999 resultados para Medicamentos (Controle de qualidade)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays the mammography is the most effective way of revealing early breast cancer. The image in this kind of exam is gotten trough a x-ray sheaf of low energy, however, the suitable visualization of the interesting structures by the radiologist is not always possible due several factors that appears since the mamma composition until the equipments limitation. The regulation 453/98 sets quality control tests and limits of acceptation that guarantee a good development of the mammographys. The purpose of this study is the 3D principle ( Diagnostic, Dose and Dollar), that means, an improved diagnosis, a dose reduction in the patient and a cost decrease for the Institution. In this study was made the quality control tests set by the Regulation in two mammography equipments from Hospital das Clínicas da Faculdade de Medicina de Botucatu (HCFMB - UNESP). The results reached in this research were used in the renovation process of quality stamp in mammography granted by Colégio Brasileiro de Radiologia (CBR) to the diagnosis by image from the HCFMB – UNESP

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O captopril foi o primeiro agente desenvolvido para o tratamento da hipertensão, doença que acomete grande parte da população adulta mundial, a qual requer cuidados especiais quanto à farmacoterapia e ajuste de doses. Assim sendo, este trabalho tem como objetivo avaliar a qualidade de comprimidos de captopril 50 mg comercializados no Brasil através da realização da equivalência farmacêutica entre duas marcas de comprimidos não revestidos de captopril 50 mg (um genérico G e um similar S) em relação ao medicamento referência (R) Capoten® Bristol Myers Squibb 50 mg, utilizando os requisitos descritos na monografia individual do fármaco da Farmacopeia Brasileira e da Farmacopeia Americana. Medicamentos referência são produtos inovadores, cuja eficácia, segurança e qualidade foram comprovadas cientificamente; os chamados similares são os que contêm as mesmas substâncias ativas, mesma concentração, forma farmacêutica, via de administração, posologia e indicação terapêutica do medicamento de referência e são identificados por nome comercial ou por sua marca; os medicamentos genéricos são intercambiáveis com o produto referência e, geralmente, são produzido após a expiração ou renúncia da proteção patentária do mesmo, ele deve ser designado pela DCB (Denominação Comum Brasileira) ou, na ausência desta, pela DCI (Denominação Comum Internacional). Os dois medicamentos analisados, medicamento similar e medicamento genérico, apresentaram resultados satisfatórios quanto à determinação de peso médio, resistência mecânica e tempo de desintegração dos comprimidos, identificação, doseamento, limite de dissulfeto de captopril, uniformidade de doses unitárias, teste de dissolução e perfil de dissolução do fármaco, com relação ao seu medicamento referência correspondente, ou seja, estes são equivalentes farmacêuticos e apresentam qualidade... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of a tumor with ionizing radiation is an ongoing process with well differentiated stages. These ones include the tumor diagnosis and location, the decision on the treatment strategy, the absorbed dose planning and calculation, the treatment administration, the absorbed dose verification and the evaluation of results in short and long terms. The quality of a radiotherapy procedure is closely linked to factors that may be classified as clinical, such as the diagnosis, the tumor location, the treatment strategy chosen and the continuous treatment reassessment; dosimetric or physical, such as the uncertainty in the dose calculation, its optimization and verification, the suitability of the equipment to provide a radiation beam consistent with the treatment planning; finally, others which are related to the practical application of radiotherapy treatment and the handling of the patient. In order to analyze the radiotherapy quality, one should realize that the three aspects (medical, physical or dosimetric and practical application) should be considered in a combined way. This means that numerous actions of the radiotherapists, medical physicists and technicians in radiotherapy should be held jointly and their knowledge level will significantly affect the treatment quality. In this study, the main physical parameters used in dosimetry are defined as well as determined experimentally for a linear accelerator Mevatron - MXT. With this, it is intended to provide recommendations for the physical aspects of Quality Assurance (QA) in the radiotherapy treatments, and these will usually be applied by professionals in Medical Physics. In addition to these instructions, it is recommended that additional texts are prepared to address in detail the clinical aspects of the treatments QA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Qualidade na coleta de dados do feixe de radiação, modelagem por meio do sistema de planejamento de tratamento (SPT) e controle da qualidade do processo envolvido são cruciais à fidedignidade do serviço de radioterapia de forma a contribuir à eficácia do tratamento e segurança do principal ente envolvido no final de toda essa sistemática, o paciente. Para isso foi proposto nesse presente trabalho a coleta de dados do feixe de raios-x de 6MV seguido da introdução desses dados ao SPT para processo de modelagem computacional que teve agregado, a todo esses processos, o controle da qualidade segundo critérios de aceitação

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is to control the quality of the structures, procedures for addressing the assembly of the formwork, scaffolding and the frame of pillars, beams and slabs. He had also intended to show that the vibration of launch and concrete items are also important, if poorly implemented can undermine the structure. This work also shows that the mapping becomes essential if there is some problem in the concrete, where concrete was launched, could be identified. And finally check the product where the structure will be evaluated for how much their quality

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Befor the vast economical growth and wild scientific and technological development, the companies are demanding, more and more qualification and acting of the services rendered by their employees. Like this, tasks are restricted the they be done with excellence, because the companies are always controlling the worker's development. They are several the tools used by the companies, as acting indexes to control the course of the worker's activities or certain section, integrations for new employees with the objective to present the line of work of the company so that the new employee is framed in these patterns, trainings offered for the employees to carry out their services with quality and compromising, evaluations of year end in order to test the worker's knowledge and to demand better results, finally, the companies hope the employee integrates normativamente into the reality of the company, in way to contribute for the atingimento of the organizational strategies, always collecting for this to obtain the best results and contribute to the growth of the company. This way, that research will present a tool of control of the total quality applied in a company in Rio Clearing's city and that it is managed by an educador. They will be verified the objectives that the company has in relationship a this control, the worker's subjectivity as participant subject of the tool of control of the System of Administration of the Quality and the worker's different glances before these aspects throught an interview.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)