962 resultados para Long line
Resumo:
BACKGROUND For engineering graduates to be work-ready with marketable skills they must not only be well-versed with engineering science and its applications, but also able to adapt to using commercial software that is widely used in engineering practice. Hydrological/hydraulic modelling is one aspect of engineering practice which demands the ability to apply fundamentals into design and construction using software. The user manuals for such software are usually tailored for the experienced engineer but not for undergraduates who typically are novices to concepts of modelling and software tools. As the focus of a course such as Advanced Water Engineering is on the wider aspects of engineering application of hydrological and hydraulic concepts, it is ineffective for the lecturers to direct the students to user manuals as students have neither the time nor the desire to sift through numerous pages in a manual. An alternative and efficient way to demonstrate the use of the software is enabling students to develop a model to simulate real-world scenario using the tools of the software and directing them to make informed decisions based on outcomes. PURPOSE Past experience of the lecturer showed that the resources available for the students left a knowledge gap leading to numerous student queries outside contact hours. The purpose of this study is to assess how effective purpose-built video resources can be in supplementing the traditional learning resources to enhance student learning. APPROACH Short-length animated video clips comprising guided step-by-step instructions were prepared using screen capture software to capture screen activity and later edited to focus on specific features using pop-up annotations; Vocal narration was purposely excluded to avoid disturbances due to noise and allow different learning paces of individual students. The video clips were made available to the students alongside the traditional resources/approaches such as in-class demonstrations, guideline notes, and tips for efficient and error-free procedural descriptions. The number of queries the lecturer received from the student cohort outside the lecture times was recorded. An anonymous survey to assess the usefulness and adequacy of the courseware was conducted. OUTCOMES While a significant decline in the number of student queries was noted, an overwhelming majority of the survey respondents confirmed the usefulness of the purpose-developed courseware. CONCLUSIONS/RECOMMENDATIONS/SUMMARY The survey and lecturer’s experience indicated that animated demonstration video clips illustrating the various steps involved in developing hydrologic and hydraulic models and simulating design scenarios is an effective supplement for traditional learning resources. Among the many advantages of the custom-made video clips as a learning resource are that they (1) highlight the aspects that are important to undergraduate learning but not available in the software manuals as the latter are designed for more mature users/learners; (2) provide short, to-the point communication in a step-by-step manner; (3) allow students flexibility to self-learn at their own pace; (4) enhance student learning; and (5) enable time savings for the lecturer in the long term by avoiding queries of a repetitive nature. It is expected that these newly developed resources will be improved to incorporate students’ suggestions before being offered to future cohorts of students. The concept can also be expanded to other relevant courses where animated demonstrations of key modelling steps are beneficial to student learning.
Resumo:
Background Guidelines and clinical practice for the prevention of complications associated with central venous catheters (CVC) around the world vary greatly. Most institutions recommend the use of heparin to prevent occlusion, however there is debate regarding the need for heparin and evidence to suggest 0.9% sodium chloride (normal saline) may be as effective. The use of heparin is not without risk, may be unnecessary and is also associated with increased cost. Objectives To assess the clinical effects (benefits and harms) of intermittent flushing of heparin versus normal saline to prevent occlusion in long term central venous catheters in infants and children. Search Methods The Cochrane Vascular Trials Search Co-ordinator searched the Specialised Register (last searched April 2015) and the Cochrane Register of Studies (Issue 3, 2015). We also searched the reference lists of retrieved trials. Selection criteria Randomised controlled trials that compared the efficacy of normal saline with heparin to prevent occlusion of long term CVCs in infants and children aged up to 18 years of age were included. We excluded temporary CVCs and peripherally inserted central catheters (PICC). Data Collection and Analysis Two review authors independently assessed trial inclusion criteria, trial quality and extracted data. Rate ratios were calculated for two outcome measures - occlusion of the CVC and central line-associated blood stream infection. Other outcome measures included duration of catheter placement, inability to withdraw blood from the catheter, use of urokinase or recombinant tissue plasminogen, incidence of removal or re-insertion of the catheter, or both, and other CVC-related complications such as dislocation of CVCs, other CVC site infections and thrombosis. Main Results Three trials with a total of 245 participants were included in this review. The three trials directly compared the use of normal saline and heparin, however, between studies, all used different protocols for the standard and experimental arms with different concentrations of heparin and different frequency of flushes reported. In addition, not all studies reported on all outcomes. The quality of the evidence ranged from low to very low because there was no blinding, heterogeneity and inconsistency between studies was high and the confidence intervals were wide. CVC occlusion was assessed in all three trials (243 participants). We were able to pool the results of two trials for the outcomes of CVC occlusion and CVC-associated blood stream infection. The estimated rate ratio for CVC occlusion per 1000 catheter days between the normal saline and heparin group was 0.75 (95% CI 0.10 to 5.51, two studies, 229 participants, very low quality evidence). The estimated rate ratio for CVC-associated blood stream infection was 1.48 (95% CI 0.24 to 9.37, two studies, 231 participants; low quality evidence). The duration of catheter placement was reported to be similar between the two study arms, in one study (203 participants). Authors' Conclusions The review found that there was not enough evidence to determine the effects of intermittent flushing of heparin versus normal saline to prevent occlusion in long term central venous catheters in infants and children. Ultimately, if this evidence were available, the development of evidenced-based clinical practice guidelines and consistency of practice would be facilitated.
Resumo:
Objectives In 2012, the National Institute for Health and Care Excellence assessed dasatinib, nilotinib, and standard-dose imatinib as first-line treatment of chronic phase chronic myelogenous leukemia (CML). Licensing of these alternative treatments was based on randomized controlled trials assessing complete cytogenetic response (CCyR) and major molecular response (MMR) at 12 months as primary end points. We use this case study to illustrate the validation of CCyR and MMR as surrogate outcomes for overall survival in CML and how this evidence was used to inform National Institute for Health and Care Excellence’s recommendation on the public funding of these first-line treatments for CML. Methods We undertook a systematic review and meta-analysis to quantify the association between CCyR and MMR at 12 months and overall survival in patients with chronic phase CML. We estimated life expectancy by extrapolating long-term survival from the weighted overall survival stratified according to the achievement of CCyR and MMR. Results Five studies provided data on the observational association between CCyR or MMR and overall survival. Based on the pooled association between CCyR and MMR and overall survival, our modeling showed comparable predicted mean duration of survival (21–23 years) following first-line treatment with imatinib, dasatinib, or nilotinib. Conclusions This case study illustrates the consideration of surrogate outcome evidence in health technology assessment. Although it is often recommended that the acceptance of surrogate outcomes be based on randomized controlled trial data demonstrating an association between the treatment effect on both the surrogate outcome and the final outcome, this case study shows that policymakers may be willing to accept a lower level of evidence (i.e., observational association).
Resumo:
Introduction Metastatic spread to the brain is common in patients with non–small cell lung cancer (NSCLC), but these patients are generally excluded from prospective clinical trials. The studies, phase III study of afatinib or cisplatin plus pemetrexed in patients with metastatic lung adenocarcinoma with EGFR mutations (LUX-Lung 3) and a randomized, open-label, phase III study of BIBW 2992 versus chemotherapy as first-line treatment for patients with stage IIIB or IV adenocarcinoma of the lung harbouring an EGFR activating mutation (LUX-Lung 6) investigated first-line afatinib versus platinum-based chemotherapy in epidermal growth factor receptor gene (EGFR) mutation-positive patients with NSCLC and included patients with brain metastases; prespecified subgroup analyses are assessed in this article. Methods For both LUX-Lung 3 and LUX-Lung 6, prespecified subgroup analyses of progression-free survival (PFS), overall survival, and objective response rate were undertaken in patients with asymptomatic brain metastases at baseline (n = 35 and n = 46, respectively). Post hoc analyses of clinical outcomes was undertaken in the combined data set (n = 81). Results In both studies, there was a trend toward improved PFS with afatinib versus chemotherapy in patients with brain metastases (LUX-Lung 3: 11.1 versus 5.4 months, hazard ratio [HR] = 0.54, p = 0.1378; LUX-Lung 6: 8.2 versus 4.7 months, HR = 0.47, p = 0.1060). The magnitude of PFS improvement with afatinib was similar to that observed in patients without brain metastases. In combined analysis, PFS was significantly improved with afatinib versus with chemotherapy in patients with brain metastases (8.2 versus 5.4 months; HR, 0.50; p = 0.0297). Afatinib significantly improved the objective response rate versus chemotherapy in patients with brain metastases. Safety findings were consistent with previous reports. Conclusions These findings lend support to the clinical activity of afatinib in EGFR mutation–positive patients with NSCLC and asymptomatic brain metastases.
Resumo:
The third edition of the Australian Standard AS1742 Manual of Uniform Traffic Control Devices Part 7 provides a method of calculating the sighting distance required to safely proceed at passive level crossings based on the physics of moving vehicles. This required distance becomes greater with higher line speeds and slower, heavier vehicles so that it may return quite a long sighting distance. However, at such distances, there are also concerns around whether drivers would be able to reliably identify a train in order to make an informed decision regarding whether it would be safe to proceed across the level crossing. In order to determine whether drivers are able to make reliable judgements to proceed in these circumstances, this study assessed the distance at which a train first becomes identifiable to a driver as well as their, ability to detect the movement of the train. A site was selected in Victoria, and 36 participants with good visual acuity observed 4 trains in the 100-140 km/h range. While most participants could detect the train from a very long distance (2.2 km on average), they could only detect that the train was moving at much shorter distances (1.3 km on average). Large variability was observed between participants, with 4 participants consistently detecting trains later than other participants. Participants tended to improve in their capacity to detect the presence of the train with practice, but a similar trend was not observed for detection of the movement of the train. Participants were consistently poor at accurately judging the approach speed of trains, with large underestimations at all investigated distances.
Resumo:
Transmission of bulk power at high voltages over very long distances has become very imperative. At present, throughout the globe, this task has been mostly performed by overhead transmission lines. The dual task of mechanically supporting and electrically isolating the live phase conductors from the support tower is performed by string insulators. Whether in clean condition or under polluted conditions, the electrical stress distribution along the insulators governs the possible flashover, which is quite detrimental to the system. However, a reliable data on stress distribution in commonly employed string insulators are rather scarce. Considering this, the present work has made an attempt to study accurately, the field distribution in 220 kV strings for six different types of porcelain/ceramic insulators (Normal and Antifog discs) used for high voltage transmission. The surface charge simulation method is employed for the required field computation. Voltage and electric stress distribution is deduced and compared across different types of discs. A comparison on normalised surface resistance, which is an indicator for the stress concentration under polluted condition, is also attempted.
Resumo:
The effectiveness of series capacitors used with long distance transmission lines in improving system stability is analyzed. Compensation efficiency is defined as the effectiveness of series capacitors. The influence of various factors on compensation efficiency such as capacitor location, line length, and degree of series compensation is investigated. Proper use of shunt reactors with series capacitors, in addition to limiting power frequency over- voltages, increases the maximum power transfer. Analytical expressions are included to aid in the calculation of compensation efficiency for a few typical cases. Curves are also presented indicating the critical value of shunt Mvar required for various degrees of series compensation and line lengths.
Resumo:
This paper presents a fast and accurate relaying technique for a long 765kv UHV transmission line based on support vector machine. For a long EHV/UHV transmission line with large distributed capacitance, a traditional distance relay which uses a lumped parameter model of the transmission line can cause malfunction of the relay. With a frequency of 1kHz, 1/4th cycle of instantaneous values of currents and voltages of all phases at the relying end are fed to Support Vector Machine(SVM). The SVM detects fault type accurately using 3 milliseconds of post-fault data and reduces the fault clearing time which improves the system stability and power transfer capability. The performance of relaying scheme has been checked with a typical 765kV Indian transmission System which is simulated using the Electromagnetic Transients Program(EMTP) developed by authors in which the distributed parameter line model is used. More than 15,000 different short circuit fault cases are simulated by varying fault location, fault impedance, fault incidence angle and fault type to train the SVM for high speed accurate relaying. Simulation studies have shown that the proposed relay provides fast and accurate protection irrespective of fault location, fault impedance, incidence time of fault and fault type. And also the proposed scheme can be used as augmentation for the existing relaying, particularly for Zone-2, Zone-3 protection.
Resumo:
Eu+3 was incorporated into the lattice of a lead-free ferroelectric Na1/2Bi1/2TiO3 (NBT) as per the nominal formula Na0.5Bi0.5-xEuxTiO3. This system was investigated with regard to the Eu+3 photoluminescence (PL) and structural behaviour as a function of composition and electric field. Electric field was found to irreversibly change the features in the PL spectra and also in the x-ray diffraction patterns below the critical composition x = 0.025. Detailed analysis revealed that below the critical composition, electric field irreversibly suppresses the structural heterogeneity inherent of the host matrix NBT and brings about a long range ferroelectric state with rhombohedral (R3c) distortion. It is shown that the structural disorder on the nano-scale opens a new channel for radiative transition which manifests as a new emission line branching off from the main D-5(0)-> F-7(0) line along with a concomitant change in the relative intensity of the other crystal field induced Stark lines with different J values. The study suggests that Eu+3 luminescence can be used to probe the relative degree of field induced structural ordering in relaxor ferroelectrics and also in high performance piezoelectric alloys where electric field couples very strongly with the lattice and structural degrees of freedom. (C) 2015 AIP Publishing LLC.
Resumo:
[En]The present study aimed at investigating the existence of long memory properties in ten developed stock markets across the globe. When return series exhibit long memory, the series realizations are not independent over time and past returns can help predict future returns, thus violating the market efficiency hypothesis. It poses a serious challenge to the supporters of random walk behavior of the stock returns indicating a potentially predictable component in the series dynamics. We computed Hurst-Mandelbrot’s Classical R/S statistic, Lo’s statistic and semi parametric GPH statistic using spectral regression. The findings suggest existence of long memory in volatility and random walk for logarithmic return series in general for all the selected stock market indices. Findings are in line with the stylized facts of financial time series.
Resumo:
The dynamics of long slender cylinders undergoing vortex-induced vibrations (VIV) is studied in this work. Long slender cylinders such as risers or tension legs are widely used in the field of ocean engineering. When the sea current flows past a cylinder, it will be excited due to vortex shedding. A three-dimensional time domain model is formulated to describe the response of the cylinder, in which the in-line (IL) and cross-flow (CF) deflections are coupled. The wake dynamics, including in-line and cross-flow vibrations, is represented using a pair of non-linear oscillators distributed along the cylinder. The wake oscillators are coupled to the dynamics of the long cylinder with the acceleration coupling term. A non-linear fluid force model is accounted for to reflect the relative motion of cylinder to current. The model is validated against the published data from a tank experiment with the free span riser. The comparisons show that some aspects due to VIV of long flexible cylinders can be reproduced by the proposed model, such as vibrating frequency, dominant mode number, occurrence and transition of the standing or traveling waves. In the case study, the simulations show that the IL curvature is not smaller than CF curvature, which indicates that both IL and CF vibrations are important for the structural fatigue damage.
Resumo:
The nearshore waters along the Myrtle Beach area are oceanographically referred to as Long Bay. Long Bay is the last in a series of semi-circular indentations located along the South Atlantic seaboard. The Bay extends for approximately 150 km from the Cape Fear River in North Carolina to Winyah Bay in South Carolina and has a number of small inlets (Figure 1). This region of the S.C. coast, commonly referred to as the “Grand Strand,” has a significant tourism base that accounts for a substantial portion of the South Carolina economy (i.e., 40% of the state’s total in 2002) (TIAA 2003). In 2004, the Grand Strand had an estimated 13.2 million visitors of which 90% went to the beach (MBCC 2006). In addition, Long Bay supports a shore-based hook and line fishery comprised of anglers fishing from recreational fishing piers, the beach, and small recreational boats just offshore. (PDF contains 4 pages)
Resumo:
Many applications in cosmology and astrophysics at millimeter wavelengths including CMB polarization, studies of galaxy clusters using the Sunyaev-Zeldovich effect (SZE), and studies of star formation at high redshift and in our local universe and our galaxy, require large-format arrays of millimeter-wave detectors. Feedhorn and phased-array antenna architectures for receiving mm-wave light present numerous advantages for control of systematics, for simultaneous coverage of both polarizations and/or multiple spectral bands, and for preserving the coherent nature of the incoming light. This enables the application of many traditional "RF" structures such as hybrids, switches, and lumped-element or microstrip band-defining filters.
Simultaneously, kinetic inductance detectors (KIDs) using high-resistivity materials like titanium nitride are an attractive sensor option for large-format arrays because they are highly multiplexable and because they can have sensitivities reaching the condition of background-limited detection. A KID is a LC resonator. Its inductance includes the geometric inductance and kinetic inductance of the inductor in the superconducting phase. A photon absorbed by the superconductor breaks a Cooper pair into normal-state electrons and perturbs its kinetic inductance, rendering it a detector of light. The responsivity of KID is given by the fractional frequency shift of the LC resonator per unit optical power.
However, coupling these types of optical reception elements to KIDs is a challenge because of the impedance mismatch between the microstrip transmission line exiting these architectures and the high resistivity of titanium nitride. Mitigating direct absorption of light through free space coupling to the inductor of KID is another challenge. We present a detailed titanium nitride KID design that addresses these challenges. The KID inductor is capacitively coupled to the microstrip in such a way as to form a lossy termination without creating an impedance mismatch. A parallel plate capacitor design mitigates direct absorption, uses hydrogenated amorphous silicon, and yields acceptable noise. We show that the optimized design can yield expected sensitivities very close to the fundamental limit for a long wavelength imager (LWCam) that covers six spectral bands from 90 to 400 GHz for SZE studies.
Excess phase (frequency) noise has been observed in KID and is very likely caused by two-level systems (TLS) in dielectric materials. The TLS hypothesis is supported by the measured dependence of the noise on resonator internal power and temperature. However, there is still a lack of a unified microscopic theory which can quantitatively model the properties of the TLS noise. In this thesis we derive the noise power spectral density due to the coupling of TLS with phonon bath based on an existing model and compare the theoretical predictions about power and temperature dependences with experimental data. We discuss the limitation of such a model and propose the direction for future study.
Resumo:
We introduce a four-pass laser pulse compressor design based on two grating apertures with two gratings per aperture that is tolerant to some alignment errors and, importantly, to grating-to-grating period variations. Each half-beam samples each grating in a diamond-shaped compressor that is symmetric about a central bisecting plane. For any given grating, the two half-beams impinge on opposite sides of its surface normal. It is shown that the two split beams have no pointing difference from paired gratings with different periods. Furthermore, no phase shift between half-beams is incurred as long as the planes containing a grating line and the surface normal for each grating of the pair are parallel. For grating pairs satisfying this condition, gratings surfaces need not be on the same plane, as changes in the gap between the two can compensate to bring the beams back in phase. © 2008 Optical Society of America.
Resumo:
Long-term settlement of tunnels has caused concerns about its influence on tunnel safety and serviceability. Aiming to investigate the long-term behaviour of tunnels against the background of Shanghai metro line, two cases of centrifuge modelling were conducted, with efforts to expose the mechanism affecting the consolidation of the ground. Evenly layered ground and transitional ground strata were set for each case separately and the settlement, lining load and pore water pressure were checked against elapsed time up to 20 years. The results verified some previous findings concerning the settlement and lining load development trend, however, it was also shown that the transitional ground made the tunnel response more complicated. The research is expected to provide some basis for further research on other affecting factors, such as lining permeability. © 2010 Taylor & Francis Group, London.