97 resultados para JPS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nephrolepis exaltata L. Schott "Bostoniensis" family Davalliaceae and Equisetum giganteum L. family Equisetaceae, Phylum Pteridophyta, exhibit a strong mechanism of dominance in the areas in which they live. Have secondary compounds with allelopathic activity. The objective of this article was evaluate allelopathic potential of two ferns species, using bioassay applying aqueous extracts of dried fronds, in cucumber and lettuce seeds, and observing germination and initial development. To observe the influence on germination was analyze the percentage of germinated seeds and germination speed index (GSI). To observe initial development was analyzed shoot and root growth of the seedlings. The bioassays revealed that no concentration significantly inhibited the germination, but germination speed was delayed gradually in two species tested, as increased the extract concentration. In initial development, all the extracts showed a tendency to inhibit the growth, and an increase in extract concentration decreasing growth of radicle and hypocotyl axis. We conclude that the aqueous extract has inhibitory activity more pronounced in early development than in seed germination, affecting the primary structures of the tested plants, corroborating with the observations of occurrences of the species in natural places where dominate and suppress the growth of other species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is the first report on the parasitoid Palmistichus elaeisis, genus Eulophidae, found in the field parasitizing pupae of defoliating eucalyptus. Lepidopterous pests occur in eucalyptus plantations in Brazil, reaching high population levels. Due to the complexity of pest control in eucalyptus forests, alternative control methods have been proposed, for instance biological control through use of parasitoids. Natural enemies play an important role in regulating host populations because their larvae feed on the eggs, larvae, pupae or adults of other insects. The parasitic Hymenoptera are important agents in biological control programs against forest pests, and may provide economic and environmental benefits. The generalist endoparasitoid Palmistichus elaeisis Delvare and LaSalle, 1993 (Hymenoptera: Eulophidae) can develop in its host’s pupae, which overcome the host’s physiology and can therefore be used for biological control of agricultural and forest pests. This study aimed to evaluate the impact of P. elaeisis as a pupal parasitoid of S. violascens in providing a potential alternative to chemical control of the pest and creation of an alternative host. The experiment was developed in the Laboratory for Biological Control of Forest Pests, Universidade Estadual Paulista "Julio Mesquita Filho”. Parasitoids used in this test were originally collected on pupae of E. eucerus. (Lepidoptera: Riodinidae) in eucalyptus plantations at Lençois Paulistas, São Paulo state, Brazil, in 2011. Thereafter, a laboratory culture has been maintained, using pupae of Spodoptera frugiperda (J. E. Smith) (Lep.: Noctuidae) as hosts. S. violascens eggs were collected in a eucalyptus clonal plantation in Sao Paulo state (Brazil). Larvae were reared under ambient conditions on Eucalyptus urophylla S.T. Blake (Myrtaceae) leaves. The following parameters were determined: parasitism level, numbers of emerged and non-emerged parasitoids and duration of egg-adult cycle. The S. violascens pupae were dissected to evaluate the non-emerged parasitoids. The parasitism level reached 100%, with a 100% emergence rate. It was verified that 113.2±0.8 parasitoids emerged per individual pupa versus only 0.7±0.1 that did not emerge. The P. elaeisis egg-adult cycle was 20.3±0.6 days in S. violascens pupae. This opens new perspectives for utilizing this parasitoid in biological control programs against caterpillars important to forestry. Sarsina violascens in Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To optimize solubility of drugs, current strategies mainly focus on engineering and screening of smart crystal phases. Two salts of the anti-human immunodeficiency virus (HIV) drug lamivudinenamely, lamivudine hydrochloride and lamivudine hydrochloride monohydrate, were prepared in the course of screening the crystallization conditions of lamivudine duplex, an uncommon DNA-mimic, double-stranded helical structure made up of partially protonated drug pairs. Here, water solubilities of lamivudine hydrochloride, lamivudine hydrochloride monohydrate, and lamivudine duplex are reported. The aqueous solubility of this anti-HIV drug was significantly increased in both salts and also in lamivudine duplex in relation to the water solubility of lamivudine form II. In comparison with the lamivudine form II incorporated into therapeutic formulations, the drug solubility was increased at a temperature of 299 +/- 2 K by factors of 1.2, 3.3, and 4.5 in lamivudine hydrochloride, lamivudine hydrochloride monohydrate, and lamivudine duplex, respectively, demonstrating that this solid-state property of lamivudine can be improved by crystal engineering strategies. Solubility profiles were understood on the basis of structural and solventsolute interaction approaches. At last, correlations between solubility and crystal structures allowed for a rational approach to understand how this physicochemical feature could be enhanced by engineering new salts of the drug. (C) 2012 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 101:21432154, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new concept for in vitro visual evaluation of sun protection factor (SPF) of cosmetic formulations based on a supramolecular ultraviolet (UV) dosimeter was clearly demonstrated. The method closely parallels the method validated for in vivo evaluation and relies on the determination of the slightest perceptible bleaching of an iron-complex dye/nanocrystallinetitanium dioxide interface (UV dosimeter) in combination with an artificial skin substrate simulating the actual human skin in the presence and absence of a cosmetic formulation. The successful evaluation of SPF was ensured by the similarity of the erythema response of our dosimeter and human skin to UV light irradiation. A good linear correlation of in vitro and in vivo data up to SPF 40 confirmed the effectiveness of such a simple, cheap, and fast method. In short, here we unravel a convenient and accessible visual FPS evaluation method that can help improving the control on cosmetic products contributing to the reduction of skin cancer, one of the critical public health issues nowadays. (C) 2011 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 101:726732, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Literature data relevant to the decision to allow a waiver of in vivo bioequivalence (BE) testing for the approval of immediate-release (IR) solid oral dosage forms containing stavudine (d4T) are reviewed. According to Biopharmaceutics Classification System (BCS), d4T can be assigned to BCS class I. No problems with BE of IR d4T formulations containing different excipients and produced by different manufacturing methods have been reported and, hence, the risk of bioinequivalence caused by these factors appears to be low. Furthermore, d4T has a wide therapeutic index. It is concluded that a biowaiver is appropriate for IR solid oral dosage forms containing d4T as the single active pharmaceutical ingredient (API) provided that (a) the test product contains only excipients present in the IR d4T drug products that have been approved in a number of countries for the same dosage form, and (b) both test product and its comparator are either very rapidly dissolving or rapidly dissolving with similarity of dissolution profiles demonstrated at pH 1.2, 4.5, and 6.8. (c) 2011 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 101:1016, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to develop a physiologically compatible inhalation solution of delta-9-tetrahydrocannabinol (THC), and to compare the pharmacokinetic and analgesic properties of pulmonal THC versus pulmonal placebo and intravenous (iv) THC, respectively. Eight healthy volunteers were included in this randomized, double-blind, crossover study. The aqueous THC formulations were prepared by using a solubilization technique. iv THC (0.053 mg/kg body weight), pulmonal THC (0.053 mg/kg), or a placebo inhalation solution was administered as single dose. At defined time points, blood samples were collected, and somatic and psychotropic side effects as well as vital functions monitored. An ice water immersion test was performed to measure analgesia. Using a pressure-driven nebulizer, the pulmonal administration of the THC liquid aerosol resulted in high THC peak plasma levels within minutes. The bioavailability of the pulmonal THC was 28.7 +/- 8.2% (mean +/- SEM). The side effects observed after pulmonal THC were coughing and slight irritation of the upper respiratory tract, very mild psychotropic symptoms, and headache. The side effects after iv THC were much more prominent. Neither pulmonal nor iv THC significantly reduced experimentally induced pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose a nonparametric variance estimator when ranked set sampling (RSS) and judgment post stratification (JPS) are applied by measuring a concomitant variable. Our proposed estimator is obtained by conditioning on observed concomitant values and using nonparametric kernel regression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. The ability to sense the position of limb segments is a highly specialised proprioceptive function important for control of movement. Abnormal knee proprioception has been found in association with several musculoskeletal pathologies but whether nociceptive Stimulation can produce these proprioceptive changes is unclear. This study evaluated the effect of experimentally induced knee pain on knee joint position sense (JPS) in healthy individuals. Study design. Repeated measures, within-subject design. Methods. Knee JPS was tested in 16 individuals with no history of knee pathology under three experimental conditions: baseline control, a distraction task and knee pain induced by injection of hypertonic saline into the infrapatellar fat pad. Knee JPS was measured using active ipsilateral limb matching responses at 20degrees and 60degrees flexion whilst non-weightbearing (NWB) and 20degrees flexion single leg stance. During the tasks, the subjective perception of distraction and severity of pain were measured using 11-point numerical rating scales. Results. Knee JPS was not altered by acute knee pain in any of the positions tested. The distraction task resulted in poorer concentration, greater JPS absolute errors at 20degrees NWB, and greater variability in errors during the WB tests. There were no significant correlations between levels of pain and changes in JPS errors. Changes in JPS with pain and distraction were inversely related to baseline knee JPS variable error in all test positions (r = -0.56 to -0.91) but less related to baseline absolute error. Conclusion. Knee JPS is reduced by an attention-demanding task but not by experimentally induced pain. (C) 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Changes in the position of the head and neck have been shown to introduce a systematic deviation in the end-point error of an upper limb pointing task. Although previous authors have attributed this to alteration of perceived target location, no studies have explored the effect of changes in head and neck position on the perception of limb position. This study investigated whether changes in head and neck position affect a specific component of movement performance, that is, the accuracy of joint position sense (JPS) at the elbow. Elbow JPS was tested with the neck in four positions: neutral, flexion, rotation and combined flexion/rotation. A target angle was presented passively with the neck in neutral, after a rest period; this angle was reproduced actively with the head and neck in one of the test positions. The potential effects of distraction from head movement were controlled for by performing a movement control in which the head and neck were in neutral for the presentation and reproduction of the target angle, but moved into flexion during the rest period. The absolute and variable joint position errors (JPE) were greater when the target angle was reproduced with the neck in the flexion, rotation, and combined flexion/rotation than when the head and neck were in neutral. This study suggests that the reduced accuracy previously seen in pointing tasks with changes in head position may be partly because of errors in the interpretation of arm position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acuity for elbow joint position sense (JPS) is reduced when head position is modified. Movement of the head is associated with biomechanical changes in the neck and shoulder musculoskeletal system, which may explain changes in elbow JPS. The present study aimed to determine whether elbow JPS is also influenced by illusory changes in head position. Simultaneous vibration of sternocleidomastoid (SCM) and the contralateral splenius was applied to 14 healthy adult human subjects. Muscle vibration or passive head rotation was introduced between presentation and reproduction of a target elbow position. Ten out of 14 subjects reported illusions consistent with lengthening of the vibrated muscles. In these 10 subjects, absolute error for elbow JPS increased with left SCM/right splenius vibration but not with right SCM/left splenius vibration. Absolute error also increased with right rotation, with a trend for increased error with left rotation. These results demonstrated that both actual and illusory changes in head position are associated with diminished acuity for elbow JPS, suggesting that the influence of head position on upper limb JPS depends, at least partially, on perceived head position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context: Clinicians use exercises in rehabilitation to enhance sensorimotor-function, however evidence supporting their use is scarce. Objective: To evaluate acute effects of handheld-vibration on joint position sense (JPS). Design: A repeated-measure, randomized, counter-balanced 3-condition design. Setting: Sports Medicine and Science Research Laboratory. Patients or Other Participants: 31 healthy college-aged volunteers (16-males, 15-females; age=23+3y, mass=76+14kg, height=173+8cm). Interventions: We measured elbow JPS and monitored training using the Flock-of-Birds system (Ascension Technology, Burlington, VT) and MotionMonitor software (Innsport, Chicago, IL), accurate to 0.5°. For each condition (15,5,0Hz vibration), subjects completed three 15-s bouts holding a 2.55kg Mini-VibraFlex dumbbell (Orthometric, New York, NY), and used software-generated audio/visual biofeedback to locate the target. Participants performed separate pre- and post-test JPS measures for each condition. For JPS testing, subjects held a non-vibrating dumbbell, identified the target (90°flexion) using biofeedback, and relaxed 3-5s. We removed feedback and subjects recreated the target and pressed a trigger. We used SPSS 14.0 (SPSS Inc., Chicago, IL) to perform separate ANOVAs (p<0.05) for each protocol and calculated effect sizes using standard-mean differences. Main Outcome Measures: Dependent variables were absolute and variable error between target and reproduced angles, pre-post vibration training. Results: 0Hz (F1,61=1.310,p=0.3) and 5Hz (F1,61=2.625,p=0.1) vibration did not affect accuracy. 15Hz vibration enhanced accuracy (6.5±0.6 to 5.0±0.5°) (F1,61=8.681,p=0.005,ES=0.3). 0Hz did not affect variability (F1,61=0.007,p=0.9). 5Hz vibration decreased variability (3.0±1.8 to 2.3±1.3°) (F1,61=7.250,p=0.009), as did 15Hz (2.8±1.8 to 1.8±1.2°) (F1,61=24.027, p<0.001). Conclusions: Our results support using handheld-vibration to improve sensorimotor-function. Future research should include injured subjects, functional multi-joint/multi-planar measures, and long-term effects of similar training.