967 resultados para Noninvasive Ventilation
Resumo:
Natural ventilation system facilitates gaseous exchanges in in vitro plants promoting changes in the leaf tissue, which can be evaluated through the leaf anatomy, and it allows a cultivation closer to the photoautrophic micropropagation. The objective of this work was to evaluate the effects on in vitro growth and on the leaf anatomy of Cattleya walkeriana grown in natural and conventional ventilation system with different concentrations of sucrose (0; 15; 30 and 45 L-1) combined with different cultivation systems (conventional micropropagation and natural ventilation system). The culture medium was composed of MS salts, solidified with 7 g L-1 of agar and pH adjusted to 5.8. Forty milliliters of culture medium were distributed in 250 mL flasks, autoclaved at 120 ºC for 20 minutes. The greater plant growth, as well as the greater thickness of the mesophyll was observed with the use of 20 g L-1 sucrose in natural ventilation system. Plants grown in natural ventilation system showed a thicker leaf mesophyll, which is directly related to photoautotrophic crops. The natural ventilation system induced more elliptical stomata and probably more functional formats.
Ventilation influence in occupational exposure to fungi and volatile organic compounds: poultry case
Resumo:
Introduction - In poultry houses, large-scale production has led to increased bird densities within buildings. Such high densities of animals kept within confined spaces are a source of human health problems related to occupational organic dust exposure. This organic dust is composed of both non-viable particles and viable particulate matter (also called bioaerosols). Bioaerosols are comprised by airborne bacteria, fungi, viruses and their by-products, endotoxins and mycotoxins. Exposure to fungi in broiler houses may vary depending upon the applied ventilation system. Ventilation can be an important resource in order to reduce air contamination in these type of settings. Nevertheless, some concerns regarding costs, sensitivity of the animal species to temperature differences, and also the type of building used define which type of ventilation is used. Aim of the study - A descriptive study was developed in one poultry unit aiming to assess occupational fungal and volatile organic compounds (VOCs) exposure.
Resumo:
Nowadays, most individuals spend about 80% of their time indoor and, consequently, the exposure to the indoor environment becomes more relevant than to the outdoor one. Children spend most of their time at home and at school and evaluations of their indoor environment are important for the time-weighted exposure. Due to their airways still in development, children are a sensitive group with higher risk than adults. Larger impact in health and educational performance of children demand indoor air quality studies of schools. The aim of this study was to assess the children exposure to bioaerosols. A methodology based upon passive sampling was applied to evaluate fungi, bacteria and pollens; its procedures and applicability was optimized. An indoor air study by passive sampling represents an easier and cheaper method when comparing with the use of automatic active samplers. Furthermore, it is possible to achieve important quality information without interfering in the classroom activities. The study was conducted in three schools, representative of different environments in the Lisbon urban area, at three different periods of the year to obtain a seasonal variation, to estimate the variability through the city and to understand the underneath causes. Fungi and bacteria were collected indoor and outdoor of the classrooms to determine the indoor/outdoor ratios and to assess the level of outdoor contamination upon the indoor environment. The children's exposure to pollen grains inside the classrooms was also assessed.
Resumo:
Agricultural workers especially poultry farmers are at increased risk of occupational respiratory diseases. Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers. In poultry production volatile organic compounds (VOCs) presence can be due to some compounds produced by molds that are volatile and are released directly into the air. These are known as microbial volatile organic compounds (MVOCs). Because these compounds often have strong and/or unpleasant odors, they can be the source of odors associated with molds. MVOC's are products of the microorganisms primary and secondary metabolism and are composed of low molecular weight alcohols, aldehydes, amines, ketones, terpenes, aromatic and chlorinated hydrocarbons, and sulfur-based compounds, all of which are variations of carbon-based molecules.
Resumo:
Introdução: A realização de broncofibroscopia (BF) a doentes com insuficiência Respiratória grave tem riscos e muitas vezes está contra-indicada. A aplicação de ventilação mecânica não invasiva (VMNI) para assistir a ventilação espontânea durante a BF pode ser constituir uma boa alternativa . Objectivo: Comparar a utilização de VMNI e do CPAP Boussignac (CB), durante a BF, em doentes hipoxémicos e/ou hipercápnicos. Materiais e Metodos: 9 pacientes (1feminino) com hipoxemia definida por PaO2/FiO2<200 com necessidade de (BF) foram elegíveis para o estudo. Cinco indivíduos foram randomizados para o grupo VMNI (G1) e 4 para o grupo CB (G2). Resultados: A pressão parcial arterial de oxigénio (PaO2) melhorou no grupo total: 65,9 (21,9) vs de 94,4 (75,9) pós BF, p=0,03, assim como a relação PaO2/FiO2: 131,7 (129,0) e 150,7 (161, 3), pós BF, p=0,04. A saturação periférica de O2 média durante a BF não foi significativamente diferente comparando os dois grupos: 96,1 (6,9) no G1 vs 97,3 (0,3) no G2, (p=0,62). No G1, 1 paciente foi intubado. Conclusão: Estes resultados sugerem que a pressão positiva tem um papel importante como técnica coadjuvante da BF em pacientes hipoxémicos graves (PaO2/FiO2<200). Neste estudo preliminar nenhuma vantagem da VMNI vs CB.
Resumo:
COPD is a major cause of morbidity and mortality worldwide, representing a major public health problem due to the high health and economic resource consumption. Pulmonary rehabilitation is a standard care recommendation for these patients, in order to control the symptoms and optimize the functional capacity, reducing health care costs associated with exacerbations and activity limitations and participation. However, in patients with severe COPD exercise performance can be difficult, due to extreme dyspnea, decreased muscle strength and fatigue. In addition, hypoxemia and dyspnea during efforts and daily activities may occur, limiting their quality of life. Thus, NIV have been used as adjunct to exercise, in order to improve exercise capacity in these patients. However, there is no consensus for this technique recommendation. Our objective was to verify whether the use of NIV during exercise is effective than exercise without NIV in dyspnea, walked distance, blood gases and health status in COPD patients, through a systematic review and meta-analysis.
Resumo:
Buildings account for 40% of total energy consumption in the European Union. The reduction of energy consumption in the buildings sector constitute an important measure needed to reduce the Union's energy dependency and greenhouse gas emissions. The Portuguese legislation incorporate this principles in order to regulate the energy performance of buildings. This energy performance should be accompanied by good conditions for the occupants of the buildings. According to EN 15251 (2007) the four factors that affect the occupant comfort in the buildings are: Indoor Air Quality (IAQ), thermal comfort, acoustics and lighting. Ventilation directly affects all except the lighting, so it is crucial to understand the performance of it. The ventilation efficiency concept therefore earn significance, because it is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the spaces. The two indicators most internationally accepted are the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE). Nowadays with the developed of the Computational Fluid Dynamics (CFD) the behaviour of ventilation can be more easily predicted. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by the MicroFlo module of the IES-VE software for this two indicators. The main conclusions from this work were: that the values of the numerical simulations are in agreement with experimental measurements; the value of the CRE is more dependent of the position of the contamination source, that the strategy used for the air diffusion; the ACE indicator is more appropriate for quantifying the quality of the air diffusion; the solutions to be adopted, to maximize the ventilation efficiency should be, the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.
Resumo:
The objectives of this study were to determine the incidence of infection by respiratory viruses in preterm infants submitted to mechanical ventilation, and to evaluate the clinical, laboratory and radiological patterns of viral infections among hospitalized infants in the neonatal intensive care unit (NICU) with any kind of acute respiratory failure. Seventy-eight preterm infants were studied from November 2000 to September 2002. The newborns were classified into two groups: with viral infection (Group I) and without viral infection (Group II). Respiratory viruses were diagnosed in 23 preterm infants (29.5%); the most frequent was respiratory syncytial virus (RSV) (14.1%), followed by influenza A virus (10.2%). Rhinorrhea, wheezing, vomiting and diarrhea, pneumonia, atelectasis, and interstitial infiltrate were significantly more frequent in newborns with nosocomial viral infection. There was a correlation between nosocomial viral infection and low values of C-reactive protein. Two patients with mixed infection from Group I died during the hospital stay. In conclusion, RSV was the most frequent virus in these patients. It was observed that, although the majority of viral lower respiratory tract infections had a favorable course, some patients presented a serious and prolonged clinical manifestation, especially when there was concomitant bacterial or fungal infection.
Resumo:
Modelling of ventilation is strongly dependent on the physical characteristics of the building of which precise evaluation is a complex and time consuming task. In the frame of a research project, two children day care centres (CDCC) have been selected in order to measure the envelope air permeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature. The data obtained was used as input to the computer code CONTAM for ventilation simulations. The results obtained were compared with direct measurements of ventilation flow from short term measurements with CO2 tracer gas and medium term measurements with perfluorocarbon tracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affect ventilation, the model was used to predict the ventilation rates for a wide range of conditions. The purpose of this assessment was to find the best practices to improve natural ventilation. A simple analytical method to predict the ventilation flow rate of rooms is also presented. The method is based on the estimation of wind effect on the room through the evaluation of an average factor and on the assessment of relevant cross section of gaps and openings combined in series or in parallel. It is shown that it may be applied with acceptable accuracy for this type of buildings when ventilation is due essentially to wind action.
Resumo:
Nowadays natural ventilation has gained prominence because its correct use can reduce energy consumption for cooling systems and improve thermal comfort among users. In this paper, we report on the modelling initiative, based on the wind tunnel tests that were carried out for the determination of the influence of natural ventilation in buildings. Indeed, the renewal of air in a closed environment without using an air conditioning system with mechanical elements can lead to energy savings and, in addition, provide air quality.The wind tunnel tests were carried out by varying the positioning of six ventilation modules in the façade system configuration. The modules were positioned below the window-sill (ventilated window-sill) as well as separately above and below the façade. The wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. The results supported the positioning of the six ventilation modules below the window-sill, forming a â ventilated window-sillâ as the most effective natural ventilation solution.
Resumo:
Wind tunnel tests are a reliable tool to determine the effect of natural ventilation on buildings. This paper presents results of wind tunnel tests conducted to evaluate the influence of ventilation modules positioning on a façade system. Modules positioning was modified, resulting in different façade configurations. The tests were carried out with the use of a model, varying the position of the ventilation modules in the façade configuration. The cases tested were six ventilation modules positioned below the window-sill (ventilated window-sill), and three ventilation modules positioned above and below the façade. The façade system proposed was movable and interchangeable so that the same basic model could be used to test the possibilities for ventilation. Wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. Singleâ sided and Cross ventilation were considered for wind speed measurements. Results show the use of six ventilation modules positioned below the window-sill, forming "a ventilated window-sill" is the best solution in terms of natural ventilation.
Resumo:
Objectives: The therapeutic effects of transcranial magnetic stimulation (TMS) and transcranial direct current stimulation in patients with major depression have shown promising results; however, there is a lack of mechanistic studies using biological markers (BMs) as an outcome. Therefore, our aim was to review noninvasive brain stimulation trials in depression using BMs. Methods: The following databases were used for our systematic review: MEDLINE, Web of Science, Cochrane, and SCIELO. We examined articles published before November 2012 that used TMS and transcranial direct current stimulation as an intervention for depression and had BM as an outcome measure. The search was limited to human studies written in English. Results: Of 1234 potential articles, 52 articles were included. Only studies using TMS were found. Biological markers included immune and endocrine serum markers, neuroimaging techniques, and electrophysiological outcomes. In 12 articles (21.4%), end point BM measurements were not significantly associated with clinical outcomes. All studies reached significant results in the main clinical rating scales. Biological marker outcomes were used as predictors of response, to understand mechanisms of TMS, and as a surrogate of safety. Conclusions: Functional magnetic resonance imaging, single-photon emission computed tomography, positron emission tomography, magnetic resonance spectroscopy, cortical excitability, and brain-derived neurotrophic factor consistently showed positive results. Brain-derived neurotrophic factor was the best predictor of patients’ likeliness to respond. These initial results are promising; however, all studies investigating BMs are small, used heterogeneous samples, and did not take into account confounders such as age, sex, or family history. Based on our findings, we recommend further studies to validate BMs in noninvasive brain stimulation trials in MDD.
Resumo:
OBJECTIVE: To determine the predictive values of noninvasive tests for the detection of allograft vascular disease. METHODS: We studied 39 patients with mean ages of 48±13 years and a follow-up period of 86±13 months. The diagnosis of allograft vascular disease was made by cine-coronary arteriography, and it was considered as positive if lesions existed that caused > or = 50% obstruction of the lumen. Patients underwent 24h Holter monitoring, thallium scintigraphy, a treadmill stress test, and dobutamine stress echocardiography. Sensitivity, specificity, and positive and negative predictive values were determined in percentages for each method, as compared with the cine-coronary arteriography results. RESULTS: Allograft vascular disease was found in 15 (38%) patients. The Holter test showed 15.4% sensitivity, 95.5% specificity. For the treadmill stress test, sensitivity was 10%, specificity was 100%. When thallium scintigraphy was used, sensitivity was 40%, specificity 95.8%. On echocardiography with dobutamine, we found a 63.6% sensitivity, 91.3% specificity. When the dobutamine echocardiogram was associated with scintigraphy, sensitivity was 71.4%, specificity was 87%. CONCLUSION: In this group of patients, the combination of two noninvasive methods (dobutamine echocardiography and thallium scintigraphy) may be a good alternative for the detection of allograft vascular disease in asymptomatic patients with normal ventricular function.