989 resultados para Nanometric displacement measurement
Resumo:
INTRODUCTION Investigations of the dynamic function of female pelvic floor muscles (PFM) help us to understand the pathophysiology of stress urinary incontinence (SUI). Displacement measurements of PFM give insight into muscle activation and thus help to improve rehabilitation strategies. This systematic review (PROSPERO 2013: CRD42013006409) was performed to summarise the current evidence for PFM displacement during voluntary and involuntary activation in continent and incontinent women. METHODS MEDLINE, EMBASE, Cochrane and SPORTDiscus databases were searched using selected terminology reflecting the PICO approach. Screening of Google Scholar and congress abstracts added to further information. Original articles investigating PFM displacement were included if they reported on at least one of the aims of the review, e.g., method, test position, test activity, direction and quantification of displacement, as well as the comparison between continent and incontinent women. Titles and abstracts were screened by two reviewers. The papers included were reviewed by two individuals to ascertain whether they fulfilled the inclusion criteria and data were extracted on outcome parameters. RESULTS Forty-two predominantly observational studies fulfilled the inclusion criteria. A variety of measurement methods and calculations of displacement was presented. The sample was heterogeneous concerning age, parity and continence status. Test positions and test activities varied among the studies. CONCLUSIONS The findings summarise the present knowledge of PFM displacement, but still lack deeper comprehension of the SUI pathomechanism of involuntary, reflexive activation during functional activities. We therefore propose that future investigations focus on PFM dynamics during fast and stressful impact tasks.
Resumo:
Comunicación presentada en EVACES 2011, 4th International Conference on Experimental Vibration Analysis for Civil Engineering Structures, Varenna (Lecco), Italy, October 3-5, 2011.
Resumo:
A self-reference fiber Michelson interferometer measurement system, which employs fiber Bragg gratings (FBGs) as in-fiber reflective mirrors and interleaves together two fiber Michelson interferometers that share the common-interferometric-optical path, is presented. One of the fiber interferometers is used to stabilise the system by the use of an electronic feedback loop to compensate the influences resulting from the environmental disturbances, while the other one is used to perform the measurement task. The influences resulting from the environmental disturbances have been eliminated by the compensating action of the electronic feedback loop, this makes the system suitable for on-line precision measurement. By means of the homodyne phase-tracking technique, the linearity of the measurement results of displacement measurements has been very high.
Resumo:
A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.
Resumo:
A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.
Resumo:
Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. © 2013 Paolo Bifulco et al.
Resumo:
A validation study examined the accuracy of a purpose-built single photon absorptiometry (SPA) instrument for making on-farm in vivo measurements of bone mineral density (BMD) in tail bones of cattle. In vivo measurements were made at the proximal end of the ninth coccygeal vertebra (Cy9) in steers of two age groups (each n = 10) in adequate or low phosphorus status. The tails of the steers were then resected and the BMD of the Cy9 bone was measured in the laboratory with SPA on the resected tails and then with established laboratory procedures on defleshed bone. Specific gravity and ash density were measured on the isolated Cy9 vertebrae and on 5-mm2 dorso-ventral cores of bone cut from each defleshed Cy9. Calculated BMD determined by SPA required a measure of tail bone thickness and this was estimated as a fraction of total tail thickness. Actual tail bone thickness was also measured on the isolated Cy9 vertebrae. The accuracy of measurement of BMD by SPA was evaluated by comparison with the ash density of the bone cores measured in the laboratory. In vivo SPA measurements of BMD were closely correlated with laboratory measurements of core ash density (r = 0.92). Ash density and specific gravity of cores, and all SPA measures of BMD, were affected by phosphorus status of the steers, but the effect of steer age was only significant (P < 0.05) for steers in adequate phosphorus status. The accuracy of SPA to determine BMD of tail bone may be improved by reducing error associated with in vivo estimation of tail bone thickness, and also by adjusting for displacement of soft tissue by bone mineral. In conclusion a purpose-built SPA instrument could be used to make on-farm sequential non-invasive in vivo measurements of the BMD of tailbone in cattle with accuracy acceptable for many animal studies.
Resumo:
A range of influences, technical and organizational, has encouraged the wide spread adaption of Enterprise Systems (ES). Nevertheless, there is a growing consensus that Enterprise Systems have in the many cases failed to provide the expected benefits to organizations. This paper presents ongoing research, which analyzes the benefits realization approach of the Queensland Government. This approach applies a modified Balance Scorecard. First, history and background of Queensland Government’s Enterprise Systems initiative is introduced. Second, the most common reasons for ES under performance are related. Third, relevant performance measurement models and the Balanced Scorecard in particular are discussed. Finally, the Queensland Government initiative is evaluated in light of this overview of current work in the area. In the current and future work, the authors aim to use their active involvement in Queensland Government’s benefits realization initiative for an Action Research based project investigating the appropriateness of the Balanced Scorecard for the purposes of Enterprise Systems benefits realization.