870 resultados para Máquina de indução duplamente alimentada (DFIG)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the control and operation of doubly-fed induction generator (DFIG) and fixed-speed induction generator (FSIG) based wind farms under unbalanced grid conditions. A DFIG system model suitable for analyzing unbalanced operation is developed, and used to assess the impact of an unbalanced supply on DFIG and FSIG operation. Unbalanced voltage at DFIG and FSIG terminals can cause unequal heating on the stator windings, extra mechanical stresses and output power fluctuations. These problems are particularly serious for the FSIG-based wind farm without a power electronic interface to the grid. To improve the stability of a wind energy system containing both DFIG and FSIG based wind farms during network unbalance, a control strategy of unbalanced voltage compensation by the DFIG systems is proposed. The DFIG system compensation ability and the impact of transmission network impedance are illustrated. The simulation results implemented in Matlab/Simulink show that the proposed DFIG control system improves not only its own performance, but also the stability of the FSIG system with the same grid connection point during network unbalance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a decoupled fault ride-through strategy for a doubly fed induction generator (DFIG) to enhance network stability during grid disturbances. The decoupled operation proposes that a DFIG operates as an induction generator (IG) with the converter unit acting as a reactive power source during a fault condition. The transition power characteristics of the DFIG have been analyzed to derive the capability of the proposed strategy under various system conditions. The optimal crowbar resistance is obtained to exploit the maximum power capability from the DFIG during decoupled operation. The methods have been established to ensure proper coordination between the IG mode and reactive power compensation from the grid-side converter during decoupled operation. The viability and benefits of the proposed strategy are demonstrated using different test network structures and different wind penetration levels. Control performance has been benchmarked against existing grid code standards and commercial wind generator systems, based on the optimal network support required (i.e., voltage or frequency) by the system operator from a wind farm installed at a particular location.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. The impact of flicker propagation along the wind farm feeder and effectiveness of the proposed strategy is also evaluated with consumer loads connected to the wind farm feeder. It is shown that voltage variability and short-term flicker severity is significantly reduced following implementation of the novel strategy described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimal fault ride-through (FRT) conditions for a doubly-fed induction generator (DFIG) during a transient grid fault are analyzed with special emphasis on improving the active power generation profile. The transition states due to crowbar activation during transient faults are investigated to exploit the maximum power during the fault and post-fault period. It has been identified that operating slip, severity of fault and crowbar resistance have a direct impact on the power capability of a DFIG, and crowbar resistance can be chosen to optimize the power capability. It has been further shown that an extended crowbar period can deliver enhanced inertial response following the transient fault. The converter protection and drive train dynamics have also been analyzed while choosing the optimum crowbar resistance and delivering enhanced inertial support for an extended crowbar period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The doubly-fed induction generator (DFIG) now represents the dominant technology in wind turbine design. One consequence of this is limited damping and inertial response during transient grid disturbances. A dasiadecoupledpsila strategy is therefore proposed to operate the DFIG grid-side converter (GSC) as a static synchronous compensator (STATCOM) during a fault, supporting the local voltage, while the DFIG operates as a fixed-speed induction generator (FSIG) providing an inertial response. The modeling aspects of the decoupled control strategy, the selection of protection control settings, the significance of the fault location and operation at sub- and super-synchronous speeds are analyzed in detail. In addition, a case study is developed to validate the proposed strategy under different wind penetrations levels. The simulations show that suitable configuration of the decoupled strategy can be deployed to improve system voltage stability and inertial response for a range of scenarios, especially at high wind penetration. The conclusions are placed in context of the practical limitations of the technology employed and the system conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a surrogate-model based optimization of a doubly-fed induction generator (DFIG) machine winding design for maximizing power yield. Based on site-specific wind profile data and the machine’s previous operational performance, the DFIG’s stator and rotor windings are optimized to match the maximum efficiency with operating conditions for rewinding purposes. The particle swarm optimization (PSO)-based surrogate optimization techniques are used in conjunction with the finite element method (FEM) to optimize the machine design utilizing the limited available information for the site-specific wind profile and generator operating conditions. A response surface method in the surrogate model is developed to formulate the design objectives and constraints. Besides, the machine tests and efficiency calculations follow IEEE standard 112-B. Numerical and experimental results validate the effectiveness of the proposed technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mest., Engenharia Eléctrica e Electrónica (Sistemas de Energia e Controlo), Univ. do Algarve, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos Esta monografia, através de uma exaustiva pesquisa, tem como objetivo identificar as principais causas de infertilidade, entender os métodos de reprodução medicamente assistida e explorar as estratégias farmacológicas na indução da ovulação. Métodos Investigou-se a terapêutica da indução/estimulação da ovulação recorrendo a livros e bases de dados online. A pesquisa foi realizada entre Setembro de 2011 e Outubro de 2012. Resultados Após a análise da anatomofisiologia da mulher, causas de infertilidade, o seu diagnóstico e tratamento foram exploradas as várias terapêuticas usadas. A terapêutica usada na indução da ovulação mostrou ser a mais usada e versátil, merecendo destaque neste trabalho. Conclusão São descritas algumas substâncias indutoras da ovulação, exploradas a suas vantagens e desvantagens; comparadas as que tinham um modo semelhante de funcionamento. Contudo ainda devem ser alvo de profunda investigação e ser usados apenas em casos muito específicos, com o acompanhamento médico especializado e constante monotorização.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No presente trabalho apresentam-se dois estudos. O primeiro dos estudos teve como objetivo a adaptação ao português do Inventário de Obsessões e Compulsões de Vancouver (VOCI; Thordarson, Radomsky, Rachman, Shafran, Sawchuk & Hakstian, 2004). O segundo dos estudos teve como objetivo induzir, de forma experimental, a sensação de contaminação mental através da imaginação de uma situação de traição. No estudo de adaptação do VOCI participaram 180 indivíduos da população geral não-clínica com idades compreendidas entre os 18 e os 75 anos e 120 estudantes universitários com idades compreendidas entre os 18 e os 25 anos que preencheram além do VOCI, a Escala de sensibilidade de Contaminação (S-CTN; Rachman, 2006 cit in Coughtrey, Shafran, Knibbs & Rachman, 2012). Sessenta dos participantes completaram de novo o VOCI após um intervalo de 8 semanas. A amostra final ficou constituída por 292 participantes. Para conhecer a estrutura interna do VOCI, foi realizada uma análise fatorial exploratória. Obtiveram-se 6 fatores que explicaram 39% da variância total. Os fatores obtidos replicaram a estrutura original do VOCI Contaminação, Verificação, Obsessões, Acumulação, Incerteza, Just Right. Quer o total do VOCI quer as seis subescalas obtidas mostraram excelentes níveis de consistência interna, fiabilidade temporal e validade convergente. De acordo com os nossos resultados, podemos considerar que a versão portuguesa do VOCI apresenta garantias psicométricas suficientes para que possa ser utilizada na população Portuguesa. No segundo estudo, participaram 60 estudantes universitários, 30 do género feminino e 30 do género masculino, com idades compreendidas entre os 18 e os 25 anos. Os participantes foram aleatoriamente divididos em dois grupos: um grupo de controlo (GC) e um grupo experimental (GE). Neste estudo recorreu-se a um desenho experimental 2x4 (2 condições x 4 momentos). Inicialmente os participantes preencheram um conjunto de questionários e de seguida foram instruídos para ouvir uma gravação de voz relativa à sua condição (controlo/experimental). Posteriormente foi-lhes dada uma pausa de 5 minutos e, no quarto e último momento, os participantes foram submetidos a uma pequena entrevista final. Os resultados obtidos após a manipulação experimental revelaram que o GE apresentou valores significativamente mais elevados de desconforto que o GC, ou seja, a manipulação experimental desencadeou emoções negativas (tais como a raiva ou a tristeza). Não se verificou, no entanto, o efeito da manipulação experimental relativamente à capacidade dos participantes para localizar a sujidade em alguma parte do interior ou exterior do corpo. Em suma, no presente estudo não foi possível induzir contaminação mental através da imaginação de uma situação de traição bem como a localização da sensação de sujidade, o aparecimento de emoções/sentimentos negativos, do impulso de se lavar, de evitamento e de estratégias de neutralização e de lavagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de projecto de mestrado, Ciências da Educação (Formação de Adultos), Universidade de Lisboa, Instituto de Educação, 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)