773 resultados para Narrative Inquiry
Resumo:
Considering the importance of neosporosis in the animal health and production, the frequency of antibodies to Neospora caninum was evaluated in dairy cattle of the Southwestern region of Mato Grosso State, Brazil, in addition to serum samples obtained from dogs and humans living in the farms. A total of 1036 serum samples were analyzed, from which 932 were from dairy bovine females, 37 from dogs and 67 from humans, from 24 farms and examined by the indirect fluorescent antibody test (IFAT). Reactive human scrum samples were retested by Western-blotting to confirm the results. Antibodies to N. caninum were found in 499 cattle sera (53.5 %), with at least one positive in each farm, 25 dog sera (67.6 %) and seven human sera (10.5 %). There was no significant difference in the number of positive cattle sera according to age group. The results indicate a wide dissemination of N caninum in the studied region.
Resumo:
Hermeneutic Case Reconstruction (Rosenthal, 1993) is a systematic method of analysing biographical self-presentations from an interpretivist perspective. The method consists of five major analytic steps. The first is an analysis of the biographical data that can stand independently of the narrator’s perspective. Objective data is extracted from the text or interview transcript and ordered chronologically. Secondly, a thematic field analysis is undertaken in which the data is divided into separate units according to the type of text used, whilst keeping the sequence of these texts units intact. In this step, hypotheses are developed regarding the potential significance of the style and sequence of the events presented. The product of this second step is a reconstruction of the life story. A reconstruction of the life history then follows as the third step. The purpose of this step is to generate hypotheses about the meanings that biographical experiences might have had for the narrator at the time they occurred, given the sociocultural context in which they occurred. In the fourth step, microanalysis of individual text segments is undertaken, in which all hypotheses generated in the earlier steps are tested against the text for support or refutation. The final step consists of a contrastive comparison of the life history and life story. The life story and life history are compared to determine, for example, which aspects of the narrator’s experience have been emphasised or minimised. Through this comparison, the selective process is highlighted. This is referred to as the case structure. This paper describes an application of this method to a published first-person narrative of a woman’s experiences of sustaining a brain injury in a motor vehicle accident.
Writing the body of the mother: Narrative moments in Tsushima Yuko, Ariyoshi Sawako and Enchi Fumiko
Resumo:
This discussion argues the transformative potential inherent in the corporeal experience of motherhood as represented in selected textual moments of Japanese narrative. Narratives that address the experiences of the body of the mother are informed and given substance by an intense physicality, and thus have the potential to contest processes of social inscription in addition to suggesting alternative possibilities for all readers, not just those occupying an embodied maternal space. The discussion features brief events from the work of three writers who have written as mothers: Tsushima Y(u)macrko, Ariyoshi Sawako and Enchi Fumiko. In Yama o hashiru onna (1980; translated as Woman Running in the Mountains, 1991), Tsushima Y(u)macrko invites the reader to consider the embodied response to light of Takiko, a young pregnant woman. Emiko, the protagonist of Hishoku (Without Colour, 1967) by Ariyoshi Sawako, is the Japanese wife of an African American and has just given birth to a child. The daughter protagonist in Enchi Fumiko's 'Kami' ('Hair', 1957) operates a hairdressing business that is viable only with her mother's unpaid labour. The narratives are read through a matrix of post-structuralist theories of embodiment, drawing on the work of writers such as Julia Kristeva, Luce Irigaray and Elizabeth Grosz.
Resumo:
Eliza Fay’s Original Letters from India (1817), initially sold to the Calcutta Gazette to pay off her debts, aroused the curiosity and interest of Edward M. Forster, while he was doing research for his best-selling novel, A Passage to India. In his own words, “Eliza Fay is a work of art.” (apud Fay 7) The value of E. Fay’s travelogue, comprising not one, but three voyages to India (in 1779, 1784, 1796) can be easily explained if we take into account the scope of its geographical coverage, the hardships of its historical context (the political chaos brought about by the fall of the Mughal empire and the consolidation of the British rule in the Indian subcontinent) and the heroism of the first person-narrator that emerges behind the descriptive sketches and the scenes of adversity and imminent danger. Thus the current analysis will focus on the E. Fay’s adventurous mode of narrating, e.g., the discursive situatedness of the traveller visà- vis the Other(s) (European and non-European peoples and loci) and the constraints imposed by the patriarchal idealization of the domestic Woman and their alleged feebleness.
Resumo:
Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.