984 resultados para Multi-detector Computed Tomography
Resumo:
Impaction of permanent teeth represents a clinical challenge with regard to diagnosis, treatment plan, and prognosis. There is a close relationship between deciduous teeth and permanent teeth germ, and any injury in the deciduous dentition may influence the permanent teeth eruption. The extent of the damage caused to the permanent teeth germ depends on the patient age at the time of injury, type of trauma, severity, and direction of the impact. Conventional radiographic images are frequently used for diagnosis; however, recent developments in three-dimensional (3D) imaging systems have enabled dentistry to visualize structural changes effectively, with better contrast and more details, close to the reality. The cone-beam computed tomography (CBCT) has been used in the diagnosis and treatment plan of these impacted teeth. The purpose of the present case report is to describe a successful conservative management of a retained permanent maxillary lateral incisor with delayed root development after a trauma through the deciduous predecessor in a 9 year-old patient. After clinical and radiographic examination, a CBCT examination of the maxilla was requested to complement the diagnosis, providing an accurate 3D position of the retained tooth and its relationship to adjacent structures. The proposed treatment plan was the surgical exposure and orthodontic traction of the retained tooth. The lateral incisor spontaneously erupted after 6 months. Therefore, this case report suggests that permanent teeth with incomplete root formation have a great potential for spontaneous eruption because no tooth malposition or mechanical obstacles are observed.
Resumo:
Variations in jaw bone neurovascularisation must be identified to decrease the potential risk for haemorrhages and neural disturbances during surgical procedures such as implant placement and orthognatic surgeries. The aim of this study is to characterise additional mental foramina (AMF) through cone beam computed tomography (CBCT) images, by describing their frequency, size, location and direction of their associated bony canals, as well as to assess their corresponding ipsilateral and contralateral mental foramina (MF). CBCT images from 285 patients were analysed. Prevalence of AMF was 9.4%. From 0 to 2 AMF were observed, with two bilateral cases. Two cases of unilateral absence of MF were registered. Patients presenting AMF did not differ significantly from those without AMF regarding gender, age or ethnicity. Diameters of AMF and their corresponding ipsilateral and contralateral MF were 1.9 mm (+/- 0.7 mm), 3.8 mm (+/- 0.6 mm) and 4.1 mm (+/- 0.6 mm), respectively. Ratios between diameters of AMF and corresponding ipsilateral MF ranged between 0.24 and 0.99. Location of AMF was variable, with most cases located posteriorly, posterior-inferiorly, posterior-superiorly or anterior-superiorly to their respective MF. Significant anatomical variability regarding neurovascularisation was observed among patients and CBCT examinations presented as a valuable tool for individually assessing these anatomical features.
Resumo:
Osny Ferreira-Junior, Luciana Dorigatti de Avila, Marcelo Bonifacio da Silva Sampieri, Eduardo Dias-Ribeiro, Weiliang Chen, Song Fan. Impacted Lower Third Molar Fused with a Supernumerary Tooth-Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography. International Journal of Oral Science, 1(4): 224-228, 2009 This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radiography was complemented by the Donovan`s radiographic technique; but because of the proximity of the dental element to the mandibular ramus, it was not possible to have a final fusion diagnosis. Hence, the Cone-Beam Computed Tomography-which provides precise three-dimensional information-was used to determinate the fusion diagnosis and also to help in the surgical planning. In this case report we observed that the periapical, occlusal and panoramic were not able to show details which could only be examined through the cone-beam computed tomography.
Resumo:
Introduction: The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. Methods: Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geometry were compared with preoperative values. Data were compared by independent sample t test and chi(2) test between groups and paired sample t test within the group (alpha = 0.05). Results: Overall, area, perimeter, roundness, and major and minor diameters revealed no statistical difference between groups (P > .05). In the coronal third, percentage of prepared root canal walls and mean increases of volume and area were significantly higher with SAF (92.0%, 1.44 +/- 0.49 mm(3), 0.40 +/- 0.14 mm(2), respectively) than rotary instrumentation (62.0%, 0.81 +/- 0.45 mm(3), 0.23 +/- 0.15 mm2, respectively) (P < .05). SAF removed dentin layer from all around the canal, whereas rotary instrumentation showed substantial untouched areas. Conclusions: In the coronal third, mean increases of area and volume of the canal as well as the percentage of prepared walls were significantly higher with SAF than with rotary instrumentation. By using SAF instruments, flat-oval canals were homogenously and circumferentially prepared. The size of the SAF preparation in the apical third of the canal was equivalent to those prepared with #40 rotary file with a 0.02 taper. (J Endod 2011;37:1002-1007)
Resumo:
P>Aim To investigate the internal and external anatomy of extracted human mandibular canines with two roots and two distinct canals using micro-computed tomography (mu CT). Methodology Fourteen two-rooted human mandibular canines were scanned using a high-resolution mu CT system (SkyScan 1174v2; SkyScan N.V., Kontich, Belgium). The images were processed to evaluate the size of the roots, the furcation regions, the presence of accessory canals, the mean distances between several anatomical landmarks, the position of the apical foramina, the direction of root curvatures, the cross-sectional appearances (SMI index), the volume and surface areas of the root canals. Results Root bifurcation was located in both apical (44%, n = 6) and middle (58%, n = 8) thirds of the root. The size of the buccal and lingual roots was similar in 29% of the sample. From a buccal view, no curvature towards the lingual or buccal direction occurred in either roots. From a proximal view, no straight lingual root occurred. In both views, S-shaped roots were found in 21% of the specimens. Location of the apical foramen varied considerably, tending to the mesio-buccal aspect of both roots. Lateral and furcation canals were observed mostly in the cervical third in 29% and 65% of the sample, respectively. The structure model index (SMI) index ranged from 1.87 to 3.86, with a mean value of 2.93 +/- 0.46. Mean volume and area of the root canals were 11.52 +/- 3.44 mm3 and 71.16 +/- 11.83 mm2, respectively. Conclusions The evaluation of two-rooted mandibular canines revealed that bifurcations occurred in the apical and middle third. S-shaped roots were found in 21% of the specimens. Mean volume, surface area and SMI index of the root canals were 11.52 mm3, 71.16 mm2 and 2.93, respectively.
Resumo:
The purpose of this study was to evaluate a new periapical index based on cone beam computed tomography (CBCT) for identification of apical periodontitis (AP). The periapical index proposed in this study (CBCTPAI) was developed on the basis of criteria established from measurements corresponding to periapical radiolucency interpreted on CBCT scans. Radiolucent images suggestive of periapical lesions were measured by using the working tools of Planimp software on CBCT scans in 3 dimensions: buccopalatal, mesiodistal, and diagonal. The CBCTPAI was determined by the largest lesion extension. A 6-point (0-5) scoring system was used with 2 additional variables, expansion of cortical bone and destruction of cortical bone. A total of 1014 images (periapical radiographs and CBCT scans) originally taken from 596 patients were evaluated by 3 observers by using the CBCTPAI criteria. AP was identified in 39.5% and 60.9% of cases by radiography and CBCT, respectively (P<.01). The CBCTPAI offers an accurate diagnostic method for use with high-resolution images, which can reduce the incidence of false-negative diagnosis, minimize observer interference, and increase the reliability of epidemiologic studies, especially those referring to AP prevalence and severity. (J Endod 2008;34:1325-1331)
Resumo:
Eight patients with heterozygous familial hypercholesterolemia who received combined long-term low-density lipoprotein apheresis and high-dose statin therapy showed a significant decrease in volume of coronary calcium over a period of 29 months as measured by, computed tomography. This suggests that the effects of aggressive lipid-lowering therapy can be assessed non-invasively and may be used as surrogate end points when testing new therapies.
Resumo:
Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações
Resumo:
Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semiautomated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developingCADto be predicted will be presented. A64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
Resumo:
OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used.RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively.CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.
Resumo:
Marked regional variations in myocardial activity that are not related to myocardial perfusion defects.Verify the influence of CT-AC inMPI results in patients with BMI between 30 and 35 and higher than 30 for male and female population.
Resumo:
OBJECTIVE: Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. METHODS: All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore & Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related adverse events. Multivariable Cox regression was used to test postoperative CTA characteristics as independent risk factors, which were subsequently used as selection criteria for low-risk and high-risk groups. Estimates for freedom from adverse events were obtained using Kaplan-Meier survival curves. RESULTS: Included were 131 patients. The median follow-up was 4.1 years (interquartile range, 2.1-6.1). During this period, 30 patients (23%) sustained aneurysm-related adverse events. Seal length <10 mm and presence of endoleak were significant risk factors for this end point. Patients were subsequently categorized as low-risk (proximal and distal seal length ≥10 mm and no endoleak, n = 62) or high-risk (seal length <10 mm or presence of endoleak, or both; n = 69). During follow-up, four low-risk patients (3%) and 26 high-risk patients (19%) sustained events (P < .001). Four secondary interventions were required in three low-risk patients, and 31 secondary interventions in 23 high-risk patients. Sac growth was observed in two low-risk patients and in 15 high-risk patients. The 5-year estimates for freedom from aneurysm-related adverse events were 98% for the low-risk group and 52% for the high-risk group. For each diagnosis, 81.7 image examinations were necessary in the low-risk group and 8.2 in the high-risk group. CONCLUSIONS: Our results suggest that the first postoperative CTA provides important information for risk stratification after endovascular aneurysm repair when the Excluder endoprosthesis is used. In patients with adequate seal and no endoleaks, the risk of aneurysm-related adverse events was significantly reduced, resulting in a large number of unnecessary image examinations. Adjusting the imaging protocol beyond 30 days and up to 5 years, based on individual patients' risk, may result in a more efficient and rational postoperative surveillance.