1000 resultados para Masse molaire des polymères


Relevância:

40.00% 40.00%

Publicador:

Resumo:

By definition, obesity corresponds to the presence of a mass of fatty tissue that is excessive with respect to the body mass. Body fat can be calculated in terms of age and sex by measuring the skinfold thickness in several different places. During the MONICA project, the survey of cardiovascular risk factor prevalence enabled us to measure the thickness of four skinfolds (biceps, triceps, subscapular, suprailiac) in 263 inhabitants of Lausanne (125 men, 138 women). In men aged 25-34, 21 +/- 5% of the body mass was composed of fat, in women 29 +/- 4%. The proportion of fat increases to 31 +/- 7% in men and 41 +/- 6% in women aged 55-64. A robust regression allows body fat to be simply expressed in terms of the body mass index. This allows us to confirm the validity of this index for evaluating the degree of obesity during an epidemiological study.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lorsque de l'essence est employée pour allumer et/ou propager un incendie, l'inférence de la source de l'essence peut permettre d'établir un lien entre le sinistre et une source potentielle. Cette inférence de la source constitue une alternative intéressante pour fournir des éléments de preuve dans ce type d'événements où les preuves matérielles laissées par l'auteur sont rares. Le but principal de cette recherche était le développement d'une méthode d'analyse de spécimens d'essence par GC-IRMS, méthode pas routinière et peu étudiée en science forensique, puis l'évaluation de son potentiel à inférer la source de traces d'essence en comparaison aux performances de la GC-MS. Un appareillage permettant d'analyser simultanément les échantillons par MS et par IRMS a été utilisé dans cette recherche. Une méthode d'analyse a été développée, optimisée et validée pour cet appareillage. Par la suite, des prélèvements d'essence provenant d'un échantillonnage conséquent et représentatif du marché de la région lausannoise ont été analysés. Finalement, les données obtenues ont été traitées et interprétées à l'aide de méthodes chimiométriques. Les analyses effectuées ont permis de montrer que la méthodologie mise en place, aussi bien pour la composante MS que pour l'IRMS, permet de différencier des échantillons d'essence non altérée provenant de différentes stations-service. Il a également pu être démontré qu'à chaque nouveau remplissage des cuves d'une station-service, la composition de l'essence distribuée par cette station est quasi unique. La GC-MS permet une meilleure différenciation d'échantillons prélevés dans différentes stations, alors que la GC-IRMS est plus performante lorsqu'il s'agit de comparer des échantillons collectés après chacun des remplissages d'une cuve. Ainsi, ces résultats indiquent que les deux composantes de la méthode peuvent être complémentaires pour l'analyse d'échantillons d'essence non altérée. Les résultats obtenus ont également permis de montrer que l'évaporation des échantillons d'essence ne compromet pas la possibilité de grouper des échantillons de même source par GC-MS. Il est toutefois nécessaire d'effectuer une sélection des variables afin d'éliminer celles qui sont influencées par le phénomène d'évaporation. Par contre, les analyses effectuées ont montré que l'évaporation des échantillons d'essence a une forte influence sur la composition isotopique des échantillons. Cette influence est telle qu'il n'est pas possible, même en effectuant une sélection des variables, de grouper correctement des échantillons évaporés par GC-IRMS. Par conséquent, seule la composante MS de la méthodologie mise en place permet d'inférer la source d'échantillons d'essence évaporée. _________________________________________________________________________________________________ When gasoline is used to start and / or propagate an arson, source inference of gasoline can allow to establish a link between the fire and a potential source. This source inference is an interesting alternative to provide evidence in this type of events where physical evidence left by the author are rare. The main purpose of this research was to develop a GC-IRMS method for the analysis of gasoline samples, a non-routine method and little investigated in forensic science, and to evaluate its potential to infer the source of gasoline traces compared to the GC-MS performances. An instrument allowing to analyze simultaneously samples by MS and IRMS was used in this research. An analytical method was developed, optimized and validated for this instrument. Thereafter, gasoline samples from a large sampling and representative of the Lausanne area market were analyzed. Finally, the obtained data were processed and interpreted using chemometric methods. The analyses have shown that the methodology, both for MS and for IRMS, allow to differentiate unweathered gasoline samples from different service stations. It has also been demonstrated that each new filling of the tanks of a station generates an almost unique composition of gasoline. GC-MS achieves a better differentiation of samples coming from different stations, while GC-IRMS is more efficient to distinguish samples collected after each filling of a tank. Thus, these results indicate that the two components of the method can be complementary to the analysis of unweathered gasoline samples. The results have also shown that the evaporation of gasoline samples does not compromise the possibility to group samples coming from the same source by GC-MS. It is however necessary to make a selection of variables in order to eliminate those which are influenced by the evaporation. On the other hand, the carried out analyses have shown that the evaporation of gasoline samples has such a strong influence on the isotopic composition of the samples that it is not possible, even by performing a selection of variables, to properly group evaporated samples by GC-IRMS. Therefore, only the MS allows to infer the source of evaporated gasoline samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

L’immunité adaptive et la discrimination entre le soi et le non-soi chez les vertébrés à mâchoire reposent sur la présentation de peptides par les récepteurs d’histocompatibilité majeur de classe I. Les peptides antigéniques, présentés par les molécules du complexe d’histocompatibilité (CMH), sont scrutés par les lymphocytes T CD8 pour une réponse immunitaire appropriée. Le répertoire des peptides du CMH de classe I, aussi appelé immunopeptidome, est généré par la dégradation protéosomale des protéines endogènes, et a un rôle essentiel dans la régulation de l’immunité cellulaire. La composition de l’immunopeptidome dépend du type de cellule et peut présenter des caractéristiques liées à des maladies comme le cancer. Les peptides antigéniques peuvent être utilisés à des fins immunothérapeutiques notamment dans le traitement voire la prévention de certains cancers. La spectrométrie de masse est un outil de choix pour l’identification, le séquençage et la caractérisation de ces peptides. Cependant, la composition en acides aminés, la faible abondance et la diversité de ces peptides compliquent leur détection et leur séquençage. Nous avons développé un programme appelé StatPeaks qui permet de calculer un certains nombres de statistiques relatives à la fragmentation des peptides. À l’aide de ce programme, nous montrons sans équivoque que les peptides du CMH classe I, en mode de fragmentation par dissociation induite par collision (CID), fragmentent très différemment des peptides trypsiques communément utilisés en protéomique. Néanmoins, la fragmentation par décomposition induite par collision à plus haute énergie (HCD) proposée par le spectromètre LTQ-Orbitrap Velos améliore la fragmentation et fournit une haute résolution qui permet d’obtenir une meilleure confiance dans l’identification des peptides du CMH de classe I. Cet avantage permet d’effectuer le séquençage de novo pour identifier les variants polymorphes qui ne sont normalement pas identifiés par les recherches utilisant des bases de données. La comparaison des programmes de séquençage Lutefisk, pepNovo, pNovo, Vonode et Peaks met en évidence que le dernier permet d’identifier un plus grand nombre de peptides du CMH de classe I. Ce programme est intégré dans une chaîne de traitement de recherche d’antigènes mineurs d’histocompatibilité. Enfin, une base de données contenant les informations spectrales de plusieurs centaines de peptides du CMH de classe I accessible par Internet a été développée.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal