923 resultados para Maxillofacial prosthesis implantation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A clinical investigation was undertaken to find out the prevalence of craniomandibular signs and symptoms in a group of 11 patients with labiopalatal lesions. The number and distribution of occlusal contacts was evaluated through questionnaire, clinical examination and analysis of mounted casts in partially adjustable articulators in the position of maximum inter cuspation. The most frequent signs and symptoms were articular sounds and lateral pterygoid muscle tenderness to palpation followed by restriction of mouth opening and sensation of tiredness. The number of occlusal contacts was small, mean of 5 contacts per patient, and the site was considered as atypical, 62% of them were on inclined plane surfaces , suggesting occlusal instability. The frequency of signs and symptoms was low and they were of a mild character. The most prevailing signs of craniomandibular dysfunction - articular sounds, muscular tenderness to palpation and restriction of mouth opening - was noticed in only one of the patients

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the Student t test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Maxillofacial deformities may cause awkward and embarrassing bearer. These patients present serious psychological, family and social issues becoming traumatized and complexed. These deformities can have congenital origin, malformations and developmental disorders, or can be caused by pathological mutilation such as necrotizing diseases and surgical oncology, or traumas such as traffic and work accidents.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery. Methods: Thirty Wistar white rats received subcutaneous implants ande the revestiment of silicone gel Silimed, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11 mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Results: Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Conclusion: In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivamos testar um novo modelo de endoprótese traqueal autoexpansível para que esse possa ser futuramente disponibilizado para o uso clínico. As endopróteses de nitinol revestidas de poliuretano foram alocadas no terço médio da traqueia de 25 coelhos da raça Nova Zelândia sob laringoscopia direta. Após um período de observação médio de 26 dias, avaliou-se a migração da prótese, grau de dilatação, incorporação, aderência, formação de tecido de granulação, presença de infiltrado inflamatório, envolvimento parietal e revestimento epitelial. Os resultados demonstraram completa expansibilidade radial, pouca aderência à mucosa traqueal e baixa incorporação tecidual, assim como alta taxas de formação de granulomas e de migração. Esse novo modelo demonstrou ser biocompatível e teve comportamento semelhante ao de outras próteses disponíveis no mercado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: A via de acesso transfemoral é preferencial para o implante por cateter de bioprótese valvar aórtica. Entretanto, algumas situações, como a presença de doença vascular periférica, impossibilitam a utilização desse acesso. Nesses casos, o acesso por dissecção da artéria subclávia é uma alternativa para a realização do procedimento. Nosso objetivo foi avaliar a experiência brasileira com a utilização da artéria subclávia como via de acesso para o implante por cateter da bioprótese CoreValve®. MÉTODOS: Foram requisitos para o procedimento área valvar aórtica < 1 cm², ânulo valvar aórtico ≥ 20 mm e ≤ 27 mm (CoreValve® de 26 mm e 29 mm), aorta ascendente ≤ 43 mm e artéria subclávia com diâmetro ≥ 6 mm, isenta de lesões obstrutivas significativas, tortuosidade acentuada e calcificação excessiva. O acesso pela artéria subclávia foi obtido por dissecção cirúrgica e, sob visão direta, punção da artéria subclávia. Obtido o acesso arterial, empregou-se a técnica padrão. RESULTADOS: Entre janeiro de 2008 e abril de 2012, 8 pacientes com doença vascular periférica foram submetidos a implante de prótese CoreValve® pela artéria subclávia em 4 instituições. O procedimento foi realizado com sucesso em todos os casos, com redução do gradiente transvalvar aórtico médio de 46,4 ± 17,5 mmHg para 9,3 ± 3,6 mmHg (P = 0,0018) e melhora dos sintomas. Aos 30 dias e no seguimento de 275 ± 231 dias, 87,5% e 62,5% dos pacientes, respectivamente, apresentavam-se livres de complicações maiores (óbito, infarto do miocárdio, acidente vascular cerebral e cirurgia cardíaca de urgência). CONCLUSÕES: Na experiência brasileira, o acesso pela artéria subclávia mostrou-se seguro e eficaz como via alternativa para o implante por cateter da bioprótese CoreValve®.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A successful interaction with objects in the environment requires integrating information concerning object-location with the shape, dimension and position of body parts in space. The former information is coded in a multisensory representation of the space around the body, i.e. peripersonal space (PPS), whereas the latter is enabled by an online, constantly updated, action-orientated multisensory representation of the body (BR) that is critical for action. One of the critical features of these representations is that both PPS and BR are not fixed, but they dynamically change depending on different types of experience. In a series of experiment, I studied plastic properties of PPS and BR in humans. I have developed a series of methods to measure the boundaries of PPS representation (Chapter 4), to study its neural correlates (Chapter 3) and to assess BRs. These tasks have been used to study changes in PPS and BR following tool-use (Chapter 5), multisensory stimulation (Chapter 6), amputation and prosthesis implantation (Chapter 7) or social interaction (Chapter 8). I found that changes in the function (tool-use) and the structure (amputation and prosthesis implantation) of the physical body elongate or shrink both PPS and BR. Social context and social interaction also shape PPS representation. Such high degree of plasticity suggests that our sense of body in space is not given at once, but it is constantly constructed and adapted through experience.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Renal failure after thoracoabdominal aortic repair is a significant clinical problem. Distal aortic perfusion for organ and spinal cord protection requires cannulation of the left femoral artery. In 2006, we reported the finding that direct cannulation led to leg ischemia in some patients and was associated with increased renal failure. After this finding, we modified our perfusion technique to eliminate leg ischemia from cannulation. In this article, we present the effects of this change on postoperative renal function. METHODS: Between February 1991 and July 2008, we repaired 1464 thoracoabdominal aortic aneurysms. Distal aortic perfusion was used in 1088, and these were studied. Median patient age was 68 years, and 378 (35%) were women. In September 2006, we began to adopt a sidearm femoral cannulation technique that provides distal aortic perfusion while maintaining downstream flow to the leg. This was used in 167 patients (15%). We measured the joint effects of preoperative glomerular filtration rate (GFR) and cannulation technique on the highest postoperative creatinine level, postoperative renal failure, and death. Analysis was by multiple linear or logistic regression with interaction. RESULTS: The preoperative GFR was the strongest predictor of postoperative renal dysfunction and death. No significant main effects of sidearm cannulation were noted. For peak creatinine level and postoperative renal failure, however, strong interactions between preoperative GFR and sidearm cannulation were present, resulting in reductions of postoperative renal complications of 15% to 20% when GFR was <60 mL>/min/1.73 m(2). For normal GFR, the effect was negated or even reversed at very high levels of GFR. Mortality, although not significantly affected by sidearm cannulation, showed a similar trend to the renal outcomes. CONCLUSION: Use of sidearm cannulation is associated with a clinically important and highly statistically significant reduction in postoperative renal complications in patients with a low GFR. Reduced renal effect of skeletal muscle ischemia is the proposed mechanism. Effects among patients with good preoperative renal function are less clear. A randomized trial is needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The appropriateness of rheumatic mitral valve repair remains controversial due to the risks of recurrent mitral dysfunction and need for reoperation. The aims of this study were to determine the overall short- and long-term outcomes of pediatric rheumatic mitral valve surgery in our center. METHODS: Single-center, observational, retrospective study that analyzed the results of rheumatic mitral valve surgery in young patients, consecutively operated by the same team, between 1999 and 2014. RESULTS: We included 116 patients (mean age = 12.6 ± 3.5 years), of which 66 (57%) were females. A total of 116 primary surgical interventions and 22 reoperations were performed. Primary valve repair was possible in 86 (74%) patients and valve replacement occurred in 30 (26%). Sixty percent of the patients were followed up beyond three months after surgery (median follow-up time = 9.2 months [minimum = 10 days; maximum = 15 years]). Long-term clinical outcomes were favorable, with most patients in New York Heart Association functional class I (89.6%) and in sinus rhythm (85%). Freedom from reoperation for primary valve repair at six months, five years, and ten years was 96.4% ± 0.25%, 72% ± 0.72%, and 44.7% ± 1.34%, respectively. Freedom from reoperation for primary valve replacement at six months, five years, and ten years was 100%, 91.7% ± 0.86%, and 91.7% ± 0.86%, respectively. Mitral stenosis as the primary lesion dictated early reintervention. CONCLUSIONS: Despite the greater rate of reoperation, especially when the primary lesion was mitral stenosis, rheumatic mitral valve repair provides similar clinical outcomes as compared with replacement, with the advantage of avoiding anticoagulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Currently, there are several techniques for the rehabilitation of atrophic maxillary ridges in literature. The grafting procedure using autogenous bone is considered ideal by many researchers, as it shows osteogenic capability and causes no antigenic reaction. However, this type of bone graft has some shortcomings, mainly the restricted availability of donor sites. In recent years, several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts, which are obtained from individuals with different genetic load, but from the same species, have been extensively used. They can be indicated in cases of arthroplasty, surgical knee reconstruction, large bone defects, and in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. on the other hand, allogeneic bone may have the disadvantage of transmitting infectious diseases. Atrophic maxillae can be treated with bone grafts followed by osseointegrated implants to obtain aesthetic and functional oral rehabilitation. This study aimed to show the viability of allogeneic bone grafting in an atrophic maxilla, followed by oral rehabilitation with dental implant and protocol-type prosthesis within a 3-year follow-up period by means of a clinical case report.