991 resultados para Newborn infants - Metabolism
Resumo:
OBJECTIVE: To report a full-term newborn infant that developed a sepsis associated to meningitis caused by Neisseria meningitidis serogroup C on the 14th day of life. CASE DESCRIPTION: The patient was a term female infant, born to a mother with Systemic Lupus Erythematosus, with birth weight of 2,610g, Apgar Score 1, 4 and 8, who needed mechanical ventilation for 24 hours. On the 7th day of life, the neonate was discharged from the hospital with good overall condition. On the 15th day of life, the newborn infant presented fever and respiratory failure. The cerebrospinal fluid showed 1042 cells/mm³, with neutrophilic predominance, protein of 435 mg/dL, and glucose < 10 mg/dL. The blood and the cerebrospinal fluid cultures were positive for Neisseria meningitidis serogroup C. The neonate was hospitalized, needing mechanical ventilation and vasoactive drugs, and received 21 days of crystalline penicillin. After hospital discharge, there were no signs of neurological sequels and the infant was able to be breastfed. The case report presents a unique situation: an uncommon etiology of neonatal meningitis and favorable evolution, despite neurological sequels reported in the literature. This report emphasizes the need to prevent the premature exposure of newborn infants to pathological agents, especially if they presented birth injuries and/or are preterm, due to their lack of immunological capacity.
Resumo:
Introduction: Antibiotics are one of the most common prescribed drugs in the NICU; despite this, studies on its use are scarce. Aim: To assess antibiotics utilization ratio in a medical surgical NICU. Methods: Prospective, observational study. Daily registry of antibiotics given to newborn infants; two periods of two months, 2010; data collected every day after the second medical round. Variables: treated patients, days on antibiotics, treatment/patient days, number of courses, number of antibiotics. Antibiotics utilization ratio – ratio days on antibiotics/days at the NICU. Results: Patients enrolled - 113; admission days – 1722; length of stay - 15.2 days; 85 newborn infants were given antibiotics; days on antibiotics - 771; antibiotics utilization ratio – 44.8; 292 antibiotics were prescribed; 61.8% of patients were given more than two antibiotics and 15.3% had more than one course. The most frequents were gentamicin, cefotaxime, ampicillin, vancomycin and metronidazole. Conclusion: Antibiotics utilization ratio should be subject of audits and a quality criteria on NICUs evaluation.
Vitaminas, Minerais e Oligoelementos por Via Entérica no Recém-Nascido. Revisão do Consenso Nacional
Resumo:
Na presente atualização da recomendação sobre vitaminas, minerais e oligoelementos por via entérica no recém-nascido, é dada especial relevância às necessidades destes micronutrientes do recém-nascido de termo e pré-termo, suprimentos fornecidos pelo leite materno, leite humano fortificado, fórmulas lácteas para recém-nascido de termo e pré-termo comercializadas em Portugal e suplementos recomendados por rotina no recém-nascido de termo e pré-termo.
Resumo:
INTRODUCTION: Reduction in the vertical transmission of HIV is possible when prophylactic measures are implemented. Our objective was to determine demographic characteristics of HIV-infected pregnant women and the rate of mother-to-child transmission of HIV in Manaus, Amazonas, Brazil. METHODS: A descriptive study was conducted using notification, and investigating data from the Notifiable Diseases Data System in the Brazilian State of Amazonas, between 2007 and 2009. RESULTS: During the study period, notification was received of 509 HIV-positive pregnant women. The vertical transmission was 9.9% (95% CI: 7.2-12.6%). The mean age of women was 27 years (SD: 5.7), and the majority (54.8%) had not completed elementary school (eighth grade). Diagnosis of HIV seropositivity was made prior to pregnancy in 115 (22.6%) women, during prenatal care in 302 (59.3%), during delivery in 70 (13.8%), and following delivery in 22 (4.3%). Four hundred four of these women (79.4%) had had prenatal care, with 79.4% of patients receiving antiretroviral during pregnancy and 61.9% of the newborn infants receiving prophylaxis. In the final multivariate logistic regression model, living in urban area [OR = 0.7 (95% CI: 0.35-0.89)] and having had prenatal care [OR = 0.1 (95% CI: 0.04-0.24)] remained as protective factors against vertical HIV transmission in this population. CONCLUSIONS: The relevance of adequate compliance with the measures already established as being effective in guaranteeing a reduction in HIV transmission within the maternal and infant population should be emphasized.
Resumo:
INTRODUCTION: The aim of this study was to assess the epidemiological characteristics of Trypanosoma cruzi-infected mothers and the live birth conditions of neonates.METHODS:A serological survey with IgG-specific tests was conducted using dried blood samples from newborn infants in the State of Minas Gerais. T. cruzi infection was confirmed in mothers through positive serology in two different tests, and infected mothers were required to have their infants serologically tested after the age of 6 months. The birth conditions of the neonates were obtained from the System of Information on Live Births database.RESULTS:The study included 407 children born to T. cruzi-infected mothers and 407 children born to uninfected mothers. The average age of seropositive mothers was 32 years (CI95% 31.3-32.6), which was greater than the average age of seronegative mothers - 25 years (CI95% 24.8-25.2). The mothers' level of education was higher among uninfected mothers (41% had 8 or more years of education, versus 22% between the infected mothers). Vaginal delivery was more frequent among infected mothers. There was no evidence of inter-group differences with respect to the child's sex, gestational age, birth weight or Appearance, pulse, grimace, activity and respiration (APGAR) scores at 1 and 5 minutes.Conclusions:The level of education and the greater number of previous pregnancies and cases of vaginal delivery reflect the lower socioeconomical conditions of the infected mothers. In the absence of vertical transmission, neonates had similar health status irrespective of the infection status of their mothers.
Resumo:
INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.
Resumo:
OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2±1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure). Five of the other 7 patients underwent a new procedure and 2 required surgery.CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.
Resumo:
The pathogenesis of Duchenne muscular dystrophy (DMD), characterised by lack of the cytoskeletal protein dystrophin, is not completely understood. An early event in the degenerative process of DMD muscle could be a rise in cytosolic calcium concentration. In order to investigate whether this leads to alterations of contractile behaviour, we studied the excitability and contractile properties of cultured myotubes from control (C57BL/10) and mdx mice, an animal model for DMD. The myotubes were stimulated electrically and their motion was recorded photometrically. No significant differences were found between control and mdx myotubes with respect to the following parameters: chronaxy and rheobase (0.33 +/- 0.03 ms and 23 +/- 4 V vs. 0.39 +/- 0.07 ms and 22 +/- 2 V for C57 and mdx myotubes, respectively), tetanisation frequency (a similar distribution pattern was found between 5 and 30 Hz), fatigue during tetanus (found in 35% of both types of myotubes) and post-tetanic contracture. In contrast, contraction and relaxation times were longer (P < 0.005) in mdx (36 +/- 2 and 142 +/- 13 ms, respectively) than in control myotubes (26 +/- 1 and 85 +/- 9 ms, respectively). Together with our earlier findings, these results suggest a decreased capacity for calcium removal in mdx cells leading, in particular, to alterations of muscle relaxation.
Resumo:
Chemotherapy-induced anemia in children with cancer is usually of acute onset. To investigate an alternate treatment to transfusion (Tx), we undertook a phase I-II clinical trial of daily administrations of recombinant erythropoietin (rHuEPO). Patients with a hemoglobin (Hgb) value < 75 g/l were treated for 14 days in cohorts of 3 at escalating daily doses of 25, 50, 70, 80, 90, and 100 U/kg respectively. The maximum-tolerated dose was not encountered. Of 18 courses given to 15 children aged 0.5-18 years, 7 (39%) were associated with increased or stable Hgb levels (courses without Tx), while 11 (61%) were terminated by a Tx, without evidence of a dose-response relationship. Changes in mean Hgb levels and absolute reticulocyte counts were paralleled by those of mean white blood cell, platelet, and absolute neutrophil counts during the first 7 days and when the end-points of the study were reached. Numbers of circulating burst-forming units-erythroid remained low throughout courses without Tx. No cumulative increase of serially determined serum EPO levels was observed and serum ferritin levels were elevated in both groups of courses. We conclude that daily administration of rHuEPO were safe but ineffective in our trial. Recovery of chemotherapy-induced myelosuppression appeared to be the rate-limiting factor for the outcome, without evidence of an enhanced stimulation of erythropoiesis. The lack of a proliferative response of specific progenitor cells suggested a mechanism of transient primary resistance to rHuEPO.
Resumo:
Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.
Resumo:
Near infrared spectroscopy (NIRS) is a non-invasive method of estimating the haemoglobin concentration changes in certain tissues. It is frequently used to monitor oxygenation of the brain in neonates. At present it is not clear whether near infrared spectroscopy of other organs (e.g. the liver as a corresponding site in the splanchnic region, which reacts very sensitively to haemodynamic instability) provides reliable values on their tissue oxygenation. The aim of the study was to test near infrared spectroscopy by measuring known physiologic changes in tissue oxygenation of the liver in newborn infants during and after feeding via a naso-gastric tube. The test-retest variability of such measurements was also determined. On 28 occasions in 25 infants we measured the tissue oxygenation index (TOI) of the liver and the brain continuously before, during and 30 minutes after feeding via a gastric tube. Simultaneously we measured arterial oxygen saturation (SaO2), heart rate (HR) and mean arterial blood pressure (MAP). In 10 other newborn infants we performed a test-retest analysis of the liver tissue oxygenation index to estimate the variability in repeated intra-individual measurements. The tissue oxygenation index of the liver increased significantly from 56.7 +/- 7.5% before to 60.3 +/- 5.6% after feeding (p < 0.005), and remained unchanged for the next 30 minutes. The tissue oxygenation index of the brain (62.1 +/- 9.7%), SaO2 (94.4 +/- 7.1%), heart rate (145 +/- 17.3 min-1) and mean arterial blood pressure (52.8 +/- 10.2 mm Hg) did not change significantly. The test-retest variability for intra-individual measurements was 2.7 +/- 2.1%. After bolus feeding the tissue oxygenation index of the liver increased as expected. This indicates that near infrared spectroscopy is suitable for monitoring changes in tissue oxygenation of the liver in newborn infants.
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
The immunogenicity and safety of a new recombinant hepatitis B vaccine from the Instituto Butantan (Butang®) were evaluated in a multicenter, double-blind, prospective equivalence study in three centers in Brazil. Engerix B® was the standard vaccine. A total of 3937 subjects were recruited and 2754 (70%) met all protocol criteria at the end of the study. All the subjects were considered healthy and denied having received hepatitis B vaccine before the study. Study subjects who adhered to the protocol were newborn infants (566), children 1 to 10 years old (484), adolescents from 11 to 19 years (740), adults from 20 to 30 years (568), and adults from 31 to 40 years (396). Vaccine was administered in three doses on the schedule 0, 1, and 6 months (newborn infants, adolescents, and adults) or 0, 1, and 7 months (children). Vaccine dose was intramuscular 10 µg (infants, children, and adolescents) or 20 µg (adults). Percent seroprotection (assumed when anti-HBs titers were > 10mIU/ml) and geometric mean titer (mIU/ml) were: newborn infants, 93.7% and 351.1 (Butang®) and 97.5% and 1530.6 (Engerix B®); children, 100% and 3600.0 (Butang®) and 97.7% and 2753.1 (Engerix B®); adolescents, 95.1% and 746.3 (Butang®) and 96% and 1284.3 (Engerix B®); adults 20-30 years old, 91.8% and 453.5 (Butang®) and 95.5% and 1369.0 (Engerix B®); and adults 31-40 years old, 79.8% and 122.7 (Butang®) and 92.4% and 686.2 (Engerix B®). There were no severe adverse events following either vaccine. The study concluded that Butang® was equivalent to Engerix B® in children, and less immunogenic but acceptable for use in newborn infants, adolescents, and young adults.
Resumo:
The aim of this study was to evaluate the utility of western blot (WB) analysis as a diagnostic tool for congenital toxoplasmosis in 215 newborn infants. The children were submitted to clinical examinations to assess macular, neurological and hearing signals. The WB results obtained were compared to the persistence of IgG antibodies at the end of 12 months, which is regarded as the "gold standard" diagnosis of congenital toxoplasmosis. Association between the WB results and the clinical signs presented by the infants was also assessed. Of the 215 children, 177 had a confirmed congenital toxoplasmosis diagnosis and 38 were uninfected. IgG-WB showed a sensitivity of 73.5% and a specificity of 97.4%. IgM-WB showed a sensitivity of 54.8% and a specificity of 94.7%. The IgG-WB and IgM-WB combination increased the sensitivity to 86.5%. The IgM-WB-positive children had a 1.4-fold greater risk of presenting active macular lesions than did those that were IgM-WB-negative. This study showed that the WB assay is a useful tool to confirm a diagnosis of congenital toxoplasmosis and that the IgM-WB-positive results can indicate active macular lesions in newborn infants.
Resumo:
Recently, it was suggested that maternal hepatitis B surface antigen antibodies (anti-HBs) acquired transplacentally could play a negative role in newborn infants' immune response to the hepatitis B vaccine. We compared the hepatitis B virus (HBV) vaccine response in infants born to mothers previously vaccinated against HBV (n = 91) to infants born to mothers who were not previously vaccinated (n = 221). All newborn infants received three intramuscular doses (10 μg) of HBV vaccine (Butang®) at 0,1 and six months. The first dose was administered at the maternity hospital within 12 h of birth. The geometric mean titres of anti-HBs were not different among newborn infants born to mothers who were anti-HBs-negative (492.7 mIU/mL) and anti-HBs-positive (578.7 mIU/mL) (p = 0.38). Eight infants did not respond to the HBV vaccine. Of them, six were born to anti-HBs-negative mothers and two were born to mothers with anti-HBs titres less than 50 mlU/mL. Despite the mother's anti-HBs-positive status, our data show a good immunogenicity of the Brazilian HBV recombinant vaccine in neonates.