991 resultados para MECHANICAL FLOCCULATION UNIT
Resumo:
Introduction: Patients undergoing mechanical ventilation (MV) are frequently administered prolonged and/or high doses of opioids which when removed can cause a withdrawal syndrome and difficulty in weaning from MV. We tested the hypothesis that the introduction of enteral methadone during weaning from sedation and analgesia in critically ill adult patients on MV would decrease the weaning time from MV. Methods: A double-blind randomized controlled trial was conducted in the adult intensive care units (ICUs) of four general hospitals in Brazil. The 75 patients, who met the criteria for weaning from MV and had been using fentanyl for more than five consecutive days, were randomized to the methadone (MG) or control group (CG). Within the first 24 hours after study enrollment, both groups received 80% of the original dose of fentanyl, the MG received enteral methadone and the CG received an enteral placebo. After the first 24 hours, the MG received an intravenous (IV) saline solution (placebo), while the CG received IV fentanyl. For both groups, the IV solution was reduced by 20% every 24 hours. The groups were compared by evaluating the MV weaning time and the duration of MV, as well as the ICU stay and the hospital stay. Results: Of the 75 patients randomized, seven were excluded and 68 were analyzed: 37 from the MG and 31 from the CG. There was a higher probability of early extubation in the MG, but the difference was not significant (hazard ratio: 1.52 (95% confidence interval (CI) 0.87 to 2.64; P = 0.11). The probability of successful weaning by the fifth day was significantly higher in the MG (hazard ratio: 2.64 (95% CI: 1.22 to 5.69; P < 0.02). Among the 54 patients who were successfully weaned (29 from the MG and 25 from the CG), the MV weaning time was significantly lower in the MG (hazard ratio: 2.06; 95% CI 1.17 to 3.63; P < 0.004). Conclusions: The introduction of enteral methadone during weaning from sedation and analgesia in mechanically ventilated patients resulted in a decrease in the weaning time from MV.
Resumo:
The aim of this paper is to study the feasibility of using cellulose fibers obtained from an agricultural waste, hemp core (Cannabis Sativa L), through different new environmental friendly cooking processes for fiber-cement production. The physical and mechanical properties of the fiber reinforced concrete, which depend on the nature and morphology of the fibers, matrix properties and the interactions between them, must be kept between the limits required for its application. Therefore, the morphology of the fibers and how its use affects the flocculation, retention and drainage processes in the fiber-cement manufacture, and the mechanical and physical properties of the fiber-cement product have been studied. The use of pulp obtained by means of the hemp core cooking in ethanolamine at 60% concentration at 180 degrees C during 90 min resulted in the highest solids retention and the best mechanical properties among the studied hemp core pulps. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)
Resumo:
The aim of Tissue Engineering is to develop biological substitutes that will restore lost morphological and functional features of diseased or damaged portions of organs. Recently computer-aided technology has received considerable attention in the area of tissue engineering and the advance of additive manufacture (AM) techniques has significantly improved control over the pore network architecture of tissue engineering scaffolds. To regenerate tissues more efficiently, an ideal scaffold should have appropriate porosity and pore structure. More sophisticated porous configurations with higher architectures of the pore network and scaffolding structures that mimic the intricate architecture and complexity of native organs and tissues are then required. This study adopts a macro-structural shape design approach to the production of open porous materials (Titanium foams), which utilizes spatial periodicity as a simple way to generate the models. From among various pore architectures which have been studied, this work simulated pore structure by triply-periodic minimal surfaces (TPMS) for the construction of tissue engineering scaffolds. TPMS are shown to be a versatile source of biomorphic scaffold design. A set of tissue scaffolds using the TPMS-based unit cell libraries was designed. TPMS-based Titanium foams were meant to be printed three dimensional with the relative predicted geometry, microstructure and consequently mechanical properties. Trough a finite element analysis (FEA) the mechanical properties of the designed scaffolds were determined in compression and analyzed in terms of their porosity and assemblies of unit cells. The purpose of this work was to investigate the mechanical performance of TPMS models trying to understand the best compromise between mechanical and geometrical requirements of the scaffolds. The intention was to predict the structural modulus in open porous materials via structural design of interconnected three-dimensional lattices, hence optimising geometrical properties. With the aid of FEA results, it is expected that the effective mechanical properties for the TPMS-based scaffold units can be used to design optimized scaffolds for tissue engineering applications. Regardless of the influence of fabrication method, it is desirable to calculate scaffold properties so that the effect of these properties on tissue regeneration may be better understood.
Resumo:
Rotator cuff lesions are common and the incidence increases with age. After tendon rupture of the rotator cuff, the muscle-tendon unit retracts, which is accompanied by muscle fatty infiltration, atrophy, and interstitial fibrosis of the musculature, thus, fundamentally changing the muscle architecture. These changes are important prognostic factors for the operative rotator cuff reconstruction outcome. Selection of the correct time point for reconstruction as well as the optimal mechanical fixation technique are decisive for successful attachment at the tendon-to-bone insertion site. Thus, knowledge of the pathophysiological processes plays an important role. The goal of this article is to establish a relationship between currently existing evidence with respect to the preoperatively existing changes of the muscle-tendon unit and the choice of the time for the operation and the operative technique.
Resumo:
Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.
Resumo:
PURPOSE: We studied the effects of reorganization and changes in the care process, including use of protocols for sedation and weaning from mechanical ventilation, on the use of sedative and analgesic drugs and on length of respiratory support and stay in the intensive care unit (ICU). MATERIALS AND METHODS: Three cohorts of 100 mechanically ventilated ICU patients, admitted in 1999 (baseline), 2000 (implementation I, after a change in ICU organization and in diagnostic and therapeutic approaches), and 2001 (implementation II, after introduction of protocols for weaning from mechanical ventilation and sedation), were studied retrospectively. RESULTS: Simplified Acute Physiology Score II (SAPS II), diagnostic groups, and number of organ failures were similar in all groups. Data are reported as median (interquartile range).Time on mechanical ventilation decreased from 18 (7-41) (baseline) to 12 (7-27) hours (implementation II) (P = .046), an effect which was entirely attributable to noninvasive ventilation, and length of ICU stay decreased in survivors from 37 (21-71) to 25 (19-63) hours (P = .049). The amount of morphine (P = .001) and midazolam (P = .050) decreased, whereas the amount of propofol (P = .052) and fentanyl increased (P = .001). Total Therapeutic Intervention Scoring System-28 (TISS-28) per patient decreased from 137 (99-272) to 113 (87-256) points (P = .009). Intensive care unit mortality was 19% (baseline), 8% (implementation I), and 7% (implementation II) (P = .020). CONCLUSIONS: Changes in organizational and care processes were associated with an altered pattern of sedative and analgesic drug prescription, a decrease in length of (noninvasive) respiratory support and length of stay in survivors, and decreases in resource use as measured by TISS-28 and mortality.
Resumo:
PURPOSE: To compare dexmedetomidine (DEX) with standard care (SC, either propofol or midazolam) for long-term sedation in terms of maintaining target sedation and length of intensive care unit (ICU) stay. METHODS: A pilot, phase III, double-blind multicenter study in randomized medical and surgical patients (n = 85) within the first 72 h of ICU stay with an expected ICU stay of >or=48 h and sedation need for >or=24 h after randomization. Patients were assigned to either DEX (
Resumo:
BACKGROUND: Sedation protocols, including the use of sedation scales and regular sedation stops, help to reduce the length of mechanical ventilation and intensive care unit stay. Because clinical assessment of depth of sedation is labor-intensive, performed only intermittently, and interferes with sedation and sleep, processed electrophysiological signals from the brain have gained interest as surrogates. We hypothesized that auditory event-related potentials (ERPs), Bispectral Index (BIS), and Entropy can discriminate among clinically relevant sedation levels. METHODS: We studied 10 patients after elective thoracic or abdominal surgery with general anesthesia. Electroencephalogram, BIS, state entropy (SE), response entropy (RE), and ERPs were recorded immediately after surgery in the intensive care unit at Richmond Agitation-Sedation Scale (RASS) scores of -5 (very deep sedation), -4 (deep sedation), -3 to -1 (moderate sedation), and 0 (awake) during decreasing target-controlled sedation with propofol and remifentanil. Reference measurements for baseline levels were performed before or several days after the operation. RESULTS: At baseline, RASS -5, RASS -4, RASS -3 to -1, and RASS 0, BIS was 94 [4] (median, IQR), 47 [15], 68 [9], 75 [10], and 88 [6]; SE was 87 [3], 46 [10], 60 [22], 74 [21], and 87 [5]; and RE was 97 [4], 48 [9], 71 [25], 81 [18], and 96 [3], respectively (all P < 0.05, Friedman Test). Both BIS and Entropy had high variabilities. When ERP N100 amplitudes were considered alone, ERPs did not differ significantly among sedation levels. Nevertheless, discriminant ERP analysis including two parameters of principal component analysis revealed a prediction probability PK value of 0.89 for differentiating deep sedation, moderate sedation, and awake state. The corresponding PK for RE, SE, and BIS was 0.88, 0.89, and 0.85, respectively. CONCLUSIONS: Neither ERPs nor BIS or Entropy can replace clinical sedation assessment with standard scoring systems. Discrimination among very deep, deep to moderate, and no sedation after general anesthesia can be provided by ERPs and processed electroencephalograms, with similar P(K)s. The high inter- and intraindividual variability of Entropy and BIS precludes defining a target range of values to predict the sedation level in critically ill patients using these parameters. The variability of ERPs is unknown.
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.
Resumo:
Risk factors for Multi-Drug Resistant Acinetobacter (MDRA) acquisition were studied in patients in a burn intensive care unit (ICU) where there was an outbreak of MDRA. Forty cases were matched with eighty controls based on length of stay in the Burn ICU and statistical analysis was performed on data for several different variables. Matched analysis showed that mechanical ventilation, transport ventilation, number of intubations, number of bronchoscopy procedures, total body surface area burn, and prior Methicillin Resistant Staphylococcus aureus colonization were all significant risk factors for MDRA acquisition. ^ MDRA remains a significant threat to the burn population. Treatment for burn patients with MDRA is challenging as resistance to antibiotics continues to increase. This study underlined the need to closely monitor the most critically ill ventilated patients during an outbreak of MDRA as they are the most at risk for MDRA acquisition.^
Resumo:
Muscular weakness and muscle wasting may often be observed in critically ill patients on intensive care units (ICUs) and may present as failure to wean from mechanical ventilation. Importantly, mounting data demonstrate that mechanical ventilation itself may induce progressive dysfunction of the main respiratory muscle, i.e. the diaphragm. The respective condition was termed 'ventilator-induced diaphragmatic dysfunction' (VIDD) and should be distinguished from peripheral muscular weakness as observed in 'ICU-acquired weakness (ICU-AW)'. Interestingly, VIDD and ICU-AW may often be observed in critically ill patients with, e.g. severe sepsis or septic shock, and recent data demonstrate that the pathophysiology of these conditions may overlap. VIDD may mainly be characterized on a histopathological level as disuse muscular atrophy, and data demonstrate increased proteolysis and decreased protein synthesis as important underlying pathomechanisms. However, atrophy alone does not explain the observed loss of muscular force. When, e.g. isolated muscle strips are examined and force is normalized for cross-sectional fibre area, the loss is disproportionally larger than would be expected by atrophy alone. Nevertheless, although the exact molecular pathways for the induction of proteolytic systems remain incompletely understood, data now suggest that VIDD may also be triggered by mechanisms including decreased diaphragmatic blood flow or increased oxidative stress. Here we provide a concise review on the available literature on respiratory muscle weakness and VIDD in the critically ill. Potential underlying pathomechanisms will be discussed before the background of current diagnostic options. Furthermore, we will elucidate and speculate on potential novel future therapeutic avenues.
Resumo:
Press release attached to verso includes: This picture ran three times. In the issue of May 2,1943, in the general supplement of Nov. 2, 1943, and on Jan. 16, 1944. May 2nd: A demonstration in the mechanical engineering laboratory is being given to these members of the engineering unit of the Army Specialized Training at the University.
Resumo:
The aim of this paper is to investigate the effect of shear history on activated sludge flocculation dynamics and to model the observed relationships using population balances. Activated sludge flocs are exposed to dramatic changes in the shear rate within the treatment process, as they pass through localised high and low mixing intensities within the aeration basin and are cycled through the different unit operations of the treatment process. We will show that shear history is a key factor in determining floc size, and that the floc size varies irreversibly with changes in shear rate. A population balance model of the flocculation process is also introduced and evaluated.