952 resultados para Modular simulators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: The degree of conservation of gene expression between homologous organs largely remains an open question. Several recent studies reported some evidence in favor of such conservation. Most studies compute organs' similarity across all orthologous genes, whereas the expression level of many genes are not informative about organ specificity. RESULTS: Here, we use a modularization algorithm to overcome this limitation through the identification of inter-species co-modules of organs and genes. We identify such co-modules using mouse and human microarray expression data. They are functionally coherent both in terms of genes and of organs from both organisms. We show that a large proportion of genes belonging to the same co-module are orthologous between mouse and human. Moreover, their zebrafish orthologs also tend to be expressed in the corresponding homologous organs. Notable exceptions to the general pattern of conservation are the testis and the olfactory bulb. Interestingly, some co-modules consist of single organs, while others combine several functionally related organs. For instance, amygdala, cerebral cortex, hypothalamus and spinal cord form a clearly discernible unit of expression, both in mouse and human. CONCLUSIONS: Our study provides a new framework for comparative analysis which will be applicable also to other sets of large-scale phenotypic data collected across different species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. METHODS: Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam (Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. RESULTS: Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O gerenciamento de informação pode ser identificado como desafio crucial, sobretudo no tocante aos conteúdos de websites e sistemas de informação em ambiente web. Assim, o desenvolvimento de meios e métodos para gerenciamento de conteúdos é tema deste artigo, o qual objetiva, através de um relato de aplicação de pesquisa participativa, apresentar a descrição funcional de um sistema modular para gerenciamento de conteúdos em ambiente web. São discutidos aspectos relacionados com o desenvolvimento do sistema e sua aplicação em 28 websites. Adicionalmente, é apresentada uma avaliação quantitativa com base na satisfação, facilidade de uso percebida, freqüência de uso e importância dos módulos que o compõem. Entre os principais resultados, aponta-se a evidência da flexibilidade da proposta modular e a constatação de que os gestores se mostraram satisfeitos com o sistema, não apresentando dificuldade de uso e obtendo resultados positivos com o uso da ferramenta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research, initiated in October 1992, was located at the intersection of Blairs Ferry Road and Lindale Drive in the City of Marion. The wall is located on the southeast corner of the intersection. Reinforced retaining wall construction started with a five inch base of roadstone with one inch of sand for leveling purposes. One and one-half to two feet of one inch clean stone was placed behind the blocks. A four inch perforated plastic pipe was placed approximately nine inches from the bottom of the one inch clean stone. The Tenswal, tensar geogrid was placed at every third layer. Openings in the Tenswal are hooked over plastic dowels in the blocks. The tenswal reaches from the face of the wall back 5' to 8'. The cost for constructing this wall was $124,400. The wall has performed well for the past five years. The wall improves the aesthetics of a high traffic volume intersection of an urban area. Many positive comments have been received by the city regarding its appearance. The City of Marion has been pleased with the wall and has used this type of wall on subsequent projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of my PhD research was the concept of modularity. In the last 15 years, modularity has become a classic term in different fields of biology. On the conceptual level, a module is a set of interacting elements that remain mostly independent from the elements outside of the module. I used modular analysis techniques to study gene expression evolution in vertebrates. In particular, I identified ``natural'' modules of gene expression in mouse and human, and I showed that expression of organ-specific and system-specific genes tends to be conserved between such distance vertebrates as mammals and fishes. Also with a modular approach, I studied patterns of developmental constraints on transcriptome evolution. I showed that none of the two commonly accepted models of the evolution of embryonic development (``evo-devo'') are exclusively valid. In particular, I found that the conservation of the sequences of regulatory regions is highest during mid-development of zebrafish, and thus it supports the ``hourglass model''. In contrast, events of gene duplication and new gene introduction are most rare in early development, which supports the ``early conservation model''. In addition to the biological insights on transcriptome evolution, I have also discussed in detail the advantages of modular approaches in large-scale data analysis. Moreover, I re-analyzed several studies (published in high-ranking journals), and showed that their conclusions do not hold out under a detailed analysis. This demonstrates that complex analysis of high-throughput data requires a co-operation between biologists, bioinformaticians, and statisticians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El proyecto consiste en la realización de una agenda web modular, utilizando para ello las tecnologías de la plataforma J2EE mediante frameworks (Hibernate y Spring) y un patrón de arquitectura (MVC). La agenda se ha realizado para ser gestionada por un servidor Apache Tomcat y sus datos almacenados en MySQL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is increasing evidence that modular neck stems are prone to corrosion-related complications. Recent studies showed elevated metal ions levels and occasional pseudotumor formation in patients with such implants. The purpose of this study was to compare systemic metal-ion levels in patients after primary THA with modular neck stems to those of patients after non-modular implants. To our knowledge, this is the first cohort study including a control group, THA without CoCr heads and dry-assembled neck-stem connections. Methods: 50 patients after THA at a minimum follow-up of 1 year have been selected for the study. Patients with multiple prosthesis or other implants have been deselected. All received a cementless SPS stem from Symbios (Ti6Al4V). 40 patients have the modular neck (CoCr) version and 10 a monobloc version. All bearings were either ceramic-ceramic or ceramic-polyethylene to minimize other sources of CoCr ion release. In the modular group, the neck was chosen pre-operatively based on a 3D planning, allowing for a dry assembly of the stem and neck on the back table before implantation. A plasma system coupled to mass spectrometry was used for a complete elementary quantification in blood and serum separately. Clinical outcome was measured using the Oxford Hip Score. Results : Complete data sets of 29 patients (24 in the modular neck-group (10male, mean age 63y, 35-84y) and 5 in the monobloc-group (3 male, 69 y, 51-83y) are available to date. Mean Co blood levels were .95 ug/L (.14-12.4) in the modular group vs .27 ug/L (.10-.73) in the monobloc group (p=.2). Respective values for Cr were significantly higher in the modular group (.99 g/L; range .75-1.21) compared to those in the monobloc group (.74 g/L ;.62-.86; p=.001). No significant difference was found when comparing serum levels. 5/24 patients had Co levels above 1 g/L (12/24 for Cr), which is by some considered as a relevant elevation. The maximum Co level was measured in an asymptomatic patient. The Oxford Hip Scores were similar in both groups. Conclusion: Cr levels were significantly elevated in the modular neck group compared to those in the monobloc group. 1/24 patients with a modular prosthesis exhibited Co levels, which are beyond the threshold accepted even for metal-on-metal bearing couples. These results have contributed to our decision to abandon the use of modular neck stems. Routine follow-up including annual measurements of systemic CoCr concentrations should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'objectiu principal del TFC consisteix en la creació d'una complexa estructura modular J2EE basada i mantinguda per Maven, amb la utilització com frameworks Spring, Hibernate i Flex principalment. Aquesta estructura permet reprendre el desenvolupament inicial, nous desenvolupaments i manteniments d'una aplicació, amb un cost temporal mínim per la part de l'equip de desenvolupament.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En aquest treball presentem una proposta d’avaluació per competències en una estructura modular que és fruit de la nostra experiència com a professors universitaris. Volem oferir un instrument d’avaluació conjunta per a tot l’equip de professors de mòdul que sigui vàlid, àgil i operatiu i que permeti donar feedback a cada estudiant del seu procés d’aprenentatge. Després de presentar els trets més singulars de la nostra institució i exposar alguns referents teòrics en relació a l’avaluació de competències, indiquem quines són les competències que hem seleccionat i aprofundim en la metodologia de treball i avaluació de les mateixes. Aquesta metodologia varia segons els espais acadèmics: gran grup, grup mig i seminari. A cadascun d’aquests espais es treballen i s’avaluen unes competències determinades, tot i que d’una forma més genèrica totes es desenvolupen conjuntament ens els tres àmbits. Considerem que és fonamental assenyalar que no es tracta d’avaluar “per assignatures” ni “per activitats”, sinó d’avaluar les competències que es desenvolupen a través de les matèries i de les propostes de treball que s’especifiquen en el pla docent.. L’ instrument d’avaluació que presentem possibilita la participació de tot el professorat implicat en el mateix mòdul i alhora permet que cada professor utilitzi els seus propis indicadors d’avaluació, aconseguint harmonitzar les dinàmiques de treball individuals i de grup.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Una eficaz acción educativa obliga necesariamente a plantearse en profundidad la autoevaluación como modelo de cambio y la participación de todos los estamentos de la comunidad educativa. Un mayor o menor grado de participación viene a ser un indicador que nos permite valorar cualquier propuesta de «calidad», «reforma» o «innovación». El modelo B.A.D.I. yen especial su instrumento modular, responde a las exigencias particulares de reflexión, análisis y toma de decisiones que se realiza en cada centro para responder adecuadamente a cualquier planteamiento innovador. Los principios fundamentales de este modelo se resumen en: A. Es un modelo de concepción organicista, estamental, con definición ideológica. B. Responde a un enfoque fundamentalmente rogeriano. C. Participa de los enfoques social, abierto, dinámico, cultural y positivo. Comparte la teoría moderna de la organización y sus indicadores se agrupan en cuatro fases: Criterial, presupuestaria, metodológica e informativa. D. Se identifica con los modelos centrados en la evaluación de cambio, de forma especial con la autoevaluación. La flexibilidad que caracteriza al modelo viene dado por el instrumento modular de área o de criterio, como resultado de la participación y el consenso de todos los estamentos de la institución educativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How proteins migrate through the interconnected organelles of the endolysosomal system is poorly understood. A piece of the puzzle has been added with the identification of a complex of tethering factors that functions in the recycling of proteins towards the cell surface.