1000 resultados para MAGNETOMECHANICAL SENSORS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design and development of a Fiber Bragg Grating (FBG) sensor system for monitoring tsunami waves generated in the deep ocean. An experimental setup was designed and fabricated to simulate the generation and propagation of a tsunami wave. The characteristics and efficiency of the developed FBG sensor was evaluated with a standard commercial Digiquartz sensor. For real time monitoring of tsunami waves, FBG sensors bonded to a cantilever is used and the wavelength shifts (Delta lambda(B)) in the reflected spectra resulting from the strain/pressure imparted on the FBGs have been recorded using a high-speed Micron Optics FBG interrogation system. The parameters sensed are the signal burst during tsunami generation and pressure variations at different places as the tsunami wave propagates away from the source of generation. The results obtained were compared with the standard commercial sensor used in tsunami detection. The observations suggest that the FBG sensor was highly sensitive and free from many of the constraints associated with the commercial tsunameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared Earth sensors are used in spacecraft for attitude sensing. Their accuracy is limited by systematic and random errors. Dominant sources of systematic errors are analyzed for a typical scanning infrared Earth sensor used in a remote-sensing satellite in a 900-km sun-synchronous orbit. The errors considered arise from 1) seasonable variation of infrared radiation, 2) oblate shape of the Earth, 3) ambient temperature of sensors, 4) changes in spin/scan period, and 5) misalignment of the axis of the sensors. Simple relations are derived using least-squares curve fitting for onboard correction of these errors. With these, it is possible to improve the accuracy of attitude determination by eight fold and achieve performance comparable to ground-based post-facto attitude computation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The criterion for the design of a temperature-compensated reference electrode for non-isothermal galvanic sensors is deduced from the basic flux equations of irreversible thermodynamics. It is shown that when the Seebeck coefficient of the non-isothermal cell using a solid oxygen ion-conducting electrolyte under pure oxygen is equal to the relative partial molar entropy of oxygen in the reference electrode divided by 4F, then the EMF of the non-isothermal cell is the same as that of an isothermal cell with the same electrodes operating at the higher temperature. By measuring the temperature of the melt alone and the EMF of the non-isothermal galvanic sensor, one can derive the chemical potential or the concentration of oxygen in a corrosive medium. The theory is experimentally checked using sensors for oxygen in liquid copper constructed with various metal+oxide electrodes and fully stabilised (CaO)ZrO2 as the electrolyte. To satisfy the exact condition for temperature compensation it is often necessary to have the metal or oxide as a solid solution in the reference electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Room-temperature sensing characteristics for H-2, ethanol, NH3, H2S and water have been investigated with thick-film sensors based on GaN nanoparticles, prepared by a simple chemical route. In general, GaN nanoparticles exhibit satisfactory sensor properties for these gases and vapors even at room temperature. The sensitivity for ethanol is found to be highest, the sensitivity and recovery times being smallest. Gas sensor properties of GaN seem to be related to intrinsic defects, which act as sorption sites for the gas molecules. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

V2O5 supported on ZrO2 is found to be an excellent sensor for n-propane-butane mixtures at 625 K; in-situ X-ray diffraction studies show that V2O5 is reduced to VO2 with a metastable monoclinic structure on contact with the hydrocarbons and is oxidised back to the parent oxide on exposure to air.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic principles of operation of gas sensors based on solid-state galvanic cells are described. The polarisation of the electrodes can be minimised by the use of point electrodes made of the solid electrolyte, the use of a reference system with chemical potential close to that of the sample system and the use of graded condensed phase reference electrodes. Factors affecting the speed of response of galvanic sensors in equilibrium and non-equilibrium gas mixtures are considered with reference to products of combustion of fossil fuels. An expression for the emf of non-isothermal galvanic sensors and the criterion for the design of temperature compensated reference electrodes for non-isothermal galvanic sensors are briefly outlined. Non-isothermal sensors are useful for the continuous monitoring of concentrations or chemical potentials in reactive systems at high temperatures. Sensors for oxygen, carbon, and alloying elements (Zn and Si) in liquid metals and alloys are discussed. The use of auxiliary electrodes permits the detection of chemical species in the gas phase which are not mobile in the solid electrolyte. Finally, the cause of common errors in galvanic measurements, and tests for correct functioning of galvanic sensors are given. 60 ref.--AA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber bragg grating (FBG) sensors have been widely used for number of sensing applications like temperature, pressure, acousto-ultrasonic, static and dynamic strain, refractive index change measurements and so on. Present work demonstrates the use of FBG sensors in in-situ measurement of vacuum process with simultaneous leak detection capability. Experiments were conducted in a bell jar vacuum chamber facilitated with conventional Pirani gauge for vacuum measurement. Three different experiments have been conducted to validate the performance of FBG sensor in monitoring vacuum creating process and air bleeding. The preliminary results of FBG sensors in vacuum monitoring have been compared with that of commercial Pirani gauge sensor. This novel technique offers a simple alternative to conventional method for real time monitoring of evacuation process. Proposed FBG based vacuum sensor has potential applications in vacuum systems involving hazardous environment such as chemical and gas plants, automobile industries, aeronautical establishments and leak monitoring in process industries, where the electrical or MEMS based sensors are prone to explosion and corrosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper considers the problem of power management and throughput maximization for energy neutral operation when using Energy Harvesting Sensors (EHS) to send data over wireless links. It is assumed that the EHS are designed to transmit data at a constant rate (using a fixed modulation and coding scheme) but are power-controlled. A framework under which the system designer can optimize the performance of EHS when the channel is Rayleigh fading is developed. For example, the highest average data rate that can be supported over a Rayleigh fading channel given the energy harvesting capability, the battery power storage efficiency and the maximum allowed transmit energy per slot is derived. Furthermore, the optimum transmission scheme that guarantees a particular data throughput is derived. The usefulness of the framework developed is illustrated through simulation results for specific examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polypyrrole exhibits reversible changes in their direct current resistance on exposure to organic volatiles. However, one needs to employ an array of such sensors to discriminate organic volatiles present in a mixture. Hence, polypyrrole based gas sensor is designed for the detection and discrimination of different organic volatiles. Multi frequency impedance measurement technique is used to detect the organic vapors, such as acetone, ethanol and Isopropyl alcohol, in the gas phase, over a frequency range 10 Hz to 2 MHz. The sensor response is monitored by measuring the changes in its capacitance, resistance and the dissipation factor upon exposure to organic volatiles. It is observed that the capacitive property of the sensor is more sensitive to these volatiles than its resistive property. Each volatile responds to the sensor in terms of dissipation factor at specific frequency and found that the peak magnitude has a linear relationship with their concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Donor-doped n-BaTiO3 polycrystalline ceramics show a strong negative temperature coefficient of resistivity below the orthorhombic-rhombohedral phase transition point, from 10(2-3) Omega cm af 190 K to 10(10-13) Omega cm at less than or similar to 50 K, with thermal coefficient of resistance alpha = 20-23% K-1. Stable thermal sensors for low-temperature applications are realized therefrom. The negative temperature coefficient of resistivity region can be modified by substituting isovalent ions in the lattice. Highly nonlinear current-voltage (I-V) curves are observed at low temperatures, with a voltage maximum followed by the negative differential resistance. The I-V curves are sensitive to dissipation so that cryogenic sensors can be fabricated for liquid level control, flow rate monitoring, radiation detection or in-rush voltage limitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The humidity, heat flux and mass flow sensing capability of n-BaTiO3 and its solid solutions were evaluated based on their dissipation characteristics. The cubic/tetragonal phase content of the ceramics seem to play an important role in their sensitivity towards the measurand. The humidity-sensitive characteristics of these perovskites were studied with respect to different moisture sensitive coating materials. The sensor was also used to determine the heat of hydration during the curing process of cements and the mass flow rate of the gases. For all these applications, suitable operating points have been fixed from the highly non-linear I-V characteristics with the retention of good stability and high sensitivity. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, power management algorithms for energy harvesting sensors (EHS) that operate purely based on energy harvested from the environment are proposed. To maintain energy neutrality, EHS nodes schedule their utilization of the harvested power so as to save/draw energy into/from an inefficient battery during peak/low energy harvesting periods, respectively. Under this constraint, one of the key system design goals is to transmit as much data as possible given the energy harvesting profile. For implementational simplicity, it is assumed that the EHS transmits at a constant data rate with power control, when the channel is sufficiently good. By converting the data rate maximization problem into a convex optimization problem, the optimal load scheduling (power management) algorithm that maximizes the average data rate subject to energy neutrality is derived. Also, the energy storage requirements on the battery for implementing the proposed algorithm are calculated. Further, robust schemes that account for the insufficiency of battery storage capacity, or errors in the prediction of the harvested power are proposed. The superior performance of the proposed algorithms over conventional scheduling schemes are demonstrated through computations using numerical data from solar energy harvesting databases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wireless Energy Harvesting Sensor (EHS) needs to send data packets arriving in its queue over a fading channel at maximum possible throughput while ensuring acceptable packet delays. At the same time, it needs to ensure that energy neutrality is satisfied, i.e., the average energy drawn from a battery should equal the amount of energy deposited in it minus the energy lost due to the inefficiency of the battery. In this work, a framework is developed under which a system designer can optimize the performance of the EHS node using power control based on the current channel state information, when the EHS node employs a single modulation and coding scheme and the channel is Rayleigh fading. Optimal system parameters for throughput optimal, delay optimal and delay-constrained throughput optimal policies that ensure energy neutrality are derived. It is seen that a throughput optimal (maximal) policy is packet delay-unbounded and an average delay optimal (minimal) policy achieves negligibly small throughput. Finally, the influence of the harvested energy profile on the performance of the EHS is illustrated through the example of solar energy harvesting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents concepts, designs, and working prototypes of enhanced laparoscopic surgical tools. The enhancements are in equipping the tool with force and temperature sensing as well as image acquisition for stereo vision. Just as the pupils of our eyes are adequately spaced out and the distance between them is adjustable, two minute cameras mounted on a mechanism in our design can be moved closer or farther apart inside the inflated abdomen during the surgery. The cameras are fitted to a deployable mechanism consisting of flexural joints so that they can be inserted through a small incision and then deployed and moved as needed.A temperature sensor and a force sensor are mounted on either of the gripping faces of the surgical grasping tool to measure the temperature and gripping force, which need to be controlled for safe laparoscopic surgery. The sensors are small enough and hence they do not cause interference during surgery and insertion.Prototyping and working of the enhanced laparoscopic tool are presented with details