988 resultados para Laboratory wall samples


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Science of the total environment 405(2008) 278-285

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Here in is described the clinical and laboratorial findings of a laboratory-acquired infection caused by the virus SP H 114202 (Arenavirus, family Arenaviridae) a recently discovered agent responsible for a viral hemorrhagic fever. The patient was sick for 13 days. The disease had an abrupt onset characterized by high fever (39ºC.), headache, chills and myalgias for 8 days. In addition, on the 3rd day, the patient developed nauseas and vomiting, and in the 10th, epigastralgia, diarrheia and gengivorrhagia. Leucopenia was seen within the 1 st week of onset, with counts as low as 2,500 white cells per mm³. Counts performed after the 23th day of the onset were within normal limits. With the exception of moderate lymphocitosis, no changes were observed in differential counts. An increase in the liter of antibodies by complement fixation, neutralization and ELISA (IgM) was detected. Suckling mice and baby hamsters were inoculated intracerebrally with 0.02 ml of blood samples collected in the 2nd and 7th days of disease. Attempts to isolate the virus were also made in Vero cells. No virus was isolated. This virus was isolated before in a single occasion in São Paulo State, in 1990, from the blood of a patient with hemorrhagic fever with a fatal outcome. The manipulation of the virus under study, must be done carefully, since the transmission can occur through aerosols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human infection by Cryptosporidium spp and other coccidia are due to opportunist non-host specific microorganisms. In HIV seropositive patients, the gastrointestinal symptoms accompanying such infections may be serious and prolonged and may include nausea, low-grade fever, abdominal cramps, anorexia and watery diarrhoea. We studied 188 stool samples from 111 patients (84 men and 27 women) with diarrhoea. A modified Ziehl-Nielsen technique for the detection of Cryptosporidium spp and Isospora belli was employed. The mean age of the patients was 31 years. Cryptosporidium spp was seen in 18% (n=20) of the patients, 90% (n=18) of whom were HIV seropositive. Isospora belli was recorded only from HIV seropositive patients (5.4% of all the patients studied and 6.5% of those who were HIV seropositive). These data confirm the good results obtained with this technique for the identification of Cryptosporidium spp and other coccidia and also reaffirm the clinical importance of correctly diagnosing the cause of diarrhoea, particularly in HIV seropositive patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Animal and human rabies samples isolated between 1989 and 2000 were typified by means of a monoclonal antibody panel against the viral nucleoprotein. The panel had been previously established to study the molecular epidemiology of rabies virus in the Americas. Samples were isolated in the Diagnostic Laboratory of the Pasteur Institute and in other rabies diagnostic centers in Brazil. In addition to the fixed virus samples CVS-31/96-IP, preserved in mouse brain, and PV-BHK/97, preserved in cell culture, a total of 330 rabies virus samples were isolated from dogs, cats, cattle, horses, bats, sheep, goat, swine, foxes, marmosets, coati and humans. Six antigenic variants that were compatible with the pre-established monoclonal antibodies panel were defined: numbers 2 (dog), 3 (Desmodus rotundus), 4 (Tadarida brasiliensis), 5 (vampire bat from Venezuela), 6 (Lasiurus cinereus) and Lab (reacted to all used antibodies). Six unknown profiles, not compatible with the panel, were also found. Samples isolated from insectivore bats showed the greatest variability and the most commonly isolated variant was variant-3 (Desmodus rotundus). These findings may be related to the existence of multiple independent transmission cycles, involving different bat species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Selenium modified ruthenium electrocatalysts supported on carbon black were synthesized using NaBH4 reduction of the metal precursor. Prepared Ru/C electrocatalysts showed high dispersion and very small averaged particle size. These Ru/C electrocatalysts were subsequently modified with Se following two procedures: (a) preformed Ru/carbon catalyst was mixed with SeO2 in xylene and reduced in H2 and (b) Ru metal precursor was mixed with SeO2 followed by reduction with NaBH4. The XRD patterns indicate that a pyrite-type structure was obtained at higher annealing temperatures, regardless of the Ru:Se molar ratio used in the preparation step. A pyrite-type structure also emerged in samples that were not calcined; however, in this case, the pyrite-type structure was only prominent for samples with higher Ru:Se ratios. The characterization of the RuSe/C electrocatalysts suggested that the Se in noncalcined samples was present mainly as an amorphous skin. Preliminary study of activity toward oxygen reduction reaction (ORR) using electrocatalysts with a Ru:Se ratio of 1:0.7 indicated that annealing after modification with Se had a detrimental effect on their activity. This result could be related to the increased particle size of crystalline RuSe2 in heat-treated samples. Higher activity of not annealed RuSe/C catalysts could also be a result of the structure containing amorphous Se skin on the Ru crystal. The electrode obtained using not calcined RuSe showed a very promising performance with a slightly lower activity and higher overpotential in comparison with a commercial Pt/C electrode. Single wall carbon nanohorns (SWNH) were considered for application as ORR electrocatalysts' supports. The characterization of SWNH was carried out regarding their tolerance toward strong catalyzed corrosion conditions. Tests indicated that SWNH have a three times higher electrochemical surface area (ESA) loss than carbon black or Pt commercial electrodes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty-four whole blood and serum samples were drawn from an eight year-old heart transplant child during a 36 months follow-up. EBV serology was positive for VCA-IgM and IgG, and negative for EBNA-IgG at the age of five years old when the child presented with signs and symptoms suggestive of acute infectious mononucleosis. After 14 months, serological parameters were: positive VCA-IgG, EBNA-IgG and negative VCA-IgM. This serological pattern has been maintained since then even during episodes suggestive of EBV reactivation. PCR amplified a specific DNA fragment from the EBV gp220 (detection limit of 100 viral copies). All twenty-four whole blood samples yielded positive results by PCR, while 12 out of 24 serum samples were positive. We aimed at analyzing whether detection of EBV-DNA in serum samples by PCR was associated with overt disease as stated by the need of antiviral treatment and hospitalization. Statistical analysis showed agreement between the two parameters evidenced by the Kappa test (value 0.750; p < 0.001). We concluded that detection of EBV-DNA in serum samples of immunosuppressed patients might be used as a laboratory marker of active EBV disease when a Real-Time PCR or another quantitative method is not available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB). Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51). The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5%) and 47-52 kDa (80%). The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001). In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study is to evaluate cyst wall and protoscolex as an alternate source of antigen in serodiagnosis of cystic echinococcosis (CE). A total of 90 blood samples, 30 each of confirmed CE cases, disease controls and healthy controls were collected. Dot-ELISA using cyst wall, protoscolex and cyst fluid were used to demonstrate anti-hydatid antibodies. The sensitivity of Dot-ELISA using cyst wall, protoscolex and cyst fluid was 96.66%, 86.66% and 93.33% respectively and the specificity of the assay was 70% for Dot-ELISA using cyst fluid, protoscolex and cyst wall antigens. Results of the present study show that cyst wall and protoscolex can also be an useful source of antigen in detection of hydatid antibodies in the serodiagnosis of CE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bacteria of the genus Bartonella are emerging pathogens detected in lymph node biopsies and aspirates probably caused by increased concentration of bacteria. Twenty-three samples of 18 patients with clinical, laboratory and/or epidemiological data suggesting bartonellosis were subjected to three nested amplifications targeting a fragment of the 60-kDa heat shock protein (HSP), the internal transcribed spacer 16S-23S rRNA (ITS) and the cell division (FtsZ) of Bartonella henselae, in order to improve detection in clinical samples. In the first amplification 01, 04 and 05 samples, were positive by HSP (4.3%), FtsZ (17.4%) and ITS (21.7%), respectively. After the second round six positive samples were identified by nested-HSP (26%), eight by nested-ITS (34.8%) and 18 by nested-FtsZ (78.2%), corresponding to 10 peripheral blood samples, five lymph node biopsies, two skin biopsies and one lymph node aspirate. The nested-FtsZ was more sensitive than nested-HSP and nested-ITS (p < 0.0001), enabling the detection of Bartonella henselae DNA in 15 of 18 patients (83.3%). In this study, three nested-PCR that should be specific for Bartonella henselae amplification were developed, but only the nested-FtsZ did not amplify DNA from Bartonella quintana. We conclude that nested amplifications increased detection of B. henselae DNA, and that the nested-FtsZ was the most sensitive and the only specific to B. henselae in different biological samples. As all samples detected by nested-HSP and nested-ITS, were also by nested-FtsZ, we infer that in our series infections were caused by Bartonella henselae. The high number of positive blood samples draws attention to the use of this biological material in the investigation of bartonellosis, regardless of the immune status of patients. This fact is important in the case of critically ill patients and young children to avoid more invasive procedures such as lymph nodes biopsies and aspirates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CIAV2013 – International Conference on Vernacular Architecture, 7º ATP, VerSus, 16-20 october 2013

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work demonstrates that deltamethrin in low doses produces an excito-repellency effect on triatomines, as already observed for mosquitoes. A wooden box covered with a cloth impregnated with deltamethrin at doses of 2.5 and 5mg ai/m² was utilized for the experiment. The triatomine species studied were Triatoma infestans, Panstrongylus megistus, Rhodnius neglectus and Triatoma sordida. Adults were released in one of the sides of the box and their position was noted in subsequent periods. The observations were realized on the day the cloth was impregnated and subsequently repeated at 30 and 60 days for T. sordida; on day 120, the remaining species were included. Insect mortality and attempts at flight from the box were also observed. Excito-repellency was evident for all species and doses up to day 120. The only species that attempted to fly was P. megistus. The excito-repellency effect may be considered as an additional advantage to the insecticide power, as it should be able to prevent the installation of new colonies by females that fly into the homes, and at the moment of the spraying, it should promote the flushing out of triatomines from the wall crevices and from other shelters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Were analyzed 648 serum samples from laboratory staff in Goiânia, Goiás aiming detection of three serological markers of HBV: HBsAg, anti-HBsAg and anti-HBcAg. The HBsAg and anti-HBcAg positive samples were also analyzed for HBeAg, anti-HBeAg and anti-HBcAgIgM markers. HBV infection rate of 24.1% was observed and, from them, 0.7% were positive for HBsAg. Viral DNA was detected by PCR in two HBsAg positive samples. A vaccination index of 74.5% and a global index of 89.9% of serological response to vaccination were observed. The direct work with biological fluids as well as cleaning workers represented significant risks for acquisition of HBV infection. The data from the present study showed an increase of the vaccination index among laboratory staff but the rates of HBV infection did not change through the years in the region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis for American cutaneous leishmaniasis is based on an association of clinical, epidemiological and laboratory characteristics. The present study identified the circulating species of Leishmania in the State of Pernambuco, described its clinical-epidemiological characteristics and diagnosed the disease. Nineteen patients presenting active lesions who had been diagnosed through clinical evaluation and laboratory tests were selected. The tests included direct investigation, in vitro culturing, Montenegro skin test, indirect immunofluorescence and polymerase chain reaction. The Montenegro Skin Test showed positive results in 89% of the patients; indirect immunofluorescence, in 79%; direct investigation, in 58%; and polymerase chain reaction in 75%. Seven Leishmania (Viannia) braziliensis samples were isolated from these patients and were characterized by means of specific monoclonal antibodies. These data confirm that a combination of different diagnosis techniques is needed in order to obtain efficient results and that, so far, Leishmania (Viannia) braziliensis is the only species responsible for American cutaneous leishmaniasis infection in Pernambuco. Thus, it is essential to identify the parasite species involved in cases of human disease in an endemic area in order to determine the clinical and epidemiological characteristics, especially with regard to diagnosis, therapy development and disease prognosis.