976 resultados para Needle Biopsy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We here report the case history of a 75-yr-old woman who developed pancreatitis and recurrent symptomatic, cholestasis-induced hemobilia after percutaneous liver biopsy. An endoscopic sphincterotomy with clot extraction led to relief of symptoms. The risk of hemobilia after percutaneous liver biopsy is less than one per 1000 procedures, and only two cases of acute pancreatitis after percutaneous liver biopsy have previously been reported. To our knowledge, this is the first case in which endoscopic retrograde cholangiopancreatography was used to both diagnostic and therapeutic ends.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In cases of transjugular liver biopsies, the venous angle formed between the chosen hepatic vein and the vena cava main axis in a frontal plane can be large, leading to technical difficulties. In a prospective study including 139 consecutive patients who underwent transjugular liver biopsy using the Quick-Core biopsy set, the mean venous angle was equal to 49.6 degrees. For 21.1% of the patients, two attempts at hepatic venous catheterization failed because the venous angle was too large, with a mean of 69.7 degrees. In all of these patients, manual reshaping of the distal curvature of the stiffening metallic cannula, by forming a new mean angle equal to 48 degrees , allowed successful completion of the procedure in less than 10 min.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knowledge of the pathological diagnosis before deciding the best strategy for treating parasellar lesions is of prime importance, due to the relative high morbidity and side-effects of open direct approaches to this region, known to be rich in important vasculo-nervous structures. When imaging is not evocative enough to ascertain an accurate pathological diagnosis, a percutaneous biopsy through the transjugal-transoval route (of Hartel) may be performed to guide the therapeutic decision.The chapter is based on the authors' experience in 50 patients who underwent the procedure over the ten past years. There was no mortality and only little (mostly transient) morbidity. Pathological diagnosis accuracy of the method revealed good, with a sensitivity of 0.83 and a specificity of 1.In the chapter the authors first recall the surgical anatomy background from personal laboratory dissections. They then describe the technical procedure, as well as the tissue harvesting method. Finally they define indications together with the decision-making process.Due to the constraint trajectory of the biopsy needle inserted through the Foramen Ovale, accessible lesions are only those located in the Meckel trigeminal Cave, the posterior sector of the cavernous sinus compartment, and the upper part of the petroclival region.The authors advise to perform this percutaneous biopsy method when imaging does not provide sufficient evidence of the pathological nature of the lesion, for therapeutic decision. Goal is to avoid unnecessary open surgery or radiosurgery, also inappropriate chemo-/radio-therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The measurement of calcitonin in washout fluids of thyroid nodule aspirate (FNA-calcitonin) has been reported as accurate to detect medullary thyroid carcinoma (MTC). The results from these studies have been promising and the most updated version of ATA guidelines quoted for the first time that "FNA findings that are inconclusive or suggestive of MTC should have calcitonin measured in the FNA washout fluid." Here we aimed to systematically review published data on this topic to provide more robust estimates. RESEARCH DESIGN AND METHODS: A comprehensive computer literature search of the medical databases was conducted by searching for the terms "calcitonin" AND "washout." The search was updated until April 2015. RESULTS: Twelve relevant studies, published between 2007 and 2014, were found. Overall, 413 thyroid nodules or neck lymph nodes underwent FNA-calcitonin, 95 were MTC lesions and 93 (97.9%) of these were correctly detected by this measurement regardless of their cytologic report. CONCLUSIONS: The present study shows that the above ATA recommendation is well supported. Almost all MTC lesions are correctly detected by FNA-calcitonin and this technique should be used to avoid false negative or inconclusive results from cytology. The routine determination of serum calcitonin in patients undergoing FNA should improve the selection of patients at risk for MTC, guiding the use of FNA-calcitonin in the same FNA sample and providing useful information to the cytopathologist for the morphological assessment and the application of tailored ancillary tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the number of punctures in fine-needle aspiration biopsies required for a safe cytological analysis of thyroid nodules. MATERIALS AND METHODS: Cross-sectional study with focus on diagnosis. The study population included 94 patients. RESULTS: The mean age of the patients participating in the study was 52 years (standard-deviation = 13.7) and 90.4% of them were women. Considering each puncture as an independent event, the first puncture has showed conclusive results in 78.7% of cases, the second, in 81.6%, and the third, in 71.8% of cases. With a view to the increasing chance of a conclusive diagnosis at each new puncture, two punctures have showed conclusive results in 89.5% of cases, and three punctures, in 90.6% of cases with at least one conclusive result. CONCLUSION: Two punctures in fine-needle aspiration biopsies of thyroid nodules have lead to diagnosis in 89.5% of cases in the study sample, suggesting that there is no need for multiple punctures to safely obtain the diagnosis of thyroid nodules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Objective: To propose an algorithm to determine the necessity for ultrasonography-guided fine-needle aspiration (US-FNA) in preoperative axillary lymph node staging of patients with invasive breast cancer. Materials and Methods: Prospective study developed at National Cancer Institute. The study sample included 100 female patients with breast cancer referred for axillary staging by US-FNA. Results: The overall US-FNA sensitivity was set at 79.4%. The positive predictive value was calculated to be 100%, and the negative predictive value, 69.5%. The US-FNA sensitivity for lymph nodes with normal sonographic features was 0%, while for indeterminate lymph nodes it was 80% and, for suspicious lymph nodes, 90.5%. In the assessment of invasive breast tumors stages T1, T2 and T3, the sensitivity was respectively 69.6%, 83.7% and 100%. US-FNA could avoid sentinel node biopsy in 54% of cases. Conclusion: Axillary ultrasonography should be included in the preoperative staging of all patients with invasive breast cancer. The addition of US-FNA in cases of lymph nodes suspicious for malignancy may prevent more than 50% of sentinel lymphadenectomies, significantly shortening the time interval to definitive therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P. zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although several methods of testicular biopsy have been proposed previously, testicular fine needle aspiration (FNA) has proved to be the simplest, the most rapid, inexpensive, and overall the least invasive technique for obtaining testicular biopsies Testicular FNA is indicated for fertility investigations in stallions with oligozoospermia or azoospermia It is also used for differential diagnosis of testicular enlargement After sedation the stallion's testis is punctured to obtain testicular parenchyma samples containing cells mainly from the seminiferous epithelium the material obtained is used to perform smears which are analyzed for identification and quantification of term cells and Sertoli cells The results are based on the presence of the cell types found in the smears and the proportions of Sertoli cells per germ cells In addition to being a very useful diagnostic tool, testicular FNA is also used for follow-up examinations, as it is minimally invasive

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: This study was undertaken to assess whether fine needle aspirates from non-Hodgkins lymphoma (NHL) could be used for growth fraction analysis with proliferating cell nuclear antigen (PCNA) staining and if there was a relationship between the growth fraction and cytomorphologic classification according to the Kiel classification.STUDY DESIGN: the study group consisted of 40 patients with NHL diagnosed by fine needle aspiration (FNA) cytology. The cytologic classification of the lymphomas was made by two cytopathologists on May-Grunwald-Giemsa-stained slides using the Kiel classification. There were 27 cases of low and 13 of high grade lymphoma. The estimation of the growth fraction was made by PCNA immunoreactivity. The PCNA index was quantitated in smears by counting an average of 1,000 cells, and the count teas correlated with the cytomorphologic classification.RESULTS: There was It strong correlation between the PCNA index and lymphoma grading. High grade lymphomas exhibited a mean PCNA positivity of 74.0%, which was significantly higher (P <.001) than that of low grade lymphomas (17.6%).CONCLUSION: Our study showed that PCNA evalua tion is suitable for smears obtained by FNA on NHL, correlates with increasing grades of lymphoma according to the Kiel classification and may offer a method of monitoring treatment of lymphoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cytomorphologic characteristics of smears from fine-needle aspirates (FNA) of three cases of sinus histiocytosis with massive lymphadenopathy (SHML) (Rosai-Dorfman disease) are described. All aspirates showed mature lymphocytes, plasma cells, and large pale histiocytes with well-preserved lymphocytes within the cytoplasm (lymphocytophagocytosis). The cases were confirmed by surgical biopsy, and the immunohistochemical findings suggested a macrophage origin for this lesion. The value of FNA analysis as an aid to diagnosis of SHML is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sequelae due to testicular biopsy such as hemorrhage, adhesion and fibrosis may be limiting factors to the use of this surgical procedure. Fibrin glue (FG) derived from snake venom was used to minimize these sequelae, as well as to evaluate its healing property in tunica vaginalis and scrotal skin of rams. Applicability of fibrin glue derived from snake venom was tested in different tissues of other animals such as in sciatic nerve and colon of rats and skin of rabbits. In the present study, 30 healthy adult rams were used. They were divided into 3 groups of 10 animals each as follows: G1: fibrin glue group (application of fibrin glue on puncture sites and skin incisions after bilateral testicular biopsy with a Tru-Cut needle); G2: swab/nylon group (hemostasis by compression with a swab on puncture sites and skin suturing with nylon after biopsy) and G3: control group (the animals were not subjected either to biopsy or to surgery). On the 20th day after biopsy, the presence of adhesion strands between the sites of skin incision and testicle was evaluated by palpation Adhesion strands were found in three testicles (15%) in G1 and in two testicles (10%) in G2. One hundred days after biopsy, orchiectomy was carried out and the material collected was assessed for subcutaneous (SC) and/or tunica vaginalis adhesions. G3 did not present any abnormality. Groups G1 and G2 presented four testicles each (20%) with adhesion between the tunics at biopsy site. On the other hand, subcutaneous adhesions were found once (5%) in G1 and three times (15%) in G2. Fibrin glue showed to be of easy application, required short postoperative monitoring, presented fast and good-quality healing property and tended to reduce formation of subcutaneous adhesion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To evaluate the reliability of fine needle aspirate cell blocks in the assessment of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins by immunohistochemistry in comparison with surgical specimens. Materials and methods: This is a retrospective study of 62 cases of breast carcinoma diagnosed by fine needle aspiration cytology (FNAC) and confirmed using the surgical specimen. Immunohistochemical tests were performed to assess the presence of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins in cell blocks and the corresponding surgical specimens. The cell block method used alcohol prior to formalin fixation. Cases with 10% or more stained cells were considered positive for ER and PR. Positivity for HER-2/neu was assessed on a scale of 0-3+. The criterion for positivity was a score of 3+. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the cell blocks in the investigation of ER, PR and HER-2/neu protein (3+) were (%): ER, 92.7, 85.7, 92.7, 85.7 and 90.3; PR, 92.7, 94.7, 97.4, 87.0 and 93.5; HER-2/neu, 70.0, 100.0, 100.0, 94.5 and 95.2. Discrepancies were seen in cell blocks in the 1+ and 2+ HER-2/neu staining scores: two of 12 cases scoring 2+ and one case of 26 scoring 1+ on cell blocks scored 3+ on surgical specimens. The correlation index between cell block and corresponding surgical specimen varied from 90% to 94%. Conclusion: Cell blocks provide a useful method of assessing ER, PR and HER-2/neu, mainly for inoperable and recurrent cases, but consideration should be given to carrying out FISH analysis on 1+ as well as 2+ HER-2/neu results. © 2012 Blackwell Publishing Ltd.