925 resultados para Iris (Eye)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In general optical systems, the range of distances over which the detector cannot detect any change in focus is called the depth-of-field. This may be specified by movement of the object or image planes, with the former being referred to as depth-of-field and the latter as depth-of-focus (DOF). Either term can be used in vision science, where we refer to changes in vergence which have the same value in both object and image space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on the sensual experience of place is not a mainstream topic in the architectural debate; it is more common in other disciplines like landscape architecture or interior design. The curriculum sometime offers opportunities of cross-pollination between disciplines; students in architecture courses might be exposed to different theories of space more typical to other fields. This paper explore the teaching/research nexus within QUT Master of Architecture research stream; the focus of the discussion is students’ experimentation with people’s experience and navigation of the public space. Theories of placemaking in relation to urban design are first introduced; then the teaching/research nexus is discussed; finally students’ experience in approaching phenomenological research within the Master of Architecture are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iris based identity verification is highly reliable but it can also be subject to attacks. Pupil dilation or constriction stimulated by the application of drugs are examples of sample presentation security attacks which can lead to higher false rejection rates. Suspects on a watch list can potentially circumvent the iris based system using such methods. This paper investigates a new approach using multiple parts of the iris (instances) and multiple iris samples in a sequential decision fusion framework that can yield robust performance. Results are presented and compared with the standard full iris based approach for a number of iris degradations. An advantage of the proposed fusion scheme is that the trade-off between detection errors can be controlled by setting parameters such as the number of instances and the number of samples used in the system. The system can then be operated to match security threat levels. It is shown that for optimal values of these parameters, the fused system also has a lower total error rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncooperative iris identification systems at a distance suffer from poor resolution of the acquired iris images, which significantly degrades iris recognition performance. Super-resolution techniques have been employed to enhance the resolution of iris images and improve the recognition performance. However, most existing super-resolution approaches proposed for the iris biometric super-resolve pixel intensity values, rather than the actual features used for recognition. This paper thoroughly investigates transferring super-resolution of iris images from the intensity domain to the feature domain. By directly super-resolving only the features essential for recognition, and by incorporating domain specific information from iris models, improved recognition performance compared to pixel domain super-resolution can be achieved. A framework for applying super-resolution to nonlinear features in the feature-domain is proposed. Based on this framework, a novel feature-domain super-resolution approach for the iris biometric employing 2D Gabor phase-quadrant features is proposed. The approach is shown to outperform its pixel domain counterpart, as well as other feature domain super-resolution approaches and fusion techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Driver sleepiness contributes substantially to fatal and severe crashes and the contribution it makes to less serious crashes is likely to as great or greater. Currently, drivers’ awareness of sleepiness (subjective sleepiness) remains a critical component for the mitigation of sleep-related crashes. Nonetheless, numerous calls have been made for technological monitors of drivers’ physiological sleepiness levels so drivers can be ‘alerted’ when approaching high levels of sleepiness. Several physiological indices of sleepiness show potential as a reliable metric to monitor drivers’ sleepiness levels, with eye blink indices being a promising candidate. However, extensive evaluations of eye blink measures are lacking including the effects that the endogenous circadian rhythm can have on eye blinks. To examine the utility of ocular measures, 26 participants completed a simulated driving task while physiological measures of blink rate and duration were recorded after partial sleep restriction. To examine the circadian effects participants were randomly assigned to complete either a morning or an afternoon session of the driving task. The results show subjective sleepiness levels increased over the duration of the task. The blink duration index was sensitive to increases in sleepiness during morning testing, but was not sensitive during afternoon testing. This finding suggests that the utility of blink indices as a reliable metric for sleepiness are still far from specific. The subjective measures had the largest effect size when compared to the blink measures. Therefore, awareness of sleepiness still remains a critical factor for driver sleepiness and the mitigation of sleep-related crashes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the association between conjunctival ultraviolet autofluorescence (UVAF), a biomarker of ocular ultraviolet radiation (UVR) exposure, and prevalent pterygium. Methods: We conducted a cross-sectional study on Norfolk Island, South Pacific. All permanent residents aged ‡15 were invited to participate. Participants completed a sun exposure questionnaire and underwent autorefraction and slit lamp biomicroscope examination. Area of conjunctival UVAF (sum of temporal ⁄ nasal area in right and left eyes) was determined using computerized methods. Multivariate logistic and linear regression models were used to estimate the associations with pterygia and UVAF, respectively. Results: Of 641 participants, 70 people (10.9%) had pterygium in one or both eyes, and prevalence was higher in males (15.0% versus 7.7%, p = 0.003). Significant independent associations with pterygium in any eye were UVAF (per 10 mm2) [odds ratio (OR) 1.16, 95% confidence interval (CI) 1.16–1.28, p = 0.002], tanning skin phenotype (OR 2.17,1.20–3.92, p = 0.010) and spending more than three-quarters of the day outside (OR 2.22, 1.20–4.09, p = 0.011). Increasing quartile of UVAF was associated with increased risk of pterygium following adjustment of age, sex and time outdoors (pTrend = 0.002). Independent associations with increasing UVAF (per 10 mm2) were decreasing age, time outdoors, skin type and male gender (all p < 0.001). UVAF area correlated well with the duration of outdoor activity (pTrend < 0.001). Conclusion: Pterygium occurs in approximately one-tenth of Norfolk Islanders. Increasing conjunctival UVAF is associated with prevalent pterygia, confirming earlier epidemiological, laboratory and ray-tracing studies that pterygia are associated with UVR. Protection from the sun should be encouraged to reduce the prevalence of pterygium in the community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to describe the distribution of conjunctival ultraviolet autofluorescence (UVAF) in an adult population. METHODS: We conducted a cross-sectional, population-based study in the genetic isolate of Norfolk Island, South Pacific Ocean. In all, 641 people, aged 15 to 89 years, were recruited. UVAF and standard (control) photographs were taken of the nasal and temporal interpalpebral regions bilaterally. Differences between the groups for non-normally distributed continuous variables were assessed using the Wilcoxon-Mann-Whitney ranksum test. Trends across categories were assessed using Cuzick's non-parametric test for trend or Kendall's rank correlation τ. RESULTS: Conjunctival UVAF is a non-parametric trait with a positively skewed distribution. Median amount of conjunctival UVAF per person (sum of four measurements; right nasal/temporal and left nasal/temporal) was 28.2 mm(2) (interquartile range 14.5-48.2). There was an inverse, linear relationship between UVAF and advancing age (P<0.001). Males had a higher sum of UVAF compared with females (34.4 mm(2) vs 23.2 mm(2), P<0.0001). There were no statistically significant differences in area of UVAF between right and left eyes or between nasal and temporal regions. CONCLUSION: We have provided the first quantifiable estimates of conjunctival UVAF in an adult population. Further data are required to provide information about the natural history of UVAF and to characterise other potential disease associations with UVAF. UVR protective strategies should be emphasised at an early age to prevent the long-term adverse effects on health associated with excess UVR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We aimed to determine the prevalence and associations of refractive error on Norfolk Island. DESIGN: Population-based study on Norfolk Island, South Pacific. PARTICIPANTS: All permanent residents on Norfolk Island aged ≥ 15 years were invited to participate. METHODS: Patients underwent non-cycloplegic autorefraction, slit-lamp biomicroscope examination and biometry assessment. Only phakic eyes were analysed. MAIN OUTCOME MEASURES: Prevalence and multivariate associations of refractive error and myopia. RESULTS: There were 677 people (645 right phakic eyes, 648 left phakic eyes) aged ≥ 15 years were included in this study. Mean age of participants was 51.1 (standard deviation 15.7; range 15-81). Three hundred and seventy-six people (55.5%) were female. Adjusted to the 2006 Norfolk Island population, prevalence estimates of refractive error were as follows: myopia (mean spherical equivalent ≥ -1.0 D) 10.1%, hypermetropia (mean spherical equivalent ≥ 1.0 D) 36.6%, and astigmatism 17.7%. Significant independent predictors of myopia in the multivariate model were lower age (P < 0.001), longer axial length (P < 0.001), shallower anterior chamber depth (P = 0.031) and increased corneal curvature (P < 0.001). Significant independent predictors of refractive error were increasing age (P < 0.001), male gender (P = 0.009), Pitcairn ancestry (P = 0.041), cataract (P < 0.001), longer axial length (P < 0.001) and decreased corneal curvature (P < 0.001). CONCLUSIONS: The prevalence of myopia on Norfolk Island is lower than on mainland Australia, and the Norfolk Island population demonstrates ethnic differences in the prevalence estimates. Given the significant associations between refractive error and several ocular biometry characteristics, Norfolk Island may be a useful population in which to find the genetic basis of refractive error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To describe the recruitment, ophthalmic examination methods and distribution of ocular biometry of participants in the Norfolk Island Eye Study, who were individuals descended from the English Bounty mutineers and their Polynesian wives. Methods: All 1,275 permanent residents of Norfolk Island aged over 15 years were invited to participate, including 602 individuals involved in a 2001 cardiovascular disease study. Participants completed a detailed questionnaire and underwent a comprehensive eye assessment including stereo disc and retinal photography, ocular coherence topography and conjunctival autofluorescence assessment. Additionally, blood or saliva was taken for DNA testing. Results: 781 participants aged over 15 years were seen (54% female), comprising 61% of the permanent Island population. 343 people (43.9%) could trace their family history to the Pitcairn Islanders (Norfolk Island Pitcairn Pedigree). Mean anterior chamber depth was 3.32mm, mean axial length (AL) was 23.5mm, and mean central corneal thickness was 546 microns. There were no statistically significant differences in these characteristics between persons with and without Pitcairn Island ancestry. Mean intra-ocular pressure was lower in people with Pitcairn Island ancestry: 15.89mmHg compared to those without Pitcairn Island ancestry 16.49mmHg (P = .007). The mean keratometry value was lower in people with Pitcairn Island ancestry (43.22 vs. 43.52, P = .007). The corneas were flatter in people of Pitcairn ancestry but there was no corresponding difference in AL or refraction. Conclusion: Our study population is highly representative of the permanent population of Norfolk Island. Ocular biometry was similar to that of other white populations. Heritability estimates, linkage analysis and genome-wide studies will further elucidate the genetic determinants of chronic ocular diseases in this genetic isolate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research has successfully applied super-resolution and multiple modality fusion techniques to address the major challenges of human identification at a distance using face and iris. The outcome of the research is useful for security applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Over 40% of the permanent population of Norfolk Island possesses a unique genetic admixture dating to Pitcairn Island in the late 18 th century, with descendents having varying degrees of combined Polynesian and European ancestry. We conducted a population-based study to determine the prevalence and causes of blindness and low vision on Norfolk Island. Methods: All permanent residents of Norfolk Island aged ≥ 15 years were invited to participate. Participants completed a structured questionnaire/interview and underwent a comprehensive ophthalmic examination including slit-lamp biomicroscopy. Results: We recruited 781 people aged ≥ 15, equal to 62% of the permanent population, 44% of whom could trace their ancestry to Pitcairn Island. No one was bilaterally blind. Prevalence of unilateral blindness (visual acuity [VA] < 6/60) in those aged ≥ 40 was 1.5%. Blindness was more common in females (P=0.049) and less common in people with Pitcairn Island ancestry (P<0.001). The most common causes of unilateral blindness were age-related macular degeneration (AMD), amblyopia, and glaucoma. Five people had low vision (Best-Corrected VA < 6/18 in better eye), with 4 (80%) due to AMD. People with Pitcairn Island ancestry had a lower prevalence of AMD (P<0.001) but a similar prevalence of glaucoma to those without Pitcairn Island ancestry. Conclusions: The prevalence of blindness and visual impairment in this isolated Australian territory is low, especially amongst those with Pitcairn Island ancestry. AMD was the most common cause of unilateral blindness and low vision. The distribution of chronic ocular diseases on Norfolk Island is similar to mainland Australian estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: GABA antagonists inhibit experimental myopia in chick and GABA receptors have been localized to chick sclera and the retinal pigment epithelium (RPE). The RPE and the choroid alter scleral DNA and glycosaminoglycan (GAG) content in vitro; opposite effects have been observed for tissues from myopic and hyperopic eyes. The aim was to determine the effect of GABAergic agents on the DNA and GAG content of chick scleral fibroblasts directly and in co-culture with ocular tissues from myopic and hyperopic chick eyes. Materials and Methods: Primary cultures of fibroblastic cells expressing vimentin and α-smooth muscle actin were established. GABAergic agents were added separately (i) to the culture medium of the scleral cells and (ii) to the culture medium of the scleral cells with the addition of posterior eye cup tissue (retina, RPE, retina + RPE, choroid + RPE) to cell culture inserts. Ocular tissues were obtained from chick eyes wearing + 15D (lens-induced hyperopia, LIH) or −15D lenses (lens-induced myopia, LIM) for three days (post-hatch day 5–8) (n = 12). GAG and DNA content of scleral fibroblasts were measured. Results: GABA agents had a small direct effect on scleral cell GAG and DNA content but a larger effect was measured when GABA agents were added to the culture medium with myopic and hyperopic RPE and choroid + RPE tissues. GABA agonists increased (p = 0.002) whereas antagonists decreased (p = 0.0004) DNA content of scleral cells; effects were opposite for scleral GAG content. GABA agents significantly altered the effect of both LIM and LIH tissues (p = 0.0005) compared to control; the effects were greater for LIM tissue versus LIH tissue co-culture (p = 0.0004). Conclusion: GABAergic agents affect the DNA and GAG content of scleral fibroblasts both directly and when co-cultured with ocular tissues. GABA antagonists that prevent myopia development in chick model could act via a scleral mechanism utilizing the RPE/choroid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess intrasessional and intersessional repeatability of two commercial partial coherence interferometry instruments for measuring peripheral eye lengths and to investigate the agreement between the two instruments. Methods: Central and peripheral eye lengths were determined with the IOLMaster (Carl-Zeiss Meditec AG, Jena, Germany) and the Lenstar (Haag Streit, Bern, Switzerland) in seven adults. Measurements were performed out to 35° and 30° from fixation for horizontal and vertical visual fields, respectively, in 5° intervals. An external fixation target at optical infinity was used. At least four measurements were taken at each location for each instrument, and measurements were taken at two sessions. Results: The mean intrasessional SDs for the IOLMaster along both the horizontal and vertical visual fields were 0.04 ± 0.04 mm; corresponding results for the Lenstar were 0.02 ± 0.02 mm along both fields. The intersessional SDs for the IOLMaster for the horizontal and vertical visual fields were ±0.11 and ±0.08 mm, respectively; corresponding limits for the Lenstar were ±0.05 and ±0.04 mm. The intrasessional and intersessional variability increased away from fixation. The mean differences between the two instruments were 0.01 ± 0.07 mm and 0.02 ± 0.07 mm in the horizontal and vertical visual fields, but the lengths with the Lenstar became greater than those with the IOLMaster as axial length increased (rate of approximately 0.016 mm/mm). Conclusions: Both the IOLMaster and the Lenstar demonstrated good intrasessional and intersessional repeatability for peripheral eye length measurements, with the Lenstar showing better repeatability. The Lenstar would be expected to give a slightly greater range of eye lengths than the IOLMaster across the visual field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid. Methods Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (±30°) and, for a subset of eight participants along the vertical visual field (±25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ±30° along horizontal and vertical visual fields. Results Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s. Conclusion Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ±30° and ±25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths.