913 resultados para ME and EP method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new mild method has been devised for generating o-(naphtho)quinone methides via fluoride-induced desilylation of silyl derivatives of o-hydroxybenzyl(or 1-naphthylmethyl) nitrate. The reactive o-(naphtho)quinone methide intermediates were trapped by C, O, N and S nucleophiles and underwent “inverse electron-demand” hetero Diels- Alder reaction with dienophiles to give stable adducts. The method has useful potential application in natural product synthesis and drug research

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a reinterpretation of James Harrington's writings. It takes issue with J. G. A. Pocock's reading, which treats him as importing into England a Machiavellian ‘language of political thought’. This reading is the basis of Pocock's stress on the republicanism of eighteenth-century opposition values. Harrington's writings were in fact a most implausible channel for such ideas. His outlook owed much to Stoicism. Unlike the Florentine, he admired the contemplative life; was sympathetic to commerce; and was relaxed about the threat of ‘corruption’ (a concept that he did not understand). These views can be associated with his apparent aims: the preservation of a national church with a salaried but politically impotent clergy; and the restoration of the royalist gentry to a leading role in English politics. Pocock's hypothesis is shown to be conditioned by his method; its weaknesses reflect some difficulties inherent in the notion of ‘languages of thought’.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, fast, accurate, and sensitive spectrophotometric method was developed to determine zinc(II). This method is based on the reaction of Zn(II) with di-2-pyridyl ketone benzoylhydrazone (DPKBH), at pH=5.5 and 50% (v/v) ethanol. Beers law was obeyed in the range 0.020-1.82 mu g mL(-1) with a molar apsorptivity of 3.64 x 10(4) L mol(-1) cm(-1), and a detection limit (3) of 2.29 mu g L-1. The action of some interfering ions was verified and the developed method applied to pharmaceutical and biological samples. The results were then compared with those obtained by using a flame atomic absorption technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When an accurate hydraulic network model is available, direct modeling techniques are very straightforward and reliable for on-line leakage detection and localization applied to large class of water distribution networks. In general, this type of techniques based on analytical models can be seen as an application of the well-known fault detection and isolation theory for complex industrial systems. Nonetheless, the assumption of single leak scenarios is usually made considering a certain leak size pattern which may not hold in real applications. Upgrading a leak detection and localization method based on a direct modeling approach to handle multiple-leak scenarios can be, on one hand, quite straightforward but, on the other hand, highly computational demanding for large class of water distribution networks given the huge number of potential water loss hotspots. This paper presents a leakage detection and localization method suitable for multiple-leak scenarios and large class of water distribution networks. This method can be seen as an upgrade of the above mentioned method based on a direct modeling approach in which a global search method based on genetic algorithms has been integrated in order to estimate those network water loss hotspots and the size of the leaks. This is an inverse / direct modeling method which tries to take benefit from both approaches: on one hand, the exploration capability of genetic algorithms to estimate network water loss hotspots and the size of the leaks and on the other hand, the straightforwardness and reliability offered by the availability of an accurate hydraulic model to assess those close network areas around the estimated hotspots. The application of the resulting method in a DMA of the Barcelona water distribution network is provided and discussed. The obtained results show that leakage detection and localization under multiple-leak scenarios may be performed efficiently following an easy procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho apresentado no Congresso Nacional de Matemática Aplicada à Indústria, 18 a 21 de novembro de 2014, Caldas Novas - Goiás

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study compared three methods of Streptococcus mutans and Lactobacillus spp. detection in the oral cavity: saliva swab (SS)-sample of stimulated saliva collected with swab; whole saliva (WS)-sample of 2 ml of stimulated saliva; and the dental plaque method (DP)-plaque sample of all dental surfaces.Methods: Thirty children were included in this study. In the first 15 children, the SS and WS methods were carried out before the dental plaque collection, and in the following 15, the sequence was inverted to evaluate possible interference of the methods sequence. The samples were diluted and inoculated in SB20 and Rogosa agar, respectively for S. mutans and Lactobacillus spp., at 37 degrees C for 48 h.Results: the results (cfu/mL) of S. mutans were analysed by the statistical Friedman's test. The levels of Lactobacillus spp. were analysed by descriptive statistics due to the high proportion of zero counts in the culture. In the first sequence of methods, the number of S. mutans counted for the SS method was inferior to DP and WS (P < 0.05), and the results for the WS and DP methods were similar. The detection of Lactobacillus spp. was observed just by the WS (100 %) and SS (14.3 %) methods. However, in the second experimental set the number of S. mutans detected by the DP method was similar to those of the SS and WS, however, the WS method showed higher values than SS (P < 0.05). A greater number of Lactobacillus spp. was detected by the WS method (100 %), followed by SS (55.5 %) and DP (33.3 %).Conclusions: the dental plaque collection and the sample of stimulated whole saliva presented similar results in the S. mutans count. The most suitable method to detect the Lactobacillus spp. level in the oral cavity is the stimulated whole saliva method. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of application methods and dentin hydration on the bond strength of three self-etching adhesives (SEA) were evaluated; 195 extracted bovine incisors were used. The buccal surface was ground in order to expose the dentin, which remained 2-mm minimum thickness, measured by a thickness meter through an opening on the lingual surface. Adper Single Bond 2 (TM) was used for the control group. The SEA were applied following two modes of application: passive or active and two hydration states of the dentin surface-dry and wet. After light-curing, composite buildups were made using Grandio (TM) composite. The specimens were sectioned and tested with a microtensile bond strength test. The application method and the hydration state resulted in statistical differences (p = 0.000) making the values of active application for mu TBS to dentin higher than passive application. The wet surfaces showed higher mu TBS to dentin ratios than dry surfaces. There were no statistical differences in mu TBS among the SEA tested but there were differences regarding to control group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of surface hydration state and application method on the microtensile bond strength of one-step self-etching adhesives systems to cut enamel.Materials and Methods: One hundred ninety-five bovine teeth were used. The enamel on the buccal side was flattened with 600-grit SiC paper. For the control group, 15 teeth received Adper Single Bond 2, applied according to manufacturer's recommendations. The other specimens were divided into three groups according to the adhesive system used: Futura Bond M (FM; Voco), Clearfil S-3 Bond (CS; Kuraray), and Optibond All in One (OA; Kerr). For each group, two hydration states were tested: D: blown dry with air; W: the excess of water was removed with absorbent paper. Two application methods were tested: P (passive): the adhesive was simply left on the surface; A (active): the adhesive was rubbed with an applicator point. A coat of Grandio composite resin (Voco) was applied on the surface. The teeth were sectioned to obtain enamel-resin sticks (1 x 1 mm), which underwent microtensile bond testing. The data in MPa were submitted to a three-way ANOVA and Tukey's test (alpha = 5%).Results: The ANOVA showed significant differences for application method and the type of adhesive, but not for hydration state. For the application method, the results of Tukey's test were: P: 31.46 (+/-7.09)a; A: 34.04 (+/-7.19)b. For the type of adhesive, the results were: OA: 31.29 (+/-7.05)a; CS: 32.28 (+/-7.14)a; FM: 34.68 (+/-7.17)b; different lower-case letters indicate statistically significant differences.Conclusion: Active application improved the bond strength to cut enamel. The adhesive Futurabond M showed the highest bond strength to cut enamel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Calcium plays a fundamental role in cell division and growth, and is an important constituent of the cell wall. An increase in Ca concentration in the tegument of peanut (Arachis hypogea L.) seeds in response to lime application can affect its structure. The tegument structure can also be affected by the drying method of the seeds. The effects of lime application and drying methods as affecting the peanut seed tegument structure were studied in seeds from a field experiment conducted in Sao Manuel, São Paulo, Brazil. Peanut (cv. Botutatu, Valencia Type) was grown in presence or absence of 2.1 Mg ha(-1) of lime and dried in an oven, in shade and in the field. The tegument anatomical features were described and its structure was analysed. Pectic substances, lipidic reserves and starch accumulation were studied. The peanut tegument exhibited well differentiated exotesta, mesotesta and endotesta rich in pectates and covered by a cuticle. Tannin was not observed but there was lipid accumulation in mature teguments. Lignin was observed in the vascular bundles. Lime increased the tegument thickness and decreased the central cavity mainly in the exotesta cells when the period of seed drying was shortened. The effect of drying method upon the tegument was more noticeable in seeds grown without lime. It can be inferred that liming increased the resistance of the tegument.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high-performance liquid chromatography (HPLC) method for the determination of acetaldehyde in fuel ethanol was developed. Acetaldehyde was derivatized with 0.900 mL 2,4-dinitrophenylhydrazine (DNPHi) reagent and 50 mu L phosphoric acid 1 mol L-1 at a controlled room temperature of 15 degrees C for 20 min. The separation of acetaldehyde- DNPH (ADNPH) was carried out on a Shimadzu Shim-pack C-18 column, using methanol/LiCl(aq) 1.0 mM (80/20, v/v) as a mobile phase under isocratic elution and UV-Vis detection at 365 nm. The standard curve of ADNPH was linear in the range 3-300 amg L-1 per injection (20 mu L) and the limit of detection (LOD) for acetaldehyde was 2.03 mu g L-1, with a correlation coefficient greater than 0.999 and a precision (relative standard deviation, RSD) of 5.6% (n=5). Recovery studies were performed by fortifying fuel samples with acetaldehyde at various concentrations and the results were in the range 98.7-102%, with a coefficient of variation (CV) from 0.2% to 7.2%. Several fuel samples collected from various gas stations were analyzed and the method was successfully applied to the analysis of acetaldehyde in fuel ethanol samples.