944 resultados para Measurement accuracy


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Indoor wireless network based client localisation requires the use of a radio map to relate received signal strength to specific locations. However, signal strength measurements are time consuming, expensive and usually require unrestricted access to all parts of the building concerned. An obvious option for circumventing this difficulty is to estimate the radio map using a propagation model. This paper compares the effect of measured and simulated radio maps on the accuracy of two different methods of wireless network based localisation. The results presented indicate that, although the propagation model used underestimated the signal strength by up to 15 dB at certain locations, there was not a signigicant reduction in localisation performance. In general, the difference in performance between the simulated and measured radio maps was around a 30 % increase in rms error

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. METHODS: After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. RESULTS: Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. CONCLUSIONS: Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Antiviral therapy can prevent disease progression in patients with chronic hepatitis C . Transient Elastografy (TE; Fibroscan) is an accurate surrogate marker to liver fibrosis, by measuring liver stiffness (LS). LS decrease has been associated with sustained virologic response (SVR). Aim: to assess the changes of LS measurments in CHC patients during and one year after Interferon (IFN)-based antiviral therapy (IFN/ribavirin) or (telaprevir+IFN/ribavirin). Methods: consecutive 69 CHC patients (53.6% females, mean age 57.9 ± 11.4) who underwent antiviral therapy for at least 20 weeks were enrolled. LS was measured using FibroScan at baseline, after three months, at the end of treatment and one year after treatment discontinuation. Fibrosis was graded using METAVIR score. Results: twenty patients treated with triple therapy and 49 with IFN/ribavirin. Fifty patients had SVR and 19 were non-responders. SVR patients: F0-F1, F2 and F3 patients (39.1%, 7.2% and 17.4%; respectively) showed no significant LS decrease (P= 0.186, 0.068 and 0.075; respectively). Conversely, in F4 patients (36.2%) LS was significantly decreased (P=0.015) after one year of treatment completion. In all patients with no SVR, no significant decrease in LS was observed. Interestingly, all Patients with F4 fibrosis (even non-responders) showed an initial significant decrease in LS (P=0.024) at 3 months after the start of treatment. However, this decrease was not predictive of SVR; area under the ROC curve 0.369 (CI %: 0.145-0.592) P= 0.265. Conclusion: Our study showed that initial decrease in LSM, especially in patients with higher baseline fibrosis score is unlikely to predict an SVR. In addition no significant association was found between clinical or virological parameters and fibrosis improvement. Further studies are needed to delineate the most appropriate clinical scenarios for the LSM by Fibroscan in chronic hepatitis C and its role in monitoring the response to antiviral treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Structural health monitoring (SHM) systems have excellent potential to improve the regular operation and maintenance of structures. Wireless networks (WNs) have been used to avoid the high cost of traditional generic wired systems. The most important limitation of SHM wireless systems is time-synchronization accuracy, scalability, and reliability. A complete wireless system for structural identification under environmental load is designed, implemented, deployed, and tested on three different real bridges. Our contribution ranges from the hardware to the graphical front end. System goal is to avoid the main limitations of WNs for SHM particularly in regard to reliability, scalability, and synchronization. We reduce spatial jitter to 125 ns, far below the 120 μs required for high-precision acquisition systems and much better than the 10-μs current solutions, without adding complexity. The system is scalable to a large number of nodes to allow for dense sensor coverage of real-world structures, only limited by a compromise between measurement length and mandatory time to obtain the final result. The system addresses a myriad of problems encountered in a real deployment under difficult conditions, rather than a simulation or laboratory test bed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Accuracy in the liquid hydrocarbons custody transfer is mandatory because it has a great economic impact. By far the most accurate meter is the positive displacement (PD) meter. Increasing such an accuracy may adversely affect the cost of the custody transfer, unless simple models are developed in order to lower the cost, which is the purpose of this work. PD meter consists of a fixed volume rotating chamber. For each turn a pulse is counted, hence, the measured volume is the number of pulses times the volume of the chamber. It does not coincide with the real volume, so corrections have to be made. All the corrections are grouped by a meter factor. Among corrections highlights the slippage flow. By solving the Navier-Stokes equations one can find an analytical expression for this flow. It is neither easy nor cheap to apply straightforward the slippage correction; therefore we have made a simple model where slippage is regarded as a single parameter with dimension of time. The model has been tested for several PD meters. In our careful experiments, the meter factor grows with temperature at a constant pace of 8?10?5?ºC?1. Be warned

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Productivity at the macro level is a complex concept but also arguably the most appropriate measure of economic welfare. Currently, there is limited research available on the various approaches that can be used to measure it and especially on the relative accuracy of said approaches. This thesis has two main objectives: firstly, to detail some of the most common productivity measurement approaches and assess their accuracy under a number of conditions and secondly, to present an up-to-date application of productivity measurement and provide some guidance on selecting between sometimes conflicting productivity estimates. With regards to the first objective, the thesis provides a discussion on the issues specific to macro-level productivity measurement and on the strengths and weaknesses of the three main types of approaches available, namely index-number approaches (represented by Growth Accounting), non-parametric distance functions (DEA-based Malmquist indices) and parametric production functions (COLS- and SFA-based Malmquist indices). The accuracy of these approaches is assessed through simulation analysis, which provided some interesting findings. Probably the most important were that deterministic approaches are quite accurate even when the data is moderately noisy, that no approaches were accurate when noise was more extensive, that functional form misspecification has a severe negative effect in the accuracy of the parametric approaches and finally that increased volatility in inputs and prices from one period to the next adversely affects all approaches examined. The application was based on the EU KLEMS (2008) dataset and revealed that the different approaches do in fact result in different productivity change estimates, at least for some of the countries assessed. To assist researchers in selecting between conflicting estimates, a new, three step selection framework is proposed, based on findings of simulation analyses and established diagnostics/indicators. An application of this framework is also provided, based on the EU KLEMS dataset.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recommendation for Oxygen Measurements from Argo Floats: Implementation of In-Air-Measurement Routine to Assure Highest Long-term Accuracy As Argo has entered its second decade and chemical/biological sensor technology is improving constantly, the marine biogeochemistry community is starting to embrace the successful Argo float program. An augmentation of the global float observatory, however, has to follow rather stringent constraints regarding sensor characteristics as well as data processing and quality control routines. Owing to the fairly advanced state of oxygen sensor technology and the high scientific value of oceanic oxygen measurements (Gruber et al., 2010), an expansion of the Argo core mission to routine oxygen measurements is perhaps the most mature and promising candidate (Freeland et al., 2010). In this context, SCOR Working Group 142 “Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders” (www.scor-int.org/SCOR_WGs_WG142.htm) set out in 2014 to assess the current status of biogeochemical sensor technology with particular emphasis on float-readiness, develop pre- and post-deployment quality control metrics and procedures for oxygen sensors, and to disseminate procedures widely to ensure rapid adoption in the community.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The Australian Women’s Activity Survey (AWAS) was developed based on a systematic review and qualitative research on how to measure activity patterns of women with young children (WYC). AWAS assesses activity performed across five domains (planned activities, employment, childcare, domestic responsibilities and transport), and intensity levels (sitting, light-intensity, brisk walking, moderate-intensity and vigorous-intensity) in a typical week in the past month. The purpose of this study was to assess the test-retest reliability and criterion validity of the AWAS. Methods: WYC completed the AWAS on two occasions 7-d apart (test-retest reliability protocol) and/or wore an MTI ActiGraph accelerometer for 7-d in between (validity protocol). Forty WYC (mean age 35 ± 5yrs) completed the test-retest reliability protocol and 75 WYC (mean age 33 ± 5yrs) completed the validity protocol. Interclass Correlation Coefficients (ICC) between AWAS administrations and Spearman’s Correlation Coefficients (rs) between AWAS and MTI data were calculated. Results: AWAS showed good test-retest reliability (ICC=0.80 (0.65-0.89)) and acceptable criterion validity (rs= 0.28, p=0.01) for measuring weekly health-enhancing physical activity. AWAS also provided repeatable and valid estimates of sitting time (test-retest reliability ICC=0.42 (0.13-0.64), and criterion validity (rs= 0.32, p=0.006)). Conclusion: The measurement properties of the AWAS are comparable to those reported for existing self-report measures of physical activity. However, AWAS offers a more comprehensive and flexible alternative for accurately assessing different domains and intensities of activity relevant to WYC. Future research should investigate whether the AWAS is a suitable measure of intervention efficacy by examining its sensitivity to change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knowledge of the accuracy of dose calculations in intensity-modulated radiotherapy of the head and neck is essential for clinical confidence in these highly conformal treatments. High dose gradients are frequently placed very close to critical structures, such as the spinal cord, and good coverage of complex shaped nodal target volumes is important for long term-local control. A phantom study is presented comparing the performance of standard clinical pencil-beam and collapsed-cone dose algorithms to Monte Carlo calculation and three-dimensional gel dosimetry measurement. All calculations and measurements are normalized to the median dose in the primary planning target volume, making this a purely relative study. The phantom simulates tissue, air and bone for a typical neck section and is treated using an inverse-planned 5-field IMRT treatment, similar in character to clinically used class solutions. Results indicate that the pencil-beam algorithm fails to correctly model the relative dose distribution surrounding the air cavity, leading to an overestimate of the target coverage. The collapsed-cone and Monte Carlo results are very similar, indicating that the clinical collapsed-cone algorithm is perfectly sufficient for routine clinical use. The gel measurement shows generally good agreement with the collapsed-cone and Monte Carlo calculated dose, particularly in the spinal cord dose and nodal target coverage, thus giving greater confidence in the use of this class solution.