This study demonstrates the ability of Gradiflow preparative electrophoresis technology to purify rhGH from mammalian cell culture supernatant in a one-step process with high purity and yield. As the Gradiflow is directly scalable, this study also illustrates the potential for the inclusion of the Gradiflow into bioprocesses for the production of clinical grade rhGH and other therapeutic proteins. (C) 2003 Elsevier Science (USA). All rights reserved.
Resumo:
Protein purification that combines the use of molecular mass exclusion membranes with electrophoresis is particularly powerful as it uses properties inherent to both techniques. The use of membranes allows efficient processing and is easily scaled up, while electrophoresis permits high resolution separation under mild conditions. The Gradiflow apparatus combines these two technologies as it uses polyacrylamide membranes to influence electrokinetic separations. The reflux electrophoresis process consists of a series of cycles incorporating a forward phase and a reverse phase. The forward phase involves collection of a target protein that passes through a separation membrane before trailing proteins in the same solution. The forward phase is repeated following clearance of the membrane in the reverse phase by reversing the current. We have devised a strategy to establish optimal reflux separation parameters, where membranes are chosen for a particular operating range and protein transfer is monitored at different pH values. In addition, forward and reverse phase times are determined during this process. Two examples of the reflux method are described. In the first case, we describe the purification strategy for proteins from a complex mixture which contains proteins of higher electrophoretic mobility than the target protein. This is a two-step procedure, where first proteins of higher mobility than the target protein are removed from the solution by a series of reflux cycles, so that the target protein remains as the leading fraction. In the second step the target protein is collected, as it has become the leading fraction of the remaining proteins. In the second example we report the development of a reflux strategy which allowed a rapid one-step preparative purification of a recombinant protein, expressed in Dictyostelium discoideum. These strategies demonstrate that the Gradiflow is amenable to a wide range of applications, as the protein of interest is not necessarily required to be the leading fraction in solution. (C) 1997 Elsevier Science B.V.
Resumo:
Introduction: Total knee arthroplasty (TKA) imposes many risks. TKA infection is not the most frequent complication, but is probably the most serious one. Two-step review is the procedure of choice in deep knee prosthesis infection. On the other hand, aseptic prosthesis detachment represents almost half of the primary arthroplasty review indications, Patient`s satisfaction level might diminish after reviews. Objective: The objective of this study was to compare the quality of life and final result of TKA review for septic and aseptic failures. Methods: The patients were assessed using the HSS and SF-36 scores. The patients were divided in two groups: one group submitted to two-step review (septic) and the other to one-step review (aseptic). The analysis of the data obtained shows better scores for the second group in HSS and in 06 of 08 domains of SF-36 classification. Conclusions: The on-step review of total knee arthroplasty leads to better functional outcomes.
Resumo:
We have previously isolated a Lys49 phospholipase A(2) homolog (BaTX) from Bothrops alternatus snake venom using a combination of molecular exclusion chromatography and reverse phase HPLC and shown its ability to cause neuromuscular blockade. In this work, we describe a one-step procedure for the purification of this toxin and provide further details of its neuromuscular activity. The toxin was purified by reverse phase HPLC and its purity and molecular mass were confirmed by SIDS-PAGE, MALDI-TOF mass spectrometry, amino acid analysis and N-terminal sequencing. BaTX (0.007-1.4 mu M) produced time-dependent, irreversible neuromuscular blockade in isolated mouse phrenic nerve-diaphragm and chick biventer cervicis preparations (time to 50% blockade with 0.35 mu M toxin: 58 +/- 4 and 24 +/- 1 min, respectively; n = 3-8; mean +/- S.E.) without significantly affecting the response to direct muscle stimulation. In chick preparations, contractures to exogenous acetylcholine (55 and 110 mu M) or KCl (13.4 mM) were unaltered after complete blockade by all toxin concentrations. These results, which strongly suggested a presynaptic mechanism of action for this toxin, were reinforced by (1) the inability of BaTX to interfere with the carbachol-induced depolarization of the resting membrane, (2) a significant decrease in the frequency and amplitude of miniature end-plate potentials, and (3) a significant reduction (59 +/- 4%, n=12) in the quantal content of the end-plate potentials after a 60 min incubation with the toxin (1.4 mu M). In addition, a decrease in the organ bath temperature from 37 degrees C to 24 degrees C and/or the replacement of calcium with strontium prevented the neuromuscular blockade, indicating a temperature-dependent effect possibly mediated by enzymatic activity. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
This in vitro research verified the possibility of eliminating staining caused by coffee and red wine in five composite resins, after being submitted to thermal cycling. Thirty-six specimens were prepared and immersed in water at 37 degrees C for 24 hours. After polishing, specimen color was measured in a spectrophotometer Cintra 10 UV (Visible Spectrometer, GBC, Braeside, VIC, Australia). All specimens were submitted to thermal cycling at temperatures of 5 and 55 degrees C with a dwell time of 1 minute, for 1,000 cycles in a 75% ethanol/water solution. After thermal cycling, the specimens were immersed in water at 37 degrees C until 7 days had elapsed from the time the specimens were prepared. All specimens were then taken to the spectrophotometer for color measurement. The specimens were divided into three groups (N = 12): distilled water (control), coffee, and red wine. For the staining process to occur on only one surface, all the sides, except one, of the surfaces were isolated with white wax. The specimens were immersed in one of the solutions at 37 degrees C for 14 days. The specimens were dried and taken to the spectrophotometer for color measurement. After this, the specimens were submitted to 20 mu m wear three times, and the color was measured after each one of the wear procedures. Calculation of the color difference was made using CIEDE2000 formula. According to the methodology used in this research, it was concluded that the staining caused by coffee and red wine was superficial and one wear of 20 mu m was sufficient to remove the discoloration.
Resumo:
Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.
Resumo:
The aim of this study was to investigate whether distinct cooling of low fluence erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation would influence adhesion. Main factors tested were: substrates (two), irradiation conditions (three), and adhesives (three). A 750 mu m diameter tip was used, for 50 s, 1 mm from the surface, with a 0.25 W power output, 20 Hz, energy density of 2.8 J/cm(2) with energy per pulse of 12.5 mJ. When applied, water delivery rate was 11 ml/min. The analysis of variance (ANOVA) showed that laser conditioning significantly decreased the bond strength of all adhesive systems applied on enamel. On dentin, laser conditioning significantly reduced bond strength of etch-and-rinse and one-step self-etch systems; however, laser irradiation under water cooling did not alter bonding of two-step self-etching. It may be concluded that the irradiation with Er,Cr:YSGG laser at 2.8 J/cm(2) with water coolant was responsible for a better adhesion to dentin, while enamel irradiation reduced bond strength, irrespective of cooling conditions.