915 resultados para Laser energy


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new formulation derived from thermal characters of inclusions and host films for estimating laser induced damage threshold has been deduced. This formulation is applicable for dielectric films when they are irradiated by laser beam with pulse width longer than tens picoseconds. This formulation can interpret the relationship between pulse-width and damage threshold energy density of laser pulse obtained experimentally. Using this formulation, we can analyze which kind of inclusion is the most harmful inclusion. Combining it with fractal distribution of inclusions, we have obtained an equation which describes relationship between number density of inclusions and damage probability. Using this equation, according to damage probability and corresponding laser energy density, we can evaluate the number density and distribution in size dimension of the most harmful inclusions. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The polarization dependence of the double resonant Raman scattering (2D) band in bilayer graphene (BLG) is studied as a function of the excitation laser energy. It has been known that the complex shape of the 2D band of BLG can be decomposed into four Lorentzian peaks with different Raman frequency shifts attributable to four individual scattering paths in the energy-momentum space. From our polarization dependence study, however, we reveal that each of the four different peaks is actually doubly degenerate in its scattering channels, i.e., two different scattering paths with similar Raman frequency shifts for each peak. We find theoretically that one of these two paths, ignored for a long time, has a small contribution to their scattering intensities but are critical in understanding their polarization dependences. Because of this, the maximum-to-minimum intensity ratios of the four peaks show a strong dependence on the excitation energy, unlike the case of single-layer graphene (SLG). Our findings thus reveal another interesting aspect of electron-phonon interactions in graphitic systems. © 2014 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A photoconductive semiconductor switch (PCSS) would work in a nonlinear mode under high biased electrical field. The experimental results of nonlinear critical state have shown that both the biased voltage and the laser energy may have working thresholds to turn on the nonlinear modes. The relation between the biased voltage (aid the laser energy is inverse ratio, i.e., higher biased field need lower laser energy for nonlinear mode, and vise versa. At the nonlinear critical point, the output of PCSS is unstable, as both the linear and nonlinear pulse may occur. As the laser energy and biased field increase, the PCSS would work in the nonlinear mode steadily. (C) 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 51: 56-59 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOT 10.1002/mop.24001

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper,active components of velvet antler polypeptide were extracted and separated.The molecular weight and purity of velvet antler polypeptide were determined by MALDI-TOFMS.The different influence factors such as matrix,sample concentration and laser energy were studied.This method is convenient and suitable for the identification of congener biochemical samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A detailed knowledge of the physical phenomena underlying the generation and the transport of fast electrons generated in high-intensity laser-matter interactions is of fundamental importance for the fast ignition scheme for inertial confinement fusion.

Here we report on an experiment carried out with the VULCAN Petawatt beam and aimed at investigating the role of collisional return currents in the dynamics of the fast electron beam. To that scope, in the experiment counter-propagating electron beams were generated by double-sided irradiation of layered target foils containing a Ti layer. The experimental results were obtained for different time delays between the two laser beams as well as for single-sided irradiation of the target foils. The main diagnostics consisted of two bent mica crystal spectrometers placed at either side of the target foil. High-resolution X-ray spectra of the Ti emission lines in the range from the Ly alpha to the K alpha line were recorded. In addition, 2D X-ray images with spectral resolution were obtained by means of a novel diagnostic technique, the energy-encoded pin-hole camera, based on the use of a pin-hole array equipped with a CCD detector working in single-photon regime. The spectroscopic measurements suggest a higher target temperature for well-aligned laser beams and a precise timing between the two beams. The experimental results are presented and compared to simulation results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe experiments designed to produce a bright M-L band x-ray source in the 3-3.5 keV region. Palladium targets irradiated with a 10(15) W cm(-2) laser pulse have previously been shown to convert up to similar to 2% of the laser energy into M-L band x-rays with similar pulse duration to that of the incident laser. This x-ray emission is further characterized here, including pulse duration and source size measurements, and a higher conversion efficiency than previously achieved is demonstrated (similar to 4%) using more energetic and longer duration laser pulses (200 ps). The emission near the aluminium K-edge (1.465-1.550 keV) is also reported for similar conditions, along with the successful suppression of such lower band x-rays using a CH coating on the rear side of the target. The possibility of using the source to radiatively heat a thin aluminium foil sample to uniform warm dense matter conditions is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Optical limiting and thermal lensing studies are carried out in C70–toluene solutions. The measurements are performed using 9-ns pulses generated from a frequencydoubled Nd:YAG laser at 532 nm. Optical limiting studies in fullerene molecules lead to the conclusion that reverse saturable absorption is the major mechanism for limiting. Analysis of thermal lensing measurements showed a quadratic dependence of thermal lens signal on incident laser energy, which also supports the view that optical limiting in C70 arises due to sequential two-photon absorption via excited triplet state (reverse saturable absorption).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Observation of laser induced two-photon photoemission optogalvanic (TPPOG) effect from tungsten electrode in a discharge cell using 564 nm radiation obtained from a pulsed dye laser is described. The magnitude of the POG signal is studied as a function of laser energy under various discharge parameters. Competition between one-photon and two-photon processes has been observed when nitrogen gas is used in the discharge cell.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concept of rationally designing MALDI matrices has been extended to the next “whole sample” level. These studies have revealed some unexpected and exploitable insights in improving MALDI sensitivity. It is shown that (i) additives which only provide additional laser energy absorption are best to be avoided; (ii) the addition of proton donors in the form of protonated weak bases can be highly beneficial; (iii) the addition of glycerol for coating crystalline samples is highly recommended. Overall, analytical sensitivity has been significantly increased compared to the current “gold” standards in MALDI MS, and new insights into the mechanisms and processes of MALDI have been gained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reports on the use of radially polarised beam in gold-nanorod-facilitated nonlinear microscopy and therapy. It has been found that the use of radially polarised beam can greatly reduce the energy fluence threshold for treating cancer cells labelled with gold nanorods. The slight distortion in the polarisation properties of the radially polarised beam after propagating through double-clad photonic crystal fibres makes it promising in the application of fibre-optic based endoscopic system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE Thermal Nd:YAG laser energy is well known for the purpose of blood coagulation. However, little is known about the bleeding frequency following laser-assisted oral surgery in patients on coumarin drugs. Therefore, the purpose of this study was to compare retrospectively the frequency of bleeding complications following Nd:YAG laserassisted versus conventional local coagulation of blood in oral surgery. METHOD AND MATERIALS In October 2002, minor oral surgical interventions were found to be indicated in a total of 45 cardiac risk patients. In Group 1, blood coagulation was yielded in 24 patients with a Nd:YAG laser system, whereas in Group 2, treatment was performed in 21 patients with conventional means of local hemostasis. All therapies were performed continuing anticoagulant therapy between November 2002 and March 2003. Clinical data were recorded retrospectively from patient charts in May 2007. RESULTS In both Groups 1 and 2, a total of two bleeding complications were recorded. However, local re-interventions were sufficient for local hemostasis. CONCLUSION These results indicate that Nd:YAG laser-assisted local hemostasis was not able to prevent bleeding complications completely. Within the limitations of this retrospective study it was concluded that in patients with anticoagulant treatment undergoing minor oral surgery, Nd:YAG laser-assisted local hemostasis is not superior to conventional methods of blood coagulation with respect to the frequency of bleeding complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

HiPER is the European Project for Laser Fusion that has been able to join 26 institutions and signed under formal government agreement by 6 countries inside the ESFRI Program of the European Union (EU). The project is already extended by EU for two years more (until 2013) after its first preparatory phase from 2008. A large work has been developed in different areas to arrive to a design of repetitive operation of Laser Fusion Reactor, and decisions are envisioned in the next phase of Technology Development or Risk Reduction for Engineering or Power Plant facilities (or both). Chamber design has been very much completed for Engineering phase and starting of preliminary options for Reactor Power Plant have been established and review here.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of inertial confinement fusion is the production of energy by the fusion of thermonuclear fuel (deuterium-tritium) enclosed in a spherical target due to its implosion. In the direct-drive approach, the energy needed to spark fusion reactions is delivered by the irradiation of laser beams that leads to the ablation of the outer shell of the target (the so-called ablator). As a reaction to this ablation process, the target is accelerated inwards, and, provided that this implosion is sufficiently strong a symmetric, the requirements of temperature and pressure in the center of the target are achieved leading to the ignition of the target (fusion). One of the obstacles capable to prevent appropriate target implosions takes place in the ablation region where any perturbation can grow even causing the ablator shell break, due to the ablative Rayleigh-Taylor instability. The ablative Rayleigh-Taylor instability has been extensively studied throughout the last 40 years in the case where the density/temperature profiles in the ablation region present a single front (the ablation front). Single ablation fronts appear when the ablator material has a low atomic number (deuterium/tritium ice, plastic). In this case, the main mechanism of energy transport from the laser energy absorption region (low density plasma) to the ablation region is the electron thermal conduction. However, recently, the use of materials with a moderate atomic number (silica, doped plastic) as ablators, with the aim of reducing the target pre-heating caused by suprathermal electrons generated by the laser-plasma interaction, has demonstrated an ablation region composed of two ablation fronts. This fact appears due to increasing importance of radiative effects in the energy transport. The linear theory describing the Rayleigh-Taylor instability for single ablation fronts cannot be applied for the stability analysis of double ablation front structures. Therefore, the aim of this thesis is to develop, for the first time, a linear stability theory for this type of hydrodynamic structures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivos : Analizar la distribución de energía en un tejido cuando se emplea terapia por láser de baja potencia y estudiar las especificaciones mínimas de equipos de terapia láser para estimar la dosis. Material y métodos: Se ha empleado el método de Monte Carlo para obtener la distribución de energía absorbida por la piel para dos tipos de láser y la teoría de la difusión para estimar la longitud de penetración y el recorrido libre medio. Se ha estudiado la variación de esa distribución en función de la raza (caucásico, asiático, afroamericano) y para dos localizaciones anatómicas distintas. Se ha analizado la información facilitada por diversos fabricantes de equipos comerciales para determinar si es necesario adaptar la dosimetría recomendada. Resultados: La radiación láser infrarroja (810nm) se absorbe mayoritariamente en un espesor de piel de 1,9±0,2mm para caucásicos, entre 1,73±0,08mm (volar del antebrazo) y 1,80±0,11mm (palma) para asiáticos y entre 1,25±0,09mm (volar del antebrazo) y 1,65±0,2mm (palma) para afroamericanos. El recorrido libre medio de la luz siempre es menor que 0,69±0,09mm. Para los equipos comerciales analizados la única característica geométrica del haz láser que se menciona es la superficie que oscila entre 0,08 y 1cm2, pero no se especifica cómo es la distribución de energía, la divergencia del haz, forma de la sección transversal, etc. Conclusiones:Dependiendo del equipo de terapia por láser de baja potencia utilizado, el tipo de paciente y la zona a tratar, el clínico debe adaptar las dosis recomendadas. Abstract: Objectives: To analyze the distribution of energy deposited in a tissue when this is irradiated with a low power laser and to study the minimum characteristics that manufacturers of low power laser therapy equipments should include to estimate the dosage. Material and methods: Monte Carlo simulation was performed to determine the absorption location of the laser energy. The diffusion theory was used to estimate penetration depth and mean free path. Variation of this distribution was studied based on three different skin types (Caucasians, Asians and Afroamericans) and for two different anatomic locations: palm and volar forearm. Information given by several manufactures of low power laser therapy equipments has been analyzed. Results: Infrared (810 nm) laser radiation is mainly absorbed in a skin layer of thickness 1.9±0.2mm for Caucasians, from 1.73±0.08mm (volar forearm) to 1.80±0.11mm (palm) for Asians, and from 1.25±0.09mm (volar forearm) to 1.65±0.2mm (palm) for Afroamericans. The light mean free path is lower than 0.69±0.09mm for all cases. The laser beam characteristics (beam shape, energy distribution on a transversal section, divergence, incidence angle,etc.) are not usually specified by the manufacturers. Only beam size (ranging from 0.08 to 1cm2) is given in some cases. Discussion and conclusions: Depending on the low power laser therapy equipment, on the patient and on the anatomic area to be treated, the staff should adapt the recommended dosage for each individual case.