136 resultados para Microchip
Resumo:
"Fluidic leakage" caused by vacuum force at the reversible sealing poly(dimethylsiloxane) (PDMS) interfaces was converted to one useable avenue, which led to formation of highly ordered surfactant microdroplets functionalized with ionic liquids (ILs). Vacuum force is the prerequisite to lead constant microsolutions to diffuse to the PDMS interfaces. Imidazolium ions of ILs rendered structural rearrangement of the surfactant aggregates and the ordered droplets formation.
Resumo:
Different effects of divalent metal ions on electrochemiluminescence (ECL) sensor with Ru(bPY)(3)(2+) immobilized in Eastman-AQ membrane were investigated. Mg2+,Ca2+ and Fe2+ can elevate the ECL of Ru(bpY)(3)(2+)/proline; while metal ions that underwent redox reactions on the electrode such as Mn2+ and Co2+ presented intensive quenching effects on Ru(bpy)(3)(2+) ECL. Also, the quenching effect of Mn2+ on the ECL sensor with Ru(bpY)(3)(2+) immobilized in Eastman-AQ membrane enhanced to about 30-folds compared with the case that Ru(bpy)(3)(2+) was dissolved in phosphate buffer, and the enhanced quenching effects of Mn2+ were studied.
Resumo:
For the first time, CEC was coupled with tris(2,2-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+) electrochemiluminescence detection. Efficient CEC separations of proline, putrescine, spermidine and spermine were achieved when the pH of the mobile phase is in the range of 3.5-7.0. The optimum mobile phase for CEC separation is much less acidic than that for CZE separation, which matches better with the optimum pH for Ru(bpy)(3)(2+) electrochemiluminescence detection and dramatically shortens the analysis time because of larger EOF at higher pH.
Resumo:
Among various ECL systems, such as 9,10-diphenylanthracene, lucigenin, tris(2,2'-bipyridyl) ruthenium, peroxyoxalate, luminol, graphene, and nanocrystals, Ru(bpy)(3)(2+) ECL is one of the most widely studied ECL systems in recent years due to its broad applications in immunoassays, DNA probe assays, coreactants analysis, and aptasensors. In this review, the progress in Ru(bpy)(3)(2+) ECL has been summarized on the whole, and the future research trends have been proposed.
Resumo:
A simultaneous electrochemiluminescence (ECL) and electrochemical (EC) detection scheme for NACE was presented for fast analysis of tertiary amines. Both ECL and EC signals were generated at the same Pt electrode. Triethylamine (TEA), tripropylamine (TPrA), chlorpromazine, promethazine, and dioxopromethazine (DPZ) were selected to validate NACE-ECL/EC dual detection strategy. The linear ranges for TEA and TPrA were 0.01-500 and 0.01-10 mu M with the detection limits of 8.0 and 5.0 nM (S/N=3), respectively. The RSDs (n = 6) of the migration time and the ECL intensity for 1 mu M TEA and 0.5 mu M TPrA were 0.1 and 2.8%, and 0.2 and 1.8% with theoretical plate numbers of 180 000 and 700 000 per meter, respectively. These two analytes could be separated within 92 s and the Pt electrode did not need reactivation during the experiments.
Resumo:
An effective electrochemiluminescence (ECL) sensor based on Nafion/poly(sodium 4-styrene sulfonate) (PSS) composite film-modified ITO electrode was developed. The Nafion/PSS/Ru composite film was characterized by atomic force microscopy, UV-vis absorbance spectroscopy and electrochemical experiments. The Nafion/PSS composite film could effectively immobilize tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) via ion-exchange and electrostatic interaction. The ECL behavior of Ru(bpy)(3)(2+) immobilized in Nafion/PSS composite film was investigated using tripropylamine (TPA) as an analyte. The detection limit (S/N = 3) for TPA at the Nafion/PSS/Ru composite-modified electrode was estimated to be 3.0 nM, which is 3 orders of magnitude lower than that obtained at the Nafion/Ru modified electrode. The Nafion/PSS/Ru composite film-modified indium tin oxide (ITO) electrode also exhibited good ECL stability. In addition, this kind of immobilization approach was simple, effective, and timesaving.
Resumo:
In this correspondence, we report on the first preparation of novel, robust Ru(bpy)(3)(2+)-containing supramolecular microstructures via a solution-based self-assembly strategy, carried out by directly mixing H2PtCl6 and Ru(bpy)(3)Cl-2 aqueous solutions at room temperature. It reveals that both the molar ratio and concentration of reactants have a heavy influence on the morphologies of such microstructures. The electrochemical behavior of the Ru(bpy)(3)(2+) components contained in the solid film of the microstructures formed on the electrode surface is also studied and found to exhibit a diffusion-controlled voltammetric feature. Most importantly, such microstructures exhibit excellent electrochemiluminescence (ECL) behaviors and therefore hold great promise as new luminescent materials for solid-state ECL detection in capillary electrophoresis (CE) or CE microchip.
Resumo:
Herein, homogenously partial sulfonation of polystyrene (PSP) was performed. An effective electrochemiluminescence (ECL) sensor based on PSP with carbon nanotube (CNTs) composite film was developed. Cyclic voltammetry and electrochemical impendence spectroscopy were applied to characterize this composite film. The PSP was used as an immobilization matrix to entrap the ECL reagent Ru(bpy)(3)(2+) due to the electrostatic interactions between sulfonic acid groups and Ru(bpy)(3)(2+) cations. The introduction of CNTs into PSP acted not only as a conducting pathway to accelerate the electron transfer but also as a proper matrix to immobilize Ru(bpy)(3)(2+) on the electrode by hydrophobic interaction. Furthermore, the results indicated the ECL intensity produced at this composite film was over 3-fold compared with that of the pure PSP film due to the electrocatalytic activity of the CNTs. Such a sensor was verified by the sensitive determinations of 2-(dibutylamino)ethanol and tripropylamine.
Resumo:
We developed an electrochemical detector on a hybrid chip for the determination of glucose in human plasma. The microchip system described in this paper consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate. The copper microelectrode is fabricated by selective electroless deposition. The fabrication of the decoupler is performed by platinum electrochemical deposition on the metal film formed by electroless deposition. Factors influencing the performance, including detection potential, separation field strength, and buffer concentration, were studied. The electrodes exhibited good stability and durability in the analytical procedures. Under optimized detection conditions, glucose responded linearly from 10 muM to 1 mM. Finally, glucose in human plasma from three healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.
Resumo:
The facile synthesis of the novel platinum nanoparticles/Eastman AQ55D/ruthenium(II) tris( bipyridine) (PtNPs/ AQ/Ru(bpy)(3)(2+)) colloidal material for ultrasensitive ECL solid-state sensors was reported for the first time. The cation ion-exchanger AQ was used not only to immobilize ECL active species Ru(bpy)(3)(2+) but also as the dispersant of PtNPs. Colloidal characterization was accomplished by transmission electron microscopy (TEM), X-ray photoelectron spectrum (XPS), and UV-vis spectroscopy. Directly coating the as-prepared colloid on the surface of a glassy carbon electrode produces an electrochemiluminescence (ECL) sensor. The electronic conductivity and electroactivity of PtNPs in composite film made the sensor exhibit faster electron transfer, higher ECL intensity of Ru(bpy)(3)(2+), and a shorter equilibration time than Ru(bpy)(3)(2+) immobilized in pure AQ film. Furthermore, it was demonstrated that the combination of PtNPs and permselective cation exchanger made the sensor exhibite excellent ECL behavior and stability and a very low limit of detection (1 x 10(-15) M) of tripropylamine with application prospects in bioanalysis. This method was very simple, effective, and low cost.
Resumo:
The work presented in this thesis described the development of low-cost sensing and separation devices with electrochemical detections for health applications. This research employs macro, micro and nano technology. The first sensing device developed was a tonerbased micro-device. The initial development of microfluidic devices was based on glass or quartz devices that are often expensive to fabricate; however, the introduction of new types of materials, such as plastics, offered a new way for fast prototyping and the development of disposable devices. One such microfluidic device is based on the lamination of laser-printed polyester films using a computer, printer and laminator. The resulting toner-based microchips demonstrated a potential viability for chemical assays, coupled with several detection methods, particularly Chip-Electrophoresis-Chemiluminescence (CE-CL) detection which has never been reported in the literature. Following on from the toner-based microchip, a three-electrode micro-configuration was developed on acetate substrate. This is the first time that a micro-electrode configuration made from gold; silver and platinum have been fabricated onto acetate by means of patterning and deposition techniques using the central fabrication facilities in Tyndall National Institute. These electrodes have been designed to facilitate the integration of a 3- electrode configuration as part of the fabrication process. Since the electrodes are on acetate the dicing step can automatically be eliminated. The stability of these sensors has been investigated using electrochemical techniques with excellent outcomes. Following on from the generalised testing of the electrodes these sensors were then coupled with capillary electrophoresis. The final sensing devices were on a macro scale and involved the modifications of screenprinted electrodes. Screen-printed electrodes (SPE) are generally seen to be far less sensitive than the more expensive electrodes including the gold, boron-doped diamond and glassy carbon electrodes. To enhance the sensitivity of these electrodes they were treated with metal nano-particles, gold and palladium. Following on from this, another modification was introduced. The carbonaceous material carbon monolith was drop-cast onto the SPE and then the metal nano-particles were electrodeposited onto the monolith material
Resumo:
We study the generation of supercontinua in air-silica microstructured fibers by both nanosecond and femtosecond pulse excitation. In the nanosecond experiments, a 300-nm broadband visible continuum was generated in a 1.8-m length of fiber pumped at 532 nm by 0.8-ns pulses from a frequency-doubled passively Q-switched Nd:YAG microchip laser. At this wavelength, the dominant mode excited under the conditions of continuum generation is the LP 11 mode, and, with nanosecond pumping, self-phase modulation is negligible and the continuum generation is dominated by the interplay of Raman and parametric effects. The spectral extent of the continuum is well explained by calculations of the parametric gain curves for four-wave mixing about the zero-dispersion wavelength of the LP11 mode. In the femtosecond experiments, an 800-nm broad-band visible and near-infrared continuum has been generated in a 1-m length of fiber pumped at 780 nm by 100-fs pulses from a Kerr-lens model-locked Ti:sapphire laser. At this wavelength, excitation and continuum generation occur in the LP01 mode, and the spectral width of the observed continuum is shown to be consistent with the phase-matching bandwidth for parametric processes calculated for this fiber mode. In addition, numerical simulations based on an extended nonlinear Schrödinger equation were used to model supercontinuum generation in the femtosecond regime, with the simulation results reproducing the major features of the experimentally observed spectrum. © 2002 Optical Society of America.
Resumo:
A hydrodynamic characterization of an industrially used gas-liquid contacting microchannel. device is discussed, viz. the micro bubble column of IMM. Furthermore, similar characterization of a gas-liquid flow microchip of TU/e, with two tailored mixer designs, is used to solve fundamental issues on hydrodynamics, and therefore, to achieve further design and operating optimization of that chip and the IMM device. Flow pattern maps are presented in a dimensionless fashion for further predictions on new fluidic systems for optimum single-channel multiphase operation. Bubble formation was investigated in the two types of mixers and pinch-off and hydrodynamic decay mechanisms are observed. The impact of these mechanisms on bubble size, bubble size distributions, and on the corresponding flow patterns, i.e., the type of mixer design, can be decisive for the flow pattern map and thus, may be used to alter flow pattern maps. The bubble sizes and their distribution were improved for the tailored designs, i.e., smaller and more regular bubbles were generated. Finally, the impact of multi-channel distribution for gas and liquid flow is demonstrated. Intermediate flow patterns such as slug-annular flow, also found for single-phase operation, and the simultaneous coexistence of flow regimes are presented, with the latter providing evidence of flow maldistribution.
Resumo:
Les études génétiques, telles que les études de liaison ou d’association, ont permis d’acquérir une plus grande connaissance sur l’étiologie de plusieurs maladies affectant les populations humaines. Même si une dizaine de milliers d’études génétiques ont été réalisées sur des centaines de maladies ou autres traits, une grande partie de leur héritabilité reste inexpliquée. Depuis une dizaine d’années, plusieurs percées dans le domaine de la génomique ont été réalisées. Par exemple, l’utilisation des micropuces d’hybridation génomique comparative à haute densité a permis de démontrer l’existence à grande échelle des variations et des polymorphismes en nombre de copies. Ces derniers sont maintenant détectables à l’aide de micropuce d’ADN ou du séquençage à haut débit. De plus, des études récentes utilisant le séquençage à haut débit ont permis de démontrer que la majorité des variations présentes dans l’exome d’un individu étaient rares ou même propres à cet individu. Ceci a permis la conception d’une nouvelle micropuce d’ADN permettant de déterminer rapidement et à faible coût le génotype de plusieurs milliers de variations rares pour un grand ensemble d’individus à la fois. Dans ce contexte, l’objectif général de cette thèse vise le développement de nouvelles méthodologies et de nouveaux outils bio-informatiques de haute performance permettant la détection, à de hauts critères de qualité, des variations en nombre de copies et des variations nucléotidiques rares dans le cadre d’études génétiques. Ces avancées permettront, à long terme, d’expliquer une plus grande partie de l’héritabilité manquante des traits complexes, poussant ainsi l’avancement des connaissances sur l’étiologie de ces derniers. Un algorithme permettant le partitionnement des polymorphismes en nombre de copies a donc été conçu, rendant possible l’utilisation de ces variations structurales dans le cadre d’étude de liaison génétique sur données familiales. Ensuite, une étude exploratoire a permis de caractériser les différents problèmes associés aux études génétiques utilisant des variations en nombre de copies rares sur des individus non reliés. Cette étude a été réalisée avec la collaboration du Wellcome Trust Centre for Human Genetics de l’University of Oxford. Par la suite, une comparaison de la performance des algorithmes de génotypage lors de leur utilisation avec une nouvelle micropuce d’ADN contenant une majorité de marqueurs rares a été réalisée. Finalement, un outil bio-informatique permettant de filtrer de façon efficace et rapide des données génétiques a été implémenté. Cet outil permet de générer des données de meilleure qualité, avec une meilleure reproductibilité des résultats, tout en diminuant les chances d’obtenir une fausse association.
Resumo:
En 2015, la récidive tumorale et les métastases du cancer du sein demeurent une cause importante de décès à travers le monde. Toutefois, ces cancers sont souvent hétérogènes car en dépit d’un phénotype similaire, l’évolution clinique et la réponse au traitement peuvent varier considérablement. Il y a donc un intérêt évident à identifier et à caractériser de nouveaux biomarqueurs pour permettre classer les tumeurs mammaires dans des sous-groupes plus homogènes. Notre hypothèse est que chaque cancer mammaire possède des caractéristiques distinctes au plan des altérations du génome et des profils d’expression géniques et que ces changements se traduisent cliniquement par une prédisposition à former des métastases ou à répondre ou non à la chimiothérapie et aux thérapies ciblées. Dans le cadre de nos travaux, nous nous sommes intéressés aux sous-types agressifs de tumeurs mammaires et notamment les cancers de type triple négatif. Nous avons aussi tenté d’identifier des marqueurs capables de distinguer l’une de l’autre les tumeurs de type luminal A et luminal B. Pour ce faire, nous avons d’abord utilisé une stratégie in silico à partir de données publiques (micro-puces d’ADN et séquençage de l’ARN). Nous avons ensuite construit sept micro-matrices tissulaires (TMA) provenant de tissus mammaires normaux et tumoraux fixés à la formaline et enrobés en paraffine. Ces outils nous ont permis d’évaluer par immunohistochimie les niveaux d’expression différentielle des marqueurs suivants : ANXA1, MMP-9, DP103 et MCM2. Ceux-ci ont été comparés aux marqueurs usuels du cancer du sein (ER, PR, HER2, CK5/6 et FOXA1) et corrélés aux données cliniques (survie globale et métastase). Nos résultats indiquent que ces nouveaux marqueurs jouent un rôle important dans l’évolution clinique défavorable des tumeurs de haut grade. Dans un premier article nous avons montré que l’expression d’ANXA1 est dérégulée dans les cancers de type triple-négatif et aussi, dans une certaine mesure, dans les tumeurs HER2+. Nous croyons qu’ANXA1 permet de mieux comprendre le processus d’hétérogénéité tumorale et facilite l’identification des tumeurs de haut grade. Nous proposons également qu’ d’ANXA1 stimule la transition épithélio-mésenchymateuse (EMT) et la formation des métastases. Dans un second temps, nous avons montré que les niveaux d’expression de MMP-9 reflètent la différenciation cellulaire et corrèlent avec les sous-types de cancers mammaires ayant un mauvais pronostic. Nous estimons que MMP-9 permet de mieux comprendre et d’identifier les tumeurs mammaires à haut risque. De fait, la surexpression de MMP-9 est associée à une augmentation des métastases, une récidive précoce et une diminution de la survie globale. Dans le cadre d’un troisième article, nous avons montré que la surexpression du marqueur de prolifération MCM2 s’observe dans les cancers triple-négatifs, HER2+ et Luminal B par comparaison aux cancers luminal A (p< 0.0001). Nos résultats suggèrent qu’en utilisant un seuil de 40% de noyaux marqués, nous pourrions distinguer l’une de l’autre les tumeurs de type luminal A et luminal B. Cela dit, avant de pouvoir envisager l’utilisation de ce marqueur en clinique, une étude de validation sur une nouvelle cohorte de patientes s’impose. En somme, les résultats de nos travaux suggèrent qu’ANXA1, MMP-9 et MCM2 sont des marqueurs intéressants pour mieux comprendre les mécanismes physiopathologiques impliqués dans la progression tumorale et le développement des métastases. À terme, ces nouveaux marqueurs pourraient être utilisés seuls ou en combinaison avec d’autres gènes candidats pour permettre le développement de trousses « multigènes » ou d’essais protéomiques multiplex pour prédire l’évolution clinique des cancers mammaires.