945 resultados para LEG COORDINATION
Resumo:
There is an increasing desire and emphasis to integrate assessment tools into the everyday training environment of athletes. These tools are intended to fine-tune athlete development, enhance performance and aid in the development of individualised programmes for athletes. The areas of workload monitoring, skill development and injury assessment are expected to benefit from such tools. This paper describes the development of an instrumented leg press and its application to testing leg dominance with a cohort of athletes. The developed instrumented leg press is a 45° reclining sled-type leg press with dual force plates, a displacement sensor and a CCD camera. A custom software client was developed using C#. The software client enabled near-real-time display of forces beneath each limb together with displacement of the quad track roller system and video feedback of the exercise. In recording mode, the collection of athlete particulars is prompted at the start of the exercise, and pre-set thresholds are used subsequently to separate the data into epochs from each exercise repetition. The leg press was evaluated in a controlled study of a cohort of physically active adults who performed a series of leg press exercises. The leg press exercises were undertaken at a set cadence with nominal applied loads of 50%, 100% and 150% of body weight without feedback. A significant asymmetry in loading of the limbs was observed in healthy adults during both the eccentric and concentric phases of the leg press exercise (P < .05). Mean forces were significantly higher beneath the non-dominant limb (4–10%) and during the concentric phase of the muscle action (5%). Given that symmetrical loading is often emphasized during strength training and remains a common goal in sports rehabilitation, these findings highlight the clinical potential for this instrumented leg press system to monitor symmetry in lower-limb loading during progressive strength training and sports rehabilitation protocols.
Resumo:
Background: Exercise and adequate self-management capacity may be important strategies in the management of venous leg ulcers. However, it remains unclear if exercise improves the healing rates of venous leg ulcers and if a self-management exercise program based on self-efficacy theory is well adhered to. Method/Design: This is a randomised controlled in adults with venous leg ulcers to determine the effectiveness of a self-efficacy based exercise intervention. Participants with venous leg ulcers are recruited from 3 clinical sites in Australia. After collection of baseline data, participants are randomised to either an intervention group or control group. The control group receive usual care, as recommended by evidence based guidelines. The intervention group receive an individualised program of calf muscle exercises and walking. The twelve week exercise program integrates multiple elements, including up to six telephone delivered behavioural coaching and goal setting sessions, supported by written materials, a pedometer and two follow-up booster calls if required. Participants are encouraged to seek social support among their friends, self-monitor their weekly steps and lower limb exercises. The control group are supported by a generic information sheet that the intervention group also receive encouraging lower limb exercises, a pedometer for self-management and phone calls at the same time points as the intervention group. The primary outcome is the healing rates of venous leg ulcers which are assessed at fortnightly clinic appointments. Secondary outcomes, assessed at baseline and 12 weeks: functional ability (range of ankle motion and Tinetti gait and balance score), quality of life and self-management scores. Discussion: This study seeks to address a significant gap in current wound management practice by providing evidence for the effectiveness of a home-based exercise program for adults with venous leg ulcers. Theory-driven, evidence-based strategies that can improve an individual’s exercise self-efficacy and self-management capacity could have a significant impact in improving the management of people with venous leg ulcers. Information gained from this study will provide much needed information on management of this chronic disease to promote health and independence in this population. Trial registration: Australian New Zealand Clinical Trials Registry ACTRN12612000475842 Trial status: Current follow up
Resumo:
Premise of the study: Plant invasiveness can be promoted by higher values of adaptive traits (e.g., photosynthetic capacity, biomass accumulation), greater plasticity and coordination of these traits, and by higher and positive relative influence of these functionalities on fitness, such as increasing reproductive output. However, the dataset for this premise rarely include linkages between epidermal-stomatal traits, leaf internal anatomy, and physiological performance. Methods: Three ecological pairs of invasive vs non-invasive (native) woody vine species of South-East Queensland, Australia were investigated for trait differences in leaf morphology and anatomy under varying light intensity. The linkages of these traits with physiological performance (e.g. water use efficiency, photosynthesis, and leaf construction cost) and plant adaptive traits of specific leaf area, biomass, and relative growth rates were also explored. Key results: Mean leaf anatomical trait differed significantly between the two groups, except for stomatal size. Plasticity of traits, and to a very limited extent, their phenotypic integration were higher in the invasive relative to the native species. ANOVA, ordination, and analysis of similarity suggest that for leaf morphology and anatomy, the three functional strategies contribute to the differences between the two groups in the order phenotypic plasticity > trait means > phenotypic integration. Conclusions: The linkages demonstrated in the study between stomatal complex/gross anatomy and physiology are scarce in the ecological literature of plant invasiveness, but the findings suggest that leaf anatomical traits need to be considered routinely as part of weed species assessment and in the worldwide leaf economic spectrum.
Resumo:
This project developed, validated and tested reliability of a risk assessment tool to predict the risk of failure to heal of patients with venous leg ulcers within 24 weeks. The risk assessment tool will allow clinicians to be able to determine realistic outcomes for their patients, promote early healing and potentially avoid weeks of inappropriate therapy. The tool will also assist in addressing specific risk factors and guide decisions on early, alternative, tailored interventions.
Resumo:
Leg Clubs are an innovative approach to the holistic treatment of leg ulcers. They are run in a social context by community nurses who deliver ongoing support and treatment for a wide spectrum of lower limb pathology. This article looks at how the Leg Club model has been established in Australia.
Resumo:
The prevalence of leg ulcers of is 0.12%–1.1% and >3,000 lower limb amputations are performed yearly in Australia due to non-healing leg or foot ulcers. Although evidence on leg ulcer management is available, a significant evidence-practice gap exists. To identify current leg ulcer management, a cross-sectional retrospective study was undertaken in Brisbane, Australia. A sample of 104 clients was recruited from a community specialist wound clinic and a tertiary hospital outpatient’s specialist wound clinic. All clients had an ulcer below their knee or on their foot for ≥4 weeks. Data were collected on ulcer care, health service usage and clinical history for the year prior to admission. On admission, participants reported having their ulcer for a median of 25 weeks (range 2-728 weeks); with 51% (53/104) reporting an ulcer duration of ≥24 weeks. Including the wound clinic, participants sought ulcer care from a median of 3 health care providers (range 2-7). General Practitioners provided ulcer care to 82% of participants. Nearly half (42%) had self-cared for their ulcer; 29% (30/104) received treatment by a community nurse. A gap was found between the community-based ulcer care experienced by this population and evidence-based guidelines in regards to assessment, management, advice, and referrals.
Resumo:
Nowadays, integration of small-scale electricity generators, known as Distributed Generation (DG), into distribution networks has become increasingly popular. This tendency together with the falling price of DG units has a great potential in giving the DG a better chance to participate in voltage regulation process, in parallel with other regulating devices already available in the distribution systems. The voltage control issue turns out to be a very challenging problem for distribution engineers, since existing control coordination schemes need to be reconsidered to take into account the DG operation. In this paper, a control coordination approach is proposed, which is able to utilize the ability of the DG as a voltage regulator, and at the same time minimize the interaction of DG with another DG or other active devices, such as On-load Tap Changing Transformer (OLTC). The proposed technique has been developed based on the concepts of protection principles (magnitude grading and time grading) for response coordination of DG and other regulating devices and uses Advanced Line Drop Compensators (ALDCs) for implementation. A distribution feeder with tap changing transformer and DG units has been extracted from a practical system to test the proposed control technique. The results show that the proposed method provides an effective solution for coordination of DG with another DG or voltage regulating devices and the integration of protection principles has considerably reduced the control interaction to achieve the desired voltage correction.
Resumo:
The heavy haul rail network in Queensland Australia generally adopts a lightning impulse withstand voltage rating of 250 kV for the switchgear and autotransformers within its 50 kV ac traction feeder stations. The aging switchgear across a number of feeder stations in this network are undergoing upgrade and the rail network operator is considering the possibility of using 200 kV rating for the upgraded switchgear. This paper investigates the lightning over-voltages that could occur at the feeder stations under review. Fast front transient models of the feeder stations and the associated traction corridors are developed in PSCAD/EMTDC software. Simulations are conducted to evaluate the likely over-voltages under various scenarios and the results are presented. Finally, the required lightning impulse withstand voltage rating for the switchgear is determined based on the simulation results.
Resumo:
Background Chronic leg ulcers, remaining unhealed after 4–6 weeks, affect 1-3% of the population, with treatment costly and health service resource intensive. Venous disease contributes to approximately 70% of all chronic leg ulcers and these ulcers are often associated with pain, reduced mobility and a decreased quality of life. Despite evidence-based care, 30% of these ulcers are unlikely to heal within a 24-week period and therefore the recognition and identification of risk factors for delayed healing of venous leg ulcers would be beneficial. Aim To review the available evidence on risk factors for delayed healing of venous leg ulcers. Methods: A review of the literature in regard to risk factors for delayed healing in venous leg ulcers was conducted from January 2000 to December 2013. Evidence was sourced through searches of relevant databases and websites for resources addressing risk factors for delayed healing in venous leg ulcers specifically. Results Twenty-seven studies, of mostly low-level evidence (Level III and IV), identified risk factors associated with delayed healing. Risk factors that were consistently identified included: larger ulcer area, longer ulcer duration, a previous history of ulceration, venous abnormalities and lack of high compression. Additional potential predictors with inconsistent or varying evidence to support their influence on delayed healing of venous leg ulcers included decreased mobility and/or ankle range of movement, poor nutrition and increased age. Discussion Findings from this review indicate that a number of physiological risk factors are asso- ciated with delayed healing in venous leg ulcers and that social and/or psychological risk factors should also be considered and examined further. Conclusion The findings from this review can assist health professionals to identify prognostic indicators or risk factors significantly associated with delayed healing in venous leg ulcers. This will facilitate realistic outcome planning and inform implementation of appropriate early strategies to promote healing.
Resumo:
Background The high recurrence rate of chronic venous leg ulcers has a significant impact on an individual’s quality of life and healthcare costs. Objectives This study aimed to identify risk and protective factors for recurrence of venous leg ulcers using a theoretical approach by applying a framework of self and family management of chronic conditions to underpin the study. Design Secondary analysis of combined data collected from three previous prospective longitudinal studies. Setting The contributing studies’ participants were recruited from two metropolitan hospital outpatient wound clinics and three community-based wound clinics. Participants Data were available on a sample of 250 adults, with a leg ulcer of primarily venous aetiology, who were followed after ulcer healing for a median follow-up time of 17 months after healing (range: 3 to 36 months). Methods Data from the three studies were combined. The original participant data were collected through medical records and self-reported questionnaires upon healing and every 3 months thereafter. A Cox proportion-hazards regression analysis was undertaken to determine the influential factors on leg ulcer recurrence based on the proposed conceptual framework. Results The median time to recurrence was 42 weeks (95% CI 31.9–52.0), with an incidence of 22% (54 of 250 participants) recurrence within three months of healing, 39% (91 of 235 participants) for those who were followed for six months, 57% (111 of 193) by 12 months, 73% (53 of 72) by two years and 78% (41 of 52) of those who were followed up for three years. A Cox proportional-hazards regression model revealed that the risk factors for recurrence included a history of deep vein thrombosis (HR 1.7, 95% CI 1.07–2.67, p=0.024), history of multiple previous leg ulcers (HR 4.4, 95% CI 1.84–10.5, p=0.001), and longer duration (in weeks) of previous ulcer (HR 1.01, 95% CI 1.003–1.01, p<0.001); while the protective factors were elevating legs for at least 30 minutes per day (HR 0.33, 95% CI 0.19–0.56, p<0.001), higher levels of self-efficacy (HR 0.95, 95% CI 0.92–0.99, p=0.016), and walking around for at least three hours/day (HR 0.66, 95% CI 0.44–0.98, p=0.040). Conclusions Results from this study provide a comprehensive examination of risk and protective factors associated with leg ulcer recurrence based on the chronic disease self and family management framework. These results in turn provide essential steps towards developing and testing interventions to promote optimal prevention strategies for venous leg ulcer recurrence.
Resumo:
Integration of small-scale electricity generators, known as distributed generation (DG), into the distribution networks has become increasingly popular at the present. This tendency together with the falling price of the synchronous-type generator has potential to give DG a better chance at participating in the voltage regulation process together with other devices already available in the system. The voltage control issue turns out to be a very challenging problem for the distribution engineers since existing control coordination schemes would need to be reconsidered to take into account the DG operation. In this paper, we propose a control coordination technique, which is able to utilize the ability of DG as a voltage regulator and, at the same time, minimize interaction with other active devices, such as an on-load tap changing transformer and a voltage regulator. The technique has been developed based on the concept of control zone, line drop compensation, dead band, as well as the choice of controllers' parameters. Simulations carried out on an Australian system show that the technique is suitable and flexible for any system with multiple regulating devices including DG.
Resumo:
The objective of this study was to identify symptom clusters and their effect on quality of life (QOL) of adults with chronic leg ulcers of mixed venous and arterial aetiology. A secondary analysis of data from four existing prospective longitudinal studies conducted by a wound healing research group in Australia was undertaken. A total of 110 patients who met the inclusion criteria were selected for this study. Exploratory factor analysis (EFA) was used to identify symptom clusters and correlational analyses to examine relationships between the identified symptom clusters and QOL. The EFA identified two distinct symptom clusters: a 'systemic symptom cluster' consisting of pain, fatigue and depressive symptoms; and a 'localised-leg symptom cluster' including pain, fatigue, oedema, lower limb inflammation and exudate. Physical QOL correlated significantly with the systemic symptom cluster (r = -0·055, P < 0·0001) and the localised-leg symptom cluster (r = -0·054, P < 0·0001), whereas mental QOL was associated only with the systemic symptom cluster (r = -0·038, P = 0·01). The results suggest that appropriate intervention strategies targeting specific symptom clusters should be developed. Targeting patients with symptom clusters is particularly important because they are at high risk and the most vulnerable for reduced QOL.
Resumo:
The delivery of cancer services has become increasingly complex as we move to more personalized diagnostic and treatment approaches and cancer is recognized as a chronic disease. Cancer patients today typically come into contact with multiple health services over long periods. Healthcare reforms in many countries also mean that the various services involved in cancer care are funded by a confusing mix of personal, private insurer, and government sources. It is not surprising then that many patients today tell us their cancer experience is disjointed. Importantly, this lack of coordination of cancer care results in poor outcomes that can range from minor inconvenience at best to potentially life-threatening safety incidents at worst.
Resumo:
Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.