170 resultados para Malvern


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unfavorable immediate or delayed results after transcatheter aortic valve implantation (TAVI) may be a consequence of bioprosthesis malfunctioning, malpositioning, embolization, or degeneration. Deployment of a second valve within the first one implanted (TAVI-in-TAV) may be a potentially helpful therapeutic strategy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the clinical outcome of a 46-year-old man referred for percutaneous closure of an atrial septal defect under transthoracic echocardiographic and fluoroscopic guidance, whose upper left pulmonary vein was erroneously obliterated using an Amplatzer atrial septal defect occluder. Various medical conditions have been associated with pulmonary vein stenosis including dyspnea on exertion or at rest, cough, and hemoptysis. However, there were no short- or long-term symptoms in this patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Drug-coated balloons (DCB) are being increasingly used in interventional cardiology and are established for the treatment of in-stent restenosis (ISR). It is unclear how effective they are in patients with de novo lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To demonstrate the safety and feasibility of a new concept for CTO recanalization using a controlled antegrade and retrograde subintimal tracking technique (CART technique). BACKGROUND: A successful percutaneous recanalization of chronic coronary occlusions results in improved survival, as well as enhanced left ventricular function, reduction in angina, and improved exercise tolerance. However, successful recanalization of CTOs is still not optimal, and needs further improvements. METHODS: Ten patients with a CTO underwent the CART procedure. This technique combines the simultaneous use of the antegrade and retrograde approaches. A subintimal dissection is created antegradely and retrogradely, which allows the operator to limit the extension of the subintimal dissection in the CTO portion. A retrograde approach means that the occlusion site is approached in a retrograde fashion through the best collateral channel from any other patent coronary artery. RESULTS: The occlusion site was located in the RCA in 9 patients, and in the LAD in 1 patient. CTO duration varied from 7 to 84 months. Vessel recanalization was achieved in all patients. In all cases, the subintimal dissection was limited to the CTO region. No complications occurred in the collateral channel used for the retrograde approach. There were no in-hospital major adverse cardiac events. CONCLUSIONS: The CART technique is feasible, safe, and has a high success rate.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary aneurysm formation after drug-eluting stent (DES) implantation is a rare complication with late stent thrombosis as a potentially fatal sequela. One possible mechanism involved in aneurysm formation is thought to be late-acquired stent malapposition due to a local inflammatory response to the polymer and/or the drug. Coronary aneurysm formation has been documented with sirolimus- and paclitaxel-eluting stents. We report a case of coronary aneurysm formation in a patient with an everolimus-eluting stent (EES; Xience(R) Abbott Vascular, Redwood City, California) relatively early (3 months) after stent implantation. This case illustrates that even with second-generation DES like the EES, which is thought to be highly biocompatible, there can be adverse reactions to the polymer and/or to the drug.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Vascular healing of intracoronary stents has been shown to be delayed in drug-eluting stents (DES) due to the cytotoxic compounds on the stent surface that prevent stent ingrowth and endothelialization. The lack of endothelialization explains the occurrence of late and very late stent thrombosis in DES. MATERIALS AND METHODS: In 11 house swines (body weight 38-45 kg), 3 stents were implanted randomly into the 3 large epicardial coronary arteries, namely a bare-metal stent (BMS), a sirolimus-eluting stent with slow-release (SES) and a SES with extended-release (SESXR). Stent length was 18 mm, and stent diameter 3 mm. All stents were of identical design. Animals were followed for 3 (n = 3), 7 (n = 4) and 14 (n = 4) days, respectively. One animal died before implantation due to hyperthermia. On the day of explantation, the animals were euthanized and endothelialization was tested by scanning electron microscopy after drying and sputtering the samples. Endothelial coverage was determined semiquantitatively by 2 observers. RESULTS: Endothelialization was more rapid with BMS and SESXR than SES at 3 and 14 days. At 7 days there were no significant differences between the 2 SES. CONCLUSIONS: Endothelialization of intracoronary stents is faster with BMS and SESXR at 3 days than with SES. These differences persist at 14 days, suggesting delayed vascular healing with the slow-release SES.