984 resultados para Liquid-storage tanks
Resumo:
Natural hazards affecting industrial installations could directly or indirectly cause an accident or series of accidents with serious consequences for the environment and for human health. Accidents initiated by a natural hazard or disaster which result in the release of hazardous materials are commonly referred to as Natech (Natural Hazard Triggering a Technological Disaster) accidents. The conditions brought about by these kinds of events are particularly problematic, the presence of the natural event increases the probability of exposition and causes consequences more serious than standard technological accidents. Despite a growing body of research and more stringent regulations for the design and operation of industrial activities, Natech accidents remain a threat. This is partly due to the absence of data and dedicated risk-assessment methodologies and tools. Even the Seveso Directives for the control of risks due to major accident hazards do not include any specific impositions regarding the management of Natech risks in the process industries. Among the few available tools there is the European Standard EN 62305, which addresses generic industrial sites, requiring to take into account the possibility of lightning and to select the appropriate protection measures. Since it is intended for generic industrial installations, this tool set the requirements for the design, the construction and the modification of structures, and is thus mainly oriented towards conventional civil building. A first purpose of this project is to study the effects and the consequences on industrial sites of lightning, which is the most common adverse natural phenomenon in Europe. Lightning is the cause of several industrial accidents initiated by natural causes. The industrial sectors most susceptible to accidents triggered by lightning is the petrochemical one, due to the presence of atmospheric tanks (especially floating roof tanks) containing flammable vapors which could be easily ignited by a lightning strike or by lightning secondary effects (as electrostatic and electromagnetic pulses or ground currents). A second purpose of this work is to implement the procedure proposed by the European Standard on a specific kind of industrial plant, i.e. on a chemical factory, in order to highlight the critical aspects of this implementation. A case-study plant handling flammable liquids was selected. The application of the European Standard allowed to estimate the incidence of lightning activity on the total value of the default release frequency suggested by guidelines for atmospheric storage tanks. Though it has become evident that the European Standard does not introduce any parameters explicitly pointing out the amount of dangerous substances which could be ignited or released. Furthermore the parameters that are proposed to describe the characteristics of the structures potentially subjected to lightning strikes are insufficient to take into account the specific features of different chemical equipment commonly present in chemical plants.
Resumo:
Two of the indicators of the UN Millennium Development Goals ensuring environmental sustainability are energy use and per capita carbon dioxide emissions. The increasing urbanization and increasing world population may require increased energy use in order to transport enough safe drinking water to communities. In addition, the increase in water use would result in increased energy consumption, thereby resulting in increased green-house gas emissions that promote global climate change. The study of multiple Municipal Drinking Water Distribution Systems (MDWDSs) that relates various MDWDS aspects--system components and properties--to energy use is strongly desirable. The understanding of the relationship between system aspects and energy use aids in energy-efficient design. In this study, components of a MDWDS, and/or the characteristics associated with the component are termed as MDWDS aspects (hereafter--system aspects). There are many aspects of MDWDSs that affect the energy usage. Three system aspects (1) system-wide water demand, (2) storage tank parameters, and (3) pumping stations were analyzed in this study. The study involved seven MDWDSs to understand the relationship between the above-mentioned system aspects in relation with energy use. A MDWDSs model, EPANET 2.0, was utilized to analyze the seven systems. Six of the systems were real and one was a hypothetical system. The study presented here is unique in its statistical approach using seven municipal water distribution systems. The first system aspect studied was system-wide water demand. The analysis involved analyzing seven systems for the variation of water demand and its impact on energy use. To quantify the effects of water use reduction on energy use in a municipal water distribution system, the seven systems were modeled and the energy usage quantified for various amounts of water conservation. It was found that the effect of water conservation on energy use was linear for all seven systems and that all the average values of all the systems' energy use plotted on the same line with a high R 2 value. From this relationship, it can be ascertained that a 20% reduction in water demand results in approximately a 13% savings in energy use for all seven systems analyzed. This figure might hold true for many similar systems that are dominated by pumping and not gravity driven. The second system aspect analyzed was storage tank(s) parameters. Various tank parameters: (1) tank maximum water levels, (2) tank elevation, and (3) tank diameter were considered in this part of the study. MDWDSs use a significant amount of electrical energy for the pumping of water from low elevations (usually a source) to higher ones (usually storage tanks). The use of electrical energy has an effect on pollution emissions and, therefore, potential global climate change as well. Various values of these tank parameters were modeled on seven MDWDSs of various sizes using a network solver and the energy usage recorded. It was found that when averaged over all seven analyzed systems (1) the reduction of maximum tank water level by 50% results in a 2% energy reduction, (2) energy use for a change in tank elevation is system specific, and (2) a reduction of tank diameter of 50% results in approximately a 7% energy savings. The third system aspect analyzed in this study was pumping station parameters. A pumping station consists of one or more pumps. The seven systems were analyzed to understand the effect of the variation of pump horsepower and the number of booster stations on energy use. It was found that adding booster stations could save energy depending upon the system characteristics. For systems with flat topography, a single main pumping station was found to use less energy. In systems with a higher-elevation neighborhood, however, one or more booster pumps with a reduced main pumping station capacity used less energy. The energy savings for the seven systems was dependent on the number of boosters and ranged from 5% to 66% for the analyzed five systems with higher elevation neighborhoods (S3, S4, S5, S6, and S7). No energy savings was realized for the remaining two flat topography systems, S1, and S2. The present study analyzed and established the relationship between various system aspects and energy use in seven MDWDSs. This aids in estimating the amount of energy savings in MDWDSs. This energy savings would ultimately help reduce Greenhouse gases (GHGs) emissions including per capita CO 2 emissions thereby potentially lowering the global climate change effect. This will in turn contribute to meeting the MDG of ensuring environmental sustainability.
Resumo:
ENAGAS tiene la intención de ampliar el Terminal de Regasificación de GNL que tiene en el puerto de Barcelona. El presente Proyecto Básico define las instalaciones de uno de los Tanques de almacenamiento de GNL que se van a construir dentro del Alcance de dicha ampliación, con el suficiente detalle como para permitir a ENAGAS acometer las tareas previas a la ejecución del proyecto, a saber: 1. Planificar y presupuestar la fase de ejecución 2. Solicitar los Permisos y Autorizaciones necesarias de los Organismos competentes 3. Lanzar la Petición de Ofertas para el concurso llave en mano del EPC. Los trabajos de Ingeniería contenidos en el Proyecto Básico son los siguientes: Antecedentes y Datos básicos, Criterios de diseño, Descripción de instalaciones, Cálculos estructurales, Planos del Tanque de GNL, Definición de equipos y materiales a utilizar, Plan de ejecución del proyecto, Especificaciones técnicas para Ingeniería, Compras y Construcción, Paquete para Petición de Ofertas del EPC, Condiciones técnicas particulares, Programa de ejecución y Presupuesto de inversiones. ABSTRACT ENAGAS is expanding its LNG Regasification Terminal located in Barcelona Port (Spain). This Document reports the Front End Engineering and Design (FEED) works undertaken in relation to one of the LNG Storage Tanks to be built within the scope of that expansion. The Project FEED hereby presented comprehensively defines the LNG Storage Tank so as to allow ENAGAS to perform next stages of the Works, namely: 1. Plan and budget the Project Execution phase 2. Request Regulatory authorizations 3. Invite Contractors to bid for the LNG Tank EPC. Main components of the FEED Document contents are as follow:Background and Basic Data, Design Criteria, Description of LNG Tank elements, Engineering Calculations, LNG Tank Drawings, Equipment and Materials definition, Project Execution Plan (PEP), Technical Conditions, EPC Invitation to Tender (ITT) package, Execution Schedule and Cost Estimate.
Resumo:
Los procesos relacionados con el almacenamiento y manipulación de productos petrolíferos, conllevan siempre determinados riesgos de incendio que dependen básicamente de las propiedades físicas y químicas de los productos, y hacen indispensable la adopción de importantes medidas de seguridad contra incendios. Esto es debido a que las consecuencias previsibles en caso de la producción y expansión del incendio son tan graves que aconsejan la instalación de medios más potentes de lucha contra incendios, que los simples extintores manuales. En base a ello, el presente proyecto pretende definir y desarrollar una propuesta de diseño del sistema de protección contra incendios en la zona de almacenamiento de una planta de almacenamiento de líquidos petrolíferos. La planta almacena Gasóleo, Gasolina y Queroseno de Aviación en ocho tanques atmosféricos de techo fijo situados en un único cubeto de retención. Se desarrolla un extenso estudio de los requisitos normativos para este tipo de casos, y en consecuencia, se calcula y clasifica el nivel de riesgo intrínseco de incendio en la zona estudiada, a partir de su carga de fuego ponderada y corregida. Además, se muestra la distribución de los tanques en el cubeto, basada en el cálculo de las distancias de seguridad entre cada uno de ellos y con el exterior. A partir de ello, el proyecto se centra en el cálculo de los valores de descarga de agua de refrigeración, requeridos en las boquillas de agua pulverizada e hidrantes exteriores de alrededor de la zona de riesgo; de espuma física para hidrocarburos, en las cámaras de espuma de la parte superior de la envolvente de los tanques, y en los monitores auxiliares de descarga de espuma, de la zona del cubeto de retención. Los objetivos, métodos y bases de cálculo se recogen en la memoria del proyecto. Además se incluye, la planificación temporal con MS Project, de la implementación del proyecto; la elección de los equipos que componen los sistemas, el presupuesto asociado y los planos de distribución de la planta y del flujo de tuberías propuesto. ABSTRACT Fire protection units and equipment are necessary on processes and operations related to storage and handling of petroleum products, because of their flammable and combustible properties. In case a hazard of fire from petroleum products is materialized, huge consequences are to be expected. To reduce losses, facilities should be equipped with appropriate protection. Based on that, this project seeks to define and develop the fire protection system design for a petroleum liquids storage installation. The plant stores Gasoil, Gasoline, and aviation Kerosene in eight fixed roof atmospheric tanks. A complete study of the fire protection regulations is carried out and, as a result, the studied area’s risk level is determined from its fire load density. The calculation of the minimum shell-to-shell spacing of adjacent aboveground storage tanks and external equipment, is also determined for a correct distribution of tanks in the bunded area. Assuming that, the design includes calculations of required discharge of water for spray nozzles and hydrants, and required discharge of foam from foam chambers and foam monitors. Objectives, methodology and calculation basis are presented on the project technical report; which also includes project scheduling with MS. Project software, the selection of system components and equipment, related budget and lay out of installation and piping.
Resumo:
Este trabalho apresenta uma investigação experimental sobre o comportamento à fratura frágil de aços estruturais ferríticos, ASTM A285 Gr C e ASTM A515 Gr 65. Os resultados deste trabalho ampliam a base de dados de propriedades mecânicas utilizadas nas análises de integridade de estruturas pressurizadas tais como vasos de pressão e tanques de armazenamento construídos com esta classe de material. O trabalho tem por objetivo também avaliar a aplicabilidade de corpos de prova de dimensões reduzidas, PCVN, na determinação da temperatura de referência, T0, por meio da metodologia da Curva Mestra, a qual define a dependência da tenacidade à fratura do material em função da temperatura. Os ensaios de tenacidade à fratura foram conduzidos utilizando-se corpos de prova solicitados em flexão três pontos com geometria SE(B), PCVN e PCVN com entalhe lateral, extraídos de chapas laminadas. Os resultados dos ensaios foram obtidos em termos de integral J no momento da instabilidade, denotados por Jc. Dados adicionais de resistência à tração e de Impacto Charpy convencional também foram obtidos para caracterizar o comportamento mecânico dos aços utilizados. Os resultados mostraram uma forte influência da geometria dos corpos de prova sobre os valores de Jc, evidenciada pela grande variação nos valores de tenacidade à fratura.
Resumo:
Mode of access: Internet.
Resumo:
The following activities are specifically identified as ineligible. 1. Design Engineering costs of water storage tanks/towers. 2. Construction of buildings, or portions thereof, used predominantly for the general conduct of government (e.g., city halls, courthouses, jails, police stations). 3. General government expenses. 4. Costs of operating and maintaining public facilities and services (e.g., mowing parks, replacing street light bulbs). 5. Servicing or refinancing of existing debt.
Resumo:
"Spring 1990."
Resumo:
"June 30, 1987."
Resumo:
"30 November 1978."
Resumo:
From October 2014 to March 2015, I provided excavation oversight services at a property with substantial environmental concerns. The property in question is located near downtown Seattle and was formerly occupied by the Washington’s first coal gasification plant. The plant operated from 1888 to 1908 and produced coal gas for municipal use. A coal tar like substance with a characteristically high benzene concentration was a byproduct of the coal gasification process and heavily contaminated at or below the surface grade of the plant as shown in previous investigations on the property. Once the plant ceased operation in 1908 the property was left vacant until 1955 when the site was filled in and a service station was built on the property. The main goal of the excavation was not to achieve cleanup on the property, but to properly remove what contaminated soil was encountered during the redevelopment excavation. Areas of concern were identified prior to the commencement of the excavation and an estimation of the extent of contamination on the property was developed. “Hot spots” of contaminated soil associated with the fill placed after 1955 were identified as areas of concern. However, the primary contaminant plume below the property was likely sourced from the coal gasification plant, which operated at an approximate elevation of 20 feet. We planned to constrain the extents of the soil contamination below the property as the redevelopment excavation progressed. As the redevelopment excavation was advanced down to an elevation of approximately 20 feet, soil samples were collected to bound the extents of contamination in the upper portion of the site. The hot spots, known pockets of carcinogenic polycyclic aromatic hydrocarbons (cPAH) located above 20 feet elevation, were excavated as part of the redevelopment excavation. Once a hot spot was excavated, soil samples were collected from the north, south, east, west and bottom sidewalls of the hot spot excavation to check for remaining cPAH. Additionally, four underground storage tanks (USTs) associated with the service station were discovered and subsequently removed. Soil samples were also collected from the resulting UST excavation sidewalls to check for remaining petroleum hydrocarbons. Once the excavation reached its final excavation depth of 20 to 16 feet in elevation, bottom of excavation samples were collected on a 35 foot by 35 foot grid to test for concentrations of contaminants remaining onsite. Once the redevelopment excavation was complete, soils observed from borings drilled for either structural elements, geotechnical wells, or environmental wells were checked for any evidence of contamination using field screening techniques. Evidence of contamination was used to identify areas below the final excavation grade which had been impacted by the operation of the coal gasification plant. Samples collected from the excavation extents of hot spots and USTs show that it was unlikely that any contamination traveled from the post-1955 grade down to the pre-1955 grade. Additionally, the lack of benzene in the bottom of excavation samples suggests that a release from the coal gasification plant occurred below the redevelopment excavation final elevations of 20 to 16 feet. Qualitative data collected from borings for shoring elements and wells indicated that the spatial extent of the subsurface contaminant plume was different than initially estimated. Observations of spoils show that soil contamination extends further to the southwest and not as far to the east and north than originally estimated. Redefining the extent of the soil contamination beneath the property will allow further subsurface investigations to focus on collecting quantitative data in areas that still represent data gaps on the property, and passing over areas that have shown little signs of contamination. This information will help with the formation of a remediation plan should the need to clean up the site arise in the future.
Resumo:
The aim of the investigation was to study the problem of colonization of shipboard fuel systems and to examine the effect of a number of environmental factors on microbial growth and survival in order to find potential preservative treatments. A variety of microbial species were isolated from samples taken from fuel storage tanks. Bacteria were more numerous than yeasts or fungi and most microorganisms were found at the fuel/water interface. 1he salinity, pH and phosphate concentration of some water bottoms were characteristic of sea water. Others were brackish, acidic and varied in phosphate content. Microorganisms were cultured under a number of environmental conditions. After prolonged incubation, the inoculum size had no effect on the final biomass of Cladosporium resinae but the time required to achieve the final mass decreased with increasing spore number. Undecane supported better growth of the fungus than diesel fuel and of four types of diesel fuel, two allowed more profuse growth. With sea water as the aqueous phase, a number of isolates were inhibited but the addition of nutrients allowed the development of many of the organisms. Agitation increased the growth of C. resinae on glucose but inhibited it on hydrocarbons. The optimum temperature fgr growth of C. resinae on surface culture lay between 25º C and 30º C and growth was evident at 5º C but not at 45º C. In aqueous suspension, 90% of spores were inactivated in around 60 hours at 45ºC and the same proportion of spores of C. resinae and Penicillium corylophilum were destroyed after about 30 seconds at 65ºC. The majority of bacteria and all yeasts in a water bottom sample were killed within 10 seconds at this temperature. An increase in the concentration of an organo-boron compound caused more rapid inactivation of C. resinae spores and raising the temperature from 25ºC to 45°C significantly enhanced the potency of the biocide.
Resumo:
In many areas of northern India, salinity renders groundwater unsuitable for drinking and even for irrigation. Though membrane treatment can be used to remove the salt, there are some drawbacks to this approach e.g. (1) depletion of the groundwater due to over-abstraction, (2) saline contamination of surface water and soil caused by concentrate disposal and (3) high electricity usage. To address these issues, a system is proposed in which a photovoltaic-powered reverse osmosis (RO) system is used to irrigate a greenhouse (GH) in a stand-alone arrangement. The concentrate from the RO is supplied to an evaporative cooling system, thus reducing the volume of the concentrate so that finally it can be evaporated in a pond to solid for safe disposal. Based on typical meteorological data for Delhi, calculations based on mass and energy balance are presented to assess the sizing and cost of the system. It is shown that solar radiation, freshwater output and evapotranspiration demand are readily matched due to the approximately linear relation among these variables. The demand for concentrate varies independently, however, thus favouring the use of a variable recovery arrangement. Though enough water may be harvested from the GH roof to provide year-round irrigation, this would require considerable storage. Some practical options for storage tanks are discussed. An alternative use of rainwater is in misting to reduce peak temperatures in the summer. An example optimised design provides internal temperatures below 30EC (monthly average daily maxima) for 8 months of the year and costs about €36,000 for the whole system with GH floor area of 1000 m2 . Further work is needed to assess technical risks relating to scale-deposition in the membrane and evaporative pads, and to develop a business model that will allow such a project to succeed in the Indian rural context.
Resumo:
This paper presents an assessment of the technical and economic performance of thermal processes to generate electricity from a wood chip feedstock by combustion, gasification and fast pyrolysis. The scope of the work begins with the delivery of a wood chip feedstock at a conversion plant and ends with the supply of electricity to the grid, incorporating wood chip preparation, thermal conversion, and electricity generation in dual fuel diesel engines. Net generating capacities of 1–20 MWe are evaluated. The techno-economic assessment is achieved through the development of a suite of models that are combined to give cost and performance data for the integrated system. The models include feed pretreatment, combustion, atmospheric and pressure gasification, fast pyrolysis with pyrolysis liquid storage and transport (an optional step in de-coupled systems) and diesel engine or turbine power generation. The models calculate system efficiencies, capital costs and production costs. An identical methodology is applied in the development of all the models so that all of the results are directly comparable. The electricity production costs have been calculated for 10th plant systems, indicating the costs that are achievable in the medium term after the high initial costs associated with novel technologies have reduced. The costs converge at the larger scale with the mean electricity price paid in the EU by a large consumer, and there is therefore potential for fast pyrolysis and diesel engine systems to sell electricity directly to large consumers or for on-site generation. However, competition will be fierce at all capacities since electricity production costs vary only slightly between the four biomass to electricity systems that are evaluated. Systems de-coupling is one way that the fast pyrolysis and diesel engine system can distinguish itself from the other conversion technologies. Evaluations in this work show that situations requiring several remote generators are much better served by a large fast pyrolysis plant that supplies fuel to de-coupled diesel engines than by constructing an entire close-coupled system at each generating site. Another advantage of de-coupling is that the fast pyrolysis conversion step and the diesel engine generation step can operate independently, with intermediate storage of the fast pyrolysis liquid fuel, increasing overall reliability. Peak load or seasonal power requirements would also benefit from de-coupling since a small fast pyrolysis plant could operate continuously to produce fuel that is stored for use in the engine on demand. Current electricity production costs for a fast pyrolysis and diesel engine system are 0.091/kWh at 1 MWe when learning effects are included. These systems are handicapped by the typical characteristics of a novel technology: high capital cost, high labour, and low reliability. As such the more established combustion and steam cycle produces lower cost electricity under current conditions. The fast pyrolysis and diesel engine system is a low capital cost option but it also suffers from relatively low system efficiency particularly at high capacities. This low efficiency is the result of a low conversion efficiency of feed energy into the pyrolysis liquid, because of the energy in the char by-product. A sensitivity analysis has highlighted the high impact on electricity production costs of the fast pyrolysis liquids yield. The liquids yield should be set realistically during design, and it should be maintained in practice by careful attention to plant operation and feed quality. Another problem is the high power consumption during feedstock grinding. Efficiencies may be enhanced in ablative fast pyrolysis which can tolerate a chipped feedstock. This has yet to be demonstrated at commercial scale. In summary, the fast pyrolysis and diesel engine system has great potential to generate electricity at a profit in the long term, and at a lower cost than any other biomass to electricity system at small scale. This future viability can only be achieved through the construction of early plant that could, in the short term, be more expensive than the combustion alternative. Profitability in the short term can best be achieved by exploiting niches in the market place and specific features of fast pyrolysis. These include: •countries or regions with fiscal incentives for renewable energy such as premium electricity prices or capital grants; •locations with high electricity prices so that electricity can be sold direct to large consumers or generated on-site by companies who wish to reduce their consumption from the grid; •waste disposal opportunities where feedstocks can attract a gate fee rather than incur a cost; •the ability to store fast pyrolysis liquids as a buffer against shutdowns or as a fuel for peak-load generating plant; •de-coupling opportunities where a large, single pyrolysis plant supplies fuel to several small and remote generators; •small-scale combined heat and power opportunities; •sales of the excess char, although a market has yet to be established for this by-product; and •potential co-production of speciality chemicals and fuel for power generation in fast pyrolysis systems.
Resumo:
The primary purpose of this thesis was to design and create an Interactive Audit to conduct Environmental Site Assessments according to American Society of Testing Material's (ASTM) Phase I Standards at the Wagner Creek study area. ArcPad and ArcIMS are the major software that were used to create the model and ArcGIS Desktop was used for data analysis and to export shapefile symbology to ArcPad. Geographic Information Systems (GIS) is an effective tool to deploy these purposes. This technology was utilized to carry out data collection, data analysis and to display data interactively on the Internet. Electronic forms, customized for mobile devices were used to survey sites. This is an easy and fast way to collect and modify field data. New data such as land use, recognized environmental conditions, and underground storage tanks can be added into existing datasets. An updated map is then generated and uploaded to the Internet using ArcIMS technology. The field investigator has the option to generate and view the Inspection Form at the end of his survey on site, or print a hardcopy at base. The mobile device also automatically generates preliminary editable Executive Reports for any inspected site.