966 resultados para Membrane-covered self-expanding metal stent (SEMS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morbid obesity is an epidemic and complex disease which imposes a multidisciplinary approach. Laparoscopic sleeve gastrectomy has become a frequent procedure given its effi- cacy and safety compared to other surgical options. However, it isn’t free from complications. Lax gastric fixation or incorrect positioning of the stomach during surgery can result in early gastric outlet obstruction caused by a volvulus-like mechanism by rotation of the stomach around its anatomic axes. This report refers to two cases of post sleeve gastric torsion resulting in persisting vomiting after initiating oral intake. The diagnosis was confirmed by upper gastrointestinal-contrast study and gastroscopy. In both cases, a fully covered self-expandable metallic stentwas insertedwhich prompted the gastric lumen to become permeable resulting in symptomatic resolution. The stents were removed endoscopically aftertwo and three months. Beyond more than three years offollow-up,the patients remain asymptomatic and no recurring ‘‘stenosis’’ was noticed.In these cases the use offully covered self-expandable metallic stents demonstrated to be effective and safe in the treatment of post sleeve gastric torsion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new plastic self-expanding Smartcanula (Smartcanula LLC, Lausanne, Switzerland) is designed for central insertion and prevention of caval collapse. The objective of our work is to assess the influence of the new design on atrial chatter. Caval collapse over the entire caval axis, right atrial, hepatic, renal vein, and iliac vein is realized in drainage tubes with holes at 5 cm distance intervals. Smartcanulas with various lengths (26 cm [= right atrial], 34 cm [= hepatic], 43 cm [= renal], and 53 cm [= iliac]) versus two-stage cannulas are compared. Pressure drop (ΔP) is measured using Millar pressure-transducers. Flow rate (Q) is measured using an ultrasonic flow meter. Cannula resistance is defined as the ΔP/Q ratio. Data display and recording are controlled using LabView virtual instruments. At an 88 cm height differential, Q values are 8.69 and 6.8 l/min, and ΔP/Q ratios are 0.63 and 1.28 for the 26-cm Smartcanula and the reference cannula, respectively. The 34-cm Smartcanula showed 8.89 l/min and 0.6 ΔP/Q ratio vs. 7.59 l/min and 0.9 for the control cannula (P < 0.05). The 43-cm and 53-cm Smartcanulas showed Q values of 9.04 and 8.81 l/min, respectively, and ΔP/Q2 ratio of 0.6. The Smartcanula outperforms the two-stage cannula, and direct cannula insertion without guide wire is effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES In extreme scenarios, such as hyperacute rejection of heart transplant, an urgent heart explantation might be necessary. The aim of this experimental study was to determine the feasibility and to improve the haemodynamics of a venoarterial cardiopulmonary bypass after cardiectomy. METHODS A venoarterial cardiopulmonary bypass was established in seven calves (56.4 ± 7 kg) by the transjugular insertion to the caval axis of a self-expanding cannula, with a carotid artery return. After baseline measurements (A), ventricular fibrillation was induced (B), great arteries were clamped (C), the heart was excised and the right and left atria remnants, containing the pulmonary veins, were sutured together leaving an atrial septal defect over the cannula in the caval axis (D). Measurements were taken with the pulmonary artery clamped and declamped. RESULTS Initial pump flow was 4.16 ± 0.75 l/min dropping to 2.9 ± 0.63 l/min (P(AB )< 0.001) 10 min after induction of ventricular fibrillation. After cardiectomy with the pulmonary artery clamped, the pump flow increased non-significantly to 3.20 ± 0.78 l/min. After declamping, the flow significantly increased close to baseline levels (3.61 ± 0.73 l/min, P(DB )= 0.009, P(DC )= 0.017), supporting the notion that full cardiopulmonary bypass in acardia is feasible only if adequate drainage of pulmonary circulation is assured to avoid pulmonary congestion and loss of volume from the left-to-right shunt of bronchial vessels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS: Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS: Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION: Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The limitations of the medical management of symptomatic intracranial arterial stenosis encourage the development of new therapeutic strategies such as intracranial stenting. OBJECTIVE: To report and analyze the results of a series of 42 patients treated with 3 different endovascular techniques: isolated angioplasty, balloon-expandable coronary stents, and the Wingspan self-expandable intracranial stent system. METHODS: Forty-two patients presenting with symptomatic intracranial arterial stenosis were treated with one of these techniques. Computed tomography angiography was performed 6 months after the procedure, and the clinical neurological statuses were categorized using the modified Rankin Scale and the National Institutes of Health Stroke Scale. RESULTS: A total of 42 lesions were treated: 9 with isolated angioplasty, 14 with balloon-expandable coronary stents, and 19 with Wingspan self-expandable intracranial stents. The mean patient age was 62.9 years, and the mean arterial diameter stenosis was 73.9%. Technical success was achieved in 97.6% of the patients. The overall incidence of procedural complications was 21.4%, and the postoperative permanent morbidity/mortality rate was 7.1%. There were 3 cases of in-stent thrombosis (1 fatal) and 5 cases of asymptomatic restenosis (11.9%), 3 in the isolated angioplasty group and 2 in the Wingspan self-expandable intracranial stent group (mean follow-up 20.4 months). The rate of restenosis was higher in the angioplasty group (33%) than in the coronary (0%) and Wingspan stent (10.5%) groups. CONCLUSION: Endovascular treatment of symptomatic intracranial stenosis has significant overall morbidity and mortality rates. Nevertheless, the very critical natural history of severe refractory lesions and the relatively favorable postoperative evolution suggest that it should be considered the first alternative strategy in cases in which medical therapy has failed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: This study was carried out to evaluate surgical treatment of colorectal cancer (CRC) with special interest in present status and controversial issues: stenting as a palliative procedure for metastasized CRC (I), duration of thromboprophylaxis after the surgical treatment of CRC (II), treatment of the increasing population of elderly people (III) and the quality of life (QoL) after surgery for rectal cancer with special reference to pelvic floor dysfunction (IV). Materials and methods: The material consisted of patients with CRC operated on at Turku University Hospital between 2003 and 2008. In study II the data was collected retrospectively from electronic archives. In other studies the follow-up data was collected at postoperative control visits. In study IV the RAND-36 standardized questionnaire and additional questions assessing urinary, sexual and anorectal dysfunction were used. Results: The results of the current study showed that self-expanding metallic stents provided an alternative to palliative surgery in the treatment of obstructive CRC. Low molecular heparin given s.c. for a median of 11 days until hospital discharge seemed to provide sufficient thromboprophylaxis after surgery. With preoperative selection elderly patients with rectal cancer were suitable for major surgery for rectal cancer with morbidity and mortality rates comparable to those in younger patients. There was no difference between preoperative and one year postoperative general QoL for operated rectal cancer patients. Postoperative pelvic dysfunction was associated with an impaired QoL in some dimensions. Conclusions: Many individual factors regarding the patient and the disease must be taken into account when making treatment decisions in CRC to ensure successful treatment of CRC, patient satisfaction and QoL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: La disminución de flujo en los vasos coronarios sin presencia de oclusión, es conocido como fenómeno de no reflujo, se observa después de la reperfusión, su presentación oscila entre el 5% y el 50% dependiendo de la población y de los criterios diagnósticos, dicho suceso es de mal pronóstico, aumenta el riesgo de morir en los primeros 30 días posterior a la angioplastia (RR 2,1 p 0,038), y se relaciona con falla cardiaca y arritmias, por eso al identificar los factores a los cuales se asocia, se podrán implementar terapias preventivas. Metodología: Estudio de casos y controles pareado por médico que valoró el evento, para garantizar que no existieron variaciones inter observador, con una razón 1:4 (18:72), realizado para identificar factores asociados a la presencia de no reflujo en pacientes llevados a angioplastia, entre noviembre de 2010 y mayo de 2014, en la Clínica San Rafael de Bogotá, D.C. Resultados: La frecuencia del no reflujo fue del 2.89%. El Infarto Agudo de Miocardio con elevación del ST (IAMCEST) fue la única variable que mostró una asociación estadísticamente significativa con este suceso, valor de p 0,002, OR 8,7, IC 95% (2,0 – 36,7). Discusión: El fenómeno de no reflujo en esta población se comportó de manera similar a lo descrito en la literatura, siendo el IAMCEST un factor fuertemente asociado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Para realização do estudo microscópico das glândulas anexas à uretra masculina, foram utilizadas duas capivaras (Hydrochoerus hydrocaeris), adultas, das quais foram coletados fragmentos das glândulas genitais acessórias, imersos em solução fixadora de Bouin e lavados cuidadosamente em álcool de 70% ao absoluto. A seguir foram submetidos aos processos histológicos de rotina e corados pelos métodos de Hematoxilina/Eosina e Tricrômico de Masson. Os resultados morfológicos encontrados foram: o ducto deferente possui um espessamento da parede, onde a luz permanece inalterada e sem presença de epitélio granular. A glândula vesicular possui um epitélio secretor do tipo pseudoestratificado colunar. A glândula prostática possui mucosa com pregueamentos altos e ramificados, revestido por epitélio pseudoestratificado cilíndrico. Machos de capivaras possuem glândulas vesiculares e próstata como glândulas uretrais. No material examinado não foi identificado epitélio secretor correspondente a glândula bulbouretral e morfologicamente assemelha-se aos outros histricomorfos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research evaluated the bone repair process in surgical defects created on the parietal bones of diabetic rabbits using the guided bone regeneration technique to observe the effects of alloxan in the induction of diabetes mellitus. Twenty-four adult rabbits were divided into three study groups: control (C), diabetic (D) and diabetic associated to polytetrafluoroethylene (PTFE) membrane (D-PTFE). For diabetes induction the animals received one dose of monohydrated alloxan (90 mg/kg) by intravenous administration in the auricular or femoral vein. In group D-PTFE the membrane covered both the floor and the surface of the bone defect. In groups D and C, the bone defect was filled up with blood clot. The specimens were fixed in 10% formol and prepared for histomorphometric analysis. The results showed that the 90 mg/kg dose of monohydrate alloxan was sufficient to promote diabetes mellitus when administered in the auricular vein. Bone regeneration was slower in the diabetic group when compared with the control and diabetic-PTFE groups, but there was no significant statistical difference between the two experimental groups (D and D-PTFE). The oral and general clinical complications among the diabetics were weight loss, polyuria, polyphagia and severe chronic gingivitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 3f Enable aortic bioprosthesis (ATS Medical, Inc, Minneapolis, Minn) represents a new generation of equine pericardial self-expanding valve designed for sutureless implantation. This study evaluated technical aspects of implantation and safety and effectiveness of the valve in the short term.