490 resultados para Mechanic sutures


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work evaluated the effect of low doses of X-irradiation on the repairing process of sutured and nonsutured skin wounds in rats. For that, rats underwent a surgical proceedure, in which a 20 x 5-millimeter rectangular wound approximately 2-millimeter-deep was made in the dorsal region of each animal, and were divided in four groups: nonirradiated nonsutured; irradiated nonsutured ; nonirradiated sutured and irradiated sutured. The animals under irradiation were protected, during exposure, with a 2-millimeter-thick lead apron in such a way that only the incision was irradiated. Each animal was submitted to 18 seconds of exposure, undergoing a total of 7.4 rads. The evaluation of the effects of X-rays on the repairing process was carried out through microscopic observation by means of hematoxylin-eosin staining for morphological evaluation, and silver impregnation under polarized light for the observation of collagen synthesis. The results have shown that X-irradiation has caused delay in the repairing process, but it did not stop its development. The irradiated nonsutured group was considered to show the greater delay when compared with the other groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Craniosynostosis syndromes are characterized by premature closure of one or more cranial sutures, associated with other malformations, the most frequent of which are the Crouzon and Apert syndromes. Few studies in the literature have addressed the oral health of these individuals. The purpose of this study was to compare the periodontal status of individuals with Apert, Crouzon, Pfeiffer and Saethre-Chotzen syndromes before toothbrushing and compare the efficiency of plaque removal before and after mechanical toothbrushing. The probing depth, plaque index (according to Löe and O'Leary), clinical attachment level, gingival index (according to Silness and Löe) and amount of keratinized mucosa were evaluated before toothbrushing, and the O'Leary plaque index was assessed before and immediately after toothbrushing, on the same day, in 27 individuals aged 11 to 36 years. There was statistically significant difference in the mean probing depth and clinical attachment level among regions (p=0.00; p=0.01, respectively). The gingival index did not reveal statistically significant differences. With regard to the plaque index, the left region exhibited higher plaque index values than the right and anterior regions. No significant results were found in the analysis of keratinized mucosa. Comparison of the O'Leary plaque index before and after toothbrushing revealed statistically significant difference for all syndromes except for the Pfeiffer syndrome (p<0.05). In conclusion, there was no difference in the periodontal status among individuals with syndromic craniosynostosis. The posterior region was more affected than the anterior region as to the presence of plaque, loss of insertion and probing depth. Individuals with Pfeiffer syndrome exhibited greater toothbrushing efficiency than individuals with the other craniosynostosis syndromes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho estudou-se o desempenho mecânico e térmico de compostos de borracha natural (Hevea brasiliensis) de 4 diferentes clones (GT 1, IAN 873, PB 235 e RRIM 600) cultivados no Estado de São Paulo, assim como de uma mistura destes clones e de uma borracha comercial, GEB-1. Estas borrachas foram formuladas e vulcanizadas com tempos de 5, 7 e 9 minutos. A caracterização foi realizada por calorimetria exploratória diferencial, termogravimetria, ensaios de resistência à tração, análise dinâmico-mecânica, medidas de dureza Shore A, microscopia eletrônica de varredura e espectroscopia na região do infravermelho. Os resultados permitiram concluir que o tempo de vulcanização e o tipo de clone não influenciaram na temperatura de transição vítrea (Tg) dos compostos. Os valores de Tg obtidos por DMA foram de cerca de -62 °C, e os resultados ensaios de dureza apresentaram valores próximos de 60 para todos os compostos estudados. Os ensaios de resistência à tração mostraram que o melhor desempenho mecânico foi obtido pelo clone RRIM 600. De acordo com os resultados obtidos neste trabalho, todos os clones atingiram as propriedades reportadas na literatura, podendo ser utilizados, em princípio, nas indústrias de artefatos de borracha separadamente ou na forma de mistura.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemangiosarcoma is a common neoplasm in dogs and less frequently seen in cats. In nonhuman primates, this tumor is rarely reported. A 17 year-old female spider monkey (Ateles paniscus) was submitted an ultrasound exam due to gestation suspicion, which was seen a circular mass intra-uterine measuring 1.3 cm. New exams shown increase of the mass to 4.4 x 3.0 cm associated with a viable fetus. Was realized cesarean with ovariohysterectomy and excision of the mass; however the animal died in less than 24 hours after the surgery. In the necropsy, severe hemoabdomen was evidenced, although the surgical stumps were properly ligated and the complete sutures. Macroscopically, the uterine mass was soft, dark heterogeneous and measuring 5.0 cm in diameter. Histologically was visualized proliferation of spindle cells that form vascular channels replete of erythrocytes and some with thrombus, marked pleomorphism, nucleolus evident, binucleated cells and mitotic figures were rare. The immunohistochemistry (IHC) was performed, using streptavidin-biotin peroxidase technique (Dako Cytomation, USA) with the use of antibodies CD31 (clone JC/70A), CD34 (clone QB-END/10). The IHC showed a specific antigen-antibody reaction for CD31. According to localization, morphology and IHC, the present study reports a primary uterine hemangiosarcoma in a spider monkey that caused hemostatic abnormalities and consequent death of the animal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The corneal structure of three deep-sea species of teleosts (Gadiformes, Teleostei) from different depths (250-4000 m) and photic zones are examined at the level of the light and electron microscopes. Each species shows a similar but complex arrangement of layers with a cornea split into dermal and scleral components. The dermal cornea comprises an epithelium overlying a basement membrane and a dermal stroma with sutures and occasional keratocytes. Nezumia aequalis is the only species to possess a Bowman's layer, although it is not well-developed. The scleral cornea is separated from the dermal cornea by a mucoid layer and, in contrast to shallow-water species, is divided into three main layers; an anterior scleral stroma, a middle or iridescent layer and a posterior scleral stroma. The iridescent layer of collagen and intercalated cells or cellular processes is bounded by a layer of cells and the posterior scleral stroma overlies a Descemet's membrane and an endothelium. In the relatively shallow-water Microgadus proximus, the keratocytes of the dermal stroma, the cells of the iridescent layer and the endothelial cells all contain aligned endoplasmic reticulum, which may elicit an iridescent reflex. No alignment of the endoplasmic reticulum was found in N. aequalis or Coryphanoides (Nematonurus) armatus. The relative differences between shallow-water and deep-sea corneas are discussed in relation to the constraints of light, depth and temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite extensive research in the last 150 years, the regional tectonic reconstruction of the Western Alps has remained controversial. The curved orogenic belt consists of several ribbon-like continental terranes (Sesia/Austroalpine, Internal Crystalline Massifs, Brianconnais), which are separated by two or more ophiolitic sutures (Piemonte, Valais, Antrona?, Lanzo/ Canavese?). High-pressure (HP) metamorphism of each terrane occurred during distinct orogenic episodes: at similar to65 Ma in the Sesia/Austroalpine, at similar to45 Ma in the Piemonte zone and at similar to35 Ma in the Internal Crystalline Massifs. It is suggested that these events reflect individual accretionary episodes, which together with kinematic indicators and the speed and direction of plate motions, provide constraints for the discussed reconstruction model. The model involves a prolonged orogenic history that took place during relative convergence of Europe and Adria (here considered as a promontory of the African plate). The first accretionary event involved the Sesia/Austroalpine terrane. Final closure of the Piemonte Ocean occurred during the Eocene (similar to45 Ma) and involved ultra-high-pressure (UHP) metamorphism of the Piemonte oceanic crust. Incorporation of the Brianconnais terrane in the accretionary wedge occurred thereafter, possibly during or after subduction of the Valais Ocean in the late Eocene (45-35 Ma). This subduction was terminated at ca. 35 Ma, when the Internal Crystalline Massifs (i.e. the assumed internal parts of the Brianconnais terrane) were buried into great depths and underwent HP and UHP metamorphism. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AVFs may be considered the best type of venous access for chronic hemodialysis in pediatric patients with more than 20 kg who are not likely to receive a kidney transplant or be transitioned to peritoneal dialysis within one yr. The aim of the study was to report the experience in the creation of AVFs in pediatric candidates for renal transplantation using microsurgical vascular techniques, with emphasis on the details of the surgical technique. Forty children underwent 50 fistula creations - 31 radial-cephalic, 11 brachial-cephalic, five brachial-basilic and three saphenous-femoral. The vein was anastomosed to the artery in an end-to-lateral fashion by using two separate 8/0 prolene running sutures. The overall patency rate was 76.0%:22 (70.9%) of the radial-cephalic fistulas, nine (81.8%) of the brachial-cephalic, five (100.0%) of the brachial-basilic and two (66.6%) of the saphenous-femoral. There was no significant difference in patency rates between the brachial-cephalic, brachial-basilic and radial-cephalic fistulas. The incidences of fistula patency were not different for patients weighing < 20 kg compared with patients weighing > 20 kg. AVF remains as a satisfactory method for providing hemodialysis in children. The utilization of microsurgical techniques with some technical refinements described herein permits the achievement of high fistula patency rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Restoration of nerve continuity and effective maintenance of coaptation are considered fundamental principles of end-to-end peripheral nerve repair. OBJECTIVE: To evaluate the influence of the number of stitches on axonal regeneration and collagen production after neurorrhaphy. METHODS: Thirty male Wistar rats were equally divided into 3 groups and were all operated on with the right sciatic nerve exposed. In 2 groups, the nerve was sectioned and repaired by means of 3 (group B) or 6 (group C) epineurium sutures with 100 monofilament nylon. One group (group A) was used as a control. Each animal from groups B and C underwent electrophysiological evaluation with motor action potential recordings before nerve section and again at an 8-week interval after neurorrhaphy. Nerve biopsy specimens were used for histomorphometric assessment of axonal regeneration and quantification of collagen at the repair site. RESULTS: Animals from group C had significantly lower motor action potential conduction velocities compared with control animals (P = .02), and no significant difference was seen between groups B and C. Parameters obtained from morphometric evaluation were not significantly different between these 2 groups. Type I collagen and III collagen in the epineurium were significantly higher in group C than in either the control group (P = .001 and P = .003) or group B (P = .01 and P = .02). No differences were identified for collagen I and III in the endoneurium. CONCLUSION: Using 6 sutures for nerve repair is associated with worse electrophysiological outcomes and higher amounts of type I and III collagen in the epineurium compared with control. Neurorraphy with 6 stitches is also related to a significant increase in epineurium collagen I and III compared with 3-stitch neurorraphy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Since the first experiments with fibrin glue application in microvascular anastomoses in 1977, several studies have reported its benefits on suture reduction and anastomosis decreased time. In spite of that, clinical experience has been limited to two neurosurgical and two replantation case series, all of them with good results. This study was conducted to evaluate the feasibility and the potential benefits of fibrin glue application in free flaps. Methods: We performed 24 free flaps in 24 patients, from March 2005 to June 2006. Twenty were included in this study. They were divided into two groups according to the anastomosis technique: conventional group (n = 7 patients) and fibrin glue group (n = 13 patients). In the conventional group, the anastomosis was performed with interrupted sutures, whereas in the fibrin glue group, they were performed using less sutures and fibrin glue application. Results: The application of fibrin glue cut by half the number of sutures required to complete the anastomoses. The mean arterial and venous anastomotic times in the conventional group were 27.2 and 24.0 minutes, respectively. In the fibrin glue group, they were 13.6 and 12.6 minutes, respectively. All these differences were statistically significant. There was no significant difference of ischemic time between two groups (P = 0.26). The survival rate of the flaps was similar in both groups: 84.6% (11 of 13) in the fibrin glue group and 85.7% (6 of 7) in the conventional group (P = 1.0). Conclusions: Fibrin glue application in free flaps was feasible and allowed us to complete the anastomoses with fewer sutures and less time. The survival rate of the flaps was not adversely affected by the fibrin glue. (C) 2008 Wiley-Liss, Inc. Microsurgery 29:24-28, 2009.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To present the clinical and radiographic results of a case series of patients with acute acromioclavicular dislocation (MD) treated by arthroscopic coracoclavicular fixation with suture anchors. Method: Twenty patients with AAD with less than 30 days since the injury were submitted to a coracoclavicular stabilization procedure using 2 suture anchors placed at the base of the coracoid process. Each suture anchor was connected to 2 strands of No.2 nonabsorbable-braided sutures, which were passed through the holes drilled in the clavicle and tied to the upper surface of the clavicle. The coracoclavicular distance was measured and compared to the opposite side using radiographic evaluation. Constant and UCLA scores were used to determine clinical and functional evaluation after 6 months. Results: Of the initial twenty cases, six were submitted to a new surgical procedure and were excluded from the study. Of the fourteen patients remaining, only two maintained the initial reduction, while the remainder presented some degree of reduction loss. The Constant and UCLA score averages were 94.79 (82-100) and 32.64 (26-35) respectively. Conclusion: The technique had a high incidence of reduction loss after 6 months of follow up. The clinical and functional evaluation was satisfactory, with a high average score. Level of Evidence: Level III, retrospective study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cell therapy constitutes a possibility for improving nerve regeneration, increasing the success of nerve repair. We evaluate the use of mononuclear cells in the regeneration of the sciatic nerve after axotomy followed by end-to-end neurorrhaphy. Forty adult male Wistar rats (250300 g) were divided into four groups: (1) sham, (2) neurorrhaphy: the sciatic nerve was sectioned and repaired using epineural sutures, (3) culture medium: after the suture, received an injection of 10 mu L of culture medium into the nerve, and (4) mononuclear cell: after the suture, a concentration of 3 X 10(6) of mononuclear cell was injected in epineurium region. Mononuclear cells were obtained from the bone marrow aspirates and separated by Ficoll-Hypaque method. The histological analyses were performed at the 4th postoperative day. The sciatic functional index, histological, and morphometric analyzes were used to evaluate nerve regeneration at the 6th postoperative week. Six rats were used for immunohistochemical analysis on the 4th postoperative day. In the group 4, on the fourth day, the histological analysis demonstrated a more accelerated degenerative process and an increase of the neurotrophic factors was observed. In the 6th week, all the morphometric results of the group 4 were statistically better compared with groups 2 and 3. There was a statistically significant improvement in the sciatic functional index for group 4 compared with groups 2 and 3. Mononuclear cells stimulated nerve regeneration, most probably by speeding up the Wallerian degeneration process as well as stimulating the synthesis of neurotrophic factors. Microsc. Res. Tech. 74:355-363, 2011. (C) 2010 Wiley-Liss, Inc.